Invasive and noninvasive means of measuring intracranial pressure: a review.

Abstract:

:Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space around the brain, where it is reabsorbed into the venous system. If the fluid does not drain out of the brain or get reabsorbed, the ICP increases, which may lead to brain damage or death. ICP elevation accompanied by dilatation of the cerebral ventricles is termed hydrocephalus, whereas ICP elevation accompanied by normal or small ventricles is termed idiopathic intracranial hypertension. OBJECTIVE:We performed a comprehensive literature review on how to measure ICP invasively and noninvasively. APPROACH:This review discusses the advantages and disadvantages of current invasive and noninvasive approaches. MAIN RESULTS:Invasive methods remain the most accurate at measuring ICP, but they are prone to a variety of complications including infection, hemorrhage and neurological deficits. Ventricular catheters remain the gold standard but also carry the highest risk of complications, including difficult or incorrect placement. Direct telemetric intraparenchymal ICP monitoring devices are a good alternative. Noninvasive methods for measuring and evaluating ICP have been developed and classified in five broad categories, but have not been reliable enough to use on a routine basis. These methods include the fluid dynamic, ophthalmic, otic, and electrophysiologic methods, as well as magnetic resonance imaging, transcranial Doppler ultrasonography (TCD), cerebral blood flow velocity, near-infrared spectroscopy, transcranial time-of-flight, spontaneous venous pulsations, venous ophthalmodynamometry, optical coherence tomography of retina, optic nerve sheath diameter (ONSD) assessment, pupillometry constriction, sensing tympanic membrane displacement, analyzing otoacoustic emissions/acoustic measure, transcranial acoustic signals, visual-evoked potentials, electroencephalography, skull vibrations, brain tissue resonance and the jugular vein. SIGNIFICANCE:This review provides a current perspective of invasive and noninvasive ICP measurements, along with a sense of their relative strengths, drawbacks and areas for further improvement. At present, none of the noninvasive methods demonstrates sufficient accuracy and ease of use while allowing continuous monitoring in routine clinical use. However, they provide a realizable ICP measurement in specific patients especially when invasive monitoring is contraindicated or unavailable. Among all noninvasive ICP measurement methods, ONSD and TCD are attractive and may be useful in selected settings though they cannot be used as invasive ICP measurement substitutes. For a sufficiently accurate and universal continuous ICP monitoring method/device, future research and developments are needed to integrate further refinements of the existing methods, combine telemetric sensors and/or technologies, and validate large numbers of clinical studies on relevant patient populations.

journal_name

Physiol Meas

authors

Zhang X,Medow JE,Iskandar BJ,Wang F,Shokoueinejad M,Koueik J,Webster JG

doi

10.1088/1361-6579/aa7256

subject

Has Abstract

pub_date

2017-07-24 00:00:00

pages

R143-R182

issue

8

eissn

0967-3334

issn

1361-6579

journal_volume

38

pub_type

杂志文章
  • Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

    abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/367

    authors: Lee BI,Oh SH,Woo EJ,Lee SY,Cho MH,Kwon O,Seo JK,Baek WS

    更新日期:2003-05-01 00:00:00

  • The contribution of vascular smooth muscle, elastin and collagen on the passive mechanics of porcine carotid arteries.

    abstract::The main components responsible for the mechanical behavior of the arterial wall are collagen, elastin, and smooth muscle cells (SMCs) in the medial layer. We determined the structural and mechanical changes in porcine carotid arteries after administration of Triton® X-100, elastase, and collagenase using the inflatio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/8/1335

    authors: Kochová P,Kuncová J,Svíglerová J,Cimrman R,Miklíková M,Liška V,Tonar Z

    更新日期:2012-08-01 00:00:00

  • Esophageal temperature monitoring during radiofrequency catheter ablation: experimental study based on an agar phantom model.

    abstract::Although previous studies have established the feasibility of monitoring esophageal temperature during radiofrequency cardiac ablation using an esophageal temperature probe (ETP), some questions remain regarding its efficacy. The aims of this study were to study the effect of the location of the ETP on the temperature...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/5/001

    authors: Rodríguez I,Lequerica JL,Berjano EJ,Herrero M,Hornero F

    更新日期:2007-05-01 00:00:00

  • Head and pelvis stride-to-stride oscillations in gait: validation and interpretation of measurements from wearable accelerometers.

    abstract::Unstable gait is a risk factor for falls. Wearable accelerometers enable remote monitoring of daily walking. Here, new methods for measuring stride-to-stride oscillations are validated against optical motion capture, normative data determined, and dependency on walking speed investigated. Walks by 13 young people (mea...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/857

    authors: Brodie MA,Beijer TR,Canning CG,Lord SR

    更新日期:2015-05-01 00:00:00

  • The linearity and reliability of the mechanomyographic amplitude versus submaximal isometric force relationship.

