Abstract:
:Patients with claudication have an inadequate haemodynamic response to exercise. Blood flow response will not only have a magnitude, but also a rate of change. There is scope for investigating these parameters, as manipulation of the factors which control them may benefit work to improve the treatment for claudication. This work compares the responses for patients with one normal limb and one with intermittent claudication. A custom-built ergometer allows unilateral, infragenicular plantar flexion exercise, whilst common femoral artery blood flow can be measured continuously by Duplex ultrasound. This apparatus was used to measure blood flow before, at the onset of and during a 5 W square-wave exercise stimulus in 15 patients. The claudicant group had a mean steady-state gain that was approximately half that of the normal group at around 170 ml min(-1) (p < 0.001) and a response time that was much shorter (p = 0.006). A mean response time of 21.0 +/- 1.4 s was achieved in claudicant limbs compared to 31.8 +/- 2.9 s in normals. However, the average rate of change of blood flow during this response time was estimated to still be greater for the normal group, at 431.7 +/- 47.1 ml min(-2), than for the claudicant group. The differences in magnitude and rate of change of limb blood flow response to exercise in claudicants were significant and may have implications for the treatment of claudication.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Meeson S,Srodon PDdoi
10.1088/0967-3334/26/6/002subject
Has Abstractpub_date
2005-12-01 00:00:00pages
903-10issue
6eissn
0967-3334issn
1361-6579pii
S0967-3334(05)99161-2journal_volume
26pub_type
临床试验,杂志文章abstract::Gastro-oesophageal pH measurements are routinely carried out to quantify and determine if levels of acid reflux are responsible for symptoms. Although considered the 'gold standard', evidence suggests that pH measurements do not correlate well with the degree of oesophagitis seen during endoscopy. In this study the cu...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/24/4/006
更新日期:2003-11-01 00:00:00
abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab7ddf
更新日期:2020-04-17 00:00:00
abstract::Muscle injuries in the lower limb are common among professional football players. Classification is made according to severity and is diagnosed with radiological assessment as: grade I (minor strain or minor injury), grade II (partial rupture, moderate injury) and grade III (complete rupture, severe injury). Tetrapola...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/1/27
更新日期:2015-01-01 00:00:00
abstract:OBJECTIVE:Observational studies suggest that obesity might have a Mendelian origin, but it is not clear if gene expression patterns observed in obese subjects are secondary to genetic traits or not. APPROACH:Here we test a transcriptomic signature of obesity previously identified by our group on a large cohort of twin...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aab85a
更新日期:2018-04-26 00:00:00
abstract::We have developed an eight-channel telemetry system for studying experimental models of chronic cardiovascular disease. The system is an extension of a previous device that has been miniaturized, reduced in power consumption and provided with increased functionality. We added sensors for ventricular dimension, and cor...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/3/002
更新日期:2007-03-01 00:00:00
abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2/002
更新日期:1994-05-01 00:00:00
abstract:UNLABELLED:The study created an 'ex vivo' model to test different algorithms for measurements of mucosal haemoglobin saturation with visible light spectrophotometry (VLS). The model allowed comparison between algorithms, but it also allowed comparison with co-oximetry using a 'gold standard' method. This has not been d...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/37/9/1624
更新日期:2016-09-01 00:00:00
abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/011
更新日期:2007-05-01 00:00:00
abstract::Electrical impedance tomography (EIT) measures the conductivity distribution within an object based on the current applied and voltage measured at surface electrodes. Thus, EIT images are sensitive to electrode properties (i.e. contact impedance, electrode area and boundary shape under the electrode). While some of th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/7/S02
更新日期:2011-07-01 00:00:00
abstract::Current methods for analysing foetal heart rate (FHR) patterns have yet to meet their full potential in the recognition of hypoxia in the foetus. Following the recent suggestion that fractal analysis can be applied to FHR recordings, the current paper describes a method for distinguishing two simultaneous fractal dime...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/14/3/009
更新日期:1993-08-01 00:00:00
abstract::The transthoracic electrical impedance is an important defibrillation parameter, affecting the defibrillating current amplitude and energy, and therefore the defibrillation efficiency. A close relationship between transthoracic impedance and defibrillation success rate was observed. Pre-shock measurements (using low a...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/21/1/318
更新日期:2000-02-01 00:00:00
abstract::A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcut...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/4/010
更新日期:2004-08-01 00:00:00
abstract::This study compared sitting time measured by a questionnaire (International Physical Activity Questionnaire; IPAQ) with concurrently measured objective sitting time from an accelerometer-based measure of thigh inclination (activPAL).Adults (n = 69), wore an activPAL for a week, and then completed the long-form 7 d rec...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/11/2319
更新日期:2014-11-01 00:00:00
abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/15/4/010
更新日期:1994-11-01 00:00:00
abstract::In this study, a framework for the characterization of the dynamic interactions between RR variability (RRV) and systolic arterial pressure variability (SAPV) is proposed. The methodology accounts for the intrinsic non-stationarity of the cardiovascular system and includes the assessment of both the strength and the p...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/3/315
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...
