PET(CO2) measurement and feature extraction of capnogram signals for extubation outcomes from mechanical ventilation.

Abstract:

:Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However, a substantial debate remains as to whether capnography is useful during the process of weaning and extubation from MV during the postoperative period. Thus, the main objective of this study was to present a new use for time-based capnography data by measuring the end-tidal CO2 pressure ([Formula: see text]), partial pressure of arterial CO2 ([Formula: see text]) and feature extraction of capnogram signals before extubation from MV to evaluate the capnography as a predictor of outcome extubation in infants after cardiac surgery. Altogether, 82 measurements were analysed, 71.9% patients were successfully extubated, and 28.1% met the criteria for extubation failure within 48 h. The ROC-AUC analysis for quantitative measure of the capnogram showed significant differences (p < 0.001) for: expiratory time (0.873), slope of phase III (0.866), slope ratio (0.923) and ascending angle (0.897). In addition, the analysis of [Formula: see text] (0.895) and [Formula: see text] (0.924) obtained 30 min before extubation showed significant differences between groups. The [Formula: see text] mean value for success and failure extubation group was 39.04 mmHg and 46.27 mmHg, respectively. It was also observed that high CO2 values in patients who had returned MV was 82.8  ±  21 mmHg at the time of extubation failure. Thus, [Formula: see text] measurements and analysis of features extracted from a capnogram can differentiate extubation outcomes in infant patients under MV, thereby reducing the physiologic instability caused by failure in this process.

journal_name

Physiol Meas

authors

Rasera CC,Gewehr PM,Domingues AM

doi

10.1088/0967-3334/36/2/231

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

231-42

issue

2

eissn

0967-3334

issn

1361-6579

journal_volume

36

pub_type

杂志文章
  • Within-breath measurement of respiratory impedance.

    abstract::The measurement of the complex respiratory impedance at a high temporal resolution is described. The measurement of impedance is correlated with the breathing cycle using electrical transthoracic impedance. This allows the determination of the complex impedance at any fixed point in the respiratory cycle, which result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/3/019

    authors: van der Putten WJ,MacLeod D,Prichard JS

    更新日期:1993-08-01 00:00:00

  • Short-term studies of heart rate variability: comparison of two methods for recording.

    abstract::Heart rate variability (HRV) is often analysed using short-term studies. Our objective was to compare two of them in a group of diabetic patients (reduced HRV) and in a control group. From the same 10 min surface electrocardiogram (ECG) two recordings were obtained. In one of them the whole signal was acquired through...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/6/n01

    authors: Migliaro ER,Canetti R,Contreras P,Hakas M,Eirea G,Machado A

    更新日期:2004-12-01 00:00:00

  • A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

    abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/3/002

    authors: Kong W,Huang J,Rollins DL,Ideker RE,Smith WM

    更新日期:2007-03-01 00:00:00

  • Exposure to light and darkness and its influence on physiological measures of intensive care unit patients-a systematic literature review.

    abstract::Sleep-wake patterns are often significantly disturbed in critically ill patients. This disturbance is closely linked to secondary brain dysfunctions in these patients. Sedation not only impairs sleep quality in ICU patients but also has detrimental effects on short- and long-term outcome. In other contexts, light ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/37/9/R73

    authors: Weiss B,Spies C,Piazena H,Penzel T,Fietze I,Luetz A

    更新日期:2016-09-01 00:00:00

  • Effects of muscle injury severity on localized bioimpedance measurements.

    abstract::Muscle injuries in the lower limb are common among professional football players. Classification is made according to severity and is diagnosed with radiological assessment as: grade I (minor strain or minor injury), grade II (partial rupture, moderate injury) and grade III (complete rupture, severe injury). Tetrapola...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/27

    authors: Nescolarde L,Yanguas J,Lukaski H,Alomar X,Rosell-Ferrer J,Rodas G

    更新日期:2015-01-01 00:00:00

  • Feasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG.

