Abstract:
:Recent dielectric measurements suggest that the electromechanical effect in wet (fluid saturated) bone is not due to a piezoelectric effect. This would imply that the electromechanical effect observed in wet bone is due to a streaming potential and is therefore dependent on fluid flow in stressed bone. A model for fluid flow in bone in vitro is presented. This model predicts a rapid decay (of the order of a millisecond or less) for the fluid flow in Haversian systems. The implications of this result for the interpretation of the electromechanical effect in wet bone are discussed.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Johnson MW,Chakkalakal DA,Harper RA,Katz JL,Rouhana SWdoi
10.1016/0021-9290(82)90054-9subject
Has Abstractpub_date
1982-01-01 00:00:00pages
881-5issue
11eissn
0021-9290issn
1873-2380pii
0021-9290(82)90054-9journal_volume
15pub_type
杂志文章abstract::Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a tread...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.12.046
更新日期:2015-04-13 00:00:00
abstract::The influence of the ductility of bone tissue on whole-bone strength represents a fundamental issue of multi-scale biomechanics. To gain insight, we performed a computational study of 16 human proximal femurs and 12 T9 vertebral bodies, comparing the whole-bone strength for the two hypothetical bounding cases of fully...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.066
更新日期:2015-05-01 00:00:00
abstract::A finite element model was used to investigate the counter-intuitive experimental observation that some regions of the aponeuroses of a loaded and contracting muscle may shorten rather than undergo an expected lengthening. The model confirms the experimental findings and suggests that pennation angle plays a significa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.01.005
更新日期:2010-05-07 00:00:00
abstract::A series of 33 human femoral bones have been subjected to a four point bending test at high strain rates. Two different failure modes were recognized. A Y shaped fracture at the middle region induced by a pure bending moment yielded a zone of non-linearity at the load vs deformation curve and a higher bending force, m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(86)90021-7
更新日期:1986-01-01 00:00:00
abstract::Strength, or maximum joint torque, is a fundamental factor governing human movement, and is regularly assessed for clinical and rehabilitative purposes as well as for research into human performance. This study aimed to identify the most appropriate protocol for fitting a maximum voluntary torque function to experimen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.11.024
更新日期:2011-03-15 00:00:00
abstract::Studying mechanics of the muscles spanning multiple joints provides insights into intersegmental dynamics and movement coordination. Multiarticular muscles are thought to function at "near-isometric" lengths to transfer mechanical energy between the adjacent body segments. Flexor hallucis longus (FHL) is a multiarticu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.03.040
更新日期:2008-01-01 00:00:00
abstract::Transcatheter aortic valve replacement (TAVR) is an established treatment alternative to surgical valve replacement in high-risk patients with severe symptomatic aortic stenosis. The current guidelines for TAVR are to upsize transcatheter aortic valve (TAV) relative to the native annulus to secure the device and minim...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.012
更新日期:2015-10-15 00:00:00
abstract::Cerebral vasculature is several orders of magnitude stiffer than the brain tissue. However, only a handful of studies have investigated its potential stiffening effect on dynamic brain strains; yet, they report contradictory findings. Here, we reanalyze the cerebrovascular stiffening effect by incorporating vasculatur...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109732
更新日期:2020-05-07 00:00:00
abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.02.003
更新日期:2011-04-07 00:00:00
abstract::Seated ergometer pedaling is a motor task ideal for studying basic mechanisms of human bipedal coordination because, in contrast to standing and walking, fewer degrees of freedom are being controlled and upright balance is not a factor. As a step toward understanding how individual muscles coordinate pedaling, we inve...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00011-9
更新日期:1996-01-01 00:00:00
abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)84545-3
更新日期:1996-11-01 00:00:00
abstract::Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3k...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.008
更新日期:2010-02-10 00:00:00
abstract::For the purpose of detecting early aberrations of gait in rheumatoid arthritis 17 women suffering from that disease were examined. They were all under 50 years of age and had an essentially normal range of motility in the hips, knees and ankles. Eleven healthy women walking at voluntary speed and 6 healthy women walki...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90237-0
更新日期:1988-01-01 00:00:00
abstract::Static stretching is a major type of mechanical stimuli utilized during distraction osteogenesis (DO), a general surgical method for the lengthening of bone. The molecular signals that drive the regenerative process in DO include a variety of cytokines. Among these, bone morphogenic protein (BMP, -2 and -4) has been r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.08.006
更新日期:2009-12-11 00:00:00
