A fully nonlinear viscohyperelastic model for the brain tissue applicable to dynamic rates.

Abstract:

:Understanding the mechanical response of the brain to external loadings is of critical importance in investigating the pathological conditions of this tissue during injurious conditions. Such injurious loadings may occur at high rates, for example among others, during road traffic or sport accidents, falls, or due to explosions. Hence, investigating the injury mechanism and design of protective devices for the brain requires constitutive modeling of this tissue at such rates. Accordingly, this paper is aimed at critically investigating the physical background for viscohyperelastic modeling of the brain tissue with scrutinizing the elastic fields pertinent to large, time dependent deformations, and developing a fully nonlinear multimode Maxwell model that can mathematically explain such deformations. The proposed model can be calibrated using the simple monotonic uniaxial deformation of the sample extracted from the tissue, and does not require additional information from relaxation or creep experiments. The performance of the proposed model is examined using the experimental results of two different studies, which reveals a desirable agreement. The usefulness, limitations, and future developments of the proposed model are discussed in this paper.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Samadi-Dooki A,Voyiadjis GZ

doi

10.1016/j.jbiomech.2019.01.007

subject

Has Abstract

pub_date

2019-02-14 00:00:00

pages

211-217

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30036-3

journal_volume

84

pub_type

杂志文章
  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • The accuracy of magnetic resonance phase velocity measurements in stenotic flow.

    abstract::Nuclear magnetic resonance (MR) can be used to measure velocities in fluid flow using the technique of phase velocity mapping. Advantages of MR velocimetry include the simultaneous mapping of the entire flow field through a non-contacting, magnetic window. The phase velocity mapping technique assumes that velocity is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Siegel JM Jr,Oshinski JN,Pettigrew RI,Ku DN

    更新日期:1996-12-01 00:00:00

  • Loading-induced changes on topographical distributions of the zonal properties of osteoarthritic tibial cartilage--A study by magnetic resonance imaging at microscopic resolution.

    abstract::The topographical distributions of the zonal properties of articular cartilage over the medial tibia from an experimental osteoarthritis (OA) model were evaluated as a function of external loading by microscopic Magnetic Resonance Imaging (µMRI). T2 relaxation times and cartilage thicknesses were measured at 17.6 µm r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.011

    authors: Lee JH,Badar F,Kahn D,Matyas J,Qu X,Xia Y

    更新日期:2015-10-15 00:00:00

  • Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties.

    abstract::High-resolution voxel-based finite element software, such as FEEBE developed at the NCBES, is widely used for studying trabecular bone at the micro-scale. A new approach to determine heterogeneous bone tissue material properties for computational models was proposed in this study. The specimen-specific range of tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.014

    authors: Harrison NM,McDonnell PF,O'Mahoney DC,Kennedy OD,O'Brien FJ,McHugh PE

    更新日期:2008-08-07 00:00:00

  • Planar biaxial characterization of diseased human coronary and carotid arteries for computational modeling.

    abstract::Computational models have the potential to provide precise estimates of stresses and strains associated with sites of coronary plaque rupture. However, lack of adequate mathematical description of diseased human vessel wall mechanical properties is hindering computational accuracy. The goal of this study is to charact...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.019

    authors: Kural MH,Cai M,Tang D,Gwyther T,Zheng J,Billiar KL

    更新日期:2012-03-15 00:00:00

  • Effect of non-Newtonian fluid properties on bovine sperm motility.

    abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.005

    authors: Hyakutake T,Suzuki H,Yamamoto S

    更新日期:2015-09-18 00:00:00

  • Unique behavior of dermal cells from regenerative mammal, the African Spiny Mouse, in response to substrate stiffness.

    abstract::The African Spiny Mouse (Acomys spp.) is a unique outbred mammal capable of full, scar-free skin regeneration. In vivo, we have observed rapid reepithelialization and deposition of normal dermis in Acomys after wounding. Acomys skin also has a lower modulus and lower elastic energy storage than normal lab mice, Mus mu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.005

    authors: Stewart DC,Serrano PN,Rubiano A,Yokosawa R,Sandler J,Mukhtar M,Brant JO,Maden M,Simmons CS

    更新日期:2018-11-16 00:00:00

  • A force transducer to measure individual finger loads during activities of daily living.

    abstract::A new six-degree-of-freedom force transducer has been manufactured, with the sensitivity to measure forces in the range +/-100 N and moments of up to +/-5 Nm. The transducer incorporates two mechanical components: shear forces and bending moments are measured via a strain-gauged tubular section whilst axial forces are...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00054-8

    authors: Fowler NK,Nicol AC

    更新日期:1999-07-01 00:00:00

  • Poisson's ratio of bovine meniscus determined combining unconfined and confined compression.

