Hip contact forces and gait patterns from routine activities.

Abstract:

:In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous analyses of gait patterns and ground reaction forces were performed in four patients during the most frequent activities of daily living. From the individual data sets an average was calculated. The paper focuses on the loading of the femoral implant component but complete data are additionally stored on an associated compact disc. It contains complete gait and hip contact force data as well as calculated muscle activities during walking and stair climbing and the frequencies of daily activities observed in hip patients. The mechanical loading and function of the hip joint and proximal femur is thereby completely documented. The average patient loaded his hip joint with 238% BW (percent of body weight) when walking at about 4 km/h and with slightly less when standing on one leg. This is below the levels previously reported for two other patients (Bergmann et al., Clinical Biomechanics 26 (1993) 969-990). When climbing upstairs the joint contact force is 251% BW which is less than 260% BW when going downstairs. Inwards torsion of the implant is probably critical for the stem fixation. On average it is 23% larger when going upstairs than during normal level walking. The inter- and intra-individual variations during stair climbing are large and the highest torque values are 83% larger than during normal walking. Because the hip joint loading during all other common activities of most hip patients are comparably small (except during stumbling), implants should mainly be tested with loading conditions that mimic walking and stair climbing.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Bergmann G,Deuretzbacher G,Heller M,Graichen F,Rohlmann A,Strauss J,Duda GN

doi

10.1016/s0021-9290(01)00040-9

keywords:

subject

Has Abstract

pub_date

2001-07-01 00:00:00

pages

859-71

issue

7

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(01)00040-9

journal_volume

34

pub_type

杂志文章
  • Haemodynamic effects of incomplete stent apposition in curved coronary arteries.

    abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.016

    authors: Chen WX,Poon EKW,Thondapu V,Hutchins N,Barlis P,Ooi A

    更新日期:2017-10-03 00:00:00

  • Parametric and subject-specific finite element modelling of the lower cervical spine. Influence of geometrical parameters on the motion patterns.

    abstract::Morphometrical and postural features of the cervical spine are supposed to significantly influence its biomechanical behaviour. However, the effects of these geometrical parameters are quite difficult to evaluate. An original numerical method is proposed in order to automatically generate parametric and subject-specif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.04.007

    authors: Laville A,Laporte S,Skalli W

    更新日期:2009-07-22 00:00:00

  • Regressions for estimating muscle parameters in the thoracic and lumbar trunk for use in musculoskeletal modeling.

    abstract::Musculoskeletal modeling requires information on muscle parameters such as cross-sectional area (CSA) and moment arms. A variety of previous studies have reported muscle parameters in the trunk based on in vivo imaging, but there remain gaps in the available data as well as limitations in the generalizability of such ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.004

    authors: Anderson DE,D'Agostino JM,Bruno AG,Manoharan RK,Bouxsein ML

    更新日期:2012-01-03 00:00:00

  • Why does intermittent hydrostatic pressure enhance the mineralization process in fetal cartilage?

    abstract::The purpose of this study was to determine which factor is the most likely one to have stimulated the mineralization process in the in vitro experiments of Klein-Nulend et al. (Arth. Rheum., 29, 1002-1009, 1986), in which fetal cartilaginous metatarsals were externally loaded with an intermittent hydrostatic pressure,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00165-1

    authors: Tanck E,van Driel WD,Hagen JW,Burger EH,Blankevoort L,Huiskes R

    更新日期:1999-02-01 00:00:00

  • Relative contribution of the pressure variations under the feet and body weight distribution over both legs in the control of upright stance.

    abstract::The resultant centre of pressure (CP(Res)) trajectories are aimed at controlling body movements in upright stance. When standing on two legs, these trajectories are generated by exerting reaction forces under each foot and by loading-unloading mechanisms intervening at the hip level. To assess the respective contribut...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.003

    authors: Rougier PR

    更新日期:2007-01-01 00:00:00

  • Can fabric sensors monitor breast motion?

    abstract::To establish whether conducting polymer-coated fabric sensors could be used to monitor breast motion, vertical breast motion of two large breasted women (C+ bra cup) was simultaneously monitored using an OPTOTRAK 3020 motion analysis system (200 Hz) and polymer-coated fabric sensors linked to a custom-made Bluetooth t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.020

    authors: Campbell TE,Munro BJ,Wallace GG,Steele JR

    更新日期:2007-01-01 00:00:00

  • Sex differences in postures of the upper body during a simulated work task performed above shoulder level.

    abstract::The aim of this study was to evaluate if there are sex differences in postures of upper arm, upper back, head and neck after muscle fatigue induced by a simulated work task, requiring upper arm movements performed above shoulder level. Nineteen females and 18 males were evaluated. Upper arm elevation, upper back, head...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109855

    authors: Cid MM,Côté JN,Zancanaro LL,Oliveira AB

    更新日期:2020-06-23 00:00:00

  • The effects of -80 °C short-term storage on the mechanical response of tricuspid valve leaflets.

