Assessment of normal flow patterns in the pulmonary circulation by using 4D magnetic resonance velocity mapping.

Abstract:

OBJECTIVE:The purpose of this study was to analyze flow patterns in the pulmonary circulation of healthy volunteers by using 4D flow magnetic resonance imaging. MATERIALS AND METHODS:The study was approved by the local ethics committee and all subjects gave written informed consent. Eighteen volunteers underwent a 4D flow scan of the whole-heart. Two patients with congenital heart disease were also included to detect possible patterns of flow abnormalities (Patient 1: corrected transposition of great arteries (TGA); Patient 2: partial anomalous pulmonary venous return and atrial septal defect). To analyze flow patterns, 2D planes were placed on the main pulmonary artery (PA), left and right PA. Flow patterns were assessed manually by two independent viewers using vector fields, streamlines and particle traces, and semi-automatically by vorticity quantification. RESULTS:Two counter-rotating helices were found in the main PA of volunteers. Right-handed helical flow was detected in the right PA of 15 volunteers. Analysis of the helical flow by particles traces revealed that both helices contributed mainly to the flow in the right PA. In the patient with corrected TGA helical flow was not detected. Abnormal vortical flow was visualized in the main PA of patient 2, suggesting elevated mean PA pressure. CONCLUSIONS:Helical flow is normally present in the main PA and right PA. 4D flow is an excellent tool to evaluate noninvasively complex blood flow patterns in the pulmonary circulation. Knowledge of normal and abnormal flow patterns might help to evaluate patients with congenital heart disease adding functional information undetectable with other imaging modalities.

journal_name

Magn Reson Imaging

authors

Bächler P,Pinochet N,Sotelo J,Crelier G,Irarrazaval P,Tejos C,Uribe S

doi

10.1016/j.mri.2012.06.036

subject

Has Abstract

pub_date

2013-02-01 00:00:00

pages

178-88

issue

2

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(12)00246-9

journal_volume

31

pub_type

杂志文章
  • Application of spherical harmonics derived space rotation invariant indices to the analysis of multiple sclerosis lesions' geometry by MRI.

    abstract::In the longitudinal study of multiple sclerosis (MS) lesions, varying position of the patient inside the MRI scanner is one of the major sources of assessment errors. We propose to use analytical indices that are invariant to spatial orientation to describe the lesions, rather than focus on patient repositioning or im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.053

    authors: Goldberg-Zimring D,Achiron A,Warfield SK,Guttmann CR,Azhari H

    更新日期:2004-07-01 00:00:00

  • Delayed myelination in a rhizomelic chondrodysplasia punctata case: MR spectroscopy findings.

    abstract::Rhizomelic chondrodysplasia punctata is a member of genetic peroxisomal disorders. Delayed myelination, which is probably related to the inadequacy of plasmalogens biosynthesis, is an important feature of this disorder. Direct assessment of neuropathologic aspects of RCDP syndrome such as neuronal degeneration and del...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00625-2

    authors: Alkan A,Kutlu R,Yakinci C,Sigirci A,Aslan M,Sarac K

    更新日期:2003-01-01 00:00:00

  • Abdominal aortic aneurysm evaluation: comparison of US, CT, MRI, and angiography.

    abstract::We studied 26 cases of abdominal aortic aneurysm with magnetic resonance imaging (MRI), computed tomography (CT), ultrasonography (US), and angiography. Data acquired were compared to those obtained at surgery. Diameter of the aneurysm was correctly defined in all cases by CT and MRI, while angiography underestimated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90089-k

    authors: Pavone P,Di Cesare E,Di Renzi P,Marsili L,Ventura M,Spartera C,Passariello R

    更新日期:1990-01-01 00:00:00

  • Magnetic resonance spectroscopy of the brain in neurologically asymptomatic HIV-infected patients.

    abstract::The CNS involvement is frequently found in human immunodeficiency virus (HIV) infection. The purpose of our study was to determine whether proton magnetic resonance spectroscopy (MRS) could detect early brain involvement in neurologically asymptomatic HIV-infected patients with normal MR imagings and to find the corre...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(00)00173-9

    authors: Suwanwelaa N,Phanuphak P,Phanthumchinda K,Suwanwela NC,Tantivatana J,Ruxrungtham K,Suttipan J,Wangsuphachart S,Hanvanich M

    更新日期:2000-09-01 00:00:00

  • Alterations in diffusion properties of white matter in Williams syndrome.

