Lab-based validation of different data processing methods for wrist-worn ActiGraph accelerometers in young adults.

Abstract:

:The wrist is increasingly being used as the preferred site for objectively assessing physical activity but the relative accuracy of processing methods for wrist data has not been determined. OBJECTIVE:This study evaluates the validity of four processing methods for wrist-worn ActiGraph (AG) data against energy expenditure (EE) measured using a portable metabolic analyzer (OM; Oxycon mobile) and the Compendium of physical activity. APPROACH:Fifty-one adults (ages 18-40) completed 15 activities ranging from sedentary to vigorous in a laboratory setting while wearing an AG and the OM. Estimates of EE and categorization of activity intensity were obtained from the AG using a linear method based on Hildebrand cutpoints (HLM), a non-linear modification of this method (HNLM), and two methods developed by Staudenmayer based on a Linear Model (SLM) and using random forest (SRF). Estimated EE and classification accuracy were compared to the OM and Compendium using Bland-Altman plots, equivalence testing, mean absolute percent error (MAPE), and Kappa statistics. MAIN RESULTS:Overall, classification agreement with the Compendium was similar across methods ranging from a Kappa of 0.46 (HLM) to 0.54 (HNLM). However, specificity and sensitivity varied by method and intensity, ranging from a sensitivity of 0% (HLM for sedentary) to a specificity of ~99% for all methods for vigorous. None of the methods was significantly equivalent to the OM (p  >  0.05). SIGNIFICANCE:Across activities, none of the methods evaluated had a high level of agreement with criterion measures. Additional research is needed to further refine the accuracy of processing wrist-worn accelerometer data.

journal_name

Physiol Meas

authors

Ellingson LD,Hibbing PR,Kim Y,Frey-Law LA,Saint-Maurice PF,Welk GJ

doi

10.1088/1361-6579/aa6d00

subject

Has Abstract

pub_date

2017-06-01 00:00:00

pages

1045-1060

issue

6

eissn

0967-3334

issn

1361-6579

journal_volume

38

pub_type

杂志文章
  • Comparison of macro- and micro-lightguide spectrophotometric measurements of microvascular haemoglobin oxygenation in the tuberculin reaction in normal human skin.

    abstract::The changes in haemoglobin oxygenation (SO2) occurring in the tuberculin reaction in human skin were measured using macro- and micro-lightguide spectrophotometry and the results compared. A significant difference was found between the measurements from the respective instruments, demonstrating that the micro-lightguid...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/2/002

    authors: Newton DJ,Harrison DK,Delaney CJ,Beck JS,McCollum PT

    更新日期:1994-05-01 00:00:00

  • Invasive and noninvasive means of measuring intracranial pressure: a review.

    abstract::Measurement of intracranial pressure (ICP) can be invaluable in the management of critically ill patients. Cerebrospinal fluid is produced by the choroid plexus in the brain ventricles (a set of communicating chambers), after which it circulates through the different ventricles and exits into the subarachnoid space ar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa7256

    authors: Zhang X,Medow JE,Iskandar BJ,Wang F,Shokoueinejad M,Koueik J,Webster JG

    更新日期:2017-07-24 00:00:00

  • An efficient unsupervised fetal QRS complex detection from abdominal maternal ECG.

    abstract::Non-invasive fetal heart rate is of great relevance in clinical practice to monitor fetal health state during pregnancy. To date, however, despite significant advances in the field of electrocardiography, the analysis of abdominal fetal ECG is considered a challenging problem for biomedical and signal processing commu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1607

    authors: Varanini M,Tartarisco G,Billeci L,Macerata A,Pioggia G,Balocchi R

    更新日期:2014-08-01 00:00:00

  • Pilot acute study of feedback-controlled retrograde peristalsis invoked by neural gastric electrical stimulation.

