Assessment of non-invasive time and frequency atrial fibrillation organization markers with unipolar atrial electrograms.

Abstract:

:The standard electrocardiogram (ECG) is the most common non-invasive way to study atrial fibrillation (AF). In this respect, previous works have shown that the surface lead V(1) reflects mainly the dominant atrial frequency (DAF) of the right atrium (RA), which has been widely used to study AF. In a similar way, AF organization and fibrillatory (f) wave amplitude are two recently proposed non-invasive AF markers. These markers need to be validated with invasive recordings in order to assess their capability to reliably reflect the internal fibrillatory activity dynamics. In this work, these two non-invasive metrics have been compared with similar measures recorded from two unipolar atrial electrograms (AEGs). For both ECG and AEG signals, AF organization has been computed by applying a nonlinear regularity index, such as sample entropy (SampEn), to the atrial activity (AA) and to its fundamental waveform, defined as the main atrial wave (MAW). The surface and epicardial f wave amplitude has been estimated through their mean power. Results obtained for 38 patients showed statistically significant correlations between the values measured from surface and invasive recordings, thus corroborating the usefulness of the aforesaid markers in the non-invasive study of AF. Precisely, for AF organization computed from the MAW, the correlation coefficients between surface and both AEGs were R = 0.926 (p < 0.001) and R = 0.932 (p < 0.001). For f wave amplitude, slightly lower significant relationships were noticed, the correlation coefficients being R = 0.765 (p < 0.001) and R = 0.842 (p < 0.001). These outcomes together with interesting linear relationships found among the parameters suggest that AF regularity estimated via SampEn and f wave amplitude can non-invasively characterize the epicardial activity related to AF.

journal_name

Physiol Meas

authors

Alcaraz R,Hornero F,Rieta JJ

doi

10.1088/0967-3334/32/1/007

subject

Has Abstract

pub_date

2011-01-01 00:00:00

pages

99-114

issue

1

eissn

0967-3334

issn

1361-6579

pii

S0967-3334(11)64160-3

journal_volume

32

pub_type

杂志文章
  • A pH-mucosa area unit of measure to consider morphology of the oesophagus when evaluating oesophagitis.

    abstract::Gastro-oesophageal pH measurements are routinely carried out to quantify and determine if levels of acid reflux are responsible for symptoms. Although considered the 'gold standard', evidence suggests that pH measurements do not correlate well with the degree of oesophagitis seen during endoscopy. In this study the cu...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/4/006

    authors: Haylett KR,Vales P,Lee SH,McCloy RF

    更新日期:2003-11-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Tracking boundary movement and exterior shape modelling in lung EIT imaging.

    abstract::Electrical impedance tomography (EIT) has shown significant promise for lung imaging. One key challenge for EIT in this application is the movement of electrodes during breathing, which introduces artefacts in reconstructed images. Various approaches have been proposed to compensate for electrode movement, but no comp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/6/1119

    authors: Biguri A,Grychtol B,Adler A,Soleimani M

    更新日期:2015-06-01 00:00:00

  • Solving the forward problem in electrical impedance tomography for the human head using IDEAS (integrated design engineering analysis software), a finite element modelling tool.

    abstract::If electrical impedance tomography is to be used as a clinical tool, the image reconstruction algorithms must yield accurate images of impedance changes. One of the keys to producing an accurate reconstructed image is the inclusion of prior information regarding the physical geometry of the object. To achieve this, ma...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/1/308

    authors: Bayford RH,Gibson A,Tizzard A,Tidswell T,Holder DS

    更新日期:2001-02-01 00:00:00

  • Life-threatening false alarm rejection in ICU: using the rule-based and multi-channel information fusion method.

    abstract::False alarm (FA) rates as high as 86% have been reported in intensive care unit monitors. High FA rates decrease quality of care by slowing staff response times while increasing patient burdens and stresses. In this study, we proposed a rule-based and multi-channel information fusion method for accurately classifying ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/8/1298

    authors: Liu C,Zhao L,Tang H,Li Q,Wei S,Li J

    更新日期:2016-08-01 00:00:00

  • Adaptive techniques in electrical impedance tomography reconstruction.

