A CT perfusion based model predicts outcome in wake-up stroke patients treated with recombinant tissue plasminogen activator.

Abstract:

OBJECTIVE:Advanced neuroimaging has proved to be pivotal in the management of acute ischemic stroke. The use of CT perfusion (CTP) core and penumbra parameters to predict the outcome in wake-up stroke (WUS) patients in everyday clinical scenarios has not yet been investigated. The aim of our study was to investigate the predictive power of CTP parameters on functional and morphological outcomes in WUS patients treated with recombinant tissue plasminogen activator (rTPA). APPROACH:We analyzed clinical data and processed CTP images of 83 consecutive WUS patients treated with rTPA. The predictive power of whole-brain CTP features and of the clinical stroke-related parameters to predict the National Institutes of Health Stroke Scale (NIHSS) score at the seventh day and ischemic lesion volume outcome was investigated by means of multivariate regression analysis as well as least absolute shrinkage and selection operator (LASSO) modeling. MAIN RESULTS:Multivariate analysis showed that CTP core volume (β = 0.403, p = 0.000), NIHSS at admission (β = 0.323, p = 0.005) and Alberta Stroke Program Early CT (ASPECT) score (β = -0.224, p = 0.012) predict NIHSS at 7 days, while total hypoperfused volume (β = 0.542, p = 0.000) and core volume on CTP (β =0.441, p = 0.000) predict infarct lesion volume at follow-up CT. The LASSO modeling approach confirmed the significant predictive power of CTP core volume, total hypoperfused CTP volume, NIHSS at baseline and ASPECT score, producing a sparse model with adequate reliability (the root mean square error on a previously unseen testing dataset was 3.68). SIGNIFICANCE:Our findings highlight the importance of CT multimodal imaging features for decision-making and prediction in the hyperacute phase of WUS. The predictive model supports the hypothesis that an irreversible necrotic core rather than the extent of the penumbra is the main prognostic factor in WUS patients treated with rTPA.

journal_name

Physiol Meas

authors

Ajčević M,Furlanis G,Stella AB,Cillotto T,Caruso P,Ridolfi M,Lugnan C,Miladinović A,Ukmar M,Cova MA,Accardo A,Manganotti P,Naccarato M

doi

10.1088/1361-6579/ab9c70

subject

Has Abstract

pub_date

2020-08-11 00:00:00

pages

075011

issue

7

eissn

0967-3334

issn

1361-6579

journal_volume

41

pub_type

杂志文章
  • A novel curve fitting method for AV optimisation of biventricular pacemakers.

    abstract::In this study, we designed and tested a new algorithm, which we call the 'restricted parabola', to identify the optimum atrioventricular (AV) delay in patients with biventricular pacemakers. This algorithm automatically restricts the hemodynamic data used for curve fitting to the parabolic zone in order to avoid inadv...

    journal_title:Physiological measurement

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/0967-3334/36/9/1889

    authors: Dehbi HM,Jones S,Sohaib SM,Finegold JA,Siggers JH,Stegemann B,Whinnett ZI,Francis DP

    更新日期:2015-09-01 00:00:00

  • Time-related heart autonomic balance characteristics in healthy subjects.

    abstract::Changes of the heart autonomic balance between morning (8-9 h) and afternoon (14-15 h) measurements were studied in 22 healthy subjects. The selection of these two daytime periods was substantiated by the established higher risk of cardiovascular incidents in the morning and the relative balance of the vegetative nerv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/3/309

    authors: Matveev M,Prokopova R,Nachev Ch

    更新日期:2003-08-01 00:00:00

  • Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

    abstract::We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs)...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/15/1/004

    authors: Panescu D,Webster JG,Stratbucker RA

    更新日期:1994-02-01 00:00:00

  • In vivo bioimpedance changes during haemorrhagic and ischaemic stroke in rats: towards 3D stroke imaging using electrical impedance tomography.

    abstract::Electrical impedance tomography (EIT) could be used as a portable non-invasive means to image the development of ischaemic stroke or haemorrhage. The purpose of this study was to examine if this was possible using time difference imaging, in the anesthetised rat using 40 spring-loaded scalp electrodes with applied con...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/6/765

    authors: Dowrick T,Blochet C,Holder D

    更新日期:2016-06-01 00:00:00

  • Neuromagnetic field strength outside the human head due to impedance changes from neuronal depolarization.

