Hemodynamic evaluation in pregnancy: limitations of impedance cardiography.

Abstract:

:Impedance cardiography (ICG) has been proposed to estimate the stroke volume (SV) and cardiac output (CO) in various medical indications. The aim of this study was to explore the reliability of ICG during pregnancy with respect to SV and CO measurements. Blood pressure, heart rate and thoracic impedance were monitored during the course of pregnancy and related ICG patterns analyzed. We determined thoracic impedance (Z(0)), left ventricular ejection time (LVET) and the maximum value of the first derivative of the impedance waveform (dZ/dt)(max) beat-to-beat. The two main components of non-invasive SV estimation, LVET and (dZ/dt)(max), decreased in week 35 relative to week 12 by 7.6% ± 4.8% and by 36.0% ± 14.0%, respectively, based on a decrease in R-R interval of 9.9% ± 9.7%, whereas changes in Z(0) did not play a significant role. Furthermore, the decrease of (dZ/dt)(max) was greater in the third compared to the second trimester of pregnancy. Taking into account an 18.2% ± 6.8% body weight increase, the calculated SV decreased in week 35 relative to week 12 by 19.2% ± 14.3%. The normalized term ((dZ/dt)(max))/Z(0) explained 85-94% of the variance of SV change after week 20. These results were confirmed for fixed R-R interval at a constant value across the repeated measurements. Based on beat-to-beat analysis of the main components of non-invasive SV estimation by ICG, measured repeatedly throughout normal pregnancy, we conclude that SV calculations render invalid data. Our findings strongly suggest that CO cannot be reliably assessed with ICG in pregnant women.

journal_name

Physiol Meas

authors

Moertl MG,Schlembach D,Papousek I,Hinghofer-Szalkay H,Weiss EM,Lang U,Lackner HK

doi

10.1088/0967-3334/33/6/1015

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

1015-26

issue

6

eissn

0967-3334

issn

1361-6579

journal_volume

33

pub_type

杂志文章
  • Trabecular thickness measurement in cancellous bones: postmortem rat studies with the zoom-in micro-tomography technique.

    abstract::Using the cross-sectional images taken with the zoom-in micro-tomography technique, we measured trabecular thicknesses of femur bones in postmortem rats. Since the zoom-in micro-tomography technique is capable of high resolution imaging of a small local region inside a large subject, we were able to measure the trabec...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/5/008

    authors: Cho MH,Chun IK,Lee SC,Cho MH,Lee SY

    更新日期:2005-10-01 00:00:00

  • The effect of ambient air temperature on whole-body bioelectrical impedance.

    abstract::It has previously been shown that extreme changes in ambient air temperature can affect whole-body bioelectrical impedance. The purpose of this study was to determine if more moderate changes in ambient air temperature, such as those experienced in most laboratory settings, would also affect bioelectric impedance anal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/011

    authors: Buono MJ,Burke S,Endemann S,Graham H,Gressard C,Griswold L,Michalewicz B

    更新日期:2004-02-01 00:00:00

  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00

  • Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

    abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1785

    authors: Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

    更新日期:2016-10-01 00:00:00

  • Prediction of sustained harmonic walking in the free-living environment using raw accelerometry data.

    abstract:OBJECTIVE:Using raw, sub-second-level accelerometry data, we propose and validate a method for identifying and characterizing walking in the free-living environment. We focus on sustained harmonic walking (SHW), which we define as walking for at least 10 s with low variability of step frequency. APPROACH:We utilize th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaa74d

    authors: Urbanek JK,Zipunnikov V,Harris T,Fadel W,Glynn N,Koster A,Caserotti P,Crainiceanu C,Harezlak J

    更新日期:2018-02-28 00:00:00

  • Non-constrained monitoring of systolic blood pressure on a weighing scale.

    abstract::In this study, we developed a novel technique for estimating non-constrained and cuffless blood pressure (BP) that was based on electrocardiogram (ECG) and ballistocardiogram (BCG). The BCG was non-invasively measured using a common electronic weighing scale when a subject was standing on it. The ECG was measured usin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/011

    authors: Shin JH,Lee KM,Park KS

    更新日期:2009-07-01 00:00:00

  • Fetal beat detection in abdominal ECG recordings: global and time adaptive approaches.

    abstract::We present a method for location of fetal QRS in maternal abdominal ECG recordings. This method's initial, global approach was proposed in the context of the 2013 PhysioNet/Computing in Cardiology Challenge where it was tested on the 447 four channel one-minute recordings.The first step is filtering to eliminate basel...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1699

    authors: Rodrigues R

    更新日期:2014-08-01 00:00:00

  • Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance.

    abstract::Using a primary coil that induces eddy currents in a volume conductor, and a pair of secondary coils configured to form a differential transformer, it is possible to measure the conductivity of a volume conductor by the magnetic fields of the induced eddy currents. This method is especially favourable for measuring im...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/4/007

    authors: Netz J,Forner E,Haagemann S

    更新日期:1993-11-01 00:00:00

  • Multi-frequency imaging and modelling of respiratory related electrical impedance changes.