    abstract::Mechanical testing of soft tissues would ideally rely on using fresh specimens. In the event that fresh tissues are not readily available, alternative measures, such as storing fresh specimens at -80 °C, could be considered. Previous studies have shown that changes in the mechanical properties of the tissues due to fr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109462

    authors: Salinas SD,Clark MM,Amini R

    更新日期:2020-01-02 00:00:00

  • Membrane permeability during pressure ulcer formation: A computational model of dynamic competition between cytoskeletal damage and repair.

    abstract::Pressure ulcers are debilitating wounds that arise frequently in people who have lost mobility. Mechanical stress, oxidative stress and ischemia-reperfusion injury are potential sources of damage during pressure ulcer formation, but cross-talk between these sources has rarely been investigated. In vitro experiments wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.022

    authors: Jagannathan NS,Tucker-Kellogg L

    更新日期:2016-05-24 00:00:00

  • Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology.

    abstract::A truss structure was recently introduced as an interbody fusion cage. As a truss system, some of the connected elements may be in a state of compression and others in tension. This study aimed to quantify both the mean and variance of strut strains in such an implant when loaded in a simulated fusion condition with v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.051

    authors: Caffrey JP,Cory E,Wong VW,Masuda K,Chen AC,Hunt JP,Ganey TM,Sah RL

    更新日期:2016-12-08 00:00:00

  • An expression relating breaking stress and density of trabecular bone.

    abstract::Bone mineral density (BMD) is the principal diagnostic tool used in clinical settings to diagnose and monitor osteoporosis. Experimental studies on ex vivo bone samples from multiple skeletal locations have been used to propose that their breaking stress bears a power-law relationship to volumetric BMD, with a locatio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.001

    authors: Rajapakse CS,Thomsen JS,Espinoza Ortiz JS,Wimalawansa SJ,Ebbesen EN,Mosekilde L,Gunaratne GH

    更新日期:2004-08-01 00:00:00

  • An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle.

    abstract::Identification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.031

    authors: Chen WM,Phyau-Wui Shim V,Park SB,Lee T

    更新日期:2011-06-03 00:00:00

  • Novel isodamping dynamometer accurately measures plantar flexor function.

    abstract::Isokinetic dynamometers are the gold standard tools used to assess in vivo joint and muscle function in human subjects, however, the large size and high cost of these devices prevents their widespread use outside of traditonal biomechanics labs. In this study, we developed a mobile dynamometer to allow for field measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110015

    authors: Drazan JF,Hullfish TJ,Baxter JR

    更新日期:2020-10-09 00:00:00

  • What is the role of the convective current density in the real-time calcium response of cultured bone cells to fluid flow?

    abstract::Cultured cells subjected to fluid flow are exposed to mechanical forces and electrokinetic forces. The convective current establishes an electrokinetic force created by the flow-dependent transport of mobile ions in the media over the charged cell surfaces. This current can be expressed as a current density, the curre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84535-0

    authors: Hung CT,Allen FD,Pollack SR,Brighton CT

    更新日期:1996-11-01 00:00:00

  • Assessment of gait patterns using neural networks.

    abstract::A new approach for the assessment of gait patterns is presented. The use of neural network techniques for decision making in gait analysis is for some purposes more effective than biomechanical methods or conventional statistics. To demonstrate this, a neural network was trained to distinguish 'healthy' from 'patholog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90028-d

    authors: Holzreiter SH,Köhle ME

    更新日期:1993-06-01 00:00:00

  • Altered frontal and transverse plane tibiofemoral kinematics and patellofemoral malalignments during downhill gait in patients with mixed knee osteoarthritis.

    abstract::Patients with knee osteoarthritis often present with signs of mixed tibiofemoral and patellofemoral joint disease. It has been suggested that altered frontal and transverse plane knee joint mechanics play a key role in compartment-specific patterns of knee osteoarthritis, but in-vivo evidence in support of this premis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.015

    authors: Farrokhi S,Meholic B,Chuang WN,Gustafson JA,Fitzgerald GK,Tashman S

    更新日期:2015-07-16 00:00:00

  • Opto-mechanical characterization of sclera by polarization sensitive optical coherence tomography.

    abstract::Polarization sensitive optical coherence tomography (PSOCT) is an interferometric technique sensitive to birefringence. Since mechanical loading alters the orientation of birefringent collagen fibrils, we asked if PSOCT can be used to measure local mechanical properties of sclera. Infrared (1300 nm) PSOCT was performe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.017

    authors: Shin A,Park J,Demer JL

    更新日期:2018-04-27 00:00:00

  • Correlates between kinematics and baropodometric measurements for an integrated in-vivo assessment of the segmental foot function in gait.

    abstract::Baropodometry and multi-segmental foot kinematics are frequently employed to obtain insight into the mechanics of the foot-ground interaction in both basic research and clinical settings. However, nothing hitherto has been reported on the full integration of kinematics with baropodometric parameters, and only a few st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.014

    authors: Giacomozzi C,Leardini A,Caravaggi P

    更新日期:2014-08-22 00:00:00

  • Three-dimensional measurement of proximal radioulnar space during active forearm pronation.