    abstract::The holy grail of neuroimaging would be to have an imaging system, which could image neuronal electrical activity over milliseconds. One way to do this would be by imaging the impedance changes associated with ion channels opening in neuronal membranes in the brain during activity. In principle, we could measure this ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/25/1/040

    authors: Ahadzi GM,Liston AD,Bayford RH,Holder DS

    更新日期:2004-02-01 00:00:00

  • An automated quasi-continuous capillary refill timing device.

    abstract::Capillary refill time (CRT) is a simple means of cardiovascular assessment which is widely used in clinical care. Currently, CRT is measured through manual assessment of the time taken for skin tone to return to normal colour following blanching of the skin surface. There is evidence to suggest that manually assessed ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/37/1/83

    authors: Blaxter LL,Morris DE,Crowe JA,Henry C,Hill S,Sharkey D,Vyas H,Hayes-Gill BR

    更新日期:2016-01-01 00:00:00

  • The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercise.

    abstract::Cardiac output (CO) monitoring is not only essential for critically ill patients in the hospital, but also for patients at home and those undergoing cardiopulmonary exercise testing. However, CO is difficult to monitor during daily activities and exercise. In this paper, we aim at developing a novel CO estimation meth...

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/31/5/008

    authors: Wang L,Poon CC,Zhang YT

    更新日期:2010-05-01 00:00:00

  • A bio-telemetric device for measurement of left ventricular pressure-volume loops using the admittance technique in conscious, ambulatory rats.

    abstract::This paper presents the design, construction and testing of a device to measure pressure-volume loops in the left ventricle of conscious, ambulatory rats. Pressure is measured with a standard sensor, but volume is derived from data collected from a tetrapolar electrode catheter using a novel admittance technique. Ther...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/6/007

    authors: Raghavan K,Feldman MD,Porterfield JE,Larson ER,Jenkins JT,Escobedo D,Pearce JA,Valvano JW

    更新日期:2011-06-01 00:00:00

  • Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality.

    abstract::A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on indiv...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/33/9/1435

    authors: Di Marco LY,Duan W,Bojarnejad M,Zheng D,King S,Murray A,Langley P

    更新日期:2012-09-01 00:00:00

  • Assessment of 1-lead and 2-lead electrode patterns in electrical impedance endotomography.

    abstract::Electrical impedance endotomography (EIE) is a modality of impedance imaging where the electrodes are located on an insulating core placed at the centre of the region of interest. The absence of a physical limit to the medium surrounding the probe enables the use of remote electrodes. The present study compares the fe...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/4/001

    authors: Fournier-Desseux A,Jossinet J

    更新日期:2005-08-01 00:00:00

  • Home monitoring of within-breath respiratory mechanics by a simple and automatic forced oscillation technique device.

    abstract::Spirometry is the gold standard to determine the presence of airflow obstruction, but it requires volitional participation and needs qualified supervision. The forced oscillation technique (FOT) measures respiratory input impedance (Zrs) during spontaneous breathing and it could be useful for unsupervised monitoring o...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/4/N01

    authors: Dellacà RL,Gobbi A,Pastena M,Pedotti A,Celli B

    更新日期:2010-04-01 00:00:00

  • Pilot acute study of feedback-controlled retrograde peristalsis invoked by neural gastric electrical stimulation.

    abstract::Neural gastric electrical stimulation (NGES) is a new method for invoking gastric contractions under microprocessor control. However, optimization of this technique using feedback mechanisms to minimize power consumption and maximize effectiveness has been lacking. The present pilot study proposes a prototype feedback...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/30/3/006

    authors: Aelen P,Jurkov A,Aulanier A,Mintchev MP

    更新日期:2009-03-01 00:00:00

  • The physiological impact of the nonlinearity of arterial elasticity in the ambulatory arterial stiffness index.

    abstract::The ambulatory arterial stiffness index (AASI) is claimed to be a new estimator for arterial rigidity. It was recently defined as one minus the slope of the linear regression of systolic to diastolic ambulatory pressure during 24 h. Although several reports testify its clinical relevance, the explanation of how this n...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/7/012

    authors: Craiem D,Graf S,Salvucci F,Chironi G,Megnien JL,Simon A,Armentano RL

    更新日期:2010-07-01 00:00:00

  • Combining and benchmarking methods of foetal ECG extraction without maternal or scalp electrode data.

    abstract::Despite significant advances in adult clinical electrocardiography (ECG) signal processing techniques and the power of digital processors, the analysis of non-invasive foetal ECG (NI-FECG) is still in its infancy. The Physionet/Computing in Cardiology Challenge 2013 addresses some of these limitations by making a set ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/8/1569

    authors: Behar J,Oster J,Clifford GD

    更新日期:2014-08-01 00:00:00

  • Network proteomics of human dermal wound healing.

