Daily physical activity patterns from hip- and wrist-worn accelerometers.

Abstract:

:Accelerometer wear location may influence physical activity estimates. This study investigates this relationship through the examination of activity patterns throughout the day. Participants from the aging research evaluating accelerometry (AREA) study (n men  =  37, n women  =  47, mean age (SD)  =  78.9 (5.5) years) were asked to wear accelerometers in a free-living environment for 7 d at three different wear locations; one on each wrist and one on the right hip. During waking hours, wrist-worn accelerometers consistently produced higher median activity counts, about 5  ×  higher, as well as wider variability compared to hip-worn monitors. However, the shape of the accrual pattern curve over the course of the day for the hip and wrist are similar; there is a spike in activity in the morning, with a prolonged tapering of activity level as the day progresses. The similar patterns of hip and wrist activity accrual provide support that each location is capable of estimating total physical activity volume. The examination of activity patterns over time may provide a more detailed way to examine differences in wear location and different subpopulations.

journal_name

Physiol Meas

authors

Shiroma EJ,Schepps MA,Harezlak J,Chen KY,Matthews CE,Koster A,Caserotti P,Glynn NW,Harris TB

doi

10.1088/0967-3334/37/10/1852

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

1852-1861

issue

10

eissn

0967-3334

issn

1361-6579

journal_volume

37

pub_type

杂志文章
  • Effect of composition on the dielectric properties of hydrogels for biomedical applications.

    abstract::The effect of composition on the dielectric properties of hydrogels for biomedical applications is experimentally investigated. The hydrogels, containing hydroxyethylcellulose (HEC), are characterized by means of the impedance spectroscopy technique. The real and imaginary parts of the electrical impedance of the hydr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/S02

    authors: Alexe-Ionescu AL,Barbero G,Freire FC,Merletti R

    更新日期:2010-10-01 00:00:00

  • Regional changes in cerebral blood flow oxygenation can indicate global changes in cerebral blood flow during coronary artery occlusion in juvenile pigs.

    abstract::Near infrared spectroscopy (NIRS) is a widely employed method for assessment of regional cerebral oxygenation (RcStO2). RcStO2 values are expected to vary with changes in the relative amount of oxyhaemoglobin. The present experimental study aimed to assess the response of RcStO2 to controlled alterations of carotid bl...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/7/1439

    authors: Svenmarker S,Häggmark S,Johansson G,Axelsson B,Wiklund U,Haney M

    更新日期:2014-07-01 00:00:00

  • Static conductivity imaging using variational gradient Bz algorithm in magnetic resonance electrical impedance tomography.

    abstract::A new image reconstruction algorithm is proposed to visualize static conductivity images of a subject in magnetic resonance electrical impedance tomography (MREIT). Injecting electrical current into the subject through surface electrodes, we can measure the induced internal magnetic flux density B = (Bx, By, Bz) using...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/030

    authors: Park C,Park EJ,Woo EJ,Kwon O,Seo JK

    更新日期:2004-02-01 00:00:00

  • Empirically derived cut-points for sedentary behaviour: are we sitting differently?

    abstract::Sedentary behaviour (SB) is associated with a number of adverse health outcomes. Studies that have used ActiGraph monitors to define sedentary time tend to use a threshold of  <100 counts per minute (cpm) for classifying SB; however, this cut-point was not empirically derived for adults. It is not known whether ActiGr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1669

    authors: Clarke-Cornwell AM,Farragher TM,Cook PA,Granat MH

    更新日期:2016-10-01 00:00:00

  • Empirical estimators of gamma fits to tracer-dilution curves and their technical basis and practical scope.

    abstract::A gamma fit facilitates smoothing and extrapolation of distorted tracer-dilution curves in blood flow studies. Theoretically based empirical estimators were developed as simple alternatives to direct regression approaches from simulated gamma distributions with a wide range of shape asymmetry. Key curve features of pe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/4/401

    authors: Lopatatzidis A,Millard RK

    更新日期:2001-11-01 00:00:00

  • Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adults.

    abstract::The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expend...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa6d00

    authors: Ellingson LD,Hibbing PR,Kim Y,Frey-Law LA,Saint-Maurice PF,Welk GJ

    更新日期:2017-06-01 00:00:00

  • An intelligent ventilation and oxygenation management system in neonatal intensive care using fuzzy trend template fitting.

    abstract::This paper describes an open loop feedback intelligent system for neonatal intensive care management. The system provides a tool enabling the user to make the final decision to accept or reject the advice given. The system collects 18 parameters from the bedside monitor and ventilator using a Medical Information Bus (...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/019

    authors: Belal SY,Taktak AF,Nevill A,Spencer A

    更新日期:2005-08-01 00:00:00

  • Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

    abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/367

    authors: Lee BI,Oh SH,Woo EJ,Lee SY,Cho MH,Kwon O,Seo JK,Baek WS

    更新日期:2003-05-01 00:00:00

  • An optimized lead system for long-term esophageal electrocardiography.