journal_title:Physiological measurement
pub_type: 杂志文章,评审
doi:10.1088/1361-6579/ab02ab
更新日期:2019-02-26 00:00:00
abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/2/004
更新日期:2006-02-01 00:00:00
abstract::In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphol...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1491
更新日期:2012-09-01 00:00:00
abstract::The outflow conductance (C(out)) of the cerebrospinal fluid (CSF) system is a parameter considered to be predictive in selection for hydrocephalus surgery. C(out) can be determined through an infusion test. A new apparatus for performing infusion tests in a standardized and automated way was developed. The objective w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/26/6/022
更新日期:2005-12-01 00:00:00
abstract::Skinfold anthropometry is a widely practiced technique often with little appreciation of its limitations. The large residual error appearing in any regressions of body density versus sums of skinfolds is primarily due to biological causes, in particular the non-constancy of the ratio of subcutaneous to total body fat....
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/19/3/008
更新日期:1998-08-01 00:00:00
abstract::Active locomotion of wireless capsule endoscopes has the potential to improve the diagnostic yield of this painless technique for the diagnosis of gastrointestinal tract disease. In order to design effective locomotion mechanisms, a quantitative measure of the propelling force required to effectively move a capsule in...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/7/1197
更新日期:2014-07-01 00:00:00
abstract::Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comp...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/6/1119
更新日期:2015-06-01 00:00:00
abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/12/005
更新日期:2010-12-01 00:00:00
abstract::It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance anal...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/1/011
更新日期:2004-02-01 00:00:00
abstract::A photoacoustic technique is used for studying topically applied substance absorption in human skin. The proposed method utilizes a double-chamber PA cell. The absorption determination was obtained through the measurement of the thermal effusivity of the binary system substance-skin. The theoretical model assumes that...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/23/3/304
更新日期:2002-08-01 00:00:00
abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/22/4/401
更新日期:2001-11-01 00:00:00
abstract:OBJECTIVE:Physical activity has been shown to impact future health outcomes in adults, but little is known about the long-term impact of physical activity in toddlers. Accurately measuring the specific types and amounts of physical activity in toddlers will help us to understand, predict, and better affect their future...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab6ebb
更新日期:2020-03-06 00:00:00
abstract::Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/4/517
更新日期:2014-04-01 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are aimed at providing a new way of communication between the human brain and external devices. One of the major tasks associated with the BCI system is to improve classification performance of the motor imagery (MI) signal. Electroencephalogram (EEG) signals are widely used f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aba07b
更新日期:2020-08-11 00:00:00
abstract::A simple wearable device for sit-to-stand timing detection was designed and constructed with rate gyroscopes and accelerometers and a dedicated adaptive algorithm. The method was validated by comparison with optoelectronic equipment. Results from the comparison showed a maximal error always lower than 2.5 x 10(-2) s f...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/8/006
更新日期:2006-08-01 00:00:00