    abstract:OBJECTIVE:The healing of wounds is critical in protecting the human body against environmental factors. The mechanisms involving protein expression during this complex physiological process have not been fully elucidated. APPROACH:Here, we use reverse-phase protein microarrays (RPPA) involving 94 phosphoproteins to st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aaee19

    authors: Gao X,Petricoin EF 3rd,Ward KR,Goldberg SR,Duane TM,Bonchev D,Arodz T,Diegelmann RF

    更新日期:2018-12-07 00:00:00

  • Electrical biopsy of irradiated intestinal tissue with a simple electrical impedance spectroscopy system for radiation enteropathy in rats--a pilot study.

    abstract::Electrical impedance is one of the most often used parameters for characterizing material properties, especially in biomedical applications. Electrical impedance spectroscopy (EIS), used for revealing both resistive and capacitive characteristics, is good for use in tissue characterization. In this study, a portable a...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/32/9/010

    authors: Huang YJ,Huang EY,Lu YY,Chen CY,Cheng KS

    更新日期:2011-09-01 00:00:00

  • A comparison of methods for estimating left ventricular volumes from radionuclide ventriculography.

    abstract::An accurate reproducible measurement of left ventricular volume is important in the evaluation of cardiac disease. Four methods of left ventricular volume measurement by radionuclide ventriculography have been compared and their reproducibility assessed in a patient group. The methods studied were a geometric method, ...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/14/1/004

    authors: Thorley PJ,Sheard KL,Rees MR

    更新日期:1993-02-01 00:00:00

  • Noise sensitivity of three surface ECG fibrillation detection algorithms.

    abstract::The widening application of automatic external defibrillators (AEDs) presents very strong requirements for external electrocardiogram (ECG) signal analysis. Highly accurate detection of shockable rhythms is required, aimed to approach the maximum of 100% sensitivity and specificity. In a previous study the performance...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/22/2/302

    authors: Jekova I,Cansell A,Dotsinsky I

    更新日期:2001-05-01 00:00:00

  • Measurements of fluorine in contemporary urban Canadians: a comparison of the levels found in human bone using in vivo and ex vivo neutron activation analysis.

    abstract::Non-invasive in vivo neutron activation analysis (NAA) was used to measure the fluorine concentration in 35 people in Hamilton, Ontario, Canada. Measurement and precision data of this second generation NAA system were determined in 2013, and the results were compared with the performance of a first generation system u...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/36/3/465

    authors: Mostafaei F,McNeill FE,Chettle DR,Wainman BC,Pidruczny AE,Prestwich WV

    更新日期:2015-03-01 00:00:00

  • Effects of whole-body mechanical stimulation at double the heart rate on the blood pressure waveform in rats.

    abstract::The effects of mechanical stimulation on hemodynamics, such as due to mechanotransduction in vascular endothelial cells, have been widely discussed recently. We previously proposed a resonance model in which the arterial system is treated as a pressure-transmitting system, and suggested that the application of externa...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/27/2/004

    authors: Hsiu H,Jan MY,Wang WK,Wang YY

    更新日期:2006-02-01 00:00:00

  • Modelling the electrical properties of bladder tissue--quantifying impedance changes due to inflammation and oedema.

    abstract::Electrical impedance spectroscopy has been developed as a potential method for the diagnosis of carcinoma in epithelial tissues. An understanding of the influence of structural changes in the tissue on the properties measured using this technique is essential for interpreting measured data and optimization of probe de...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/26/3/010

    authors: Walker DC,Smallwood RH,Keshtar A,Wilkinson BA,Hamdy FC,Lee JA

    更新日期:2005-06-01 00:00:00

  • Monitoring fetal maturation-objectives, techniques and indices of autonomic function.

    abstract::Monitoring the fetal behavior does not only have implications for acute care but also for identifying developmental disturbances that burden the entire later life. The concept, of 'fetal programming', also known as 'developmental origins of adult disease hypothesis', e.g. applies for cardiovascular, metabolic, hyperki...

    journal_title:Physiological measurement

    pub_type: 杂志文章,评审

    doi:10.1088/1361-6579/aa5fca

    authors: Hoyer D,Żebrowski J,Cysarz D,Gonçalves H,Pytlik A,Amorim-Costa C,Bernardes J,Ayres-de-Campos D,Witte OW,Schleußner E,Stroux L,Redman C,Georgieva A,Payne S,Clifford G,Signorini MG,Magenes G,Andreotti F,Malberg H,Zaun

