Adaptive techniques in electrical impedance tomography reconstruction.

Abstract:

:We present an adaptive algorithm for solving the inverse problem in electrical impedance tomography. To strike a balance between the accuracy of the reconstructed images and the computational efficiency of the forward and inverse solvers, we propose to combine an adaptive mesh refinement technique with the adaptive Kaczmarz method. The iterative algorithm adaptively generates the optimal current patterns and a locally-refined mesh given the conductivity estimate and solves for the unknown conductivity distribution with the block Kaczmarz update step. Simulation and experimental results with numerical analysis demonstrate the accuracy and the efficiency of the proposed algorithm.

journal_name

Physiol Meas

authors

Li T,Isaacson D,Newell JC,Saulnier GJ

doi

10.1088/0967-3334/35/6/1111

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

1111-24

issue

6

eissn

0967-3334

issn

1361-6579

journal_volume

35

pub_type

杂志文章
  • Empirical mode decomposition analysis of HRV data from patients undergoing local anaesthesia (brachial plexus block).

    abstract::Spectral analysis of heart rate variability (HRV) is used for the assessment of cardiovascular autonomic control. In this study, a data-driven adaptive technique called empirical mode decomposition (EMD) and the associated Hilbert spectrum has been used to evaluate the effect of local anaesthesia on HRV parameters in ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/32/4/008

    authors: Shafqat K,Pal SK,Kumari S,Kyriacou PA

    更新日期:2011-04-01 00:00:00

  • Limited agreement between two noninvasive measurements of blood volume during fluid removal: ultrasound of inferior vena cava and finger-clip spectrophotometry of hemoglobin concentration.

    abstract:OBJECTIVE:Plots of blood volume measurements over time (profiles) may identify euvolemia during fluid removal for acute heart failure. We assessed agreement between two noninvasive measurements of blood volume profiles during mechanical fluid removal, which exemplifies the interstitial fluid shifts that occur during di...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab21af

    authors: Lucas BP,D'Addio A,Block C,Manning H,Remillard B,Leiter JC

    更新日期:2019-07-01 00:00:00

  • Continuous estimates of dynamic cerebral autoregulation: influence of non-invasive arterial blood pressure measurements.

    abstract::Temporal variability of parameters which describe dynamic cerebral autoregulation (CA), usually quantified by the short-term relationship between arterial blood pressure (BP) and cerebral blood flow velocity (CBFV), could result from continuous adjustments in physiological regulatory mechanisms or could be the result ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/4/006

    authors: Panerai RB,Sammons EL,Smith SM,Rathbone WE,Bentley S,Potter JF,Samani NJ

    更新日期:2008-04-01 00:00:00

  • Characteristic impedance: frequency or time domain approach?

    abstract:OBJECTIVE:Characteristic impedance (Zc) is an important component in the theory of hemodynamics. It is a commonly used metric of proximal arterial stiffness and pulse wave velocity. Calculated using simultaneously measured dynamic pressure and flow data, estimates of characteristic impedance can be obtained using metho...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aa9d60

    authors: Qureshi MU,Colebank MJ,Schreier DA,Tabima DM,Haider MA,Chesler NC,Olufsen MS

    更新日期:2018-01-31 00:00:00

  • Transthoracic impedance study with large self-adhesive electrodes in two conventional positions for defibrillation.

    abstract::External defibrillation requires the application of high voltage electrical impulses via large external electrodes, placed on selected locations on the thorax surface. The position of the electrodes is one of the major determinants of the transthoracic impedance (TTI) which influences the intracardiac current flow dur...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/10/007

    authors: Krasteva V,Matveev M,Mudrov N,Prokopova R

    更新日期:2006-10-01 00:00:00

  • A measurement of pulmonary blood volume increase during systole in humans.

    abstract::Pulmonary blood volume increase during systole was measured in patients by analysing chest images obtained during ECG gated radionuclide angiography examination. The difference in the total radiation counts between systole and diastole in regions of interest, which included the lungs and the left ventricle, was measur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/15/4/010

    authors: Nitzan M,Mahler Y,Schechter D,Yaffe S,Bocher M,Chisin R

    更新日期:1994-11-01 00:00:00

  • In vivo bioimpedance changes during haemorrhagic and ischaemic stroke in rats: towards 3D stroke imaging using electrical impedance tomography.