    abstract::Long-term electrocardiography (ECG) featuring adequate atrial and ventricular signal quality is highly desirable. Routinely used surface leads are limited in atrial signal sensitivity and recording capability impeding complete ECG delineation, i.e. in the presence of supraventricular arrhythmias. Long-term esophageal ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/517

    authors: Niederhauser T,Haeberlin A,Marisa T,Mattle D,Abächerli R,Goette J,Jacomet M,Vogel R

    更新日期:2014-04-01 00:00:00

  • Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    abstract::False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1298

    authors: Liu C,Zhao L,Tang H,Li Q,Wei S,Li J

    更新日期:2016-08-01 00:00:00

  • Characterization of cardiorespiratory phase synchronization and directionality in late premature and full term infants.

    abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac553

    authors: Lucchini M,Pini N,Fifer WP,Burtchen N,Signorini MG

    更新日期:2018-06-19 00:00:00

  • Correlation between maximal radial muscle displacement and stiffness in gastrocnemius muscle.

    abstract:OBJECTIVE:Tensiomyography (TMG) and myotonometry (MMT) are two novel technologies that measure neuromuscular properties. These two devices measure the stiffness of the soft tissue as well as other variables. The aim of this study is to analyze if there is any correlation between maximal radial displacement (Dm) and Sti...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abcdf4

    authors: Labata-Lezaun N,López-de-Celis C,Llurda-Almuzara L,González-Rueda V,Cadellans-Arróniz A,Pérez-Bellmunt A

    更新日期:2020-12-31 00:00:00

  • Hidden Markov model-based activity recognition for toddlers.

    abstract:OBJECTIVE:Physical activity has been shown to impact future health outcomes in adults, but little is known about the long-term impact of physical activity in toddlers. Accurately measuring the specific types and amounts of physical activity in toddlers will help us to understand, predict, and better affect their future...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab6ebb

    authors: Albert MV,Sugianto A,Nickele K,Zavos P,Sindu P,Ali M,Kwon S

    更新日期:2020-03-06 00:00:00

  • Classification of cognitive reserve in healthy older adults based on brain activity using support vector machine.

    abstract:OBJECTIVE:Cognitive reserve (CR) refers to the capacity of the brain to actively cope with damage via the implementation of remedial cognitive processes. Traditional CR measurements focus on static proxies, which may not be able to appropriately estimate dynamic changes in CR. This study therefore investigated the cogn...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab979e

    authors: Yang CY,Lin CP

    更新日期:2020-07-07 00:00:00

  • Eye-tracker algorithms to detect saccades during static and dynamic tasks: a structured review.

    abstract:OBJECTIVE:Eye-tracking devices have become widely used as clinical assessment tools in a variety of applied-scientific fields to measure saccadic eye movements. With the emergence of multiple static and dynamic devices, the concurrent need for algorithm development and validation is paramount. APPROACH:This review ass...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab02ab

    authors: Stuart S,Hickey A,Vitorio R,Welman K,Foo S,Keen D,Godfrey A

    更新日期:2019-02-26 00:00:00

  • Neural network analysis of oxygenation signals in infants during sleep.

    abstract::The use of artificial neural networks (ANNs) to interpret sleep monitoring signals is described. Recordings from ten infants with apparent life threatening episodes were assigned into training feedforward R-PROP networks. In order to separate good signal from artefact, 60 second time frames of SaO2 and TcPO2 signals w...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/21/3/401

    authors: Taktak AF,Simpson S,Patel S,Meyer G

    更新日期:2000-08-01 00:00:00

  • A comparative study of several exciting magnetic fields for induced current EIT.

    abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2a/007

    authors: Gençer NG,Ider YZ

    更新日期:1994-05-01 00:00:00

  • EITS changes following oleic acid induced lung water.

    abstract::We present the results of using electrical impedance tomographic spectroscopy (EITS) to follow the changes in lung water induced by oleic acid. Measurements were made on three goats before and after the injection of oleic acid. In addition to the EITs measurements, lung water was also measured using a double-indicator...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/016

    authors: Brown BH,Flewelling R,Griffiths H,Harris ND,Leathard AD,Lu L,Morice AH,Neufeld GR,Nopp P,Wang W

    更新日期:1996-11-01 00:00:00

  • Acute and chronic effects on central hemodynamics and arterial stiffness in professional rowers.

    abstract::Controversial data exist on acute and chronic effects of competitive sports on central hemodynamics and arterial stiffness. We investigated chronic as well as acute training effects in professional rowers. The trial was planned as a non-randomized, controlled pilot-study comparing athletes and controls. 13 German nati...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/4/544

    authors: Franzen K,Reppel M,Köster J,Mortensen K

    更新日期:2016-04-01 00:00:00

  • A comparison of technologies used for estimation of body temperature.

    abstract::Body temperature measurement is an important clinical parameter. The performance of a number of non-invasive thermometers was measured by comparing intra- and inter-operator variability (n = 100) and clinical accuracy (n = 61). Variability was elevated in febrile compared to normothermic subjects for axillary and oral...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/003

    authors: Mangat J,Standley T,Prevost A,Vasconcelos J,White P

    更新日期:2010-09-01 00:00:00

  • Multi-frequency parameter mapping of electrical impedance scanning using two kinds of circuit model.

