Abstract:
:Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F(-)) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almost completely in the skeleton making bone an ideal site for measurement to assess long-term exposure. This paper outlines a feasibility study of a technique to measure bone-fluorine non-invasively in the human hand using in vivo neutron activation analysis (IVNAA) via the (19)F(n,γ)(20)F reaction. Irradiations were performed using the Tandetron accelerator at McMaster University. Eight NaI(Tl) detectors arranged in a 4π geometry were employed for delayed counting of the emitted 1.63 MeV gamma ray. The short 11 s half-life of (20)F presents a difficult and unique practical challenge in terms of patient irradiation and subsequent detection. We have employed two simultaneous timing methods to determine the fluorine sensitivity by eliminating the interference of the 1.64 MeV gamma ray from the (37)Cl(n,γ)(38)Cl reaction. The timing method consisted of three counting periods: an initial 30 s (sum of three 10 s periods) count period for F, followed by a 120 s decay period, and a subsequent 300 s count period to obtain information pertaining to Ca and Cl. The phantom minimum detectable limit (M(DL)) determined by this method was 0.96 mg F/g Ca. The M(DL) was improved by dividing the initial timing period into three equal segments (10 s each) and combining the results using inverse variance weighting. This resulted in a phantom M(DL) of 0.66 mg F/g Ca. These detection limits are comparable to ex vivo results for various bones in the adult skeleton reported in the literature. Dosimetry was performed for these irradiation conditions. The equivalent dose for each phantom measurement was determined to be 30 mSv. The effective dose was however low, 35 µSv, which is comparable to other clinical diagnostic tools. The M(DL), relatively low radiation dose and non-invasiveness indicate the suitability of this method for routine in vivo analysis of bone-fluorine content. This prompted us to perform a trial study in human subjects. A preliminary human study on 34 participants was completed, with 33 of the 34 measurements proving to be successful. The in vivo M(DL) based on the improved timing method was determined to be 0.69 mg F/g Ca for the 33 successful human measurements. In our opinion, this technique has been demonstrated to be a suitable method for in vivo assessment of fluorine bone-burden.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Chamberlain M,Gräfe JL,Byun SH,Chettle DR,Egden LM,Orchard GM,Webber CE,McNeill FEdoi
10.1088/0967-3334/33/2/243subject
Has Abstractpub_date
2012-02-01 00:00:00pages
243-57issue
2eissn
0967-3334issn
1361-6579journal_volume
33pub_type
临床试验,杂志文章abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/20/1/008
更新日期:1999-02-01 00:00:00
abstract::When used in large, national surveillance programmes, objective measurement tools provide prevalence estimates of low physical activity guideline compliance and high amounts of sedentary time. There are undoubtedly a plethora of reasons for this but one possible contributing factor is the current lack of behavioural c...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/10/1834
更新日期:2016-10-01 00:00:00
abstract:BACKGROUND AND OBJECTIVE:Walking is a complex human behavior, usually performed in a dynamic environment. Gait parameters are thought to reflect this complexity. Re-Step™ is a therapy system in the form of a computerized shoe, originally developed for the training and rehabilitation of individuals with brain damage. Th...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/1361-6579/aab659
更新日期:2018-04-26 00:00:00
abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/4/N01
更新日期:2010-04-01 00:00:00
abstract:OBJECTIVE:In this paper, a support vector machine (SVM) approach using statistical features, P wave absence, spectrum features, and length-adaptive entropy are presented to classify ECG rhythms as four types: normal rhythm, atrial fibrillation (AF), other rhythm, and too noisy to classify. APPROACH:The proposed algori...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac7aa
更新日期:2018-06-25 00:00:00
abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/12/2529
更新日期:2014-12-01 00:00:00
abstract::Electrical impedance endotomography (EIE) is a modality of impedance imaging where the electrodes are located on an insulating core placed at the centre of the region of interest. The absence of a physical limit to the medium surrounding the probe enables the use of remote electrodes. The present study compares the fe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/4/001
更新日期:2005-08-01 00:00:00
abstract::The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/040
更新日期:2004-02-01 00:00:00
abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/29/7/008
更新日期:2008-07-01 00:00:00
abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...
journal_title:Physiological measurement
pub_type: 历史文章,杂志文章,评审
doi:10.1088/0967-3334/31/1/R01
更新日期:2010-01-01 00:00:00
abstract::Skinfold anthropometry is a widely practiced technique often with little appreciation of its limitations. The large residual error appearing in any regressions of body density versus sums of skinfolds is primarily due to biological causes, in particular the non-constancy of the ratio of subcutaneous to total body fat....
