New porcine test-model reveals remarkable differences between algorithms for spectrophotometrical haemoglobin saturation measurements with VLS.

Abstract:

UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been described before. Seven pigs were used. They were perfused with cold Haemaxel, and thus killed, chilled and becoming bloodless. The bronchial artery was perfused with cold blood with known saturation and spectrophotometrical measurements were made through a bronchoscope. Based on 42 spectrophotometrical measurements of porcine bronchial mucosa saturation with fully oxygenated blood and 21 with de-oxygenated blood, six algorithms were applied to the raw-spectra of the measurements and compared with co-oxymetry. The difference from co-oxymetry in the oxygenated and de-oxygenated state ranged from  -32.8 to  +29.9 percentage points and from  -5.0 to  +9.2 percentage points, respectively. CONCLUSION:the algorithms showed remarkable in-between differences when tested on raw-spectra from an 'ex vivo' model. All algorithms had bias, more marked at high oxygenation than low oxygenation. Three algorithms were dis-recommended.

journal_name

Physiol Meas

authors

Gade J,Greisen G

doi

10.1088/0967-3334/37/9/1624

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

1624-35

issue

9

eissn

0967-3334

issn

1361-6579

journal_volume

37

pub_type

杂志文章
  • Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling tool.

    abstract::If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, ma...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/308

    authors: Bayford RH,Gibson A,Tizzard A,Tidswell T,Holder DS

    更新日期:2001-02-01 00:00:00

  • Identification of oxygen-19 during in vivo neutron activation analysis of water phantoms.

    abstract::Hand bone equivalent phantoms (250 ml) carrying selenium in various amounts were irradiated and counted for in vivo neutron activation analysis (IVNAA) by employing a 4π NaI(TI) based detection system. During the analysis of counting data, a feature at a higher energy than the gamma ray peak from (77m)Se (0.162 MeV) w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/12/N127

    authors: Tahir SN,Chettle DR

    更新日期:2015-12-01 00:00:00

  • Multiple breath washout analysis in infants: quality assessment and recommendations for improvement.

    abstract::Infant multiple breath washout (MBW) testing serves as a primary outcome in clinical studies. However, it is still unknown whether current software algorithms allow between-centre comparisons. In this study of healthy infants, we quantified MBW measurement errors and tried to improve data quality by simply changing so...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/3/L1

    authors: Anagnostopoulou P,Egger B,Lurà M,Usemann J,Schmidt A,Gorlanova O,Korten I,Roos M,Frey U,Latzin P

    更新日期:2016-03-01 00:00:00

  • AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch™ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.

    abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/12/005

    authors: Dick R,Penzel T,Fietze I,Partinen M,Hein H,Schulz J

    更新日期:2010-12-01 00:00:00

  • Circuit modeling of the electrical impedance: II. Normal subjects and system reproducibility.

    abstract::Part I of this series showed that the five-element circuit model accurately mimics impedances measured using multi-frequency electrical impedance myography (MFEIM), focusing on changes brought on by disease. This paper addresses two requirements which must be met if the method is to qualify for clinical use. First, th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/2/223

    authors: Shiffman CA,Rutkove SB

    更新日期:2013-02-01 00:00:00

  • Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study.

    abstract::In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major h...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/008

    authors: King J,Mochalski P,Kupferthaler A,Unterkofler K,Koc H,Filipiak W,Teschl S,Hinterhuber H,Amann A

    更新日期:2010-09-01 00:00:00

  • Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

    abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1785

    authors: Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

    更新日期:2016-10-01 00:00:00

  • Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.

    abstract::A coordinated study of the dispersal of water between the various body compartments (stomach and gut, blood stream and tissue) and the similar dispersal kinetics of ethanol and its metabolism has been carried out involving two healthy volunteers using flowing afterglow mass spectrometry, FA-MS, and selected ion flow t...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/011

    authors: Spanel P,Wang T,Smith D

    更新日期:2005-08-01 00:00:00

  • Auditory magnetic fields in cochlear-implant patients.

    abstract::Neuromagnetic recordings were used to check if electrical stimulation of the auditory nerve in cochlear-implant patients activates cortical auditory areas in a similar manner as acoustic stimulation in normal hearing subjects or whether the excitation processes are different. The waveform of the evoked magnetic field ...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/14/4a/014

    authors: Pelizzone M

    更新日期:1993-11-01 00:00:00

  • Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis.

    abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/009

    authors: Carter M,Morris AT,Zhu F,Zaluska W,Levin NW

    更新日期:2005-04-01 00:00:00

  • A shape-based quality evaluation and reconstruction method for electrical impedance tomography.

    abstract::Linear methods of reconstruction play an important role in medical electrical impedance tomography (EIT) and there is a wide variety of algorithms based on several assumptions. With the Graz consensus reconstruction algorithm for EIT (GREIT), a novel linear reconstruction algorithm as well as a standardized framework ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/6/1161

    authors: Antink CH,Pikkemaat R,Malmivuo J,Leonhardt S

    更新日期:2015-06-01 00:00:00

  • Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study.

    abstract::The purpose of this study was to examine the performance of dual-energy computed tomography (DECT) for the quantification of liver fat content (LFC). We prepared two phantoms: homogenized mixtures of porcine liver and fat and homogeneous mixtures of liver- and fat-equivalent solutions. Tubes containing mixtures with k...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/597

    authors: Li JH,Tsai CY,Huang HM

    更新日期:2014-04-01 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • Dynamic data monitoring improves predictive analytics for failed extubation in the ICU.

    abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aace95

    authors: Keim-Malpass J,Enfield KB,Calland JF,Lake DE,Clark MT

    更新日期:2018-07-16 00:00:00

  • Real time impedance plots with arbitrary frequency components.

    abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/1/008

    authors: Searle A,Kirkup L

    更新日期:1999-02-01 00:00:00

  • Characterization of the work-time relationship during cross-country ski ergometry.

    abstract::The purpose of this study was to examine the validity and reliability of estimated parameters of the work-time relationship during cross-country ski ergometry using the traditional multi-trial critical power (CP) test and a 3 min 'all-out' test (3MT). Fourteen recreationally active male participants (mean ± SD; age: 2...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/31

    authors: Fukuda DH,Hetrick RP,Kendall KL,Smith-Ryan AE,Jackson ME,Stout JR

    更新日期:2014-01-01 00:00:00

  • Differences in the microcirculatory effects of local skin surface contact pressure stimulation between acupoints and nonacupoints: possible relevance to acupressure.

    abstract::In the present study, laser Doppler measurement was used to quantitatively investigate the microcirculatory effects of contact pressure stimulation (PS) underneath the Hoku acupoint and its nearby nonacupoint, to improve the understanding of the mechanisms underlying acupressure therapy. A control group (no PS applied...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/6/007

    authors: Hsiu H,Hsu WC,Chen BH,Hsu CL

    更新日期:2010-06-01 00:00:00

  • The influence of cardiac preload and positive end-expiratory pressure on the pre-ejection period.

    abstract::The pre-ejection period (PEP) has recently been described as a potential parameter for monitoring cardiac preload. This study further investigated the influence of changes in intravascular volume status and the application of positive end-expiratory pressure (PEEP) on the pre-ejection period. In ten pigs, ECG, arteria...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/6/012

    authors: Kubitz JC,Kemming GI,Schultheib G,Starke J,Podtschaske A,Goetz AE,Reuter DA

    更新日期:2005-12-01 00:00:00

  • Potential neuroprotective effects of acupuncture stimulation on diabetes mellitus in a global ischemic rat model.

    abstract::Acupuncture (ACU) is known to be effective in ischemia treatment, and glutamate (GLU) excitotoxicity is an important factor in neuronal cell death. We observed the effect of ACU on cerebral blood flow (%CBF) and DeltaGLU (the changes in GLU release) in the ischemic stroke rat model of diabetic mellitus (DM). A global ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/5/003

    authors: Choi S,Lee GJ,Chae SJ,Kang SW,Yin CS,Lee SH,Choi SK,Park HK

    更新日期:2010-05-01 00:00:00

  • The variability of the photoplethysmographic signal--a potential method for the evaluation of the autonomic nervous system.

    abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/19/1/008

    authors: Nitzan M,Babchenko A,Khanokh B,Landau D

    更新日期:1998-02-01 00:00:00

  • Video-based respiration monitoring with automatic region of interest detection.

    abstract::Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration monitoring method that aut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/100

    authors: Janssen R,Wang W,Moço A,de Haan G

    更新日期:2016-01-01 00:00:00

  • Endocardial center motion for quantification of left ventricular discoordination in heart failure using cine MRI.

    abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaaa0

    authors: Saporito S,Houthuizen P,Aben JMM,Westenberg JJM,van Den Bosch HCM,van Assen HC,Mischi M

    更新日期:2018-02-28 00:00:00

  • Electroencephalogram classification in motor-imagery brain-computer interface applications based on double-constraint nonnegative matrix factorization.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba07b

    authors: Su J,Yang Z,Yan W,Sun W

    更新日期:2020-08-11 00:00:00

  • Gene expression signature of obesity in monozygotic twins.

    abstract:OBJECTIVE:Observational studies suggest that obesity might have a Mendelian origin, but it is not clear if gene expression patterns observed in obese subjects are secondary to genetic traits or not. APPROACH:Here we test a transcriptomic signature of obesity previously identified by our group on a large cohort of twin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aab85a

    authors: Font-Clos F,Zapperi S,La Porta CAM

    更新日期:2018-04-26 00:00:00

  • Inductive plethysmography components analysis and improved non-invasive postoperative apnoea monitoring.

    abstract::Twenty-nine patients were monitored overnight for breathing distress patterns during postoperative analgesia. Nasal flow apnoea monitoring and pulse oximetry data were recorded at 50 Hz. Respiratory inductive plethysmography (RIP) tracked tidal volume (TV) thoracoabdominal motion, and supplemented the flow monitoring ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/2/307

    authors: Millard RK

    更新日期:1999-05-01 00:00:00

  • A practical approach to storage and retrieval of high-frequency physiological signals.

    abstract:OBJECTIVE:Storage of physiological waveform data for retrospective analysis presents significant challenges. Resultant data can be very large, and therefore becomes expensive to store and complicated to manage. Traditional database approaches are not appropriate for large scale storage of physiological waveforms. Our g...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7cb5

    authors: Goodwin AJ,Eytan D,Greer RW,Mazwi M,Thommandram A,Goodfellow SD,Assadi A,Jegatheeswaran A,Laussen PC

    更新日期:2020-04-20 00:00:00

  • Characterization of cardiorespiratory phase synchronization and directionality in late premature and full term infants.

    abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac553

    authors: Lucchini M,Pini N,Fifer WP,Burtchen N,Signorini MG

    更新日期:2018-06-19 00:00:00

  • A measurement of pulmonary blood volume increase during systole in humans.

    abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/15/4/010

    authors: Nitzan M,Mahler Y,Schechter D,Yaffe S,Bocher M,Chisin R

    更新日期:1994-11-01 00:00:00