    abstract::Electrical impedance scanning (EIS) is a kind of potential bio-impedance measurement technology, especially aiding the diagnosis of breast cancer in women. By changing the frequency of the driving signal in turn while keeping the other conditions stable, multi-frequency measurement results on the object can be obtaine...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S07

    authors: Liu R,Dong X,Fu F,You F,Shi X,Ji Z,Wang K

    更新日期:2007-07-01 00:00:00

  • Changes in cerebral hemodynamics during a sleep-deprived video-electroencephalogram in healthy children.

    abstract::This study investigates the cerebral hemodynamic changes during a routine sleep-deprived video-electroencephalogram (SD-VEEG) in healthy children. Forty-two children with normal intelligence were examined. The children were 5-14 years of age, and their electroencephalograms (EEGs) were within the normal range. Each su...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/7/981

    authors: Peng B,Li J,Wang J,Liang X,Zheng Z,Mai J

    更新日期:2016-07-01 00:00:00

  • A new method for measurement of gas exchange during anaesthesia using an extractable marker gas.

    abstract::A new method for the measurement of pulmonary gas exchange during inhalational anaesthesia is described which measures fresh gas and exhaust gas flows using carbon dioxide as an extractable marker gas. The theoretical precision of the method was compared by Monte Carlo modelling with other approaches which use marker ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/001

    authors: Peyton PJ,Robinson GJ,Terry D,Junor PA

    更新日期:2004-02-01 00:00:00

  • Measurements of fluorine in contemporary urban Canadians: a comparison of the levels found in human bone using in vivo and ex vivo neutron activation analysis.

    abstract::Non-invasive in vivo neutron activation analysis (NAA) was used to measure the fluorine concentration in 35 people in Hamilton, Ontario, Canada. Measurement and precision data of this second generation NAA system were determined in 2013, and the results were compared with the performance of a first generation system u...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/3/465

    authors: Mostafaei F,McNeill FE,Chettle DR,Wainman BC,Pidruczny AE,Prestwich WV

    更新日期:2015-03-01 00:00:00

  • A medical thermal imaging device for the prevention of diabetic foot ulceration.

    abstract::In this paper a description is given of the development, characterisation and first results of a thermal imaging device aimed at significantly reducing the incidence of diabetic foot ulceration (DFU). These devices will be used in three clinical centres and in two preliminary clinical trials. The first will be on heal...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa56b1

    authors: Machin G,Whittam A,Ainarkar S,Allen J,Bevans J,Edmonds M,Kluwe B,Macdonald A,Petrova N,Plassmann P,Ring F,Rogers L,Simpson R

    更新日期:2017-03-01 00:00:00

  • Validation of x-ray fluorescence measurements of metals in toenail clippings against inductively coupled plasma mass spectrometry in a Nigerian population.

    abstract:OBJECTIVE:Metal exposures have been linked with many adverse health outcomes affecting nearly every system in the body. Exposure to metals has been tracked primarily using blood. Blood metal concentrations have drawbacks as biomarkers stemming from the metals' short biologic half-lives, shipping and storage requirement...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aad947

    authors: Specht AJ,Kponee K,Nkpaa KW,Balcom PH,Weuve J,Nie LH,Weisskopf MG

    更新日期:2018-08-31 00:00:00

  • Adaptive filtering of ECG interference on surface EEnGs based on signal averaging.

    abstract::An external electroenterogram (EEnG) is the recording of the small bowel myoelectrical signal using contact electrodes placed on the abdominal surface. It is a weak signal affected by possible movements and by the interferences of respiration and, principally, of the cardiac signal. In this paper an adaptive filtering...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/6/005

    authors: Garcia-Casado J,Martinez-de-Juan JL,Ponce JL

    更新日期:2006-06-01 00:00:00

  • Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.

    abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/4/N01

    authors: Dellacà RL,Gobbi A,Pastena M,Pedotti A,Celli B

    更新日期:2010-04-01 00:00:00

  • Impedance analyser module for EIT and spectroscopy using undersampling.

    abstract::In this paper we present the concept, the design and the test procedure for a DSP-based high-precision and high-performance wide-band (up to 10 MHz) bioimpedance analyser module for application in EIT or bioimpedance spectroscopy. The module implements a digital concept with appropriate signal conditioning hardware fo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/303

    authors: Dudykevych T,Gersing E,Thiel F,Hellige G

    更新日期:2001-02-01 00:00:00

  • Time-frequency analysis of heart rate variability using short-time fourier analysis.

    abstract::This study was done to introduce new parameters derived by time frequency analysis of heart rate variability data. Four simulation experiments were carried out to compare the short-time Fourier transform (STFT) analysis method to the traditional overall spectral analysis method. Sinusoidal signals were generated with ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/21/2/303

    authors: Elsenbruch S,Wang Z,Orr WC,Chen JD

    更新日期:2000-05-01 00:00:00