A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research.

Abstract:

:We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and coronary artery blood flow and arterial blood pressure that are suitable for use with the system. The telemetry system consists of a front end, a backpack and a host PC. The front end is a watertight stainless steel case with all sensor electronics sealed inside; it acquires dimension, flow, pressure and five cardiac electrograms from selected locations on the heart. The backpack includes a control unit, Bluetooth radio, and batteries. The control unit digitizes eight channels of data from the front end and forwards them to the host PC via Bluetooth link. The host PC has a receiving Bluetooth radio and Labview programs to store and display data. The whole system was successfully tested on the bench and in an animal model. This telemetry system will greatly enhance the ability to study events leading to spontaneous sudden cardiac arrest.

journal_name

Physiol Meas

authors

Kong W,Huang J,Rollins DL,Ideker RE,Smith WM

doi

10.1088/0967-3334/28/3/002

subject

Has Abstract

pub_date

2007-03-01 00:00:00

pages

249-57

issue

3

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(07)37058-5

journal_volume

28

pub_type

杂志文章
  • Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics.

    abstract::The assessment and diagnosis of lower limb peripheral arterial occlusive disease (PAOD) is important since it can lead progressively to disabling claudication, ischaemic rest pain and gangrene. Historically, the first assessment has been palpation of the peripheral pulse since it can become damped, delayed and diminis...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/018

    authors: Allen J,Oates CP,Lees TA,Murray A

    更新日期:2005-10-01 00:00:00

  • Automatic sleep-stage scoring based on photoplethysmographic signals.

    abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab921d

    authors: Wu X,Yang J,Pan Y,Zhang X,Luo Y

    更新日期:2020-06-30 00:00:00

  • Capacitively-coupled ECG and respiration for the unobtrusive detection of sleep apnea.

    abstract:OBJECTIVE:The performance of a novel unobtrusive system based on capacitively-coupled electrocardiography (ccECG) combined with different respiratory measurements is evaluated for the detection of sleep apnea. APPROACH:A sleep apnea detection algorithm is proposed, which can be applied to electrocardiography (ECG) and...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abdf3d

    authors: Deviaene M,Castro I,Borzée P,Patel A,Torfs T,Buyse B,Testelmans D,Van Huffel S,Varon C

    更新日期:2021-01-22 00:00:00

  • Time-related heart autonomic balance characteristics in healthy subjects.

    abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/3/309

    authors: Matveev M,Prokopova R,Nachev Ch

    更新日期:2003-08-01 00:00:00

  • Generalizability of extracellular-to-intracellular fluid ratio using bio-impedance spectroscopy.

    abstract::Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/27/4/005

    authors: Turner AA,Lozano-Nieto A,Bouffard M

    更新日期:2006-04-01 00:00:00

  • Energy scavenging sources for biomedical sensors.

    abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/30/9/R01

    authors: Romero E,Warrington RO,Neuman MR

    更新日期:2009-09-01 00:00:00

  • Restoration of the electrocardiogram during mechanical cardiopulmonary resuscitation.

    abstract:OBJECTIVE:An artefact-free electrocardiogram (ECG) is essential during cardiac arrest to decide therapy such as defibrillation. Mechanical cardiopulmonary resuscitation (CPR) devices cause movement artefacts that alter the ECG. This study analyzes the effectiveness of mechanical CPR artefact suppression filters to rest...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9e53

    authors: Isasi I,Irusta U,Aramendi E,Idris AH,Sörnmo L

    更新日期:2020-11-06 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • Performance measurements of an infrared digital scanning laser ophthalmoscope.

    abstract::Direct digital acquisition of images using a scanning laser ophthalmoscope (SLO) offers several advantages over the conventional fundus camera; in particular, the ability to produce tomographic images using a confocal aperture. This note describes measurements of the performance of an SLO. Spatial resolution, measured...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/3/010

    authors: Manivannan A,Sharp PF,Forrester JV

    更新日期:1994-08-01 00:00:00

  • Microfluidics for flow cytometric analysis of cells and particles.

    abstract::This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvemen...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/26/3/R02

    authors: Huh D,Gu W,Kamotani Y,Grotberg JB,Takayama S

    更新日期:2005-06-01 00:00:00

  • Identification of oxygen-19 during in vivo neutron activation analysis of water phantoms.

    abstract::Hand bone equivalent phantoms (250 ml) carrying selenium in various amounts were irradiated and counted for in vivo neutron activation analysis (IVNAA) by employing a 4π NaI(TI) based detection system. During the analysis of counting data, a feature at a higher energy than the gamma ray peak from (77m)Se (0.162 MeV) w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/12/N127

    authors: Tahir SN,Chettle DR

    更新日期:2015-12-01 00:00:00

  • Effect of organic and inorganic nitrates on cerebrovascular pulsatile power transmission in patients with heart failure and preserved ejection fraction.

    abstract:OBJECTIVE:Increased penetration of pulsatile power to the brain has been implicated in the pathogenesis of age-related cognitive dysfunction and dementia, a common comorbidity in patients with heart failure and preserved ejection fraction (HFpEF). However, there is a lack of knowledge on the effects of organic and inor...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1361-6579/aab2ef

    authors: Londono-Hoyos F,Zamani P,Beraun M,Vasim I,Segers P,Chirinos JA

    更新日期:2018-04-20 00:00:00

  • Causality in physiological signals.

    abstract::Health is one of the most important non-material assets and thus also has an enormous influence on material values, since treating and preventing diseases is expensive. The number one cause of death worldwide today originates in cardiovascular diseases. For these reasons the aim of understanding the functions and the ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/37/5/R46

    authors: Müller A,Kraemer JF,Penzel T,Bonnemeier H,Kurths J,Wessel N

    更新日期:2016-05-01 00:00:00

  • An intelligent ventilation and oxygenation management system in neonatal intensive care using fuzzy trend template fitting.

    abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/019

    authors: Belal SY,Taktak AF,Nevill A,Spencer A

    更新日期:2005-08-01 00:00:00

  • Wearable oxygen uptake and energy expenditure monitors.

    abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab3827

    authors: Tamura T

    更新日期:2019-09-03 00:00:00

  • The influence of dilution on the offline measurement of exhaled nitric oxide.

    abstract:OBJECTIVE:Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The internati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa455

    authors: MacBean V,Pooranampillai D,Howard C,Lunt A,Greenough A

    更新日期:2018-02-26 00:00:00

  • Non-constrained monitoring of systolic blood pressure on a weighing scale.

    abstract::In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured usin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/011

    authors: Shin JH,Lee KM,Park KS

    更新日期:2009-07-01 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • Direct EIT Jacobian calculations for conductivity change and electrode movement.

    abstract::Electrical impedance tomography (EIT) is very sensitive to deformations of the medium boundary shape. For lung imaging, breathing and changes in posture move the electrodes and change the chest shape, resulting in image artefacts. Several approaches have been proposed to improve the reconstructed images; most methods ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S08

    authors: Gómez-Laberge C,Adler A

    更新日期:2008-06-01 00:00:00

  • PaCO2 measurement in cerebral haemodynamics: face mask or nasal cannulae?

    abstract:OBJECTIVE:PaCO2 affects cerebral blood flow (CBF) and its regulatory mechanisms, but the effects of CO2 measurement technique on cerebrovascular parameters are unknown. In order to determine if the two most commonly used approaches, face mask (FM) or nasal cannulae (NC), are interchangeable or not, we tested the hypoth...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa6f9f

    authors: Minhas JS,Robinson T,Panerai R

    更新日期:2017-06-22 00:00:00

  • Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration.

    abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab21af

    authors: Lucas BP,D'Addio A,Block C,Manning H,Remillard B,Leiter JC

    更新日期:2019-07-01 00:00:00

  • The physiological impact of the nonlinearity of arterial elasticity in the ambulatory arterial stiffness index.

    abstract::The ambulatory arterial stiffness index (AASI) is claimed to be a new estimator for arterial rigidity. It was recently defined as one minus the slope of the linear regression of systolic to diastolic ambulatory pressure during 24 h. Although several reports testify its clinical relevance, the explanation of how this n...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/7/012

    authors: Craiem D,Graf S,Salvucci F,Chironi G,Megnien JL,Simon A,Armentano RL

    更新日期:2010-07-01 00:00:00

  • Hidden Markov model-based activity recognition for toddlers.

    abstract:OBJECTIVE:Physical activity has been shown to impact future health outcomes in adults, but little is known about the long-term impact of physical activity in toddlers. Accurately measuring the specific types and amounts of physical activity in toddlers will help us to understand, predict, and better affect their future...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab6ebb

    authors: Albert MV,Sugianto A,Nickele K,Zavos P,Sindu P,Ali M,Kwon S

    更新日期:2020-03-06 00:00:00

  • New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

    abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/9/1624

    authors: Gade J,Greisen G

    更新日期:2016-09-01 00:00:00

  • In vivo quantification of accumulating abdominal fluid using an electrical impedance tomography hemiarray.

    abstract::A new method to image and quantify intra-abdominal haemorrhage using electrical impedance tomography (EIT) was tested in vivo. Supine peritoneal dialysis patients were monitored using an 8-electrode hemiarray placed on the anterior abdomen. EIT measurements were recorded using the EPack II data acquisition system befo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/2/001

    authors: Tucker AS,Ross EA,Paugh-Miller J,Sadleir RJ

    更新日期:2011-02-01 00:00:00

  • A finite element model of needle electrode spatial sensitivity.

    abstract::We used the finite element (FE) method to estimate the spatial sensitivity of a needle electrode for bioimpedance measurements. This current conducting needle with an insulated shaft was inserted in a saline solution and the current was measured at the neutral electrode. Model resistance and reactance were calculated ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/006

    authors: Høyum P,Kalvøy H,Martinsen ØG,Grimnes S

    更新日期:2010-10-01 00:00:00

  • Electroencephalogram classification in motor-imagery brain-computer interface applications based on double-constraint nonnegative matrix factorization.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba07b

    authors: Su J,Yang Z,Yan W,Sun W

    更新日期:2020-08-11 00:00:00

  • Storage effects on the Cole-Cole parameters of erythrocyte suspensions.

    abstract::Chemical alterations of red blood cells (RBCs) during storage eventually affect the electrical properties of blood. In this study, the physiological parameters such as extracellular (SAGM + CPD + residual plasma) Na(+), K(+), Cl(-), pH, 2,3-DPG and ATP together with the Cole-Cole parameters were measured using erythro...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/7/006

    authors: Sezdi M,Bayik M,Ulgen Y

    更新日期:2006-07-01 00:00:00

  • Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adults.

    abstract::The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expend...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa6d00

    authors: Ellingson LD,Hibbing PR,Kim Y,Frey-Law LA,Saint-Maurice PF,Welk GJ

    更新日期:2017-06-01 00:00:00

  • Body fat prediction from skinfold anthropometry referenced to a new gold standard: in vivo neutron activation analysis and tritium dilution.

    abstract::Skinfold anthropometry is a widely practiced technique often with little appreciation of its limitations. The large residual error appearing in any regressions of body density versus sums of skinfolds is primarily due to biological causes, in particular the non-constancy of the ratio of subcutaneous to total body fat....

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/19/3/008

    authors: Beddoe AH,Samat SB

    更新日期:1998-08-01 00:00:00