    abstract:OBJECTIVE:To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND:Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physic...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840a

    authors: Kinnunen H,Rantanen A,Kenttä T,Koskimäki H

    更新日期:2020-05-07 00:00:00

  • Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

    abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab02ab

    authors: Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

    更新日期:2019-02-26 00:00:00

  • A planar elliptical model of cardio-vagal hysteresis.

    abstract::The state-dependent portion of cardio-vagal baroreflex control is called baroreflex hyteresis: we observe hysteresis when RR interval and carotid diameter depend on both the direction and value of arterial pressure. The elasticity of arterial walls, as well as the responsiveness of central command reset controls the r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/6/009

    authors: Ler AS,Cohen MA,Taylor JA

    更新日期:2010-06-01 00:00:00

  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • Aging in autonomic control by multifractal studies of cardiac interbeat intervals in the VLF band.

    abstract::The heart rate responds dynamically to various intrinsic and environmental stimuli. The autonomic nervous system is said to play a major role in this response. Multifractal analysis offers a novel method to assess the response of cardiac interbeat intervals. Twenty-four hour ECG recordings of RR interbeat intervals (o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/10/014

    authors: Makowiec D,Rynkiewicz A,Wdowczyk-Szulc J,Zarczyńska-Buchowiecka M,Gałaska R,Kryszewski S

    更新日期:2011-10-01 00:00:00

  • Linear and nonlinear characteristics of heart rate time series in obesity and during weight-reduction surgery.

    abstract::Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/002

    authors: Alam I,Lewis MJ,Morgan J,Baxter J

    更新日期:2009-07-01 00:00:00

  • Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration.

    abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab21af

    authors: Lucas BP,D'Addio A,Block C,Manning H,Remillard B,Leiter JC

    更新日期:2019-07-01 00:00:00

  • Impedance analyser module for EIT and spectroscopy using undersampling.

    abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/303

    authors: Dudykevych T,Gersing E,Thiel F,Hellige G

    更新日期:2001-02-01 00:00:00

  • A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals.

    abstract::A photoplethysmographic (PPG) signal can provide very useful information about a subject's cardiovascular status. Motion artifacts (MAs), which usually deteriorate the waveform of a PPG signal, severely obstruct its applications in the clinical diagnosis and healthcare area. To reduce the MAs from a PPG signal, in the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/10/2159

    authors: Peng F,Liu H,Wang W

    更新日期:2015-10-01 00:00:00

  • Assessment of 1-lead and 2-lead electrode patterns in electrical impedance endotomography.

    abstract::Electrical impedance endotomography (EIE) is a modality of impedance imaging where the electrodes are located on an insulating core placed at the centre of the region of interest. The absence of a physical limit to the medium surrounding the probe enables the use of remote electrodes. The present study compares the fe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/001

    authors: Fournier-Desseux A,Jossinet J

    更新日期:2005-08-01 00:00:00

  • Time-frequency analysis of heart rate variability using short-time fourier analysis.

    abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/2/303

    authors: Elsenbruch S,Wang Z,Orr WC,Chen JD

    更新日期:2000-05-01 00:00:00

  • Empirically derived cut-points for sedentary behaviour: are we sitting differently?

    abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of  <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1669

    authors: Clarke-Cornwell AM,Farragher TM,Cook PA,Granat MH

    更新日期:2016-10-01 00:00:00

  • Choice of reconstructed tissue properties affects interpretation of lung EIT images.

    abstract::Electrical impedance tomography (EIT) estimates an image of change in electrical properties within a body from stimulations and measurements at surface electrodes. There is significant interest in EIT as a tool to monitor and guide ventilation therapy in mechanically ventilated patients. In lung EIT, the EIT inverse p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1035

    authors: Grychtol B,Adler A

    更新日期:2014-06-01 00:00:00

  • A phantom for evaluating bone mineral density of the hand by dual-energy x-ray absorptiometry.

