Musculoskeletal stiffness changes linearly in response to increasing load during walking gait.

Abstract:

:Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a treadmill at a constant preferred walking velocity while nine different backpack loading conditions ranging from 12.5% to 40% bodyweight (BW) were introduced in an ascending and then descending order. Kinematic data were collected using Optotrak, a 3D motion analysis system, and used to estimate the position of the center of mass (COM). Two different estimates of stiffness were computed for the stance phase of gait. Both measures of stiffness were positively and linearly related to load magnitudes, with the slopes of the relationships being larger for the descending than the ascending conditions. These results indicate that changes in mechanical stiffness brought about in the musculoskeletal system vary systematically during increases in load to ensure that critical kinematic variables measured in a previous publication remain invariant (Caron et al., 2013). Changes in stiffness and other kinematics measured at the 40% BW condition suggest a boundary in which gait stiffness control limit is reached and a new gait pattern is required. Since soldiers are now carrying up to 96% of body weight, the need for research with even heavier loads is warranted. These findings have implications on the development of exoskeletons to assist in carrying loads.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Caron RR,Lewis CL,Saltzman E,Wagenaar RC,Holt KG

doi

10.1016/j.jbiomech.2014.12.046

subject

Has Abstract

pub_date

2015-04-13 00:00:00

pages

1165-71

issue

6

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00714-3

journal_volume

48

pub_type

杂志文章
  • Shoe midsole hardness, sex and age effects on lower extremity kinematics during running.

    abstract::Previous studies investigating the effects of shoe midsole hardness on running kinematics have often used male subjects from within a narrow age range. It is unknown whether shoe midsole hardness has the same kinematic effect on male and female runners as well as runners from different age categories. As sex and age h...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.03.027

    authors: Nigg BM,Baltich J,Maurer C,Federolf P

    更新日期:2012-06-01 00:00:00

  • The effect of centre of mass location on sagittal plane moments around the centre of mass in trotting horses.

    abstract::The diagonal limb support pattern at trot provides pitch and roll stability, but little is known about the control of moments about the centre of mass (COM) in horses. Correct COM location is critical in the calculation of pitching moments. The objectives were to determine the effect of COM location on pitching moment...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.02.024

    authors: Hobbs SJ,Richards J,Clayton HM

    更新日期:2014-04-11 00:00:00

  • Osteochondral graft fixation using a bioresorbable bone cement.

    abstract::Multiple osteochondral grafts can be used to resurface large joint defects in both humans and horses. In humans, immediate postoperative weight bearing can be prevented, however in the equine, it is unavoidable. Early weight bearing can create detrimental graft micromotion. The aim of this study was to investigate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.007

    authors: Changoor A,Hurtig MB,John Runciman R

    更新日期:2006-01-01 00:00:00

  • Active axial stress in mouse aorta.

    abstract::The study verifies the development of active axial stress in the wall of mouse aorta over a range of physiological loads when the smooth muscle cells are stimulated to contract. The results obtained show that the active axial stress is virtually independent of the magnitude of pressure, but depends predominately on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.05.025

    authors: Agianniotis A,Rachev A,Stergiopulos N

    更新日期:2012-07-26 00:00:00

  • Hip endoprosthesis for in vivo measurement of joint force and temperature.

    abstract::Friction between the prosthetic head and acetabular cup increases the temperature in hip implants during activities like walking. A hip endoprosthesis was instrumented with sensors to measure the joint contact forces and the temperature distribution along the entire length of the titanium implant. Sensors and two indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00110-4

    authors: Graichen F,Bergmann G,Rohlmann A

    更新日期:1999-10-01 00:00:00

  • Analysis of swimmers' velocity during the underwater gliding motion following grab start.

    abstract::The purpose of this study was to determine the swimmers' loss of speed during the underwater gliding motion of a grab start. This study also set out to determine the kinematical variables influencing this loss of speed. Eight French national-level swimmers participated in this study. The swimmers were filmed using 4 m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.032

    authors: Elipot M,Hellard P,Taïar R,Boissière E,Rey JL,Lecat S,Houel N

    更新日期:2009-06-19 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • Water in hydroxyapatite nanopores: Possible implications for interstitial bone fluid flow.

