Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.

Abstract:

:Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring of airway obstruction. We developed a FOT device for home monitoring of Zrs which transmits the data through the Internet. Its accuracy, stability and reliability were evaluated in a pilot study measuring the Zrs in the unsupervised self-measurements of five healthy subjects. Finally, to explore the applicability of the concept, 36 consecutive daily home measurements were recorded from one healthy subject and one chronic obstructive pulmonary disease (COPD) patient. The accuracy of the device fulfilled FOT guidelines, and the reliability test showed a mean discrepancy of resistance of 0.10 +/- 0.01 cmH(2)O s L(-1). The data from the healthy subjects demonstrated high repeatability in assessing Zrs. The measurements on the healthy subjects and the patient with COPD suggest the feasibility of unsupervised FOT measurements. The healthy subjects showed minimal daily variations in Zrs, whereas the patient with COPD had large differences in mean values and important fluctuations over day-to-day measurements. The results of the pilot study demonstrate that unsupervised home monitoring of Zrs using the FOT yields accurate and reproducible data. It could provide new insights into the dynamics of airway obstruction and improve the understanding and management of obstructive diseases.

journal_name

Physiol Meas

authors

Dellacà RL,Gobbi A,Pastena M,Pedotti A,Celli B

doi

10.1088/0967-3334/31/4/N01

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

N11-24

issue

4

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(10)33232-3

journal_volume

31

pub_type

杂志文章
  • Real time impedance plots with arbitrary frequency components.

    abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/1/008

    authors: Searle A,Kirkup L

    更新日期:1999-02-01 00:00:00

  • Gastrointestinal arrhythmias are associated with statistically significant fluctuations in systemic information dimension.

    abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/5/N01

    authors: Irimia A,Wikswo JP Jr

    更新日期:2008-05-01 00:00:00

  • Comprehensive analysis of cardiac health using heart rate signals.

    abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/5/005

    authors: Acharya U R,Kannathal N,Krishnan SM

    更新日期:2004-10-01 00:00:00

  • Real-time arrhythmia detection with supplementary ECG quality and pulse wave monitoring for the reduction of false alarms in ICUs.

    abstract::False intensive care unit (ICU) alarms induce stress in both patients and clinical staff and decrease the quality of care, thus significantly increasing both the hospital recovery time and rehospitalization rates. In the PhysioNet/CinC Challenge 2015 for reducing false arrhythmia alarms in ICU bedside monitor data, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1273

    authors: Krasteva V,Jekova I,Leber R,Schmid R,Abächerli R

    更新日期:2016-08-01 00:00:00

  • Measurements of fluorine in contemporary urban Canadians: a comparison of the levels found in human bone using in vivo and ex vivo neutron activation analysis.

    abstract::Non-invasive in vivo neutron activation analysis (NAA) was used to measure the fluorine concentration in 35 people in Hamilton, Ontario, Canada. Measurement and precision data of this second generation NAA system were determined in 2013, and the results were compared with the performance of a first generation system u...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/3/465

    authors: Mostafaei F,McNeill FE,Chettle DR,Wainman BC,Pidruczny AE,Prestwich WV

    更新日期:2015-03-01 00:00:00

  • The possible role of the vagal nervous system in the recovery of the blood pressure control after cardiac arrest: a porcine model study.

    abstract::Previous studies have proved that the baroreceptor reflex (baroreflex) control of heart rate can be used for stratification of post-infarction population and, in general, cardiovascular disease populations. Many methods have been proposed to estimate the so-called baroreflex sensitivity (BRS) expressed as ms mmhg-1. M...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/38/1/63

    authors: Lavanga M,Baselli G,Fumagalli F,Ristagno G,Ferrario M

    更新日期:2017-01-01 00:00:00

  • PET(CO2) measurement and feature extraction of capnogram signals for extubation outcomes from mechanical ventilation.

    abstract::Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However,...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/2/231

    authors: Rasera CC,Gewehr PM,Domingues AM

    更新日期:2015-02-01 00:00:00

  • Are ejection fractions from gated SPECT perfusion studies clinically useful? A comparison with radionuclide ventriculography.

    abstract::Gated SPECT (GSPECT) was evaluated for the measurement of left ventricular ejection fraction (LVEF) by comparing with equilibrium gated radionuclide ventriculography (RNVG). A total of 99 subjects underwent GSPECT and RNVG imaging. All studies were acquired in list mode with GSPECT studies processed to give 16- and 8-...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/22/2/312

    authors: Wright GA,McDade M,Keeble W,Martin W,Hutton I

    更新日期:2001-05-01 00:00:00

  • A deep neural network for estimating the bladder boundary using electrical impedance tomography.

    abstract:OBJECTIVE:Accurate bladder size estimation is an important clinical parameter that assists physicians, enabling them to provide better treatment for patients who are suffering from urinary incontinence. Electrical impedance tomography (EIT) is a non-invasive medical imaging method that estimates organ boundaries assumi...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abaa56

    authors: Konki SK,Khambampati AK,Sharma SK,Kim KY

    更新日期:2020-12-18 00:00:00

  • Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration.

    abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab21af

    authors: Lucas BP,D'Addio A,Block C,Manning H,Remillard B,Leiter JC

    更新日期:2019-07-01 00:00:00

  • Video rate electrical impedance tomography of vascular changes: preclinical development.

    abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/3/006

    authors: Halter R,Hartov A,Paulsen K

    更新日期:2008-03-01 00:00:00

  • Sleep stage classification with ECG and respiratory effort.

    abstract::Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2027

    authors: Fonseca P,Long X,Radha M,Haakma R,Aarts RM,Rolink J

    更新日期:2015-10-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • Validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake.