    abstract::Two studies concerning multi-frequency impedance measurements are presented. The first uses tetrapolar measurements made on the thorax and the second electrical impedance tomography images, also made from the thorax. The way in which the impedance and the changes in impedance with ventilation depend upon frequency are...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/001

    authors: Brown BH,Barber DC,Wang W,Lu L,Leathard AD,Smallwood RH,Hampshire AR,Mackay R,Hatzigalanis K

    更新日期:1994-05-01 00:00:00

  • Single-sector thermophysiological human simulator.

    abstract::Thermal sweating manikins are used to analyse the heat and mass transfer phenomena in the skin-clothing-environment system. However, the limiting factor of present thermal manikins is their inability to simulate adequately the human thermal behaviour, which has a significant effect on the clothing microenvironment. A ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/2/002

    authors: Psikuta A,Richards M,Fiala D

    更新日期:2008-02-01 00:00:00

  • Cardio-respiratory signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning.

    abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab525c

    authors: Chaichulee S,Villarroel M,Jorge J,Arteta C,McCormick K,Zisserman A,Tarassenko L

    更新日期:2019-12-02 00:00:00

  • Is dynamic cerebral autoregulation measurement using transcranial Doppler ultrasound reproducible in the presence of high concentration oxygen and carbon dioxide?

    abstract::Reliability of cerebral blood flow velocity (CBFV) and dynamic cerebral autoregulation estimates (expressed as autoregulation index: ARI) using spontaneous fluctuations in blood pressure (BP) has been demonstrated. However, reliability during co-administration of O2 and CO2 is unknown. Bilateral CBFV (using transcrani...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/5/673

    authors: Minhas JS,Syed NF,Haunton VJ,Panerai RB,Robinson TG,Mistri AK

    更新日期:2016-05-01 00:00:00

  • Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat.

    abstract::Easily applicable and inexpensive water-specific techniques to evaluate local oedema, swollen tissue problems and fluid retention in humans are not available. In the present investigation a recently constructed non-invasive device for a local measurement of changes in tissue water in human skin and subcutaneous fat (S...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/2/004

    authors: Nuutinen J,Ikäheimo R,Lahtinen T

    更新日期:2004-04-01 00:00:00

  • Combined electrocardiogram and photoplethysmogram measurements as an indicator of objective sleepiness.

    abstract::There is considerable interest in unobtrusive and portable methods of monitoring sleepiness outside the laboratory setting. This study evaluates the usefulness of combined electrocardiogram (ECG) and photoplethysmogram (PPG) measurements for estimating psychomotor vigilance. The psychomotor vigilance test (PVT) was pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/8/001

    authors: Chua CP,McDarby G,Heneghan C

    更新日期:2008-08-01 00:00:00

  • Detection of acute periodontal pain from physiological signals.

    abstract:OBJECTIVE:To investigate the feasibility of the detection of brief orofacial pain sensations from easily recordable physiological signals by means of machine learning techniques. APPROACH:A total of 47 subjects underwent periodontal probing and indicated each instance of pain perception by means of a push button. Simu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aadf0c

    authors: Teichmann D,Klopp J,Hallmann A,Schuett K,Wolfart S,Teichmann M

    更新日期:2018-09-27 00:00:00

  • Monitoring of body fluid redistribution using segmental bioimpedance during rotation on a short-radius centrifuge.

    abstract:OBJECTIVE:The creation of artificial gravity on board a space station is one of the promising methods for preventing health problems during space missions; a short-radius centrifuge (SRC) is the model of such a method on Earth. Our goal was to evaluate the sensitivity of bioimpedance polysegmental measurements for moni...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab840b

    authors: Takhtobina YV,Shchelykalina SP,Smirnov YI,Smirnov AV,Koloteva MI,Vassilieva GY,Nikolaev DV

    更新日期:2020-05-07 00:00:00

  • Effect of body mass index (BMI) on estimation of extracellular volume (ECV) in hemodialysis (HD) patients using segmental and whole body bioimpedance analysis.

    abstract::The aim of the study was to investigate whether body mass index (BMI) influences the estimation of extracellular volume (ECV) in hemodialysis (HD) patients when using segmental bioimpedance analysis (SBIA) compared to wrist-to-ankle bioimpedance analysis (WBIA) during HD with ultrafiltration (UF). Twenty five HD patie...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/26/2/009

    authors: Carter M,Morris AT,Zhu F,Zaluska W,Levin NW

    更新日期:2005-04-01 00:00:00

  • Classification of cognitive reserve in healthy older adults based on brain activity using support vector machine.

    abstract:OBJECTIVE:Cognitive reserve (CR) refers to the capacity of the brain to actively cope with damage via the implementation of remedial cognitive processes. Traditional CR measurements focus on static proxies, which may not be able to appropriately estimate dynamic changes in CR. This study therefore investigated the cogn...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab979e

    authors: Yang CY,Lin CP

    更新日期:2020-07-07 00:00:00

  • Specific heat capacity of freshly excised prostate specimens.