    abstract::Distal biceps tendon ruptures have been reported to be associated with narrowing of the proximal radioulnar space. There have been no studies that three-dimensionally measured the distance between the bicipital tuberosity and the proximal ulna during active motion. The purpose of this study was to three-dimensionally ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110120

    authors: Matsuki K,Sugaya H,Takahashi N,Tokai M,Ueda Y,Hoshika S,Hamada H,Banks SA

    更新日期:2020-12-02 00:00:00

  • Towards the modelling of ageing and atherosclerosis effects in ApoE(-/-) mice aortic tissue.

    abstract::The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.043

    authors: Waffenschmidt T,Cilla M,Sáez P,Pérez MM,Martínez MA,Menzel A,Peña E

    更新日期:2016-08-16 00:00:00

  • Hysteresis measurements in intact human tendon.

    abstract::Mechanical hysteresis in tendons has traditionally been quantified from tensile testing of isolated specimens. Limitations associated with tendon displacement measurement and clamping, and uncertainties as to whether in vitro material represents intact tendon function necessitate measuring hysteresis under in vivo con...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00130-5

    authors: Maganaris CN,Paul JP

    更新日期:2000-12-01 00:00:00

  • Modeling aqueous humor collection from the human eye.

    abstract::Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.025

    authors: Kapnisis K,Doormaal MV,Ross Ethier C

    更新日期:2009-11-13 00:00:00

  • Simple method for measuring center of mass work during field running.

    abstract::The purpose of this study was to propose and validate a new simple method for calculation of center of mass work during field running, in order to avoid the use of costly and inconvenient measurement devices. This method relies on spring-mass model and measurements of average horizontal velocity, and contact and fligh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109369

    authors: Devise M,Rossi J,Théveniau N,Belli A

    更新日期:2019-12-03 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Principles of measurement of vertebral rotation from frontal projections of the pedicles.

    abstract::Measurement of vertebral rotation from frontal X-ray projections of the pedicles was introduced by Nash and Moe. By the introduction of a vertebral model, their method and different modifications can be described and characterized easily. A geometrical analysis shows, that two parameters are sufficient for this model....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90005-8

    authors: Drerup B

    更新日期:1984-01-01 00:00:00

  • Feedback control from the jaw joints during biting: an investigation of the reptile Sphenodon using multibody modelling.

    abstract::Sphenodon, a lizard-like reptile, is the only living representative of a group that was once widespread at the time of the dinosaurs. Unique jaw mechanics incorporate crushing and shearing motions to breakdown food, but during this process excessive loading could cause damage to the jaw joints and teeth. In mammals li...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.001

    authors: Curtis N,Jones ME,Evans SE,O'Higgins P,Fagan MJ

    更新日期:2010-12-01 00:00:00

  • On the importance of blood rheology for bulk flow in hemodynamic models of the carotid bifurcation.

    abstract::Here we present a study on the impact of assumptions on image-based hemodynamic simulations of healthy carotid bifurcations. In particular, we evaluate to which extent assumptions on blood rheology influence bulk flow features, driven by the fact that few studies have provided adequate insights into the influence of a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.028

    authors: Morbiducci U,Gallo D,Massai D,Ponzini R,Deriu MA,Antiga L,Redaelli A,Montevecchi FM

    更新日期:2011-09-02 00:00:00

  • Probing softness of the parietal pleural surface at the micron scale.

    abstract::The pleural surfaces of the chest wall and lung slide against each other, lubricated by pleural fluid. During sliding motion of soft tissues, shear induced hydrodynamic pressure deforms the surfaces, promoting uniformity of the fluid layer thickness, thereby reducing friction. To assess pleural deformability at length...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.008

    authors: Kim JH,Butler JP,Loring SH

    更新日期:2011-09-23 00:00:00

  • Combining muscle synergies and biomechanical analysis to assess gait in stroke patients.

    abstract::The understanding of biomechanical deficits and impaired neural control of gait after stroke is crucial to prescribe effective customized treatments aimed at improving walking function. Instrumented gait analysis has been increasingly integrated into the clinical practice to enhance precision and inter-rater reliabili...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.08.006

    authors: Barroso FO,Torricelli D,Molina-Rueda F,Alguacil-Diego IM,Cano-de-la-Cuerda R,Santos C,Moreno JC,Miangolarra-Page JC,Pons JL

    更新日期:2017-10-03 00:00:00

  • Marker-less versus marker-based driven musculoskeletal models of the spine during static load-handling activities.

    abstract::Evaluation of workers' body posture in workstations is a prerequisite to estimate spinal loads and assess risk of injury for the subsequent design of preventive interventions. The Microsoft Kinect™ sensor is, in this regard, advantageous over the traditional skin-marker-based optical motion capture systems for being m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110043

    authors: Asadi F,Arjmand N

    更新日期:2020-11-09 00:00:00