Feasibility of noninvasive evaluation of biophysical properties of tissue-engineered cartilage by using quantitative MRI.

Abstract:

:The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of the water molecules in the tissue is correlated with its biomechanical property. Therefore, magnetic resonance imaging (MRI) represents a potential approach to assess the biophysical property of the engineered cartilage. In this study, we test the hypothesis that quantitative MRI can be used as a noninvasive assessment method to assess the biophysical property of the engineered cartilage. To reconstruct a model of cartilaginous tissue, chondrocytes harvested from the humeral head of calves were embedded in an agarose gel and cultured in vitro up to 4 weeks. Equilibrium Young's moduli were determined from the stress relaxation tests. After mechanical testing, MRI-derived parameters (longitudinal relaxation time T1, transverse relaxation time T2, and water self-diffusion coefficient D) were measured. The equilibrium Young's modulus of the engineered cartilage showed a tendency to increase with an increase in the culture time, whereas T1 and D decreased. Based on a regression analysis, T1 and D showed a strong correlation with the equilibrium Young's modulus. The results showed that T1 and D values derived from the MRI measurements could be used to noninvasively monitor the biophysical properties of the engineered cartilage.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Miyata S,Numano T,Homma K,Tateishi T,Ushida T

doi

10.1016/j.jbiomech.2007.02.002

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

2990-8

issue

13

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(07)00070-X

journal_volume

40

pub_type

杂志文章
  • Changes in segment mass and mass distribution during pregnancy.

    abstract::The purpose of the study was to evaluate the rates of change in the estimated masses and principal moments of inertia of the body segments during the second and third trimesters of pregnancy. Fifteen subjects, on average 15.1 weeks pregnant, were tested monthly until term. The body was modelled as 16 segments consisti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00042-9

    authors: Jensen RK,Doucet S,Treitz T

    更新日期:1996-02-01 00:00:00

  • Velocity profiles in the wake of two prosthetic heart valves using a new cardiovascular simulator.

    abstract::In this paper we present a study of the post valvular flow field on a new cardiovascular simulator including an elastic model of the aortic arch. Transverse and vertical two-dimensional velocity measurements are performed with an ultrasonic velocimeter. Two prosthetic heart valves are tested in the aortic position. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90054-5

    authors: Farahifar D,Cassot F,Bodard H,Pelissier R

    更新日期:1985-01-01 00:00:00

  • Micromechanical modeling of elastic properties of cortical bone accounting for anisotropy of dense tissue.

    abstract::The paper analyzes the connection between microstructure of the osteonal cortical bone and its overall elastic properties. The existing models either neglect anisotropy of the dense tissue or simplify cortical bone microstructure (accounting for Haversian canals only). These simplifications (related mostly to insuffic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.019

    authors: Salguero L,Saadat F,Sevostianov I

    更新日期:2014-10-17 00:00:00

  • Density and hydration of fresh and fixed human skeletal muscle.

    abstract::The maximum tetanic tension of skeletal muscle (P(0)) is often estimated based on calculation of physiological cross-sectional area (PCSA). PCSA depends on muscle volume, pennation angle, and fiber length. Studies documenting PCSA in fixed human muscles usually compute muscle volume by dividing muscle mass by density....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.10.001

    authors: Ward SR,Lieber RL

    更新日期:2005-11-01 00:00:00

  • Endothelial actin and cell stiffness is modulated by substrate stiffness in 2D and 3D.

    abstract::There is a growing appreciation of the profound effects that passive mechanical properties, especially the stiffness of the local environment, can have on cellular functions. Many experiments are conducted in a 2D geometry (i.e., cells grown on top of substrates of varying stiffness), which is a simplification of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.012

    authors: Byfield FJ,Reen RK,Shentu TP,Levitan I,Gooch KJ

    更新日期:2009-05-29 00:00:00

  • Nonlinear analysis of gait kinematics to track changes in oxygen consumption in prolonged load carriage walking: a pilot study.

