Ripple reduction control of the undulation pump total artificial heart.

Abstract:

:An undulation pump total artificial heart (UPTAH) in which the revolutions of the motor are converted to undulation motion of a disk has been developed. In an experiment, a goat using the UPTAH survived for 54 days. However, a large ripple was observed in the device's output pressure and flow waveform. In calculating the spectrum of the ripple, we found that the ripple mainly comprised 2 frequency sine waves: 1 having the same frequency as and 1 having double the frequency of the motor revolutions. To reduce the ripple, 2 sine waves, 1 having the same frequency as and 1 having double the frequency of the motor revolutions, were provided to the motor current to modulate the pulse width of the pulse width modulation controlling the motor revolutions. This ripple control method reduced the pressure ripple by 90% in a mock circulation and by 70% in animal experiments. These results revealed that the ripple generated in the UPTAH could be controlled through the use of motor control software.

journal_name

Artif Organs

journal_title

Artificial organs

authors

Saito I,Chinzei T,Mochizuki S,Abe Y,Isoyama T,Iwasaki K,Suzuki T,Karita T,Ono T,Kouno A,Ishimaru M,Baba A,Ozeki T,Tohyama T,Kobayashi Si S,Imachi K

doi

10.1046/j.1525-1594.2002.06798.x

subject

Has Abstract

pub_date

2002-01-01 00:00:00

pages

40-4

issue

1

eissn

0160-564X

issn

1525-1594

pii

aor6798

journal_volume

26

pub_type

杂志文章
  • Magnetic suspension of the rotor of a ventricular assist device of mixed flow type.

    abstract::This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (São Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2008.00551.x

    authors: Horikawa O,de Andrade AJ,da Silva I,Bock EG

    更新日期:2008-04-01 00:00:00

  • A human lymph node in vitro--challenges and progress.

    abstract::Extracorporeal human lymphatic organs are expected to be excellent tools in the study of human molecular and cellular bases of the immunologic balance and tissue harmony. A rational approach and process to design a device and a procedure to recreate the human lymph node environment in vitro is described with emphasis ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00303.x

    authors: Giese C,Demmler CD,Ammer R,Hartmann S,Lubitz A,Miller L,Müller R,Marx U

    更新日期:2006-10-01 00:00:00

  • Selective removal of circulating immune complexes from patient plasma.

    abstract::The principle of a patient-specific immunoadsorber (PsIA) is demonstrated. Studies with model systems (HSA/anti-HSA) on immobilization, stability, and leakage form the basis for the presented fast-performance liquid chromatography (FPLC) and batch experiments, which were conducted using two different protein A adsorbe...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06875.x

    authors: Kunkel S,Holtz M,Grossjohann B,Schuett W,Klinkmann H,Kong D,Yamada R,Kimura H,Matic GB,Ramlow W,Boeden HF

    更新日期:2002-02-01 00:00:00

  • Short hemodialysis: long-term mortality and morbidity.

    abstract::Individualized short hemodialysis treatment schedules, approximately three 3-h treatments per week, were introduced in a nephrology unit in 1976. In May 1985, 259 patients had been treated, which corresponds to approximately 60 new patients per million inhabitants per year. Ages at start of therapy ranged between 17 a...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1986.tb02541.x

    authors: Wauters JP,Bercini-Pansiot S,Gilliard N,Stauffer JC

    更新日期:1986-06-01 00:00:00

  • A computational study of the effects of inlet guide vanes on the performance of a centrifugal blood pump.

    abstract::This article presents computational studies on the effects of inlet guide vanes (IGVs) on the flow pattern and shear stress in a centrifugal blood pump. The effect of IGVs is to introduce a pre-swirl to fluid particles entering the impeller with the intention that the fluid particles will travel along the blade profil...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2002.06917.x

    authors: Chan WK,Wong YW,Yu SC,Chua LP

    更新日期:2002-06-01 00:00:00

  • Effects of uremic toxin p-cresol on proliferation, apoptosis, differentiation, and glucose uptake in 3T3-L1 cells.

    abstract::Malnutrition is a common feature seen in chronic dialysis patients, and the survival rate of obese patients receiving such treatment is higher than that of lean patients. Irrespective of obesity or diabetes, dialysis patients commonly have insulin resistance, and the leading cause of death is cardiovascular (CV) disea...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12252

    authors: Tanaka S,Yano S,Sheikh AM,Nagai A,Sugimoto T

    更新日期:2014-07-01 00:00:00

  • Significance of percutaneous cardiopulmonary bypass support for volume reduction surgery with severe hypercapnia.