    abstract::Diffusion tensor imaging (DTI) was used to investigate the involvement of brain white matter in Williams syndrome (WS), a genetic neurodevelopmental disorder. Whole-brain DTIs were obtained from 16 young adults with WS and 16 normal controls. A voxel-based analysis was performed to compare fractional anisotropy (FA) v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.012

    authors: Arlinghaus LR,Thornton-Wells TA,Dykens EM,Anderson AW

    更新日期:2011-11-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • Anisotropic diffusion in etched particle tracks studied by field gradient NMR.

    abstract::Etched particle tracks produced after heavy ion irradiation of polymer foils are used as model systems to test the performance of NMR in a newly developed ultrahigh magnetic field gradient system. The stimulated NMR echo decay of molecules diffusing in the channels, formulated in terms of the self part of the intermed...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91527-x

    authors: Fujara F,Ilyina E,Nienstaedt H,Sillescu H,Spohr R,Trautmann C

    更新日期:1994-01-01 00:00:00

  • DUSTER: dynamic contrast enhance up-sampled temporal resolution analysis method.

    abstract::Dynamic contrast enhanced (DCE) MRI using Tofts' model for estimating vascular permeability is widely accepted, yet inter-tissue differences in bolus arrival time (BAT) are generally ignored. In this work we propose a method, incorporating the BAT in the analysis, demonstrating its applicability and advantages in heal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.014

    authors: Liberman G,Louzoun Y,Artzi M,Nadav G,Ewing JR,Ben Bashat D

    更新日期:2016-05-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • Tissue sodium concentration and sodium T1 mapping of the human brain at 3 T using a Variable Flip Angle method.

    abstract:PURPOSE:The state-of-the-art method to quantify sodium concentrations in vivo consists in a fully relaxed 3D spin-density (SD) weighted acquisition. Nevertheless, most sodium MRI clinical studies use short-TR SD acquisitions to reduce acquisition durations. We present a clinically viable implementation of the Variable ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.01.015

    authors: Coste A,Boumezbeur F,Vignaud A,Madelin G,Reetz K,Le Bihan D,Rabrait-Lerman C,Romanzetti S

    更新日期:2019-05-01 00:00:00

  • An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies.

    abstract::Quantitative cerebral blood flow (CBF) values can be determined from residue function estimates obtained from magnetic resonance dynamic susceptibility contrast (DSC) perfusion studies using a variety of deconvolution approaches. However, there are significant differences between the CBF estimates obtained, difference...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.12.001

    authors: Salluzzi M,Frayne R,Smith MR

    更新日期:2005-04-01 00:00:00

  • Short TI short TR inversion recovery imaging using reduced flip angles.

    abstract::In this paper the effects of reducing the flip angle of the 90-degree observation pulse in inversion recovery imaging are described and analyzed. When incorporated in an IR sequence with a short inversion time (STIR), reduction to the 90-degree pulse allows a significant shortening of the repetition time without loss ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90418-l

    authors: Bakker CJ,Witkamp TD,Janssen WM

    更新日期:1991-01-01 00:00:00

  • NMR in rotating magnetic fields: magic-angle field spinning.

    abstract::Magic-angle sample spinning is one of the cornerstones in high-resolution NMR of solid and semisolid materials. The technique enhances spectral resolution by averaging away rank 2 anisotropic spin interactions, thereby producing isotropic-like spectra with resolved chemical shifts and scalar couplings. In principle, i...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.067

    authors: Sakellariou D,Meriles CA,Martin RW,Pines A

    更新日期:2005-02-01 00:00:00

  • Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies.

    abstract::Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.002

    authors: Pfeuffer J,Shmuel A,Keliris GA,Steudel T,Merkle H,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Liposomal Gd-DTPA: effect of encapsulation on enhancement of hepatoma model by MRI.

    abstract::Liposomes entrapping gadolinium-DTPA (Gd-DTPA) were synthesized from 60 mole percent egg phosphatidylcholine (EPC) and 40 mole percent cholesterol or EPC alone entrapping Gd-DTPA in diameters of 100 and 200 nm. Rats bearing Morris hepatoma in their flanks were imaged by MR pre- and post-contrast with free Gd-DTPA and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90491-8

    authors: Unger EC,MacDougall P,Cullis P,Tilcock C

    更新日期:1989-07-01 00:00:00

  • High-resolution magnetic resonance flow imaging in a model of porous bone-implant interface.

    abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.11.001

    authors: Conroy MJ,Pédrono A,Bechtold JE,Søballe K,Ambard D,Swider P

    更新日期:2006-06-01 00:00:00

  • Determination of relaxation characteristics during preacute stage of lysophosphatidyl choline-induced demyelinating lesion in rat brain: an animal model of multiple sclerosis.

    abstract::Relaxation time measurements were carried out during the preacute stage of lesion progression in an animal model of demyelination created in the internal capsule (ic) area of the rat brain using lysophosphatidyl choline (LPC). T1 and T2 were determined both before and after 36 h of lesion creation. Histology carried o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.010

    authors: Degaonkar MN,Raghunathan P,Jayasundar R,Jagannathan NR

    更新日期:2005-01-01 00:00:00

  • SSFP fMRI at 3 tesla: Efficiency of polar acquisition-reconstruction technique.

    abstract::SSFP-based fMRI techniques, known for their high specificity and low geometrical distortion, look promising for high-resolution brain mapping. Nevertheless, they suffer from lack of speed and sensitivity, leading them to be exploited mostly in high-field scanners. Radial acquisition can help with these inefficiencies ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.005

    authors: Malekian V,Rastegar F,Shafieizargar B,Nasiraei-Moghaddam A

    更新日期:2020-12-01 00:00:00

  • MRI inter-slice reconstruction using super-resolution.

    abstract::MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, is...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00511-8

    authors: Greenspan H,Oz G,Kiryati N,Peled S

    更新日期:2002-06-01 00:00:00

  • Application of fuzzy c-means segmentation technique for tissue differentiation in MR images of a hemorrhagic glioblastoma multiforme.

    abstract::The application of a raw data-based, operator-independent MR segmentation technique to differentiate boundaries of tumor from edema or hemorrhage is demonstrated. A case of a glioblastoma multiforme with gross and histopathologic correlation is presented. The MR image data set was segmented into tissue classes based o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00093-i

    authors: Phillips WE 2nd,Velthuizen RP,Phuphanich S,Hall LO,Clarke LP,Silbiger ML

    更新日期:1995-01-01 00:00:00

  • Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

    abstract::The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an un...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(99)00134-4

    authors: Said B,McCart JA,Libutti SK,Choyke PL

    更新日期:2000-04-01 00:00:00

  • Quantitative SENSE-MRSI of the human brain.

    abstract:PURPOSE:To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain. MATERIALS AND METHODS:The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.11.003

    authors: Bonekamp D,Smith MA,Zhu H,Barker PB

    更新日期:2010-04-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • Accuracy and precision of quantitative DCE-MRI parameters: How should one estimate contrast concentration?

    abstract:INTRODUCTION:Pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE-MRI) data are sensitive to acquisition and post-processing techniques, which makes it difficult to compare results obtained using different methods. In particular, one of the most important factors affecting estimation of model para...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.05.007

    authors: Wake N,Chandarana H,Rusinek H,Fujimoto K,Moy L,Sodickson DK,Kim SG

    更新日期:2018-10-01 00:00:00

  • Perfusion MR imaging and proton MR spectroscopic imaging in differentiating necrotizing cerebritis from glioblastoma multiforme.

    abstract::We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physici...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.028

    authors: Pivawer G,Law M,Zagzag D

    更新日期:2007-02-01 00:00:00

  • Mri measurements of T1, T2 and D for gels undergoing volume phase transition.

    abstract::Gels consist of crosslinked polymer network swollen in solvent. The network of flexible long-chain molecules traps the liquid medium they are immersed in. Some gels undergo abrupt volume change, a phase transition process, by swelling-shrinking in response to external stimuli changes in solvent composition, temperatur...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00639-2

    authors: Yung KT

    更新日期:2003-02-01 00:00:00

  • Osteomyelitis: sensitivity of 0.064 T MRI, three-phase bone scanning and indium scanning with biopsy proof.

    abstract::We compared the ability of magnetic resonance imaging (MRI) using a 0.064 T permanent magnet, three-phase bone scanning, and indium-labeled white blood cell (111In-WBC) scanning, to diagnose osteomyelitis. Twenty-three patients underwent biopsy. All patients were examined at presentation with all three modalities. Sen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90540-3

    authors: Williamson MR,Quenzer RW,Rosenberg RD,Meholic AJ,Eisenberg B,Espinosa MC,Hartshorne MF

    更新日期:1991-01-01 00:00:00

  • Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T.

    abstract:PURPOSE:Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.023

    authors: Stamm AC,Wright CL,Knopp MV,Schmalbrock P,Heverhagen JT

    更新日期:2013-05-01 00:00:00