    abstract::Neural gastric electrical stimulation (NGES) is a new method for invoking gastric contractions under microprocessor control. However, optimization of this technique using feedback mechanisms to minimize power consumption and maximize effectiveness has been lacking. The present pilot study proposes a prototype feedback...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/3/006

    authors: Aelen P,Jurkov A,Aulanier A,Mintchev MP

    更新日期:2009-03-01 00:00:00

  • The linearity and reliability of the mechanomyographic amplitude versus submaximal isometric force relationship.

    abstract::The purpose of this study was to investigate the linearity and reliability of the mechanomyographic (MMG) amplitude versus submaximal isometric force relationship for the vastus lateralis. Twenty healthy subjects (mean +/- SD age = 24.0 +/- 4.3 years) volunteered to perform submaximal isometric muscle actions of the d...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/10/002

    authors: Beck TW,DeFreitas JM,Stock MS

    更新日期:2009-10-01 00:00:00

  • PET(CO2) measurement and feature extraction of capnogram signals for extubation outcomes from mechanical ventilation.

    abstract::Capnography is a continuous and noninvasive method for carbon dioxide (CO2) measurement, and it has become the standard of care for basic respiratory monitoring for intubated patients in the intensive care unit. In addition, it has been used to adjust ventilatory parameters during mechanical ventilation (MV). However,...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/2/231

    authors: Rasera CC,Gewehr PM,Domingues AM

    更新日期:2015-02-01 00:00:00

  • Chasing the evidence: the influence of data segmentation on estimates of dynamic cerebral autoregulation.

    abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7ddf

    authors: Panerai RB,Intharakham K,Haunton V,Minhas JS,Llwyd O,Lam M,Salinet ASM,Nogueira RC,Katsogridakis E,Maggio P,Robinson TG

    更新日期:2020-04-17 00:00:00

  • Time-varying analysis of heart rate variability signals with a Kalman smoother algorithm.

    abstract::A time-varying parametric spectrum estimation method for analysing non-stationary heart rate variability signals is presented. As a case study, the dynamics of heart rate variability during an orthostatic test is examined. In this method, the non-stationary signal is first modelled with a time-varying autoregressive m...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/27/3/002

    authors: Tarvainen MP,Georgiadis SD,Ranta-Aho PO,Karjalainen PA

    更新日期:2006-03-01 00:00:00

  • Measuring dissimilarity between respiratory effort signals based on uniform scaling for sleep staging.

    abstract::Polysomnography (PSG) has been extensively studied for sleep staging, where sleep stages are usually classified as wake, rapid-eye-movement (REM) sleep, or non-REM (NREM) sleep (including light and deep sleep). Respiratory information has been proven to correlate with autonomic nervous activity that is related to slee...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/12/2529

    authors: Long X,Yang J,Weysen T,Haakma R,Foussier J,Fonseca P,Aarts RM

    更新日期:2014-12-01 00:00:00

  • Adipose tissue thickness does not affect the electromechanical delay.

    abstract::During voluntary contractions in humans, the subcutaneous tissues between surface electrodes and active motor units have been shown to attenuate surface electromyographic (EMG) signal amplitude. The purpose of this investigation was to examine the relationship between adipose tissue thickness and the electromechnical ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/37/3/418

    authors: Stock MS,Thompson BJ

    更新日期:2016-03-01 00:00:00

  • The effect of serial data collection on the accuracy of electrical impedance tomography images.

    abstract::There has been a surge of interest in using electrical impedance tomography (EIT) for monitoring regional lung ventilation, however, EIT is an ill-conditioned problem, and errors/noise in the boundary voltages can have an undesirable effect on the quality of the final image. Most EIT systems in clinical usage use seri...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/34/6/659

    authors: Yerworth R,Bayford R

    更新日期:2013-06-01 00:00:00

  • A practical approach to storage and retrieval of high-frequency physiological signals.