    abstract::The specific heat capacity of tissue is a critical parameter for thermal therapies that act over a long period of time. It is also critical for thermoacoustic signal generation. We present ex vivo measurements of specific heat capacity performed by a dual-pin probe with tight temperature control of the specimen. One 3...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/11/N02

    authors: Patch SK,Rao N,Kelly H,Jacobsohn K,See WA

    更新日期:2011-11-01 00:00:00

  • Electroencephalography as a predictor of self-report fatigue/sleepiness during monotonous driving in train drivers.

    abstract:OBJECTIVE:In this study, electroencephalography activity recorded during monotonous driving was investigated to examine the predictive capability of monopolar EEG analysis for fatigue/sleepiness in a cohort of train drivers. APPROACH:Sixty-three train drivers participated in the study, where 32- lead monopolar EEG dat...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aae42e

    authors: Lees T,Chalmers T,Burton D,Zilberg E,Penzel T,Lal S,Lal S

    更新日期:2018-10-30 00:00:00

  • Comparison of different passive knee extension torque-angle assessments.

    abstract::Previous studies have used isokinetic dynamometry to assess joint torques and angles during passive extension of the knee, often without reporting upon methodological errors and reliability outcomes. In addition, the reliability of the techniques used to measure passive knee extension torque-angle and the extent to wh...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/11/1483

    authors: Freitas SR,Vaz JR,Bruno PM,Valamatos MJ,Mil-Homens P

    更新日期:2013-11-01 00:00:00

  • EIT data noise evaluation in the clinical environment.

    abstract::In the clinical environment the reliable interpretation of EIT images depends on the quality of the data. In the electrically noisy hospital environment the system performance needs to be assessed for each clinical investigation. From the model of noise presented, a figure of merit for comparisons of system performanc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/006

    authors: Meeson S,Blott BH,Killingback AL

    更新日期:1996-11-01 00:00:00

  • Early prediction of unexplained syncope by support vector machines.

    abstract::The goal of the present study was to develop and evaluate a new method for the prediction of unexplained syncope occurrences. Diagnosis of syncope is currently based on the reproduction of symptoms in combination with hypotension and bradycardia induced by a 45 min 60-70 degrees head-upright tilt test (HUTT). The main...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/28/2/007

    authors: Schang D,Feuilloy M,Plantier G,Fortrat JO,Nicolas P

    更新日期:2007-02-01 00:00:00

  • Multimodal heart beat detection using signal quality indices.

    abstract::The electrocardiogram (ECG) is a well studied signal from which many clinically relevant parameters can be derived, such as heart rate. A key component in the estimation of these parameters is the accurate detection of the R peak in the QRS complex. While corruption of the ECG by movement artefact or sensor failure ca...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/8/1665

    authors: Johnson AE,Behar J,Andreotti F,Clifford GD,Oster J

    更新日期:2015-08-01 00:00:00

  • Identification of oxygen-19 during in vivo neutron activation analysis of water phantoms.

    abstract::Hand bone equivalent phantoms (250 ml) carrying selenium in various amounts were irradiated and counted for in vivo neutron activation analysis (IVNAA) by employing a 4π NaI(TI) based detection system. During the analysis of counting data, a feature at a higher energy than the gamma ray peak from (77m)Se (0.162 MeV) w...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/12/N127

    authors: Tahir SN,Chettle DR

    更新日期:2015-12-01 00:00:00

  • Empirically derived cut-points for sedentary behaviour: are we sitting differently?

    abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of  <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1669

    authors: Clarke-Cornwell AM,Farragher TM,Cook PA,Granat MH

    更新日期:2016-10-01 00:00:00

  • Variability in estimating shunt from single pulse oximetry measurements.

    abstract::Virtual shunt describes the overall loss of O2 content between the alveolar gas and arterial blood. Clinicians indirectly estimate the magnitude of the virtual shunt by monitoring peripheral blood oxygen saturation (SpO2) using non-invasive pulse oximetry. An inherent limitation of this method is the variable precisio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/5/967

    authors: Karlen W,Petersen CL,Dumont GA,Ansermino JM

    更新日期:2015-05-01 00:00:00

  • Patient-specific simulations and measurements of the magneto-hemodynamic effect in human primary vessels.

    abstract::This paper investigates the main characteristics of the magneto-hemodynamic (MHD) response for application as a biomarker of vascular blood flow. The induced surface potential changes of a volunteer exposed to a 3 T static B0 field of a magnetic resonance imaging (MRI) magnet were measured over time at multiple locati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/2/117

    authors: Kyriakou A,Neufeld E,Szczerba D,Kainz W,Luechinger R,Kozerke S,McGregor R,Kuster N

    更新日期:2012-02-01 00:00:00

  • Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes.

    abstract::A nonlinear model predictive controller has been developed to maintain normoglycemia in subjects with type 1 diabetes during fasting conditions such as during overnight fast. The controller employs a compartment model, which represents the glucoregulatory system and includes submodels representing absorption of subcut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/4/010

    authors: Hovorka R,Canonico V,Chassin LJ,Haueter U,Massi-Benedetti M,Orsini Federici M,Pieber TR,Schaller HC,Schaupp L,Vering T,Wilinska ME

    更新日期:2004-08-01 00:00:00

  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00