    abstract::Electrical impedance tomography (EIT) could be used as a portable non-invasive means to image the development of ischaemic stroke or haemorrhage. The purpose of this study was to examine if this was possible using time difference imaging, in the anesthetised rat using 40 spring-loaded scalp electrodes with applied con...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/6/765

    authors: Dowrick T,Blochet C,Holder D

    更新日期:2016-06-01 00:00:00

  • Dynamics of tissue shrinkage during ablative temperature exposures.

    abstract::There is a lack of studies that examine the dynamics of heat-induced shrinkage of organ tissues. Clinical procedures such as radiofrequency ablation, microwave ablation or high-intensity focused ultrasound, use heat to treat diseases such as cancer and cardiac arrhythmia. When heat is applied to tissues, shrinkage occ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/1/55

    authors: Rossmann C,Garrett-Mayer E,Rattay F,Haemmerich D

    更新日期:2014-01-01 00:00:00

  • Measuring gait with an accelerometer-based wearable: influence of device location, testing protocol and age.

    abstract::Wearables such as accelerometers are emerging as powerful tools for quantifying gait in various environments. Flexibility in wearable location may improve ease of use and data acquisition during instrumented testing. However, change of location may impact algorithm functionality when evaluating associated gait charact...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1785

    authors: Del Din S,Hickey A,Hurwitz N,Mathers JC,Rochester L,Godfrey A

    更新日期:2016-10-01 00:00:00

  • Coupling between arterial pressure, cerebral blood velocity, and cerebral tissue oxygenation with spontaneous and forced oscillations.

    abstract::We tested the hypothesis that transmission of arterial pressure to brain tissue oxygenation is low under conditions of arterial pressure instability. Two experimental models of hemodynamic instability were used in healthy human volunteers; (1) oscillatory lower body negative pressure (OLBNP) (N = 8; 5 male, 3 female),...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/4/785

    authors: Rickards CA,Sprick JD,Colby HB,Kay VL,Tzeng YC

    更新日期:2015-04-01 00:00:00

  • Association between RR interval and high-frequency heart rate variability acquired during short-term, resting recordings with free and paced breathing.

    abstract::High-frequency (HF) oscillations in RR interval from 0.15-0.40 Hz are widely accepted as a measure of cardiac vagal outflow but the HF/RR relationship appears complex, particularly with longer RR intervals. The aim of this study was to evaluate the HF/RR interval relationship during free and paced breathing. HF power ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/29/7/008

    authors: Sandercock G,Gladwell V,Dawson S,Nunan D,Brodie D,Beneke R

    更新日期:2008-07-01 00:00:00

  • Electrical impedance myography at frequencies up to 2 MHz.

    abstract::Extension of the frequency range of electrical impedance myography (EIM) to 2 MHz discloses a major rise in the reactance of muscle above 3-500 kHz, together with a slow decrease in the resistance consonant with the Kramers-Kronig relations. This 'upturn' phenomenon is found when the distant current electrode configur...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/29/6/S29

    authors: Shiffman CA,Kashuri H,Aaron R

    更新日期:2008-06-01 00:00:00

  • Wearable oxygen uptake and energy expenditure monitors.

    abstract::Obesity is a major health issue in both developed and developing countries. The balance between energy intake and exercise is important, and measurements of both energy intake and energy expenditure are required. Many studies have attempted to monitor energy intake via wearable technology, but no standard methods have...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/ab3827

    authors: Tamura T

    更新日期:2019-09-03 00:00:00

  • A CT perfusion based model predicts outcome in wake-up stroke patients treated with recombinant tissue plasminogen activator.

    abstract:OBJECTIVE:Advanced neuroimaging has proved to be pivotal in the management of acute ischemic stroke. The use of CT perfusion (CTP) core and penumbra parameters to predict the outcome in wake-up stroke (WUS) patients in everyday clinical scenarios has not yet been investigated. The aim of our study was to investigate th...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab9c70

    authors: Ajčević M,Furlanis G,Stella AB,Cillotto T,Caruso P,Ridolfi M,Lugnan C,Miladinović A,Ukmar M,Cova MA,Accardo A,Manganotti P,Naccarato M