    abstract:OBJECTIVE:Storage of physiological waveform data for retrospective analysis presents significant challenges. Resultant data can be very large, and therefore becomes expensive to store and complicated to manage. Traditional database approaches are not appropriate for large scale storage of physiological waveforms. Our g...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7cb5

    authors: Goodwin AJ,Eytan D,Greer RW,Mazwi M,Thommandram A,Goodfellow SD,Assadi A,Jegatheeswaran A,Laussen PC

    更新日期:2020-04-20 00:00:00

  • Neural network analysis of oxygenation signals in infants during sleep.

    abstract::The use of artificial neural networks (ANNs) to interpret sleep monitoring signals is described. Recordings from ten infants with apparent life threatening episodes were assigned into training feedforward R-PROP networks. In order to separate good signal from artefact, 60 second time frames of SaO2 and TcPO2 signals w...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/21/3/401

    authors: Taktak AF,Simpson S,Patel S,Meyer G

    更新日期:2000-08-01 00:00:00

  • Endocardial center motion for quantification of left ventricular discoordination in heart failure using cine MRI.

    abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaaa0

    authors: Saporito S,Houthuizen P,Aben JMM,Westenberg JJM,van Den Bosch HCM,van Assen HC,Mischi M

    更新日期:2018-02-28 00:00:00

  • Carotid flow rates and flow division at the bifurcation in healthy volunteers.

    abstract::In nine healthy subjects, magnetic resonance imaging was used to measure blood flow waveforms in the common (CCA), internal (ICA) and external (ECA) carotid arteries. Useful data were acquired from 14 carotid arteries in total. Flow rates were determined from regions of interest placed over the arteries in CINE-phase ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/3/009

    authors: Marshall I,Papathanasopoulou P,Wartolowska K

    更新日期:2004-06-01 00:00:00

  • Video rate electrical impedance tomography of vascular changes: preclinical development.

    abstract::Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/3/006

    authors: Halter R,Hartov A,Paulsen K

    更新日期:2008-03-01 00:00:00

  • Non-contact video-based vital sign monitoring using ambient light and auto-regressive models.

    abstract::Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/5/807

    authors: Tarassenko L,Villarroel M,Guazzi A,Jorge J,Clifton DA,Pugh C

    更新日期:2014-05-01 00:00:00

  • Video-based respiration monitoring with automatic region of interest detection.

    abstract::Vital signs monitoring is ubiquitous in clinical environments and emerging in home-based healthcare applications. Still, since current monitoring methods require uncomfortable sensors, respiration rate remains the least measured vital sign. In this paper, we propose a video-based respiration monitoring method that aut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/100

    authors: Janssen R,Wang W,Moço A,de Haan G

    更新日期:2016-01-01 00:00:00

  • Assessing the validity and reliability and determining cut-points of the Actiwatch 2 in measuring physical activity.

    abstract:OBJECTIVE:The Actiwatch 2 (AW2) is a wrist-worn accelerometer typically used to measure sleep. Although it can measure physical activity, there is limited evidence supporting its validity. We assessed the validity and reliability of the AW2 to measure sedentary behavior and physical activity (light, moderate, vigorous ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba80f

    authors: Kemp C,Pienaar PR,Henst RHP,Roden LC,Kolbe-Alexander TL,Rae DE

    更新日期:2020-09-04 00:00:00

  • Compressive sensing in electrical impedance tomography for breathing monitoring.

    abstract:OBJECTIVE:Electrical impedance tomography (EIT) is a functional imaging technique in which cross-sectional images of structures are reconstructed based on boundary trans-impedance measurements. Continuous functional thorax monitoring using EIT has been extensively researched. Increasing the number of electrodes, number...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab0daa

    authors: Shiraz A,Khodadad D,Nordebo S,Yerworth R,Frerichs I,van Kaam A,Kallio M,Papadouri T,Bayford R,Demosthenous A

    更新日期:2019-04-03 00:00:00

  • Automatic sleep-stage scoring based on photoplethysmographic signals.