    abstract::Linking human mechanical work to physiological work for the purpose of developing a model of physical fatigue is a complex problem that cannot be solved easily by conventional biomechanical analysis. The purpose of the study was to determine if two nonlinear analysis methods can address the fundamental issue of utiliz...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.011

    authors: Schiffman JM,Chelidze D,Adams A,Segala DB,Hasselquist L

    更新日期:2009-09-18 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • The influence of lower leg configurations on muscle force variability.

    abstract::The maintenance of steady contractions is required in many daily tasks. However, there is little understanding of how various lower limb configurations influence the ability to maintain force. The purpose of the current investigation was to examine the influence of joint angle on various lower-limb constant force cont...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.032

    authors: Ofori E,Shim J,Sosnoff JJ

    更新日期:2018-04-11 00:00:00

  • A mechanistic damage model for ligaments.

    abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.039

    authors: Barrett JM,Callaghan JP

    更新日期:2017-08-16 00:00:00

  • In-vivo analysis of sliding distance and cross-shear in Bi-cruciate retaining total knee arthroplasty.

    abstract::Polyethylene remains the most popular bearing material for total knee arthroplasty (TKA). Despite its widespread use, wear continue to be one of major factors implicated in revision surgery. Sliding distance, cross-shear, and contact stress are the major factors influencing polyethylene wear. As previous studies have ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.06.009

    authors: Arauz P,Peng Y,An S,Kwon YM

    更新日期:2018-08-22 00:00:00

  • Mechanical recovery of dentin following remineralization in vitro--an indentation study.

    abstract::This study sought to gain insights into the steps leading to remineralization and mechanical recovery of hydrated dentin. Mechanical recovery in water was hypothesized to result from effective mineral matrix binding and to occur from the innermost regions outwards due to an increase in the number of nucleation sites. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.005

    authors: Bertassoni LE,Habelitz S,Marshall SJ,Marshall GW

    更新日期:2011-01-04 00:00:00

  • Hip contact forces and gait patterns from routine activities.

    abstract::In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00040-9

    authors: Bergmann G,Deuretzbacher G,Heller M,Graichen F,Rohlmann A,Strauss J,Duda GN

    更新日期:2001-07-01 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Untangling biomechanical differences in perturbation-induced stepping strategies for lateral balance stability in older individuals.

    abstract::When recovering balance from a lateral perturbation, younger adults tend to stabilize balance with a single lateral sidestep while older adults often take multistep responses. Using multiple steps to recover balance is consistently associated with increased fall risk, altered body center of mass (CoM) control and inst...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110161

    authors: Borrelli J,Creath R,Gray VL,Rogers MW

    更新日期:2021-01-04 00:00:00

  • Functional muscle synergies constrain force production during postural tasks.

    abstract::We recently demonstrated that a set of five functional muscle synergies were sufficient to characterize both hindlimb muscle activity and active forces during automatic postural responses in cats standing at multiple postural configurations. This characterization depended critically upon the assumption that the endpoi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.012

    authors: McKay JL,Ting LH

    更新日期:2008-01-01 00:00:00

  • Sarcomere dynamics in skeletal muscle myofibrils during isometric contractions.

    abstract::The main goal of this study was to evaluate the dynamics of sarcomeres during isometric activation of skeletal muscle myofibrils. Rabbit psoas myofibrils (n=14) were attached between a pair of cantilevers for force measurements at one side and a rigid glass needle at the other side, and their images were used for meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.011

    authors: Pavlov I,Novinger R,Rassier DE

    更新日期:2009-12-11 00:00:00

  • The relationship between elastic properties and microstructure of bovine cortical bone.

    abstract::The relationship between the structure of bone on the microscopic level and its mechanical properties was investigated by comparing bovine cortical bone of two microstructural types. Measurements of elastic properties were made in three orthogonal directions on specimens of plexiform and Haversian bone, taken from the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90134-9

    authors: Lipson SF,Katz JL

    更新日期:1984-01-01 00:00:00

  • The flexural rigidity of the aortic valve leaflet in the commissural region.

    abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.026

    authors: Mirnajafi A,Raymer JM,McClure LR,Sacks MS

    更新日期:2006-01-01 00:00:00

  • The role of elastin and collagen in the softening behavior of the human thoracic aortic media.