    abstract::We present an adaptive algorithm for solving the inverse problem in electrical impedance tomography. To strike a balance between the accuracy of the reconstructed images and the computational efficiency of the forward and inverse solvers, we propose to combine an adaptive mesh refinement technique with the adaptive Ka...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1111

    authors: Li T,Isaacson D,Newell JC,Saulnier GJ

    更新日期:2014-06-01 00:00:00

  • Energy scavenging sources for biomedical sensors.

    abstract::Energy scavenging has increasingly become an interesting option for powering electronic devices because of the almost infinite lifetime and the non-dependence on fuels for energy generation. Moreover, the rise of wireless technologies promises new applications in medical monitoring systems, but these still face limita...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/0967-3334/30/9/R01

    authors: Romero E,Warrington RO,Neuman MR

    更新日期:2009-09-01 00:00:00

  • Early prediction of unexplained syncope by support vector machines.

    abstract::The goal of the present study was to develop and evaluate a new method for the prediction of unexplained syncope occurrences. Diagnosis of syncope is currently based on the reproduction of symptoms in combination with hypotension and bradycardia induced by a 45 min 60-70 degrees head-upright tilt test (HUTT). The main...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/28/2/007

    authors: Schang D,Feuilloy M,Plantier G,Fortrat JO,Nicolas P

    更新日期:2007-02-01 00:00:00

  • Predicting clinical ischaemia during awake carotid endarterectomy: use of the SJVO2 probe as a guide to selective shunting.

    abstract::Stroke is a major cause of disability within the western world. About 20% of strokes are a consequence of atheromatous narrowing of the origin of the internal carotid artery. Carotid endarterectomy has been shown to be an effective treatment for those with symptomatic and severe stenosis, provided the risk of death an...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/2/310

    authors: Crossman J,Banister K,Bythell V,Bullock R,Chambers I,Mendelow AD

    更新日期:2003-05-01 00:00:00

  • A comparison of technologies used for estimation of body temperature.

    abstract::Body temperature measurement is an important clinical parameter. The performance of a number of non-invasive thermometers was measured by comparing intra- and inter-operator variability (n = 100) and clinical accuracy (n = 61). Variability was elevated in febrile compared to normothermic subjects for axillary and oral...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/003

    authors: Mangat J,Standley T,Prevost A,Vasconcelos J,White P

    更新日期:2010-09-01 00:00:00

  • A planar elliptical model of cardio-vagal hysteresis.

    abstract::The state-dependent portion of cardio-vagal baroreflex control is called baroreflex hyteresis: we observe hysteresis when RR interval and carotid diameter depend on both the direction and value of arterial pressure. The elasticity of arterial walls, as well as the responsiveness of central command reset controls the r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/6/009

    authors: Ler AS,Cohen MA,Taylor JA

    更新日期:2010-06-01 00:00:00

  • Monitoring fetal maturation-objectives, techniques and indices of autonomic function.

    abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/aa5fca

    authors: Hoyer D,Żebrowski J,Cysarz D,Gonçalves H,Pytlik A,Amorim-Costa C,Bernardes J,Ayres-de-Campos D,Witte OW,Schleußner E,Stroux L,Redman C,Georgieva A,Payne S,Clifford G,Signorini MG,Magenes G,Andreotti F,Malberg H,Zaun

    更新日期:2017-05-01 00:00:00

  • Endocardial center motion for quantification of left ventricular discoordination in heart failure using cine MRI.

    abstract:OBJECTIVE:To compare a novel cardiovascular magnetic resonance technique for the assessment of left ventricular (LV) mechanical discoordination by characterizing the endocardial center motion (ECM) in short-axis cine MRI in healthy volunteers and heart failure patients with left bundle branch block (HF-LBBB). APPROACH...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaaaa0

    authors: Saporito S,Houthuizen P,Aben JMM,Westenberg JJM,van Den Bosch HCM,van Assen HC,Mischi M

    更新日期:2018-02-28 00:00:00

  • Fetal motion estimation from noninvasive cardiac signal recordings.