    abstract:OBJECTIVE:Sleep-stage scoring is important for sleep-quality evaluation and the diagnosis of related diseases. In this study, an automatic sleep-stage scoring method using photoplethysmographic (PPG) signals was proposed. APPROACH:To construct the classification model, we extracted 14 time-domain features, 17 frequenc...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab921d

    authors: Wu X,Yang J,Pan Y,Zhang X,Luo Y

    更新日期:2020-06-30 00:00:00

  • Different approaches for quantifying ventilation distribution and lung tissue properties by functional EIT.

    abstract::We investigated five different methods which can be applied to quantitatively construct functional tomograms of the lungs. The focus was on the sensitivity of functional tomograms to errors in acquired data. To quantify this sensitivity, theoretical, error-free data sets of well-known properties were artificially gene...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/8/S06

    authors: Hahn G,Dittmar J,Just A,Quintel M,Hellige G

    更新日期:2010-08-01 00:00:00

  • Detection of acute periodontal pain from physiological signals.

    abstract:OBJECTIVE:To investigate the feasibility of the detection of brief orofacial pain sensations from easily recordable physiological signals by means of machine learning techniques. APPROACH:A total of 47 subjects underwent periodontal probing and indicated each instance of pain perception by means of a push button. Simu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aadf0c

    authors: Teichmann D,Klopp J,Hallmann A,Schuett K,Wolfart S,Teichmann M

    更新日期:2018-09-27 00:00:00

  • Preliminary static EIT images of the thorax in health and disease.

    abstract::The results of a preliminary clinical evaluation of a one-frequency electrical impedance tomography (EIT) system enabling static in vivo imaging are presented. The design of the measuring system and image reconstruction software are described. Thirty-one subjects were examined and divided into four clinical groups. Th...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/23/1/304

    authors: Cherepenin V,Karpov A,Korjenevsky A,Kornienko V,Kultiasov Y,Mazaletskaya A,Mazourov D

    更新日期:2002-02-01 00:00:00

  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • An electrical impedance tomography system for gynecological application GIT with a tiny electrode array.

    abstract::The paper describes the development of an electrical impedance tomography (EIT) system for gynecologic research. The GIT (gynecological impedance tomography) system has 48 electrodes and is embedded on a small space (30 mm diameter and 20 mm height) inside of the vaginal probe. The system provides real-time (one shot ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/5/849

    authors: V A C,Y V G,A V K,S A S,T S T

    更新日期:2012-05-01 00:00:00

  • The contribution of vascular smooth muscle, elastin and collagen on the passive mechanics of porcine carotid arteries.

    abstract::The main components responsible for the mechanical behavior of the arterial wall are collagen, elastin, and smooth muscle cells (SMCs) in the medial layer. We determined the structural and mechanical changes in porcine carotid arteries after administration of Triton® X-100, elastase, and collagenase using the inflatio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/8/1335

    authors: Kochová P,Kuncová J,Svíglerová J,Cimrman R,Miklíková M,Liška V,Tonar Z

    更新日期:2012-08-01 00:00:00

  • Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

    abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/367

    authors: Lee BI,Oh SH,Woo EJ,Lee SY,Cho MH,Kwon O,Seo JK,Baek WS

    更新日期:2003-05-01 00:00:00

  • Cardio-respiratory signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning.

    abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab525c

    authors: Chaichulee S,Villarroel M,Jorge J,Arteta C,McCormick K,Zisserman A,Tarassenko L

    更新日期:2019-12-02 00:00:00

  • Validation of a finite-element solution for electrical impedance tomography in an anisotropic medium.

    abstract::Electrical impedance tomography is an imaging method, with which volumetric images of conductivity are produced by injecting electrical current and measuring boundary voltages. It has the potential to become a portable non-invasive medical imaging technique. Until now, implementations have neglected anisotropy even th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/7/S10

    authors: Abascal JF,Arridge SR,Lionheart WR,Bayford RH,Holder DS

    更新日期:2007-07-01 00:00:00