abstract::Comprehensive characterization of stress relaxation in musculotendinous structures is needed to create robust models of viscoelastic behavior. The commonly used quasi-linear viscoelastic (QLV) theory requires that the relaxation response be independent of tissue strain (length). This study aims to characterize stress ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.11.017
更新日期:2010-03-22 00:00:00
abstract::Wave speed (also called pulse wave velocity) is the speed by which disturbance travels along the medium and it depends on the mechanical and geometrical properties of the vessel and on the density of the blood. Wave speed is a parameter of clinical relevance because it is an indicator of arterial stiffness and cardiov...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.10.007
更新日期:2014-01-03 00:00:00
abstract::Intraoperative digitization of osseous structures is an integral component of computer-assisted orthopaedic surgery. This study determined the repeatability and accuracy of predicting known radii and center locations of spherical objects for different proportions of digitized surface areas and various sphere sizes. Al...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.01.018
更新日期:2009-05-29 00:00:00
abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.028
更新日期:2007-01-01 00:00:00
abstract::Valgus moments on the knee joint during single-leg landing have been suggested as a risk factor for anterior cruciate ligament (ACL) injury. The purpose of this study was to test the influence of isolated valgus moment on ACL strain during single-leg landing. Physiologic levels of valgus moments from an in vivo study ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.10.031
更新日期:2009-02-09 00:00:00
abstract::To enhance the wearability of portable motion-monitoring devices, the size and number of sensors are minimized, but at the expense of quality and quantity of data collected. For example, owing to the size and weight of low-frequency force transducers, most currently available wearable gait measurement systems provide ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.046
更新日期:2018-04-11 00:00:00
abstract::Adult articular cartilage has depth-dependent mechanical and biochemical properties which contribute to zone-specific functions. The compressive moduli of immature cartilage and tissue-engineered cartilage are known to be lower than those of adult cartilage. The objective of this study was to determine if such tissues...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.11.002
更新日期:2007-01-01 00:00:00
abstract::Fluid percussion injury (FPI) is a widely used experimental model for studying traumatic brain injury (TBI). However, little is known about how the brain mechanically responds to fluid impacts and how the mechanical pressures/strains of the brain correlate to subsequent brain damage for rodents during FPI. Hence, we d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.07.004
更新日期:2018-08-22 00:00:00
abstract::Knowledge of accurate in-vivo 6 degree-of-freedom (6-DOF) kinematics of total hip arthroplasty (THA) during daily activities is critical for improvement of longevity of the components. Previous studies assessed in-vivo THA kinematics using skin marker-based motion analysis. However, skin markers are prone to move with...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.012
更新日期:2014-05-07 00:00:00
abstract::Inertial measurement unit systems (IMU) are increasingly used in sports. However, no algorithm evaluating the instantaneous swimming velocity has been validated on the four swimming strokes, or on dive start. Our objective is to develop and validate a new method to measure instantaneous swimming velocity on athletes p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2021.110261
更新日期:2021-01-19 00:00:00
abstract::The pleural surfaces of the chest wall and lung slide against each other, lubricated by pleural fluid. During sliding motion of soft tissues, shear induced hydrodynamic pressure deforms the surfaces, promoting uniformity of the fluid layer thickness, thereby reducing friction. To assess pleural deformability at length...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.008
更新日期:2011-09-23 00:00:00
abstract::A new six-degree-of-freedom force transducer has been manufactured, with the sensitivity to measure forces in the range +/-100 N and moments of up to +/-5 Nm. The transducer incorporates two mechanical components: shear forces and bending moments are measured via a strain-gauged tubular section whilst axial forces are...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00054-8
更新日期:1999-07-01 00:00:00
abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90022-7
更新日期:1982-01-01 00:00:00
abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.05.001
更新日期:2011-07-07 00:00:00
abstract::A three-dimensional finite element model of the human head is presented. The model has been validated against two sets of experimental results. To assess injury likelihood of the head subjected to impact loading, the structural intensity (SI) methodology is introduced in accordance with the prevailing practice in expe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.11.015
更新日期:2006-01-01 00:00:00
abstract::Three-dimensional dynamic suspension is becoming an effective cell culture method for a wide range of bioprocesses, with an increasing number of bioreactors proposed for this purpose. The complex hydrodynamics establishing within these devices affects bioprocess outcomes and efficiency, and usually expensive in vitro ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.07.021
更新日期:2019-09-20 00:00:00