    abstract::Poisson's ratio has not been experimentally measured earlier for meniscus in compression. It is however an important intrinsic material property needed in biomechanical analysis and computational models. In this study, equilibrium Poisson's ratio of bovine meniscus (n = 6) was determined experimentally by combining st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.001

    authors: Danso EK,Julkunen P,Korhonen RK

    更新日期:2018-08-22 00:00:00

  • Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.

    abstract::Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.038

    authors: Bryan R,Nair PB,Taylor M

    更新日期:2009-09-18 00:00:00

  • Microcracking damage and the fracture process in relation to strain rate in human cortical bone tensile failure.

    abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.025

    authors: Zioupos P,Hansen U,Currey JD

    更新日期:2008-10-20 00:00:00

  • Dynamic stability of individuals with transtibial amputation walking in destabilizing environments.

    abstract::Lower limb amputation substantially disrupts motor and proprioceptive function. People with lower limb amputation experience considerable impairments in walking ability, including increased fall risk. Understanding the biomechanical aspects of the gait of these patients is crucial in improving their gait function and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.033

    authors: Beurskens R,Wilken JM,Dingwell JB

    更新日期:2014-05-07 00:00:00

  • Translational constraint influences dynamic spinal canal occlusion of the thoracic spine: an in vitro experimental study.

    abstract::Mechanical constraints to spine motion can arise in a variety of real-world situations such as when shoulder belts prevent anterior translation of the thorax during automotive collisions. The effect of such constraint on spinal column-spinal cord interaction during injury remains unknown. The purpose of the present st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.030

    authors: Zhu Q,Lane C,Ching RP,Gordon JD,Fisher CG,Dvorak MF,Cripton PA,Oxland TR

    更新日期:2008-01-01 00:00:00

  • Crushed bone grafts and a collagen membrane are not suitable for enhancing cartilage quality in the regeneration of osteochondral defects--an in vivo study in sheep.

    abstract::Hyaline joint cartilage has only a limited potential for self-repair. Some of the published techniques for osteochondral defect therapy try to improve that potential. In this study, it was hypothesised that one of those surgical techniques, the crushed transplanted bone graft together with a collagen membrane, acceler...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.021

    authors: Schell H,Lienau J,Kleemann RU,Schlichting K,Taylor WR,Weiler A,Duda GN

    更新日期:2007-01-01 00:00:00

  • Sensitivity of a Hill-based muscle model to perturbations in model parameters.

    abstract::Musculoskeletal simulations of human movement commonly use Hill muscle models to predict muscle forces, but their sensitivity to model parameter values is not well understood. The purpose of this study was to evaluate muscle model sensitivity to perturbations in 14 Hill muscle model parameters in forward dynamic simul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.06.005

    authors: Scovil CY,Ronsky JL

    更新日期:2006-01-01 00:00:00

  • The effect of walking speed on local dynamic stability is sensitive to calculation methods.

    abstract::Local dynamic stability has been assessed by the short-term local divergence exponent (λS), which quantifies the average rate of logarithmic divergence of infinitesimally close trajectories in state space. Both increased and decreased local dynamic stability at faster walking speeds have been reported. This might pert...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.09.020

    authors: Stenum J,Bruijn SM,Jensen BR

    更新日期:2014-11-28 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Comparison of marker models for the analysis of the volume variation and thoracoabdominal motion pattern in untrained and trained participants.

    abstract::Respiratory assessment and the biomechanical analysis of chest and abdomen motion during breathing can be carried out using motion capture systems. An advantage of this methodology is that it allows analysis of compartmental breathing volumes, thoraco-abdominal patterns, percentage contribution of each compartment and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.036

    authors: Massaroni C,Piaia Silvatti A,Levai IK,Dickinson J,Winter S,Schena E,Silvestri S

    更新日期:2018-07-25 00:00:00

  • Photogrammetric technique applied to anthropometric study of hands.

    abstract::Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-4...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90039-x

    authors: Ghosh SK,Poirier F

    更新日期:1987-01-01 00:00:00

  • Mechanical properties vary for different regions of the finger extensor apparatus.