    abstract::In patients with reduced respiratory function, lung resection is associated with high risk because separate ventilation is generally needed for safe management. For patients with end-stage emphysema, intraoperative respiratory management is important and particularly difficult because neither incomplete oxygenation no...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2000.06339.x

    authors: Tsunezuka Y,Sato H,Tsubota M,Seki M

    更新日期:2000-01-01 00:00:00

  • Techniques for optimization of pulsatile ventricular assist device support.

    abstract::For some time now researchers have argued the efficacy of pulsatile versus nonpulsatile hemodynamic support. Pulsatile systems, while providing a more physiological pumping source, are burdened with a multiparametric output function that can greatly affect the utility of such ventricular assist device (VAD) support. A...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00299.x

    authors: Mills TC,Ott RA

    更新日期:1992-04-01 00:00:00

  • Preservation of human saphenous vein against reactive oxygen species-induced oxidative stress by green tea polyphenol pretreatment.

    abstract::The injurious effects of reactive oxygen species on venous tissues and the potential protective role played by green tea polyphenol (GTPP) on human saphenous veins were investigated. Oxidative stress was induced exogenously in the vein segments, either by adding 0.8 or 1.6 M of H2O2, or by using 80 or 160 U/L of xanth...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2003.07163.x

    authors: Han DW,Suh H,Park YH,Cho BK,Hyon SH,Park JC

    更新日期:2003-12-01 00:00:00

  • The role of diastolic pump flow in centrifugal blood pump hemodynamics.

    abstract::We tried to verify the hypothesis that increases in pump flow during diastole are matched by decreases in left ventricular (LV) output during systole. A calf (80 kg) was implanted with an implantable centrifugal blood pump (EVAHEART, SunMedical Technology Research Corp., Nagano, Japan) with left ventricle to aorta (LV...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.06864.x

    authors: Akimoto T,Litwak KN,Yamazaki K,Litwak P,Kihara SI,Tagusari O,Yamazaki SI,Kameneva MV,Watach MJ,Umezu M,Tomioka J,Kormos RL,Koyanagi H,Griffith BP

    更新日期:2001-09-01 00:00:00

  • The monomeric formulation optimization of dental composite: mechanical and kinetic studies.

    abstract::The optimization of the monomer composition, using a polymerization kinetic study and the mechanical behavior study of the composites, was the principal objective of this work. The monomeric mixture analyzed is a part of the composite that has been in development at the University of Campinas, Brazil. Parameters such ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2003.07250.x

    authors: López Palacio RE,de Carvalho Zavaglia CA

    更新日期:2003-05-01 00:00:00

  • Influence of flow design on microcirculation in conditions of undulation pump-left ventricle assist device testing.

    abstract::To study the microvessels in bulbar conjunctiva, we conducted an experiment in goat with a pneumatically driven left heart bypass pump, which was replaced with an undulation pump-left ventricle assist device for 9 days. Three flow patterns were tested: complete pulsatile, continuous, and percentage of pulsatile. We st...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00244.x

    authors: Dobsák P,Novakova M,Baba A,Vasku J,Isoyama T,Saito I,Abe Y,Chinzei T,Imachi K

    更新日期:2006-06-01 00:00:00

  • Influence of middle molecules on the anemia of uremic patients.

    abstract::To evaluate their toxicity at the cellular level, middle molecules from uremic serum were incubated with erythrocytes from healthy subjects and the activity of the enzyme Delta-aminolevulinic acid dehydrase (D-ALA-D) and peroxidative hemolysis were investigated. Uremic middle molecules caused a significant decrease of...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1978.tb01626.x

    authors: Leber HW,Spiegelhalter R,Ulm A,Goubeaud G,Rawer P

    更新日期:1978-11-01 00:00:00

  • Can We Develop a Nonpulsatile Permanent Rotary Blood Pump? Yes, We Can.

    abstract::For many years, it was thought that nonpulsatile perfusion produced physiological and circulatory abnormalities. Since 1977, Yukihiko Nosé and his colleagues have challenged this misconception. Toward that end, they did show that if a 20% higher blood flow uses more than that required for a pulsatile blood pump, then ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1996.tb04466.x

    authors: Nosé Y,Kawahito K,Nakazawa T

    更新日期:1996-05-01 00:00:00

  • The impact of polyethylene glycol conjugation on bovine hemoglobin's circulatory half-life and renal effects in a rabbit top-loaded transfusion model.