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/19/3/008
更新日期:1998-08-01 00:00:00
abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab3827
更新日期:2019-09-03 00:00:00
abstract::Myoelectrical pattern classification is a crucial part in multi-functional prosthesis control. This paper investigates a discriminant Fourier-derived cepstrum (DFC) and feature-level post-processing (FLPP) to discriminate hand and wrist motions using the surface electromyographic signal. The Fourier-derived cepstrum t...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/12/008
更新日期:2009-12-01 00:00:00
abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/001
更新日期:2004-02-01 00:00:00
abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/4/401
更新日期:2001-11-01 00:00:00
abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab21af
更新日期:2019-07-01 00:00:00
abstract:OBJECTIVE:Arterial CO2 (PaCO2) has a strong effect on cerebral blood flow (CBF), but its influence on CBF regulatory mechanisms and circulatory systemic variables has not been fully described over the entire physiological range of PaCO2. APPROACH:CBF velocity (CBFV, transcranial Doppler), blood pressure (BP, Finometer...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac76b
更新日期:2018-06-19 00:00:00
abstract::Generalizability theory was used to investigate the score consistency of observed extracellular fluid/intracellular fluid (ECF/ICF) ratio measurements for both the global and leg-segmental bio-impedance spectroscopy methods. The test instrument used was a Xitron Hydra ECF/ICF Bio-Impedance Analyzer System, model 4200 ...
journal_title:Physiological measurement
pub_type: 杂志文章,随机对照试验
doi:10.1088/0967-3334/27/4/005
更新日期:2006-04-01 00:00:00
abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/030
更新日期:2004-02-01 00:00:00
abstract:OBJECTIVE:PaCO2 affects cerebral blood flow (CBF) and its regulatory mechanisms, but the effects of CO2 measurement technique on cerebrovascular parameters are unknown. In order to determine if the two most commonly used approaches, face mask (FM) or nasal cannulae (NC), are interchangeable or not, we tested the hypoth...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aa6f9f
更新日期:2017-06-22 00:00:00
abstract::Electrical impedance tomography (EIT) has the potential to become a new tool for bedside monitoring of regional lung ventilation. The aim of our study was to assess the reproducibility of regional lung ventilation distribution determined by EIT during mechanical ventilation under identical ventilator settings. The exp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/7/S19
更新日期:2007-07-01 00:00:00
abstract::Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/9/007
更新日期:2006-09-01 00:00:00
abstract::The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, wa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/11/2307
更新日期:2014-11-01 00:00:00
abstract::We tested the hypothesis that transmission of arterial pressure to brain tissue oxygenation is low under conditions of arterial pressure instability. Two experimental models of hemodynamic instability were used in healthy human volunteers; (1) oscillatory lower body negative pressure (OLBNP) (N = 8; 5 male, 3 female),...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/4/785
更新日期:2015-04-01 00:00:00
abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/12/F01
更新日期:2011-12-01 00:00:00
abstract::Analysis of human eye pupil reactivity is a very valuable diagnostic method used mainly for evaluation of the condition of the autonomic nervous system and the visual system. The paper presents an experimental pupillometer built in the Institute of Physics of the Wroclaw University of Technology. The apparatus makes i...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/1/006
更新日期:2007-01-01 00:00:00
abstract::Health is one of the most important non-material assets and thus also has an enormous influence on material values, since treating and preventing diseases is expensive. The number one cause of death worldwide today originates in cardiovascular diseases. For these reasons the aim of understanding the functions and the ...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/0967-3334/37/5/R46
更新日期:2016-05-01 00:00:00
abstract::A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/24/2/357
更新日期:2003-05-01 00:00:00
abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/3/010
更新日期:2005-06-01 00:00:00
abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/20/3/304
更新日期:1999-08-01 00:00:00