    abstract::The extensor apparatus, an aponeurosis that covers the dorsal side of each finger, transmits force from a number of musculotendons to the phalanges. Multiple tendons integrate directly into the structure at different sites and the extensor apparatus attaches to the phalanges at multiple points. Thus, prediction of the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.035

    authors: Qian K,Traylor K,Lee SW,Ellis B,Weiss J,Kamper D

    更新日期:2014-09-22 00:00:00

  • An actuated dissipative spring-mass walking model: Predicting human-like ground reaction forces and the effects of model parameters.

    abstract::Simple models are widely used to understand the mechanics of human walking. The optimization-based minimal biped model and spring-loaded-inverted-pendulum (SLIP) model are two popular models that can achieve human-like walking patterns. However, ground reaction forces (GRF) from these two models still deviate from exp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.028

    authors: Li T,Li Q,Liu T

    更新日期:2019-06-11 00:00:00

  • Statistical osteoporosis models using composite finite elements: a parameter study.

    abstract::Osteoporosis is a widely spread disease with severe consequences for patients and high costs for health care systems. The disease is characterised by a loss of bone mass which induces a loss of mechanical performance and structural integrity. It was found that transverse trabeculae are thinned and perforated while ver...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.017

    authors: Wolfram U,Schwen LO,Simon U,Rumpf M,Wilke HJ

    更新日期:2009-09-18 00:00:00

  • Kinematic evaluation of cruciate-retaining total knee replacement patients during level walking: a comparison with the displacement-controlled ISO standard.

    abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.030

    authors: Ngai V,Wimmer MA

    更新日期:2009-10-16 00:00:00

  • Bone remodelling algorithms incorporating both strain and microdamage stimuli.

    abstract::Biomechanical theories to predict bone remodelling have used either mechanical strain or microdamage as the stimulus driving cellular responses. Even though experimental data have implicated both stimuli in bone cell regulation, a mechano-regulatory system incorporating both stimuli has not yet been proposed. In this ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.007

    authors: McNamara LM,Prendergast PJ

    更新日期:2007-01-01 00:00:00

  • The effect of sterilization on the dynamic mechanical properties of paired rabbit cortical bone.

    abstract::The optimal sterilization method for load bearing allografts remains a clinical concern. Recently, supercritical carbon dioxide (SCCO2) treatments have been shown to be capable of terminally sterilizing a range of bacteria and viruses, while preserving the static mechanical properties of cortical bone. This study eval...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.006

    authors: Russell N,Rives A,Bertollo N,Pelletier MH,Walsh WR

    更新日期:2013-06-21 00:00:00

  • The influence of material property and morphological parameters on specimen-specific finite element models of porcine vertebral bodies.

    abstract::The use of finite element (FE) methods in spinal research is increasing, but there is only limited information available on the influence of different input parameters on the model predictions. The aim of this study was to investigate the role of these parameters in FE models of the vertebral body. Experimental tests ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.02.005

    authors: Wilcox RK

    更新日期:2007-01-01 00:00:00

  • A comparative tribological study of the wear of composite cushion cups in a physiological hip joint simulator.

    abstract::A composite cushion acetabular cup for a total hip replacement has been designed and developed jointly by Leeds University and DePuy International. In order to assess the long-term performance of this novel design, two sets of simulator tests of more than 4 million cycles duration have been carried out with the cushio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00034-7

    authors: Bigsby RJ,Auger DD,Jin ZM,Dowson D,Hardaker CS,Fisher J

    更新日期:1998-04-01 00:00:00

  • The effect of ankle foot orthosis alignment on walking in individuals treated for traumatic lower extremity injuries.

    abstract::Limb salvage surgeries are performed to treat a variety of lower limb pathologies and traumatic injuries. Individuals who have undergone limb salvage surgeries may require an ankle foot orthosis (AFO) to compensate for limb impairments and restore walking ability. Understanding the effects of AFO design parameters on ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.037

    authors: Brown SE,Russell Esposito E,Wilken JM

    更新日期:2017-08-16 00:00:00

  • A comparison of methods to quantify control of the spine.

    abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109344

    authors: Bourdon E,Graham RB,van Diëen J

    更新日期:2019-11-11 00:00:00

  • Fluid flow in bone in vitro.

    abstract::Recent dielectric measurements suggest that the electromechanical effect in wet (fluid saturated) bone is not due to a piezoelectric effect. This would imply that the electromechanical effect observed in wet bone is due to a streaming potential and is therefore dependent on fluid flow in stressed bone. A model for flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90054-9

    authors: Johnson MW,Chakkalakal DA,Harper RA,Katz JL,Rouhana SW

    更新日期:1982-01-01 00:00:00