    abstract::This study compares the effects of polyethylene glycol (PEG) modified bovine hemoglobin on vascular half-life and renal function in rabbits to those of unmodified bovine hemoglobin. Renal function was assessed by the measurement of the glomerular filtration rate, urinalysis, blood chemistries, hemoglobin (Hb) excretio...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1997.tb00250.x

    authors: Conover CD,Gilbert CW,Shum KL,Shorr RG

    更新日期:1997-08-01 00:00:00

  • Development of an atraumatic small centrifugal pump for second-generation cardiopulmonary bypass.

    abstract::A small and light direct-drive centrifugal pump has been developed for cardiopulmonary bypass. In the development process, blood compatibility studies including a hemolysis study, an in vitro fluid dynamic performance study, and in vivo durability and feasibility studies were performed. The centrifugal pump with a 50 ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1992.tb00558.x

    authors: Jikuya T,Sasaki T,Aizawa T,Shiono M,Glueck JA,Smith CP,Feldman L,Sakuma I,Sekela ME,Noda T

    更新日期:1992-12-01 00:00:00

  • Testosterone and hemoglobin in hemodialysis male and female patients.

    abstract::It has been speculated that testosterone stimulates erythropoiesis. We hypothesized that hemoglobin levels in hemodialysis (HD) patients are associated with serum testosterone concentrations. Testosterone, hemoglobin, and other biochemical parameters were measured in a representative sample of 98 chronic HD patients (...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12218

    authors: Ekart R,Taskovska M,Hojs N,Bevc S,Hojs R

    更新日期:2014-07-01 00:00:00

  • Artificial matrix helps neonatal cardiomyocytes restore injured myocardium in rats.

    abstract::The purpose of this study was to investigate whether an artificial matrix can help neonatal cardiomyocytes restore an injured heart in a rat model of myocardial infarction (MI). The left coronary arteries of female Sprague Dawley (SD) rats were ligated to create MI models. Ventricular cardiomyocytes from 1- to 3-day-o...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00186.x

    authors: Zhang P,Zhang H,Wang H,Wei Y,Hu S

    更新日期:2006-02-01 00:00:00

  • Numerical estimation of hemolysis from the point of view of signal and system.

    abstract::The power-law based models for predicting shear-induced hemolysis are widely used in the optimization design of blood-contacting devices. However, this category of models has fallen short of accuracy when compared with the results of the in vitro experiments. The aim of this study is to develop an alternative model fr...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12294

    authors: Li H,Ruan X,Qian W,Fu X

    更新日期:2014-12-01 00:00:00

  • Pump Speed Waveform Analysis to Detect Aortic Valve Opening in Patients on Ventricular Assist Device Support.

    abstract::As the aortic valve (AV) opens, the pump pressure head remains constant, which is reflected as a "notch/plateau" in pump pressure and flow signals. However, instantaneous flow estimation may be influenced by friction and is particularly difficult in axial pumps. Therefore, a new method to determine the duration of AV ...

    journal_title:Artificial organs

    pub_type: 杂志文章,多中心研究

    doi:10.1111/aor.12570

    authors: Hayward C,Lim CP,Schima H,Macdonald P,Moscato F,Muthiah K,Granegger M

    更新日期:2015-08-01 00:00:00

  • Are standard human coagulation tests suitable in pigs and calves during extracorporeal circulation?

    abstract::The thrombogenicity of membrane oxygenators as well as clotting parameters profiles, using standard human clotting tests, was analyzed in calves and pigs during 6 h perfusion. Three calves and 3 pigs were connected to extracorporeal circulation with standard heparinization. Blood samples were taken for coagulation var...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1046/j.1525-1594.2001.025007579.x

    authors: Mueller XM,Tevaearai HT,Jegger D,Tucker O,von Segesser LK

    更新日期:2001-07-01 00:00:00

  • Timing of Intra-Aortic Balloon Pump Placement Before Off-Pump Coronary Artery Bypass Grafting and Clinical Outcomes.

