Abstract:
:Mechanical hysteresis in tendons has traditionally been quantified from tensile testing of isolated specimens. Limitations associated with tendon displacement measurement and clamping, and uncertainties as to whether in vitro material represents intact tendon function necessitate measuring hysteresis under in vivo conditions. In the present study such measurements were taken in the human tibialis anterior (TA) tendon. Having the foot fixed on a dynamometer footplate, the displacement of the TA tendon during stimulation and relaxation of the TA muscle was recorded by means of ultrasonography in six men. Combining moment data corresponding to 0, 20, 40, 60, 80 and 100% of maximum voltage moment and the respective tendon-displacement data, a hysteresis loop was obtained between the load-displacement curves during contraction and relaxation. Measurement of the hysteresis loop area yielded a value of 19%. This value agrees with results from in vitro tensile tests of low-stress tendons, suitable for tensile force transmission and joint displacement control. In fact, the human TA tendon has such functional characteristics. The methodology presented allows design of longitudinal and cross-sectional experimental protocols, and in vivo assessment of tendon function and propensity to overheat.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Maganaris CN,Paul JPdoi
10.1016/s0021-9290(00)00130-5keywords:
subject
Has Abstractpub_date
2000-12-01 00:00:00pages
1723-7issue
12eissn
0021-9290issn
1873-2380pii
S0021-9290(00)00130-5journal_volume
33pub_type
杂志文章abstract::This study aimed to compare the muscle activities of the lower limb during overground level running (LR) and uphill running (UR) by using a musculoskeletal model. Six male distance runners ran at three running speeds (slow: 3.3 m/s; medium: 4.2 m/s; and high: 5.0 m/s) on a level runway and a slope of 9.1% grade in whi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.028
更新日期:2007-01-01 00:00:00
abstract::Three recent studies reveal that the unloaded length of a carotid artery increases significantly and rapidly in response to sustained increases in axial extension. Moreover, such lengthening involves an "unprecedented" increase in the rate of turnover of cells and matrix. Although current data are not sufficient for d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.06.017
更新日期:2005-06-01 00:00:00
abstract::We investigated the microstructural basis of a reduced stress concentration around the primary nutrient foramen of the equine third metacarpus. We quantified the spatial variations of compositional parameters (mineral content, volume fraction, histological architecture, and osteonal trajectories) from microradiographs...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00130-1
更新日期:2003-10-01 00:00:00
abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.04.033
更新日期:2019-05-24 00:00:00
abstract::Mechanical adaptions of cells, including stiffness variation, cytoskeleton remodeling, motion coordination, and shape changing, are essential for tissue morphogenesis, wound healing, and malignant progression. In this paper, we take confluent monolayers of Madin-Darby canine kidney (MDCK) and mouse myoblast (C2C12) ce...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109763
更新日期:2020-05-07 00:00:00
abstract::Static stretching is a major type of mechanical stimuli utilized during distraction osteogenesis (DO), a general surgical method for the lengthening of bone. The molecular signals that drive the regenerative process in DO include a variety of cytokines. Among these, bone morphogenic protein (BMP, -2 and -4) has been r...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.08.006
更新日期:2009-12-11 00:00:00
abstract::Long-term clinical follow-up studies have shown that radiolucent lines at the cement interfaces of total hip replacement femoral components develop gradually, ultimately leading to loosening. In this experimental study, 32 synthetic femurs implanted with cemented femoral components were cyclically loaded with a dynami...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.006
更新日期:2011-01-11 00:00:00
abstract::Head injury is a persistent and costly problem for both children and adults. Globally, approximately 10 million people are hospitalized each year for head injuries. Knowing the structural properties of the head is important for modeling the response of the head in impact, and for providing insights into mechanisms of ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.024
更新日期:2015-11-05 00:00:00
abstract::In the present study, the electro-mechanical properties of human knee articular cartilage were measured in vitro. An arthroscopic measurement tool was used to measure streaming potential integral (SPI), after which creep indentation tests were performed. Additionally, degradation level of the tissue was determined in ...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2013.02.004
更新日期:2013-04-26 00:00:00
abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.004
更新日期:2007-01-01 00:00:00
abstract::Stiff-knee gait is characterized by diminished and delayed knee flexion during swing. Rectus femoris transfer surgery, a common treatment for stiff-knee gait, is often recommended when a patient exhibits prolonged activity of the rectus femoris muscle during swing. Treatment outcomes are inconsistent, in part, due to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.05.030
更新日期:2008-08-07 00:00:00