    更新日期:2020-08-11 00:00:00

  • Monitoring of heart rate and inter-beat intervals with wrist plethysmography in patients with atrial fibrillation.

    abstract:OBJECTIVE:Atrial fibrillation (AF) causes marked risk for patients, while silent fibrillation may remain unnoticed if not suspected and screened. Development of comfortable yet accurate beat-to-beat heart rate (HR) monitoring with good AF detection sensitivity would facilitate screening and improve treatment. The purpo...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aac9a9

    authors: Harju J,Tarniceriu A,Parak J,Vehkaoja A,Yli-Hankala A,Korhonen I

    更新日期:2018-06-27 00:00:00

  • Arterial blood pressure measurement and pulse wave analysis--their role in enhancing cardiovascular assessment.

    abstract::The most common method of clinical measurement of arterial blood pressure is by means of the cuff sphygmomanometer. This instrument has provided fundamental quantitative information on arterial pressure in individual subjects and in populations and facilitated estimation of cardiovascular risk related to levels of blo...

    journal_title:Physiological measurement

    pub_type: 历史文章,杂志文章,评审

    doi:10.1088/0967-3334/31/1/R01

    authors: Avolio AP,Butlin M,Walsh A

    更新日期:2010-01-01 00:00:00

  • A method for comparative evaluation of EIT algorithms using a standard data set.

    abstract::The point spread function (PSF) is the most widely used tool for quantifying the spatial resolution of imaging systems. However, prerequisites for the proper use of this tool are linearity and space invariance. Because EIT is non-linear it is only possible to compare different reconstruction algorithms using a standar...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/16/3a/021

    authors: Ider YZ,Eyüboğlu BM,Kuzuoğlu M,Leblebïcïoğlu K,Baysal U,Cağlar BK,Bïrgül O

    更新日期:1995-08-01 00:00:00

  • Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study.

    abstract::In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major h...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/9/008

    authors: King J,Mochalski P,Kupferthaler A,Unterkofler K,Koc H,Filipiak W,Teschl S,Hinterhuber H,Amann A

    更新日期:2010-09-01 00:00:00

  • The variability of the photoplethysmographic signal--a potential method for the evaluation of the autonomic nervous system.

    abstract::The heart rate variability is composed of low- and high-frequency fluctuations, which are mediated by the sympathetic and the parasympathetic nervous systems. The baseline and the amplitude of the photoplethysmographic (PPG) signal also show fluctuations in the same frequencies. In the current study, PPG examinations ...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/19/1/008

    authors: Nitzan M,Babchenko A,Khanokh B,Landau D

    更新日期:1998-02-01 00:00:00

  • Detection of acute periodontal pain from physiological signals.

    abstract:OBJECTIVE:To investigate the feasibility of the detection of brief orofacial pain sensations from easily recordable physiological signals by means of machine learning techniques. APPROACH:A total of 47 subjects underwent periodontal probing and indicated each instance of pain perception by means of a push button. Simu...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aadf0c

    authors: Teichmann D,Klopp J,Hallmann A,Schuett K,Wolfart S,Teichmann M

    更新日期:2018-09-27 00:00:00

  • Wavelet-based real-time calculation of multiple physiological parameters on an embedded platform.

    abstract:OBJECTIVE:This paper aims to present how physiological signals can be processed based on wavelet decomposition to calculate multiple physiological parameters in real-time on an embedded platform. APPROACH:An ECG and PPG are decomposed to the appropriate scale based on a quadratic spline wavelet base in order to obtain...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab6f52

    authors: Tang M,Xia P,He Z,Zhao Z,Chen X,Yang T,Zhang Z,Zhan Q,Li X,Fang Z

    更新日期:2020-03-06 00:00:00

  • Monitoring fetal maturation-objectives, techniques and indices of autonomic function.

    abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/aa5fca

    authors: Hoyer D,Żebrowski J,Cysarz D,Gonçalves H,Pytlik A,Amorim-Costa C,Bernardes J,Ayres-de-Campos D,Witte OW,Schleußner E,Stroux L,Redman C,Georgieva A,Payne S,Clifford G,Signorini MG,Magenes G,Andreotti F,Malberg H,Zaun

