Abstract:
BACKGROUND:Uterine activity monitoring is an essential part of managing the progress of pregnancy and labor. Although intrauterine pressure (IUP) is the only reliable method of estimating uterine mechanical activity, it is highly invasive. Since there is a direct relationship between the electrical and mechanical activity of uterine cells, surface electrohysterography (EHG) has become a noninvasive monitoring alternative. The Teager energy (TE) operator of the EHG signal has been used for IUP continuous pressure estimation, although its accuracy could be improved. We aimed to develop new optimized IUP estimation models for clinical application. APPROACH:We first considered enhancing the optimal estimation of IUP clinical features (maximum pressure and tonus) rather than optimizing the signal only (continuous pressure). An adaptive algorithm was also developed to deal with inter-patient variability. For each optimizing signal feature (continuous pressure, maximum pressure and tonus), individual (single patient), global (full database) and adaptive models were built to estimate the recorded IUP signal. The results were evaluated by computing the root mean square errors (RMSe): continuous pressure error (CPe), maximum pressure error (MPe) and tonus error (TOe). MAIN RESULTS:The continuous pressure global model yielded IUP estimates with Cpe = 14.61 mm Hg, MPe = 29.17 mm Hg and Toe = 7.8 mm Hg. The adaptive models significantly reduced errors to CPe = 11.88, MPe = 16.02 and Toe = 5.61 mm Hg. The EHG-based IUP estimates outperformed those from traditional tocographic recordings, which had significantly higher errors (CPe = 21.93, MPe = 26.97, and TOe = 13.96). SIGNIFICANCE:Our results show that adaptive models yield better IUP estimates than the traditional approaches and provide the best balance of the different errors computed for a better assessment of the labor progress and maternal and fetal well-being.
journal_name
Physiol Measjournal_title
Physiological measurementauthors
Benalcazar-Parra C,Garcia-Casado J,Ye-Lin Y,Alberola-Rubio J,Lopez Á,Perales-Marin A,Prats-Boluda Gdoi
10.1088/1361-6579/ab37dbsubject
Has Abstractpub_date
2019-09-03 00:00:00pages
085003issue
8eissn
0967-3334issn
1361-6579journal_volume
40pub_type
杂志文章abstract::In this study, the selection of coil configuration parameters (coil radius and coil centre shift) for induced current EIT using circular coils is investigated. An alternative coil configuration is suggested, which produces approximately linear (spatially) magnetic fields in order to strengthen the currents in the cent...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/007
更新日期:1994-05-01 00:00:00
abstract::The paper describes the development of an electrical impedance tomography (EIT) system for gynecologic research. The GIT (gynecological impedance tomography) system has 48 electrodes and is embedded on a small space (30 mm diameter and 20 mm height) inside of the vaginal probe. The system provides real-time (one shot ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/5/849
更新日期:2012-05-01 00:00:00
abstract::Alzheimer's disease (AD) is a degenerative disease which causes serious cognitive decline. Studies suggest that effective treatments for AD may be aided by the detection of the disease in its early stages, prior to extensive neuronal degeneration. In this paper, we propose a set of novel techniques which could help to...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/4/001
更新日期:2007-04-01 00:00:00
abstract::This paper describes a method of reducing the influence of the data error caused by non-ideal boundary shape and electrode placement on reconstructed images. A data calibration and a modified Newton-Raphson reconstruction are combined in the method to ensure rapid convergence and small reconstruction error. The method...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/15/2a/022
更新日期:1994-05-01 00:00:00
abstract::The activPAL™ activity monitor has potential for use in youth with Cerebral Palsy (CP) as it has demonstrated acceptable validity for the assessment of sedentary and physical activity in other populations. This study determined the validity of the activPAL™ activity monitor for the measurement of sitting, standing, wa...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/11/2307
更新日期:2014-11-01 00:00:00
abstract::The heart rate responds dynamically to various intrinsic and environmental stimuli. The autonomic nervous system is said to play a major role in this response. Multifractal analysis offers a novel method to assess the response of cardiac interbeat intervals. Twenty-four hour ECG recordings of RR interbeat intervals (o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/10/014
更新日期:2011-10-01 00:00:00
abstract::Temporal changes in the impedance spectra of bioelectrodes in contact with skin provide useful data for comparisons between differing electrode materials and skin preparation methods. Traditional impedance measuring systems employ swept frequency methods which will distort results in the impedance spectra of a sample ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/20/1/008
更新日期:1999-02-01 00:00:00
abstract:OBJECTIVE:Brain waves vary between people. This work aims to improve automatic sleep staging for longitudinal sleep monitoring via personalization of algorithms based on individual characteristics extracted from sleep data recorded during the first night. APPROACH:As data from a single night are very small, thereby ma...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab921e
更新日期:2020-07-01 00:00:00
abstract::The Timed Up and Go (TUG) test is a widely used measure of mobility and fall risk among older adults that is typically scored using a stopwatch. We tested the hypothesis that a body-fixed accelerometer can enhance the ability of the TUG to identify community-living older adults with a relatively high fall risk of unkn...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/12/009
更新日期:2011-12-01 00:00:00
abstract:OBJECTIVE:Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/aac9a9
更新日期:2018-06-27 00:00:00