    更新日期:2017-05-01 00:00:00

  • Cardiac-related changes in lung resistivity as a function of frequency and location obtained from EITS images.

    abstract::ECG-gated electrical impedance tomographic spectroscopy (EITS) measurements of the lungs were taken on seven normal subjects in the frequency range 9.6 kHz to 614.4 kHz. The results show that in late systole the resistivity p' relative to the R-wave (i.e. p' = 1 at the R-wave) decreases consistently within the lung. I...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/17/4a/026

    authors: Nopp P,Zhao TX,Brown BH,Wang W

    更新日期:1996-11-01 00:00:00

  • Snore site discrimination using statistical moments of free field snoring sounds recorded during sleep nasendoscopy.

    abstract::The non-invasive measurement of free field snoring sounds to estimate the site of snoring is an important development in the diagnosis, treatment and management of sleep-related breathing disorders. We investigated characteristics of the probability density function by testing the sensitivity of the statistical moment...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/28/10/008

    authors: Beeton RJ,Wells I,Ebden P,Whittet HB,Clarke J

    更新日期:2007-10-01 00:00:00

  • Dynamic data monitoring improves predictive analytics for failed extubation in the ICU.

    abstract:OBJECTIVE:Predictive analytics monitoring that informs clinicians of the risk for failed extubation would help minimize both the duration of mechanical ventilation and the risk of emergency re-intubation in ICU patients. We hypothesized that dynamic monitoring of cardiorespiratory data, vital signs, and lab test result...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/1361-6579/aace95

    authors: Keim-Malpass J,Enfield KB,Calland JF,Lake DE,Clark MT

    更新日期:2018-07-16 00:00:00

  • Adaptive techniques in electrical impedance tomography reconstruction.

    abstract::We present an adaptive algorithm for solving the inverse problem in electrical impedance tomography. To strike a balance between the accuracy of the reconstructed images and the computational efficiency of the forward and inverse solvers, we propose to combine an adaptive mesh refinement technique with the adaptive Ka...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/35/6/1111

    authors: Li T,Isaacson D,Newell JC,Saulnier GJ

    更新日期:2014-06-01 00:00:00

  • Gastric activity studies using a magnetic tracer.

    abstract::A magnetic pulse generator has been set up in order to study gastric activity. Two coils 1.05 m in diameter, arranged in a Helmholtz configuration, were used. The system generated magnetic field pulses higher than 15 mT, of duration 17.3+/-1.2 ms. Measurements were performed in 11 male volunteers, with average age 29....

    journal_title:Physiological measurement

    pub_type: 临床试验,杂志文章

    doi:10.1088/0967-3334/25/5/015

    authors: Cordova-Fraga T,Bernal-Alvarado JJ,Gutierrez-Juarez G,Sosa M,Vargas-Luna M

    更新日期:2004-10-01 00:00:00

  • Static resistivity image of a cubic saline phantom in magnetic resonance electrical impedance tomography (MREIT).

    abstract::In magnetic resonance electrical impedance tomography (MREIT) we inject currents through electrodes placed on the surface of a subject and try to reconstruct cross-sectional resistivity (or conductivity) images using internal magnetic flux density as well as boundary voltage measurements. In this paper we present a st...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/24/2/367

    authors: Lee BI,Oh SH,Woo EJ,Lee SY,Cho MH,Kwon O,Seo JK,Baek WS

    更新日期:2003-05-01 00:00:00

  • Tracking time-varying cerebral autoregulation in response to changes in respiratory PaCO2.

    abstract::Cerebral autoregulation has been studied by linear filter systems, with arterial blood pressure (ABP) as the input and cerebral blood flow velocity (CBFV-from transcranial Doppler Ultrasound) as the output. The current work extends this by using adaptive filters to investigate the dynamics of time-varying cerebral aut...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/10/001

    authors: Liu J,Simpson MD,Yan J,Allen R

    更新日期:2010-10-01 00:00:00

  • A planar elliptical model of cardio-vagal hysteresis.

    abstract::The state-dependent portion of cardio-vagal baroreflex control is called baroreflex hyteresis: we observe hysteresis when RR interval and carotid diameter depend on both the direction and value of arterial pressure. The elasticity of arterial walls, as well as the responsiveness of central command reset controls the r...

    journal_title:Physiological measurement

    pub_type: 杂志文章

    doi:10.1088/0967-3334/31/6/009

    authors: Ler AS,Cohen MA,Taylor JA

    更新日期:2010-06-01 00:00:00