    abstract::We aimed to evaluate the timing of preoperative intra-aortic balloon pump (IABP) placement and outcomes in patients undergoing off-pump coronary artery bypass grafting (OPCAB). Patients with prophylactic IABP placement before OPCAB presenting between January 1, 2010 and December 31, 2013 were included. Patients were c...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13009

    authors: Liu F,Yang F,Du Z,Miao N,Zhao Y,Xu B,Hou X

    更新日期:2018-03-01 00:00:00

  • Estimation of phosphene spatial variability for visual prosthesis applications.

    abstract::Visual prostheses are the focus of intensive research efforts to restore some measure of useful vision to blind or near-blind patients. The development of such technology is being guided to an extent by tools that simulate prosthesis behavior for healthy sighted subjects in order to assess system requirements and conf...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2009.00878.x

    authors: Obeid I,Veraart C,Delbeke J

    更新日期:2010-05-01 00:00:00

  • Engineering of vascular grafts with genetically modified bone marrow mesenchymal stem cells on poly (propylene carbonate) graft.

    abstract::Bone marrow mesenchymal stem cells (MSCs) have demonstrated their pluripotency to differentiate into different cell lineages and may be an alternative cell source for vascular tissue engineering. The objective of this study is to create small diameter vessels by seeding and culture of genetically modified MSCs onto a ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.2006.00322.x

    authors: Zhang J,Qi H,Wang H,Hu P,Ou L,Guo S,Li J,Che Y,Yu Y,Kong D

    更新日期:2006-12-01 00:00:00

  • A new smartphone-based method for wound area measurement.

    abstract::Proper wound healing can be assessed by monitoring the wound surface area. Its reduction by 10 or 50% should be achieved after 1 or 4 weeks, respectively, from the start of the applied therapy. There are various methods of wound area measurement, which differ in terms of the cost of the devices and their accuracy. Thi...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12169

    authors: Foltynski P,Ladyzynski P,Wojcicki JM

    更新日期:2014-04-01 00:00:00

  • The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    abstract::Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12959

    authors: Glynn J,Song H,Hull B,Withers S,Gelow J,Mudd J,Starr A,Wampler R

    更新日期:2017-10-01 00:00:00

  • Probing expert opinions on the future of kidney replacement therapies.

    abstract::Patients with kidney failure can only survive with some form of kidney replacement (transplant or dialysis). Unfortunately, innovations in kidney replacement therapy lag behind many other medical fields. This study compiles expert opinions on candidate technologies for future kidney replacement therapies. A worldwide ...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.13784

    authors: Pereira Cabral B,Bonventre JV,Wieringa F,Mota FB

    更新日期:2020-07-22 00:00:00

  • Simple evaluation method of biocompatibility of artificial oxygenator hollow fiber.

    abstract::We made miniature modules filled with artificial oxygenator hollow fibers and conducted a simple experiment to study the effect of different membrane structures on the blood. Three types of modules were made: one filled with polyolefin, one filled with polypropylene, and a blank module. The 3 modules were connected th...

    journal_title:Artificial organs

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1525-1594.1996.tb00677.x

    authors: Nishida H,Shibuya M,Endo M,Koyanagi H

    更新日期:1996-12-01 00:00:00

  • Apheresis technologies: an international perspective.

    abstract::The developments in apheresis techniques and their clinical applications world-wide are technologically driven. In the past, apheresis survey statistics have high-lighted both the differences by region in clinical practice and in the types of technologies utilized. Such differences have provided a basis for the scient...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/j.1525-1594.1995.tb02334.x

    authors: Malchesky PS,Bambauer R,Horiuchi T,Kaplan A,Sakurada Y,Samuelsson G

    更新日期:1995-04-01 00:00:00

  • Anticoagulation with fondaparinux for hemodiafiltration in patients with heparin-induced thrombocytopenia: dose-finding study and safety evaluation.

    abstract::The optimal anticoagulation regimen for hemodialysis (HD) in patients with heparin-induced thrombocytopenia (HIT) has not been defined. Hemodiafiltration (HDF) adds a large convective component to HD, thereby changing the pharmacokinetics of most anticoagulants. Data on coagulation regimens for HDF are scant. We there...

    journal_title:Artificial organs

    pub_type: 杂志文章

    doi:10.1111/aor.12002

    authors: Mahieu E,Claes K,Jacquemin M,Evenepoel P,Op De Beek K,Bogaert AM,Kuypers D,Verhamme P,Meijers B

    更新日期:2013-05-01 00:00:00