    abstract::The purpose of this study was to determine the validity and reliability of a timed 5 km cycle ergometer ride to predict maximum oxygen uptake (VO2max). Fifty-two healthy volunteers had their VO2max determined during a maximal treadmill run. They also performed a timed 5 km cycle ergometer ride. The resistance setting ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1088/0967-3334/17/4/009

    authors: Buono MJ,Borin TL,Sjoholm NT,Hodgdon JA

    更新日期:1996-11-01 00:00:00

  • Physiological motion monitoring: a wearable device and adaptative algorithm for sit-to-stand timing detection.

    abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/8/006

    authors: Giansanti D,Maccioni G

    更新日期:2006-08-01 00:00:00

  • Estimation of sleep stages in a healthy adult population from optical plethysmography and accelerometer signals.

    abstract:OBJECTIVE:This paper aims to report on the accuracy of estimating sleep stages using a wrist-worn device that measures movement using a 3D accelerometer and an optical pulse photoplethysmograph (PPG). APPROACH:Overnight recordings were obtained from 60 adult participants wearing these devices on their left and right w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9047

    authors: Beattie Z,Oyang Y,Statan A,Ghoreyshi A,Pantelopoulos A,Russell A,Heneghan C

    更新日期:2017-10-31 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Electroencephalography as a predictor of self-report fatigue/sleepiness during monotonous driving in train drivers.

    abstract:OBJECTIVE:In this study, electroencephalography activity recorded during monotonous driving was investigated to examine the predictive capability of monopolar EEG analysis for fatigue/sleepiness in a cohort of train drivers. APPROACH:Sixty-three train drivers participated in the study, where 32- lead monopolar EEG dat...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae42e

    authors: Lees T,Chalmers T,Burton D,Zilberg E,Penzel T,Lal S,Lal S

    更新日期:2018-10-30 00:00:00

  • A comparison of technologies used for estimation of body temperature.

    abstract::Body temperature measurement is an important clinical parameter. The performance of a number of non-invasive thermometers was measured by comparing intra- and inter-operator variability (n = 100) and clinical accuracy (n = 61). Variability was elevated in febrile compared to normothermic subjects for axillary and oral...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/003

    authors: Mangat J,Standley T,Prevost A,Vasconcelos J,White P

    更新日期:2010-09-01 00:00:00

  • Energy scavenging sources for biomedical sensors.

    abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/30/9/R01

    authors: Romero E,Warrington RO,Neuman MR

    更新日期:2009-09-01 00:00:00

  • Auditory magnetic fields in cochlear-implant patients.

    abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/14/4a/014

    authors: Pelizzone M

    更新日期:1993-11-01 00:00:00

  • Cardiac eigen imaging: a novel method to isolate cardiac activity in thoracic electrical impedance tomography.

    abstract:OBJECTIVE:As the global burden of cardiovascular disease increases, proactive cardiovascular healthcare by means of accurate, precise, continuous, and non-invasive monitoring is becoming crucial. However, no current device is able to provide cardiac hemodynamic monitoring with the aforementioned criterion. Electrical i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abb141

    authors: Arshad SH,Murphy EK,Callahan JM,DeVries JT,Odame KM,Halter RJ

    更新日期:2020-10-06 00:00:00

  • Wearable sensors for patient-specific boundary shape estimation to improve the forward model for electrical impedance tomography (EIT) of neonatal lung function.

    abstract::Electrical impedance tomography (EIT) could be significantly advantageous to continuous monitoring of lung development in newborn and, in particular, preterm infants as it is non-invasive and safe to use within the intensive care unit. It has been demonstrated that accurate boundary form of the forward model is import...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1149

    authors: Khor JM,Tizzard A,Demosthenous A,Bayford R

    更新日期:2014-06-01 00:00:00

  • Impedance analyser module for EIT and spectroscopy using undersampling.

    abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/303

    authors: Dudykevych T,Gersing E,Thiel F,Hellige G

    更新日期:2001-02-01 00:00:00

  • Video and audio processing in paediatrics: a review.

    abstract:OBJECTIVE:Video and sound acquisition and processing technologies have seen great improvements in recent decades, with many applications in the biomedical area. The aim of this paper is to review the overall state of the art of advances within these topics in paediatrics and to evaluate their potential application for ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab0096

    authors: Cabon S,Porée F,Simon A,Rosec O,Pladys P,Carrault G

    更新日期:2019-02-26 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    abstract::False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1298

    authors: Liu C,Zhao L,Tang H,Li Q,Wei S,Li J

    更新日期:2016-08-01 00:00:00

  • A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

    abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/3/002

    authors: Kong W,Huang J,Rollins DL,Ideker RE,Smith WM

    更新日期:2007-03-01 00:00:00

  • Permutation Lempel-Ziv complexity measure of electroencephalogram in GABAergic anaesthetics.

    abstract::Monitoring the brain state in anaesthesia is crucial for clinical doctors. In this study, we propose a novel nonlinear method, the permutation Lempel-Ziv complexity (PLZC) index, which describes the complexity in the electroencephalographic (EEG) signal to quantify the effect of GABAergic anaesthetics on brain activit...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/12/2483

    authors: Bai Y,Liang Z,Li X,Voss LJ,Sleigh JW

    更新日期:2015-12-01 00:00:00

  • A pH-mucosa area unit of measure to consider morphology of the oesophagus when evaluating oesophagitis.

    abstract::Gastro-oesophageal pH measurements are routinely carried out to quantify and determine if levels of acid reflux are responsible for symptoms. Although considered the 'gold standard', evidence suggests that pH measurements do not correlate well with the degree of oesophagitis seen during endoscopy. In this study the cu...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/4/006

    authors: Haylett KR,Vales P,Lee SH,McCloy RF

    更新日期:2003-11-01 00:00:00