    abstract::Dual-energy x-ray absorptiometry (DXA) is a precise, widely used method for measuring bone mineral density (BMD), usually of the lumbar spine and femoral neck. Recent developments, such as a lower x-ray tube current and pixel by pixel analysis, enable smaller bones and thinner tissues volumes, as in the hand, to be me...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/18/3/008

    authors: Steel SA,Swann P,Langley G,Langton CM

    更新日期:1997-08-01 00:00:00

  • Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

    abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1785

    authors: Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

    更新日期:2016-10-01 00:00:00

  • Trabecular thickness measurement in cancellous bones: postmortem rat studies with the zoom-in micro-tomography technique.

    abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/008

    authors: Cho MH,Chun IK,Lee SC,Cho MH,Lee SY

    更新日期:2005-10-01 00:00:00

  • Potential neuroprotective effects of acupuncture stimulation on diabetes mellitus in a global ischemic rat model.

    abstract::Acupuncture (ACU) is known to be effective in ischemia treatment, and glutamate (GLU) excitotoxicity is an important factor in neuronal cell death. We observed the effect of ACU on cerebral blood flow (%CBF) and DeltaGLU (the changes in GLU release) in the ischemic stroke rat model of diabetic mellitus (DM). A global ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/5/003

    authors: Choi S,Lee GJ,Chae SJ,Kang SW,Yin CS,Lee SH,Choi SK,Park HK

    更新日期:2010-05-01 00:00:00

  • Validation of a finite-element solution for electrical impedance tomography in an anisotropic medium.

    abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S10

    authors: Abascal JF,Arridge SR,Lionheart WR,Bayford RH,Holder DS

    更新日期:2007-07-01 00:00:00

  • Simultaneous measurement of force and respiratory profiles during chest physiotherapy in ventilated children.

    abstract::There are currently no objective means of quantifying chest wall vibrations during manual physiotherapy. The aims of the study were to (i) develop a method to quantify physiotherapy-applied forces and simultaneous changes in respiratory flow and pressure, (ii) assess the feasibility of using this method in ventilated ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/9/004

    authors: Gregson RK,Stocks J,Petley GW,Shannon H,Warner JO,Jagannathan R,Main E

    更新日期:2007-09-01 00:00:00

  • Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality.

    abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1435

    authors: Di Marco LY,Duan W,Bojarnejad M,Zheng D,King S,Murray A,Langley P

    更新日期:2012-09-01 00:00:00

  • A multifrequency multichannel electrical impedance data acquisition system for body fluid shift monitoring.

    abstract::This paper discusses some important issues for the design of electrical impedance measurement systems intended for body fluid shift monitoring, in particular during dialysis treatments. We have studied two common signal generation systems: digital synthesis and carrier recovery. We have found that in prolonged measure...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/4/003

    authors: Lozano A,Rosell J,Pallás-Areny R

    更新日期:1995-11-01 00:00:00

  • Gastric activity studies using a magnetic tracer.

    abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/5/015

    authors: Cordova-Fraga T,Bernal-Alvarado JJ,Gutierrez-Juarez G,Sosa M,Vargas-Luna M

    更新日期:2004-10-01 00:00:00

  • Modelling of the immunoassay element of an optical immunosensor.

    abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/318

    authors: Keating SM,Flanagan MT

    更新日期:2001-08-01 00:00:00

  • Effect of lower body negative pressure and gravity on regional lung ventilation determined by EIT.

    abstract::The aim of our study was to check the effect of varying blood volume in the chest and gravity on the distribution of ventilation and aeration in the lungs. The change in intrathoracic blood volume was elicited by application of lower body negative pressure (LBNP) of -50 cmH2O. The variation of gravity in terms of hypo...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/003

    authors: Frerichs I,Bodenstein M,Dudykevych T,Hinz J,Hahn G,Hellige G

    更新日期:2005-04-01 00:00:00

  • Estimating carotid pulse and breathing rate from near-infrared video of the neck.

    abstract:OBJECTIVE:Non-contact physiological measurement is a growing research area that allows capturing vital signs such as heart rate (HR) and breathing rate (BR) comfortably and unobtrusively with remote devices. However, most of the approaches work only in bright environments in which subtle photoplethysmographic and balli...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae625

    authors: Chen W,Hernandez J,Picard RW

    更新日期:2018-10-30 00:00:00