    abstract::The purpose of this study was to investigate the linearity and reliability of the mechanomyographic (MMG) amplitude versus submaximal isometric force relationship for the vastus lateralis. Twenty healthy subjects (mean +/- SD age = 24.0 +/- 4.3 years) volunteered to perform submaximal isometric muscle actions of the d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/10/002

    authors: Beck TW,DeFreitas JM,Stock MS

    更新日期:2009-10-01 00:00:00

  • Reproducibility of regional lung ventilation distribution determined by electrical impedance tomography during mechanical ventilation.

    abstract::Electrical impedance tomography (EIT) has the potential to become a new tool for bedside monitoring of regional lung ventilation. The aim of our study was to assess the reproducibility of regional lung ventilation distribution determined by EIT during mechanical ventilation under identical ventilator settings. The exp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S19

    authors: Frerichs I,Schmitz G,Pulletz S,Schädler D,Zick G,Scholz J,Weiler N

    更新日期:2007-07-01 00:00:00

  • AASM standards of practice compliant validation of actigraphic sleep analysis from SOMNOwatch™ versus polysomnographic sleep diagnostics shows high conformity also among subjects with sleep disordered breathing.

    abstract::In recent AASM practice, parameter actimetry is cited to measure total sleep time in obstructive sleep apnoea patients, when polysomnography is not available. An actigraph was therefore compared to polysomnographic data in 28 subjects with known sleep disordered breathing. Total sleep time (TST), sleep period time (SP...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/12/005

    authors: Dick R,Penzel T,Fietze I,Partinen M,Hein H,Schulz J

    更新日期:2010-12-01 00:00:00

  • Comparison of different passive knee extension torque-angle assessments.

    abstract::Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to wh...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1483

    authors: Freitas SR,Vaz JR,Bruno PM,Valamatos MJ,Mil-Homens P

    更新日期:2013-11-01 00:00:00

  • Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristics.

    abstract::The assessment and diagnosis of lower limb peripheral arterial occlusive disease (PAOD) is important since it can lead progressively to disabling claudication, ischaemic rest pain and gangrene. Historically, the first assessment has been palpation of the peripheral pulse since it can become damped, delayed and diminis...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/018

    authors: Allen J,Oates CP,Lees TA,Murray A

    更新日期:2005-10-01 00:00:00

  • Modelling of the immunoassay element of an optical immunosensor.

    abstract::Several factors affect the viability of biosensor design. A computer-based model is being developed to enable the sources and effect of noise and variability within the sensor to be analysed. The work now presented details the modelling of the biochemical aspect of the biosensor model-the immunoassay. The equilibrium ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/3/318

    authors: Keating SM,Flanagan MT

    更新日期:2001-08-01 00:00:00

  • Gastric activity studies using a magnetic tracer.

    abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/5/015

    authors: Cordova-Fraga T,Bernal-Alvarado JJ,Gutierrez-Juarez G,Sosa M,Vargas-Luna M

    更新日期:2004-10-01 00:00:00

  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00

  • Electroencephalography as a predictor of self-report fatigue/sleepiness during monotonous driving in train drivers.

    abstract:OBJECTIVE:In this study, electroencephalography activity recorded during monotonous driving was investigated to examine the predictive capability of monopolar EEG analysis for fatigue/sleepiness in a cohort of train drivers. APPROACH:Sixty-three train drivers participated in the study, where 32- lead monopolar EEG dat...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae42e

    authors: Lees T,Chalmers T,Burton D,Zilberg E,Penzel T,Lal S,Lal S

    更新日期:2018-10-30 00:00:00

  • False alarms during patient monitoring in clinical intensive care units are highly related to poor quality of the monitored electrocardiogram signals.

    abstract::Electrocardiograms (ECGs) recorded from patients in intensive care were investigated to quantify any relationship between ECG signal quality and false monitoring alarms. False alarms are a considerable problem for nursing and medical staff as they distract from clinical care, and are also a problem for patients as the...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1383

    authors: Tsimenidis C,Murray A

    更新日期:2016-08-01 00:00:00

  • Effects of CO2 on dynamic cerebral autoregulation measurement.

    abstract::Arterial pCO2 is known to influence cerebral autoregulation but its effect on the dynamic relationship between mean arterial blood pressure (ABP) and mean cerebral blood flow velocity (CBFV), obtained from spontaneous fluctuations in ABP, has not been established. In 16 normal subjects, ABP was measured non-invasively...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/20/3/304

    authors: Panerai RB,Deverson ST,Mahony P,Hayes P,Evans DH

    更新日期:1999-08-01 00:00:00

  • Effect of composition on the dielectric properties of hydrogels for biomedical applications.