    abstract::Fetal motility is a widely accepted indicator of the well-being of a fetus. In previous research, it has be shown that fetal motion (FM) is coherent with fetal heart rate accelerations and an indicator for active/rest cycles of the fetus. The most common approach for FM and fetal heart rate (FHR) assessment is by Dopp...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/11/2003

    authors: Biglari H,Sameni R

    更新日期:2016-11-01 00:00:00

  • The effect of fracture and fracture fixation on ultrasonic velocity and attenuation.

    abstract::Measurement of the velocity of propagation and attenuation of ultrasound (200 kHz) is believed to be a useful non-invasive technique for assessing the mechanical properties of bone. A new method for the determination of ultrasound velocity and attenuation of longitudinal waves in cortical bone was used in vivo and in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/17/3/006

    authors: Saulgozis J,Pontaga I,Lowet G,Van der Perre G

    更新日期:1996-08-01 00:00:00

  • Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedances.

    abstract::Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/9/007

    authors: Ward LC,Essex T,Cornish BH

    更新日期:2006-09-01 00:00:00

  • Assessment of hepatic fatty infiltration using dual-energy computed tomography: a phantom study.

    abstract::The purpose of this study was to examine the performance of dual-energy computed tomography (DECT) for the quantification of liver fat content (LFC). We prepared two phantoms: homogenized mixtures of porcine liver and fat and homogeneous mixtures of liver- and fat-equivalent solutions. Tubes containing mixtures with k...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/4/597

    authors: Li JH,Tsai CY,Huang HM

    更新日期:2014-04-01 00:00:00

  • Assessing the validity and reliability and determining cut-points of the Actiwatch 2 in measuring physical activity.

    abstract:OBJECTIVE:The Actiwatch 2 (AW2) is a wrist-worn accelerometer typically used to measure sleep. Although it can measure physical activity, there is limited evidence supporting its validity. We assessed the validity and reliability of the AW2 to measure sedentary behavior and physical activity (light, moderate, vigorous ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba80f

    authors: Kemp C,Pienaar PR,Henst RHP,Roden LC,Kolbe-Alexander TL,Rae DE

    更新日期:2020-09-04 00:00:00

  • A portable device with low-power consumption for monitoring mouse vital signs during in vivo photoacoustic imaging and photothermal therapy.

    abstract:OBJECTIVE:The aim of this study was to monitor the physiological changes and cytotoxic effects of exogenous contrast agents during photoacoustic imaging (PAI) and photothermal therapy (PTT). In this paper, a low-power telemetric device for mouse vital signs monitoring was designed and demonstrated. APPROACH:The power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aba6a1

    authors: Phan DT,Phan TTV,Bui NT,Park S,Choi J,Oh J

    更新日期:2021-01-01 00:00:00

  • A method for modelling and optimizing an electrical impedance tomography system.

    abstract::Electrical impedance tomography (EIT) image reconstruction is an ill-posed problem requiring maximum measurement precision. Recent EIT systems claim 60 to 80 dB precision. Achieving higher values is hard in practice since measurements must be performed at relatively high frequency, on a living subject, while using com...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/5/S05

    authors: Hartinger AE,Gagnon H,Guardo R

    更新日期:2006-05-01 00:00:00

  • Multichannel simultaneous magnetic induction measurement system (MUSIMITOS).

    abstract::Non-contact heart and lung activity monitoring would be a desirable supplement to conventional monitoring techniques. Based on the potential of non-contact magnetic induction measurements, requirements for an adequate monitoring system were estimated. This formed the basis for the development of the presented extendab...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/6/S25

    authors: Steffen M,Heimann K,Bernstein N,Leonhardt S

    更新日期:2008-06-01 00:00:00

  • Validation of a new dielectric device to assess changes of tissue water in skin and subcutaneous fat.

    abstract::Easily applicable and inexpensive water-specific techniques to evaluate local oedema, swollen tissue problems and fluid retention in humans are not available. In the present investigation a recently constructed non-invasive device for a local measurement of changes in tissue water in human skin and subcutaneous fat (S...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/2/004

    authors: Nuutinen J,Ikäheimo R,Lahtinen T

    更新日期:2004-04-01 00:00:00

  • Personalized automatic sleep staging with single-night data: a pilot study with Kullback-Leibler divergence regularization.