    abstract::The role of bone water in the activity of this organ is essential in structuring apatite crystals, providing pathways for nutrients and waste involved in the metabolism of bone cells and participating in bone remodelling mechanotransduction. It is commonly accepted that bone presents three levels of porosity, namely t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.025

    authors: Lemaire T,Pham TT,Capiez-Lernout E,de Leeuw NH,Naili S

    更新日期:2015-09-18 00:00:00

  • Skewness angle of interfibrillar proteoglycans increases with applied load on mitral valve chordae tendineae.

    abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.011

    authors: Liao J,Vesely I

    更新日期:2007-01-01 00:00:00

  • On practical evaluation of differentiation techniques for human gait analysis.

    abstract::Numerical differentiation of noisy measurement data represents a problem frequently encountered in the field of gait analysis. There are two major determinants of the quality in calculated derivatives, namely the quality of the measurement data and the quality of the used differentiation technique. The quality of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90041-0

    authors: Lanshammar H

    更新日期:1982-01-01 00:00:00

  • Using regression models to determine the poroelastic properties of cartilage.

    abstract::The feasibility of determining biphasic material properties using regression models was investigated. A transversely isotropic poroelastic finite element model of stress relaxation was developed and validated against known results. This model was then used to simulate load intensity for a wide range of material proper...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.028

    authors: Chung CY,Mansour JM

    更新日期:2013-07-26 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • Estimation of the Young's modulus of articular cartilage using an arthroscopic indentation instrument and ultrasonic measurement of tissue thickness.

    abstract::We evaluated whether the use of cartilage thickness measurement would improve the ability of the arthroscopic indentation technique to estimate the intrinsic stiffness of articular cartilage. First, cartilage thickness and ultrasound reflection from the surface of bovine humeral head were registered in situ using a hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00189-5

    authors: Töyräs J,Lyyra-Laitinen T,Niinimäki M,Lindgren R,Nieminen MT,Kiviranta I,Jurvelin JS

    更新日期:2001-02-01 00:00:00

  • Three-dimensional finite element analysis of glass-ceramic dental crowns.

    abstract::Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90008-q

    authors: Hojjatie B,Anusavice KJ

    更新日期:1990-01-01 00:00:00

  • Squeeze-film lubrication of the human ankle joint with synovial fluid filtrated by articular cartilage with the superficial zone worn out.

    abstract::A squeeze-film lubrication model of the human ankle joint in standing that takes into account the fluid transport across the articular surface is presented. Articular cartilage is a biphasic mixture of the ideal interstitial fluid and an elastic permeable isotropic homogeneous intrinsically incompressible matrix. The ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00109-3

    authors: Hlavácek M

    更新日期:2000-11-01 00:00:00

  • Instantaneous velocity estimation for the four swimming strokes using a 3-axis accelerometer: Validation on paralympic athletes.

    abstract::Inertial measurement unit systems (IMU) are increasingly used in sports. However, no algorithm evaluating the instantaneous swimming velocity has been validated on the four swimming strokes, or on dive start. Our objective is to develop and validate a new method to measure instantaneous swimming velocity on athletes p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2021.110261

    authors: Clément J,Charbonneau M,Thompson M

    更新日期:2021-01-19 00:00:00

  • Membrane permeability during pressure ulcer formation: A computational model of dynamic competition between cytoskeletal damage and repair.

    abstract::Pressure ulcers are debilitating wounds that arise frequently in people who have lost mobility. Mechanical stress, oxidative stress and ischemia-reperfusion injury are potential sources of damage during pressure ulcer formation, but cross-talk between these sources has rarely been investigated. In vitro experiments wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.022

    authors: Jagannathan NS,Tucker-Kellogg L

    更新日期:2016-05-24 00:00:00

  • Mechanics of toe and heel landing in stepping down in ongoing gait.

    abstract::When stepping down from a height difference in ongoing gait, subjects are known to use a heel landing at small height differences and switch to toe landing for larger height differences. We hypothesized that in toe landing, the leading leg can perform more negative work, to control the momentum gained during the desce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.022

    authors: van Dieën JH,Spanjaard M,Könemann R,Bron L,Pijnappels M

    更新日期:2008-08-07 00:00:00

  • Feasibility of noninvasive evaluation of biophysical properties of tissue-engineered cartilage by using quantitative MRI.

    abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.002

    authors: Miyata S,Numano T,Homma K,Tateishi T,Ushida T

    更新日期:2007-01-01 00:00:00

  • Mechanical response of a simple finite element model of the intervertebral disc under complex loading.

    abstract::A simple axisymmetric finite element model of a human spine segment containing two adjacent vertebrae and the intervening intervertebral disc was constructed. The bodies and disc were modeled by three substructures; one to represent each of the vertebral bodies, the annulus fibrosus, and the nucleus pulposus. A semi-a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90128-3

    authors: Spilker RL,Daugirda DM,Schultz AB

    更新日期:1984-01-01 00:00:00

  • Modeling of biodynamic responses distributed at the fingers and the palm of the human hand-arm system.

    abstract::The objective of this study is to develop analytical models for simulating driving-point biodynamic responses distributed at the fingers and palm of the hand under vibration along the forearm direction (z(h)-axis). Two different clamp-like model structures are formulated to analyze the distributed responses at the fin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.10.031

    authors: Dong RG,Dong JH,Wu JZ,Rakheja S

    更新日期:2007-01-01 00:00:00

  • Does weightlifting increase residual force enhancement?

    abstract::The force maintained following stretching of an active muscle exceeds the isometric force at the same muscle length. This residual force enhancement (RFE) is different for various muscles. It is currently unknown whether training induces changes in RFE. Weightlifters perform a large number of eccentric contractions du...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.017

    authors: Siebert T,Kurch D,Blickhan R,Stutzig N

    更新日期:2016-07-05 00:00:00

  • Isolated changes in femoral version do not alter intra-articular contact mechanics in cadaveric hips.

    abstract::Abnormal femoral version is a deformity in the angle between the femoral neck and the transcondylar axis of the knee. Both femoral anteversion and retroversion alter passive and active rotation of the hip and are associated with intra-articular or extra-articular impingement. However, little is known about the effect ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109891

    authors: Meyer AM,Thomas-Aitken HD,Brouillette MJ,Westermann RW,Goetz JE

    更新日期:2020-08-26 00:00:00

  • On the importance of blood rheology for bulk flow in hemodynamic models of the carotid bifurcation.

    abstract::Here we present a study on the impact of assumptions on image-based hemodynamic simulations of healthy carotid bifurcations. In particular, we evaluate to which extent assumptions on blood rheology influence bulk flow features, driven by the fact that few studies have provided adequate insights into the influence of a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.028

    authors: Morbiducci U,Gallo D,Massai D,Ponzini R,Deriu MA,Antiga L,Redaelli A,Montevecchi FM

    更新日期:2011-09-02 00:00:00

  • A passive dynamic walking robot that has a deterministic nonlinear gait.

    abstract::There is a growing body of evidence that the step-to-step variations present in human walking are related to the biomechanics of the locomotive system. However, we still have limited understanding of what biomechanical variables influence the observed nonlinear gait variations. It is necessary to develop reliable mode...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.007

    authors: Kurz MJ,Judkins TN,Arellano C,Scott-Pandorf M

    更新日期:2008-01-01 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • In-vivo analysis of thoracic mechanical response under belt loading: the role of body mass index in thorax stiffness.

    abstract::Thoracic injuries are a major cause of mortality in frontal collisions, especially for elderly and obese people. Car occupant individual characteristics like BMI are known to influence human vulnerability in crashes. In the present study, thoracic mechanical response of volunteers quantified by optical method was link...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.12.021

    authors: Poulard D,Bermond F,Compigne S,Bruyère K

    更新日期:2013-03-15 00:00:00

  • Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions.

    abstract::Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.023

    authors: Chevalier Y,Matsuura M,Krüger S,Fleege C,Rickert M,Rauschmann M,Schilling C

    更新日期:2018-03-21 00:00:00

  • Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

    abstract::The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.027

    authors: Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

    更新日期:2006-01-01 00:00:00

  • The effect of step-wise increased stretching on rat calvarial osteoblast collagen production.

    abstract::Mechanical forces regulate the function of bone cells. In this paper, the effects of cyclic stretching on osteoblasts derived from rat calvaria were studied at a magnitude occurring in physiological loaded bone tissue. A four-point bending apparatus was used to apply cyclic stretching on osteoblasts. Stretching at 500...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00237-9

    authors: Tang LL,Wang YL,Pan J,Cai SX

    更新日期:2004-01-01 00:00:00