abstract::Automatic sleep stage classification with cardiorespiratory signals has attracted increasing attention. In contrast to the traditional manual scoring based on polysomnography, these signals can be measured using advanced unobtrusive techniques that are currently available, promising the application for personal and co...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/10/2027
更新日期:2015-10-01 00:00:00
abstract::A new method to image and quantify intra-abdominal haemorrhage using electrical impedance tomography (EIT) was tested in vivo. Supine peritoneal dialysis patients were monitored using an 8-electrode hemiarray placed on the anterior abdomen. EIT measurements were recorded using the EPack II data acquisition system befo...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/2/001
更新日期:2011-02-01 00:00:00
abstract::The purpose of this study was to investigate the linearity and reliability of the mechanomyographic (MMG) amplitude versus submaximal isometric force relationship for the vastus lateralis. Twenty healthy subjects (mean +/- SD age = 24.0 +/- 4.3 years) volunteered to perform submaximal isometric muscle actions of the d...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/30/10/002
更新日期:2009-10-01 00:00:00
abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/34/6/659
更新日期:2013-06-01 00:00:00
abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/37/3/418
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/abc0b6
更新日期:2020-12-11 00:00:00
abstract::Although people spend a third of their day engaged in sedentary activities, research on heart activity during sitting is almost nonexistent because of the discomfort experienced when electrocardiogram (ECG) measurement electrodes are attached to the body. Accordingly, in this study, a system was developed to monitor h...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/N61
更新日期:2015-03-01 00:00:00
abstract::Non-invasive in vivo neutron activation analysis (NAA) was used to measure the fluorine concentration in 35 people in Hamilton, Ontario, Canada. Measurement and precision data of this second generation NAA system were determined in 2013, and the results were compared with the performance of a first generation system u...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/36/3/465
更新日期:2015-03-01 00:00:00
abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/33/9/1435
更新日期:2012-09-01 00:00:00
abstract::Non-invasive fetal heart rate is of great relevance in clinical practice to monitor fetal health state during pregnancy. To date, however, despite significant advances in the field of electrocardiography, the analysis of abdominal fetal ECG is considered a challenging problem for biomedical and signal processing commu...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/8/1607
更新日期:2014-08-01 00:00:00
abstract::Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F(-)) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almos...
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/33/2/243
更新日期:2012-02-01 00:00:00
abstract::We investigated the utility of ICA for evaluation of fetal rhythm in five uncomplicated twin pregnancies and in five twin pregnancies complicated by fetal arrhythmia. Using objective and subjective criteria, we sought to determine how the signal-to-noise ratio, signal fidelity and interference rejection are affected w...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/32/1/004
更新日期:2011-01-01 00:00:00
abstract::Despite significant advances in adult clinical electrocardiography (ECG) signal processing techniques and the power of digital processors, the analysis of non-invasive foetal ECG (NI-FECG) is still in its infancy. The Physionet/Computing in Cardiology Challenge 2013 addresses some of these limitations by making a set ...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/35/8/1569
更新日期:2014-08-01 00:00:00
abstract::Body surface potential maps recorded during catheter pace mapping can facilitate the localization of the site of origin of ventricular tachycardia. In this study, we investigated the value of a realistic computer model of the human ventricular myocardium in generating body surface potential maps as templates for ident...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/18/4/010
更新日期:1997-11-01 00:00:00
abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/31/4/N01
更新日期:2010-04-01 00:00:00
abstract::The electrocardiogram is a representative signal containing information about the condition of the heart. The shape and size of the P-QRS-T wave, the time intervals between its various peaks, etc may contain useful information about the nature of disease affecting the heart. However, the human observer cannot directly...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/25/5/005
更新日期:2004-10-01 00:00:00
abstract:OBJECTIVE:Advanced neuroimaging has proved to be pivotal in the management of acute ischemic stroke. The use of CT perfusion (CTP) core and penumbra parameters to predict the outcome in wake-up stroke (WUS) patients in everyday clinical scenarios has not yet been investigated. The aim of our study was to investigate th...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/1361-6579/ab9c70
更新日期:2020-08-11 00:00:00
abstract::Electrical impedance tomography (EIT) image reconstruction is an ill-posed problem requiring maximum measurement precision. Recent EIT systems claim 60 to 80 dB precision. Achieving higher values is hard in practice since measurements must be performed at relatively high frequency, on a living subject, while using com...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/27/5/S05
更新日期:2006-05-01 00:00:00
abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....
journal_title:Physiological measurement
pub_type: 临床试验,杂志文章
doi:10.1088/0967-3334/25/5/015
更新日期:2004-10-01 00:00:00
abstract::In order to detect minute amounts of glucose in diluted urine, we applied the Raman spectroscopy method. To simulate abnormal diluted urine in a toilet bowl, we diluted normal urine ten-fold with water and added glucose up to 8 mg dl(-1). Data were collected using a low-resolution Raman spectrometer that was preproces...
journal_title:Physiological measurement
pub_type: 杂志文章
doi:10.1088/0967-3334/28/5/011
更新日期:2007-05-01 00:00:00