Abstract:
:Understanding the mechanical response of the brain to external loadings is of critical importance in investigating the pathological conditions of this tissue during injurious conditions. Such injurious loadings may occur at high rates, for example among others, during road traffic or sport accidents, falls, or due to explosions. Hence, investigating the injury mechanism and design of protective devices for the brain requires constitutive modeling of this tissue at such rates. Accordingly, this paper is aimed at critically investigating the physical background for viscohyperelastic modeling of the brain tissue with scrutinizing the elastic fields pertinent to large, time dependent deformations, and developing a fully nonlinear multimode Maxwell model that can mathematically explain such deformations. The proposed model can be calibrated using the simple monotonic uniaxial deformation of the sample extracted from the tissue, and does not require additional information from relaxation or creep experiments. The performance of the proposed model is examined using the experimental results of two different studies, which reveals a desirable agreement. The usefulness, limitations, and future developments of the proposed model are discussed in this paper.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Samadi-Dooki A,Voyiadjis GZdoi
10.1016/j.jbiomech.2019.01.007subject
Has Abstractpub_date
2019-02-14 00:00:00pages
211-217eissn
0021-9290issn
1873-2380pii
S0021-9290(19)30036-3journal_volume
84pub_type
杂志文章abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110040
更新日期:2020-11-09 00:00:00
abstract::Nuclear magnetic resonance (MR) can be used to measure velocities in fluid flow using the technique of phase velocity mapping. Advantages of MR velocimetry include the simultaneous mapping of the entire flow field through a non-contacting, magnetic window. The phase velocity mapping technique assumes that velocity is ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:
更新日期:1996-12-01 00:00:00
abstract::The topographical distributions of the zonal properties of articular cartilage over the medial tibia from an experimental osteoarthritis (OA) model were evaluated as a function of external loading by microscopic Magnetic Resonance Imaging (µMRI). T2 relaxation times and cartilage thicknesses were measured at 17.6 µm r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.011
更新日期:2015-10-15 00:00:00
abstract::High-resolution voxel-based finite element software, such as FEEBE developed at the NCBES, is widely used for studying trabecular bone at the micro-scale. A new approach to determine heterogeneous bone tissue material properties for computational models was proposed in this study. The specimen-specific range of tissue...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.05.014
更新日期:2008-08-07 00:00:00
abstract::Computational models have the potential to provide precise estimates of stresses and strains associated with sites of coronary plaque rupture. However, lack of adequate mathematical description of diseased human vessel wall mechanical properties is hindering computational accuracy. The goal of this study is to charact...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.019
更新日期:2012-03-15 00:00:00
abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.005
更新日期:2015-09-18 00:00:00
abstract::The African Spiny Mouse (Acomys spp.) is a unique outbred mammal capable of full, scar-free skin regeneration. In vivo, we have observed rapid reepithelialization and deposition of normal dermis in Acomys after wounding. Acomys skin also has a lower modulus and lower elastic energy storage than normal lab mice, Mus mu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.10.005
更新日期:2018-11-16 00:00:00
abstract::A new six-degree-of-freedom force transducer has been manufactured, with the sensitivity to measure forces in the range +/-100 N and moments of up to +/-5 Nm. The transducer incorporates two mechanical components: shear forces and bending moments are measured via a strain-gauged tubular section whilst axial forces are...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00054-8
更新日期:1999-07-01 00:00:00
abstract::Poisson's ratio has not been experimentally measured earlier for meniscus in compression. It is however an important intrinsic material property needed in biomechanical analysis and computational models. In this study, equilibrium Poisson's ratio of bovine meniscus (n = 6) was determined experimentally by combining st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.001
更新日期:2018-08-22 00:00:00
abstract::Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.05.038
更新日期:2009-09-18 00:00:00
abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.07.025
更新日期:2008-10-20 00:00:00
abstract::Lower limb amputation substantially disrupts motor and proprioceptive function. People with lower limb amputation experience considerable impairments in walking ability, including increased fall risk. Understanding the biomechanical aspects of the gait of these patients is crucial in improving their gait function and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.02.033
更新日期:2014-05-07 00:00:00
abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.06.030
更新日期:2008-01-01 00:00:00
abstract::Hyaline joint cartilage has only a limited potential for self-repair. Some of the published techniques for osteochondral defect therapy try to improve that potential. In this study, it was hypothesised that one of those surgical techniques, the crushed transplanted bone graft together with a collagen membrane, acceler...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.02.021
更新日期:2007-01-01 00:00:00
abstract::Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simul...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.06.005
更新日期:2006-01-01 00:00:00
abstract::Local dynamic stability has been assessed by the short-term local divergence exponent (λS), which quantifies the average rate of logarithmic divergence of infinitesimally close trajectories in state space. Both increased and decreased local dynamic stability at faster walking speeds have been reported. This might pert...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.09.020
更新日期:2014-11-28 00:00:00
abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109939
更新日期:2020-08-26 00:00:00
abstract::Respiratory assessment and the biomechanical analysis of chest and abdomen motion during breathing can be carried out using motion capture systems. An advantage of this methodology is that it allows analysis of compartmental breathing volumes, thoraco-abdominal patterns, percentage contribution of each compartment and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.05.036
更新日期:2018-07-25 00:00:00
abstract::Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-4...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90039-x
更新日期:1987-01-01 00:00:00
abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.035
更新日期:2014-09-22 00:00:00
abstract::Simple models are widely used to understand the mechanics of human walking. The optimization-based minimal biped model and spring-loaded-inverted-pendulum (SLIP) model are two popular models that can achieve human-like walking patterns. However, ground reaction forces (GRF) from these two models still deviate from exp...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.04.028
更新日期:2019-06-11 00:00:00
abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.06.017
更新日期:2009-09-18 00:00:00
abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.06.030
更新日期:2009-10-16 00:00:00
abstract::Biomechanical theories to predict bone remodelling have used either mechanical strain or microdamage as the stimulus driving cellular responses. Even though experimental data have implicated both stimuli in bone cell regulation, a mechano-regulatory system incorporating both stimuli has not yet been proposed. In this ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.05.007
更新日期:2007-01-01 00:00:00
abstract::The optimal sterilization method for load bearing allografts remains a clinical concern. Recently, supercritical carbon dioxide (SCCO2) treatments have been shown to be capable of terminally sterilizing a range of bacteria and viruses, while preserving the static mechanical properties of cortical bone. This study eval...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.04.006
更新日期:2013-06-21 00:00:00
abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.02.005
更新日期:2007-01-01 00:00:00
abstract::A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushio...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00034-7
更新日期:1998-04-01 00:00:00
abstract::Limb salvage surgeries are performed to treat a variety of lower limb pathologies and traumatic injuries. Individuals who have undergone limb salvage surgeries may require an ankle foot orthosis (AFO) to compensate for limb impairments and restore walking ability. Understanding the effects of AFO design parameters on ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.06.037
更新日期:2017-08-16 00:00:00
abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109344
更新日期:2019-11-11 00:00:00
abstract::Recent dielectric measurements suggest that the electromechanical effect in wet (fluid saturated) bone is not due to a piezoelectric effect. This would imply that the electromechanical effect observed in wet bone is due to a streaming potential and is therefore dependent on fluid flow in stressed bone. A model for flu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90054-9
更新日期:1982-01-01 00:00:00