    abstract::The effect of composition on the dielectric properties of hydrogels for biomedical applications is experimentally investigated. The hydrogels, containing hydroxyethylcellulose (HEC), are characterized by means of the impedance spectroscopy technique. The real and imaginary parts of the electrical impedance of the hydr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/S02

    authors: Alexe-Ionescu AL,Barbero G,Freire FC,Merletti R

    更新日期:2010-10-01 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms.

    abstract::A finite difference model of the human thorax with 113,400 control volumes (nodes) based on ECG gated MRI images was used to evaluate the Sheffield DAS-01P EIT system. Sixteen simulated electrode positions equally spaced around the thorax model at approximately the fourth intercostals space level were selected. Pairs ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/357

    authors: Patterson RP,Zhang J

    更新日期:2003-05-01 00:00:00

  • Video-based respiration monitoring with automatic region of interest detection.

    abstract::Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration monitoring method that aut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/100

    authors: Janssen R,Wang W,Moço A,de Haan G

    更新日期:2016-01-01 00:00:00

  • Feasible assessment of recovery and cardiovascular health: accuracy of nocturnal HR and HRV assessed via ring PPG in comparison to medical grade ECG.

    abstract:OBJECTIVE:To validate the accuracy of the Oura ring in the quantification of resting heart rate (HR) and heart rate variability (HRV). BACKGROUND:Wearable devices have become comfortable, lightweight, and technologically advanced for assessing health behavior. As an example, the novel Oura ring integrates daily physic...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840a

    authors: Kinnunen H,Rantanen A,Kenttä T,Koskimäki H

    更新日期:2020-05-07 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Adverse effects of near current-electrode placement in non-invasive bio-impedance measurements.

    abstract::A major problem confronting application of impedance techniques to studies of disease is the extraction of intrinsic properties of the tissue from the measured impedances, which unavoidably involve geometric factors as well. Amongst the foremost are the sizes and locations of the measuring electrode arrays, and this p...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1513

    authors: Shiffman CA

    更新日期:2013-11-01 00:00:00

  • Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance.

    abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4/007

    authors: Netz J,Forner E,Haagemann S

    更新日期:1993-11-01 00:00:00

  • Analysis of the quality of wrist movement during a simple tracking task.

    abstract::Objective assessment of stroke-patients' ability to control arm movements is vital for evidence-based therapy and progress monitoring. This study compares three different indices to quantify the quality of wrist movement during a task involving tracking a target on a screen. Each method is assessed in terms of agreeme...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/8/011

    authors: Notley SV,Turk R,Pickering R,Simpson DM,Burridge JH

    更新日期:2007-08-01 00:00:00

  • Chasing the evidence: the influence of data segmentation on estimates of dynamic cerebral autoregulation.

    abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7ddf

    authors: Panerai RB,Intharakham K,Haunton V,Minhas JS,Llwyd O,Lam M,Salinet ASM,Nogueira RC,Katsogridakis E,Maggio P,Robinson TG

    更新日期:2020-04-17 00:00:00

  • Dynamic time warping and machine learning for signal quality assessment of pulsatile signals.

    abstract::In this work, we describe a beat-by-beat method for assessing the clinical utility of pulsatile waveforms, primarily recorded from cardiovascular blood volume or pressure changes, concentrating on the photoplethysmogram (PPG). Physiological blood flow is nonstationary, with pulses changing in height, width and morphol...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1491

    authors: Li Q,Clifford GD

    更新日期:2012-09-01 00:00:00

  • PET(CO2) measurement and feature extraction of capnogram signals for extubation outcomes from mechanical ventilation.

    abstract::Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However,...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/2/231

    authors: Rasera CC,Gewehr PM,Domingues AM

    更新日期:2015-02-01 00:00:00

  • Patient examinations using electrical impedance tomography--sources of interference in the intensive care unit.

    abstract::Electrical impedance tomography (EIT) is expected to become a valuable tool for monitoring mechanically ventilated patients due to its ability to continuously assess regional lung ventilation and aeration. Several sources of interference with EIT examinations exist in intensive care units (ICU). Our objectives are to ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/12/F01

    authors: Frerichs I,Pulletz S,Elke G,Gawelczyk B,Frerichs A,Weiler N

    更新日期:2011-12-01 00:00:00

  • Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

    abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab02ab

    authors: Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

    更新日期:2019-02-26 00:00:00