    更新日期:2017-05-01 00:00:00

  • Chasing the evidence: the influence of data segmentation on estimates of dynamic cerebral autoregulation.

    abstract:OBJECTIVE:Transfer function analysis (TFA) of dynamic cerebral autoregulation (dCA) requires smoothing of spectral estimates using segmentation of the data (SD). Systematic studies are required to elucidate the potential influence of SD on dCA parameters. APPROACH:Healthy subjects (HS, n = 237) and acute ischaemic str...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/ab7ddf

    authors: Panerai RB,Intharakham K,Haunton V,Minhas JS,Llwyd O,Lam M,Salinet ASM,Nogueira RC,Katsogridakis E,Maggio P,Robinson TG

    更新日期:2020-04-17 00:00:00

  • Daily physical activity patterns from hip- and wrist-worn accelerometers.

    abstract::Accelerometer wear location may influence physical activity estimates. This study investigates this relationship through the examination of activity patterns throughout the day. Participants from the aging research evaluating accelerometry (AREA) study (n men  =  37, n women  =  47, mean age (SD)  =  78.9 (5.5) years)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/10/1852

    authors: Shiroma EJ,Schepps MA,Harezlak J,Chen KY,Matthews CE,Koster A,Caserotti P,Glynn NW,Harris TB

    更新日期:2016-10-01 00:00:00

  • An analytic solution to the homogeneous EIT problem on the 2D disk and its application to estimation of electrode contact impedances.

    abstract::An analytic solution of the potential distribution on a 2D homogeneous disk for electrical impedance tomography under the complete electrode model is expressed via an infinite system of linear equations. For the shunt electrode model with two electrodes, our solution coincides with the previously derived solution expr...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/008

    authors: Demidenko E

    更新日期:2011-09-01 00:00:00

  • Length and activation dependent variations in muscle shear wave speed.

    abstract::Muscle stiffness is known to vary as a result of a variety of disease states, yet current clinical methods for quantifying muscle stiffness have limitations including cost and availability. We investigated the capability of shear wave elastography (SWE) to measure variations in gastrocnemius shear wave speed induced v...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/34/6/713

    authors: Chernak LA,DeWall RJ,Lee KS,Thelen DG

    更新日期:2013-06-01 00:00:00

  • Linear and nonlinear characteristics of heart rate time series in obesity and during weight-reduction surgery.

    abstract::Obesity is associated with abnormal cardiac regulation by the autonomic nervous system (ANS), this being reversed by weight loss. Bariatric (weight-reduction) surgery can induce substantial long-term weight reductions. This study compares the acute influence on ANS control of two different types of bariatric surgery i...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/7/002

    authors: Alam I,Lewis MJ,Morgan J,Baxter J

    更新日期:2009-07-01 00:00:00

  • Determination of Cole parameters in multiple frequency bioelectrical impedance analysis using only the measurement of impedances.

    abstract::Conventional bioimpedance spectrometers measure resistance and reactance over a range of frequencies and, by application of a mathematical model for an equivalent circuit (the Cole model), estimate resistance at zero and infinite frequencies. Fitting of the experimental data to the model is accomplished by iterative, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/9/007

    authors: Ward LC,Essex T,Cornish BH

    更新日期:2006-09-01 00:00:00

  • A pH-mucosa area unit of measure to consider morphology of the oesophagus when evaluating oesophagitis.

    abstract::Gastro-oesophageal pH measurements are routinely carried out to quantify and determine if levels of acid reflux are responsible for symptoms. Although considered the 'gold standard', evidence suggests that pH measurements do not correlate well with the degree of oesophagitis seen during endoscopy. In this study the cu...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/24/4/006

    authors: Haylett KR,Vales P,Lee SH,McCloy RF

    更新日期:2003-11-01 00:00:00

  • Performance limits of ICA-based heart rate identification techniques in imaging photoplethysmography.

    abstract::Imaging photoplethysmography is a relatively new technique for extracting biometric information from video images of faces. This is useful in non-invasive monitoring of patients including neonates or the aged, with respect to sudden infant death syndrome, sleep apnoea, pulmonary disease, physical or mental stress and ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/1/67

    authors: Mannapperuma K,Holton BD,Lesniewski PJ,Thomas JC

    更新日期:2015-01-01 00:00:00