abstract::This work describes a dynamic model of the low back that incorporates extensive anatomical detail of the musculo-ligamentous-skeletal system to predict the load time histories of individual tissues. The dynamic reaction moment about L4/L5 was determined during lateral bending from a linked-segment model. This reaction...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90259-4
更新日期:1992-04-01 00:00:00
abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.035
更新日期:2017-01-04 00:00:00
abstract::In posturographic recordings, the center of pressure (COP) displacement does not accurately reflect migration of the gravity line (GL), the vertical line passing through the body's center of gravity, COG. Since the horizontal ground reaction force, Fx, is proportional to the horizontal acceleration of the COG its seco...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)00116-4
更新日期:1998-02-01 00:00:00
abstract::The compressive properties of skeletal muscle are important in impact biomechanics, rehabilitation engineering and surgical simulation. However, the mechanical behaviour of muscle tissue in compression remains poorly characterised. In this paper, the time-dependent properties of passive skeletal muscle were investigat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.02.007
更新日期:2008-01-01 00:00:00
abstract::Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during loco...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.07.025
更新日期:2007-01-01 00:00:00
abstract::Posteroanterior spinal stiffness assessments are common in the evaluating patients with low back pain. The purpose of this study was to determine the effects of mechanical excitation frequency on dynamic lumbar spine stiffness. A computer-controlled voice coil actuator equipped with a load cell and LVDT was used to de...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.037
更新日期:2007-01-01 00:00:00
abstract::Understanding the mechanical behaviour of arterial tissue is vital to the development and analysis of medical devices targeting diseased vessels. During angioplasty and stenting, stress softening and permanent deformation of the vessel wall occur during implantation of the device, however little data exists on the ine...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.02.026
更新日期:2012-05-11 00:00:00
abstract::A novel technique to measure in vitro disc pressures in human cervical spine specimens was developed. A miniature pressure transducer was used and an insertion technique was designed to minimise artefacts due to insertion. The technique was used to measure the intradiscal pressure in cervical spines loaded in pure axi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00205-0
更新日期:2001-04-01 00:00:00
abstract::The measurement of relative motion between two moving bones is commonly accomplished for in vitro studies by attaching to each bone a series of either passive or active markers in a fixed orientation to create a rigid body (RB). This work determined the accuracy of motion between two RBs using an Optotrak optical moti...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.01.017
更新日期:2007-01-01 00:00:00
abstract::Many clinical studies suggest that local blood flow patterns are involved in the location and development of atherosclerosis. In coronary diseases, this assumption should be corroborated by quantitative information on local hemodynamic parameters such as pressure, velocity or wall shear stress. Nowadays, computational...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00179-3
更新日期:2002-10-01 00:00:00
abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.04.009
更新日期:2018-06-06 00:00:00
abstract::The aim of this work is to specify which model of turbulence is the most adapted in order to predict the drag forces that a swimmer encounters during his movement in the fluid environment. For this, a Computational Fluid Dynamics (CFD) analysis has been undertaken with a commercial CFD code (Fluent). The problem was m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.010
更新日期:2010-02-10 00:00:00
abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90049-3
更新日期:1994-11-01 00:00:00
abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00192-x
更新日期:2000-03-01 00:00:00
abstract::Pre-clinical tests are often performed to screen new implant designs, surgical techniques, and cement formulations. In this work, we developed a technique to simulate the cement-bone morphology found with postmortem retrieved cemented hip replacements. With this technique, a soy wax barrier is created along the endost...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.029
更新日期:2010-10-19 00:00:00
abstract::The mechanisms by which mechanical loading may alter bone development within growth plates are still poorly understood. However, several growth plate cell or tissue morphological parameters are associated with both normal and mechanically modulated bone growth rates. The aim of this study was to quantify in situ the t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.05.010
更新日期:2010-09-17 00:00:00
abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.010
更新日期:2018-02-08 00:00:00
abstract::In this study, we proposed a novel approach to assess the energy dissipation during the post-yield deformation of bone. Based on the stress-strain behavior in an incremental and cyclic loading-unloading-reloading scheme in uniaxial tension, we partitioned the post-yield energy dissipation of bone into three distinct p...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.02.002
更新日期:2007-01-01 00:00:00
abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90068-7
更新日期:1989-01-01 00:00:00