Abstract:
OBJECTIVE:Accurate bladder size estimation is an important clinical parameter that assists physicians, enabling them to provide better treatment for patients who are suffering from urinary incontinence. Electrical impedance tomography (EIT) is a non-invasive medical imaging method that estimates organ boundaries assuming that the electrical conductivity values of the background, bladder, and adjacent tissues inside the pelvic domain are known a priori. However, the performance of a traditional EIT inverse algorithm such as the modified Newton-Raphson (mNR) for shape estimation exhibits severe convergence problems as it heavily depends on the initial guess and often fails to estimate complex boundaries that require greater numbers of Fourier coefficients to approximate the boundary shape. Therefore, in this study a deep neural network (DNN) is introduced to estimate the urinary bladder boundary inside the pelvic domain. APPROACH:We designed a five-layer DNN which was trained with a dataset of 15 subjects that had different pelvic boundaries, bladder shapes, and conductivity. The boundary voltage measurements of the pelvic domain are defined as input and the corresponding Fourier coefficients that describe the bladder boundary as output data. To evaluate the DNN, we tested with three different sizes of urinary bladder. MAIN RESULTS:Numerical simulations and phantom experiments were performed to validate the performance of the proposed DNN model. The proposed DNN algorithm is compared with the radial basis function (RBF) and mNR method for bladder shape estimation. The results show that the DNN has a low root mean square error for estimated boundary coefficients and better estimation of bladder size when compared to the mNR and RBF. SIGNIFICANCE:We apply the first DNN algorithm to estimate the complex boundaries such as the urinary bladder using EIT. Our work provides a novel efficient EIT inverse solver to estimate the bladder boundary and size accurately. The proposed DNN algorithm has advantages in that it is simple to implement, and has better accuracy and fast estimation.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Konki SK,Khambampati AK,Sharma SK,Kim KYdoi
10.1088/1361-6579/abaa56subject
Has Abstractpub_date
2020-12-18 00:00:00pages
115003issue
11eissn
0967-3334issn
1361-6579journal_volume
41pub_type
杂志文章abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/3/318
更新日期:2001-08-01 00:00:00
abstract::The goal of the present study was to develop and evaluate a new method for the prediction of unexplained syncope occurrences. Diagnosis of syncope is currently based on the reproduction of symptoms in combination with hypotension and bradycardia induced by a 45 min 60-70 degrees head-upright tilt test (HUTT). The main...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/28/2/007
更新日期:2007-02-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/1361-6579/aab659
更新日期:2018-04-26 00:00:00
abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaa74d
更新日期:2018-02-28 00:00:00
abstract::The assessment and diagnosis of lower limb peripheral arterial occlusive disease (PAOD) is important since it can lead progressively to disabling claudication, ischaemic rest pain and gangrene. Historically, the first assessment has been palpation of the peripheral pulse since it can become damped, delayed and diminis...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/5/018
更新日期:2005-10-01 00:00:00
abstract::The paper presents a method for adaptive decomposition of an electrical bio-impedance (BI) signal into two components: cardiac and respiratory. The decomposition of a BI signal is not a trivial process because of the non-stationarity of the signal components and overlapping of their harmonic spectra. An application sp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/6/S02
更新日期:2008-06-01 00:00:00
abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/1/83
更新日期:2016-01-01 00:00:00
abstract::Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable a...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/9/010
更新日期:2011-09-01 00:00:00
abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/7/S10
更新日期:2007-07-01 00:00:00
abstract::Although cardiac arrhythmias have been studied extensively, little is known about arrhythmic phenomena in the gastrointestinal (GI) system. In this study, we demonstrate for the first time that the onset of GI arrhythmias is associated with statistically significant fluctuations in the information dimension of the ass...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/5/N01
更新日期:2008-05-01 00:00:00
abstract::Measurement of the velocity of propagation and attenuation of ultrasound (200 kHz) is believed to be a useful non-invasive technique for assessing the mechanical properties of bone. A new method for the determination of ultrasound velocity and attenuation of longitudinal waves in cortical bone was used in vivo and in ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/17/3/006
更新日期:1996-08-01 00:00:00
abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/6/022
更新日期:2005-12-01 00:00:00
abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1785
更新日期:2016-10-01 00:00:00
abstract::This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvemen...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/26/3/R02
更新日期:2005-06-01 00:00:00
abstract::If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, ma...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/1/308
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:The healing of wounds is critical in protecting the human body against environmental factors. The mechanisms involving protein expression during this complex physiological process have not been fully elucidated. APPROACH:Here, we use reverse-phase protein microarrays (RPPA) involving 94 phosphoproteins to st...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aaee19
更新日期:2018-12-07 00:00:00
abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/011
更新日期:2007-05-01 00:00:00
abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/001
更新日期:2004-02-01 00:00:00
abstract::Cerebral autoregulation has been studied by linear filter systems, with arterial blood pressure (ABP) as the input and cerebral blood flow velocity (CBFV-from transcranial Doppler Ultrasound) as the output. The current work extends this by using adaptive filters to investigate the dynamics of time-varying cerebral aut...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/10/001
更新日期:2010-10-01 00:00:00
abstract:OBJECTIVE:To provide a non-invasive approach to monitoring lung function in spontaneously breathing lambs, from birth to five months of life, by the forced oscillation technique (FOT). This report describes the experimental set-up, data processing, and identification of normal predicted values of resistance (Rrs) and r...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab3493
更新日期:2019-11-04 00:00:00
abstract::Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/19/2/013
更新日期:1998-05-01 00:00:00
abstract::Monitoring the brain state in anaesthesia is crucial for clinical doctors. In this study, we propose a novel nonlinear method, the permutation Lempel-Ziv complexity (PLZC) index, which describes the complexity in the electroencephalographic (EEG) signal to quantify the effect of GABAergic anaesthetics on brain activit...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/12/2483
更新日期:2015-12-01 00:00:00
abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/011
更新日期:2005-08-01 00:00:00
abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aae625
更新日期:2018-10-30 00:00:00
abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/12/005
更新日期:2010-12-01 00:00:00
abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/34/6/713
更新日期:2013-06-01 00:00:00
abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/4/401
更新日期:2001-11-01 00:00:00
abstract:OBJECTIVE:This paper aims to report on the accuracy of estimating sleep stages using a wrist-worn device that measures movement using a 3D accelerometer and an optical pulse photoplethysmograph (PPG). APPROACH:Overnight recordings were obtained from 60 adult participants wearing these devices on their left and right w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa9047
更新日期:2017-10-31 00:00:00
abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abc0b6
更新日期:2020-12-11 00:00:00
abstract::In electrical impedance tomography (EIT) two-dimensional models continue to be applied despite their known inability to provide correct reconstruction. In this paper, a reconstruction algorithm that assumes a translationally invariant conductivity distribution is described. A more precise forward solver is obtained by...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/1/308
更新日期:2000-02-01 00:00:00