    abstract::In a previous study we were able to accurately fit experimental data on arterial tissues at supra-physiological loads using a material model that accounts for softening/damage only in the portion of the model associated with the collagen fibers (Weisbecker et al., 2012). Naturally, this result leads to the hypothesis ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.025

    authors: Weisbecker H,Viertler C,Pierce DM,Holzapfel GA

    更新日期:2013-07-26 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • Do quadrupeds require a change in trunk posture to walk backward?

    abstract::Previous studies on cats walking backward have indicated that they adopt a presumably adaptive posture characterized by extreme dorsiflexion of the lumbar spine. Because humans do not show any marked postural changes during backward walking, we questioned whether the posture exhibited by cats during backward walking w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00071-3

    authors: Vilensky JA,Cook JA

    更新日期:2000-08-01 00:00:00

  • Realistic virtual intracranial stenting and computational fluid dynamics for treatment analysis.

    abstract::In order to support the decisions of medical experts and to develop better stent designs, the availability of a simulation tool for virtual stenting would be extremely useful. An innovative virtual stenting technique is described in this work, which is directly applicable for complex patient-specific geometries. A bas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.08.047

    authors: Janiga G,Rössl C,Skalej M,Thévenin D

    更新日期:2013-01-04 00:00:00

  • A dual optimization method for the material parameter identification of a biphasic poroviscoelastic hydrogel: Potential application to hypercompliant soft tissues.

    abstract::A dual-indentation creep and stress relaxation methodology was developed and validated for the material characterization of very soft biological tissue within the framework of the biphasic poroviscoelastic (BPVE) constitutive model. Agarose hydrogel, a generic porous medium with mobile fluid, served as a mechanical ti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.019

    authors: Olberding JE,Francis Suh JK

    更新日期:2006-01-01 00:00:00

  • Relations between compressive axial forces in an instrumented massive femoral implant, ground reaction forces, and integrated electromyographs from vastus lateralis during various 'osteogenic' exercises.

    abstract::A subject, who had undergone surgery to replace one hip joint and the proximal half of the femur with an instrumented titanium implant, performed brief exercises whilst simultaneous measurements were made of compressive axial force in the implant using short-range wireless telemetry, ground reactions using a Kistler f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00043-7

    authors: Bassey EJ,Littlewood JJ,Taylor SJ

    更新日期:1997-03-01 00:00:00

  • Compressive and shear hip joint contact forces are affected by pediatric obesity during walking.

    abstract::Obese children exhibit altered gait mechanics compared to healthy-weight children and have an increased prevalence of hip pain and pathology. This study sought to determine the relationships between body mass and compressive and shear hip joint contact forces during walking. Kinematic and kinetic data were collected d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.033

    authors: Lerner ZF,Browning RC

    更新日期:2016-06-14 00:00:00

  • Trunk stiffness and dynamics during active extension exertions.

    abstract::Spinal stability is related to the recruitment and control of active muscle stiffness. Stochastic system identification techniques were used to calculate the effective stiffness and dynamics of the trunk during active trunk extension exertions. Twenty-one healthy adult subjects (10 males, 11 females) wore a harness wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.09.014

    authors: Moorhouse KM,Granata KP

    更新日期:2005-10-01 00:00:00

  • Improved walking function in laboratory does not guarantee increased community walking in stroke survivors: Potential role of gait biomechanics.

    abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.011

    authors: Ardestani MM,Henderson CE,Hornby TG

    更新日期:2019-06-25 00:00:00

  • A new transducer system for direct motor unit force measurement.

    abstract::A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84545-3

    authors: Turkawski SJ,van Ruijven LJ,van Kuyen M,Schreurs AW,Weijs WA

    更新日期:1996-11-01 00:00:00

  • A new instrumentation system for training rowers.

    abstract::A dry-land rowing system was developed to provide the coach and/or athlete with quantitative information about the athlete's kinetics and kinematics while the athlete trains. This system consists of a Concept II rowing ergometer instrumented with a force transducer and potentiometer, four electrogoniometers attached t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00139-6

    authors: Hawkins D

    更新日期:2000-02-01 00:00:00