    abstract:OBJECTIVE:Brain waves vary between people. This work aims to improve automatic sleep staging for longitudinal sleep monitoring via personalization of algorithms based on individual characteristics extracted from sleep data recorded during the first night. APPROACH:As data from a single night are very small, thereby ma...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab921e

    authors: Phan H,Mikkelsen K,Chén OY,Koch P,Mertins A,Kidmose P,De Vos M

    更新日期:2020-07-01 00:00:00

  • Cardio-respiratory signal extraction from video camera data for continuous non-contact vital sign monitoring using deep learning.

    abstract::Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-co...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab525c

    authors: Chaichulee S,Villarroel M,Jorge J,Arteta C,McCormick K,Zisserman A,Tarassenko L

    更新日期:2019-12-02 00:00:00

  • Chronodiagnostic acquisition of recovery speed of heart rate under bathing stress.

    abstract::Cycling on an ergometer is one effective means of measuring cardiovascular function while applying stress on the heart. Bathing in a hot water bath applies a low stress to the heart. The electrocardiograms of a healthy adult male (aged 35 at the start of study) were recorded while taking a hot water bath with no elect...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/20/4/304

    authors: Ishijima M,Togawa T

    更新日期:1999-11-01 00:00:00

  • Improved ultrasound transducer positioning by fetal heart location estimation during Doppler based heart rate measurements.

    abstract:OBJECTIVE:Doppler ultrasound (US) is the most commonly applied method to measure the fetal heart rate (fHR). When the fetal heart is not properly located within the ultrasonic beam, fHR measurements often fail. As a consequence, clinical staff need to reposition the US transducer on the maternal abdomen, which can be a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa8a1a

    authors: Hamelmann P,Vullings R,Schmitt L,Kolen AF,Mischi M,van Laar JOEH,Bergmans JWM

    更新日期:2017-09-21 00:00:00

  • Characterization of cardiorespiratory phase synchronization and directionality in late premature and full term infants.

    abstract:OBJECTIVE:Though the mutual influence of cardiovascular and respiratory rhythms in healthy newborns has been documented, its full characterization is still pending. In general, the activity of many physiological subsystems has a well-expressed rhythmic character, and often an interdependency between physiological rhyth...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac553

    authors: Lucchini M,Pini N,Fifer WP,Burtchen N,Signorini MG

    更新日期:2018-06-19 00:00:00

  • A randomized controlled trial studying the effect of maternal hyperoxygenation on fetal heart rate in suspected fetal distress.

    abstract:OBJECTIVE:To investigate the effect of maternal hyperoxygenation on fetal heart rate (FHR) when applied for suspected fetal distress during the second stage of term labor. APPROACH:A single-center randomized controlled trial was conducted in a tertiary care hospital in The Netherlands. Participants were included durin...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/abc0b6

    authors: Moors S,Joshi R,Bullens LM,van Oostrum NHM,Regis M,van den Heuvel ER,Oei SG,van Laar JOEH,van der Hout-van der Jagt MB

    更新日期:2020-12-11 00:00:00

  • Reference values for whole body and cerebral multi-frequency bio-impedance data in neonates less than 12 h postpartum.

    abstract::Multiple frequency bio-electrical impedance analysis (MFBIA) may be useful for monitoring fluid balance in newborn infants or to provide early prediction of the outcome following perinatal asphyxia. A reference range of data is needed for identification of babies with abnormal impedance values. This was a cross-sectio...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/11/010

    authors: Healy GN,Lingwood BE

    更新日期:2006-11-01 00:00:00

  • A practical approach to storage and retrieval of high-frequency physiological signals.

    abstract:OBJECTIVE:Storage of physiological waveform data for retrospective analysis presents significant challenges. Resultant data can be very large, and therefore becomes expensive to store and complicated to manage. Traditional database approaches are not appropriate for large scale storage of physiological waveforms. Our g...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7cb5

    authors: Goodwin AJ,Eytan D,Greer RW,Mazwi M,Thommandram A,Goodfellow SD,Assadi A,Jegatheeswaran A,Laussen PC

    更新日期:2020-04-20 00:00:00