Site specific inelasticity of arterial tissue.

Abstract:

:Understanding the mechanical behaviour of arterial tissue is vital to the development and analysis of medical devices targeting diseased vessels. During angioplasty and stenting, stress softening and permanent deformation of the vessel wall occur during implantation of the device, however little data exists on the inelastic behaviour of cardiovascular tissue and how this varies through the arterial tree. The aim of this study was to characterise the magnitude of stress softening and inelastic deformations due to loading throughout the arterial tree and to investigate the anisotropic inelastic behaviour of the tissue. Cyclic compression tests were used to investigate the differences in inelastic behaviour for carotid, aorta, femoral and coronary arteries harvested from 3-4 month old female pigs, while the anisotropic behaviour of aortic and carotid tissue was determined using cyclic tensile tests in the longitudinal and circumferential directions. The differences in inelastic behaviour were correlated to the ratio of collagen to elastin content of the arteries. It was found that larger inelastic deformations occurred in muscular arteries (coronary), which had a higher collagen to elastin ratio than elastic arteries (aorta), where the smallest inelastic deformations were observed. Lower magnitude inelastic deformations were observed in the circumferential tensile direction than in the longitudinal tensile direction or due to radial compression. This may be as a result of non-collagenous components in the artery becoming more easily damaged than the collagen fibres during loading. Stress softening was also found to be dependent on artery type. In the future, computational models should consider such site dependant, anisotropic inelastic behaviour in order to better predict the outcomes of interventional procedures such as angioplasty and stenting.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Maher E,Early M,Creane A,Lally C,Kelly DJ

doi

10.1016/j.jbiomech.2012.02.026

subject

Has Abstract

pub_date

2012-05-11 00:00:00

pages

1393-9

issue

8

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(12)00149-2

journal_volume

45

pub_type

杂志文章
  • Using directional statistics to test hypotheses regarding rigid body attitude: Comparison to univariate and multivariate Cardan angle tests.

    abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109976

    authors: Pataky TC,Challis JH

    更新日期:2020-10-09 00:00:00

  • A 3D skeletal muscle model coupled with active contraction of muscle fibres and hyperelastic behaviour.

    abstract::This paper presents a three-dimensional finite element model of skeletal muscle which was developed to simulate active and passive non-linear mechanical behaviours of the muscle during lengthening or shortening under either quasi-static or dynamic condition. Constitutive relation of the muscle was determined by using ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.021

    authors: Tang CY,Zhang G,Tsui CP

    更新日期:2009-05-11 00:00:00

  • Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

    abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.021

    authors: Lundberg HJ,Pedersen DR,Baer TE,Muste M,Callaghan JJ,Brown TD

    更新日期:2007-01-01 00:00:00

  • Effects of aging on hip abductor-adductor neuromuscular and mechanical performance during the weight transfer phase of lateral protective stepping.

    abstract::Aging brings about challenges in the ability to recover balance through protective stepping, especially in the lateral direction. Previous work has suggested that lateral protective stepping during weight transfer may be affected by impaired muscle composition and performance of the hip abductors (AB) in older adults....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.040

    authors: Inacio M,Creath R,Rogers MW

    更新日期:2019-01-03 00:00:00

  • Knee kinematics and kinetics during shuttle run cutting: comparison of the assessments performed with and without the point cluster technique.

    abstract::The differences between the assessments performed with and without the point cluster technique (PCT) for knee joint motions during the high-risk movements associated with non-contact anterior cruciate ligament (ACL) injuries have not been reported. This study aims to examine the differences between PCT and non-PCT ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.05.001

    authors: Ishii H,Nagano Y,Ida H,Fukubayashi T,Maruyama T

    更新日期:2011-07-07 00:00:00

  • Influence of microcalcifications on vulnerable plaque mechanics using FSI modeling.

    abstract::Sudden heart attacks remain one of the primary causes of premature death in the developed world. Asymptomatic vulnerable plaques that rupture are believed to prompt such fatal heart attacks and strokes. The role of microcalcifications in the vulnerable plaque rupture mechanics is still debated. Recent studies suggest ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.029

    authors: Bluestein D,Alemu Y,Avrahami I,Gharib M,Dumont K,Ricotta JJ,Einav S

    更新日期:2008-01-01 00:00:00

  • Quantifying translations in the radiohumeral joint: application of a floating axis analysis.

    abstract::The purpose of this study was to apply the Floating Axis analysis technique to the elbow joint, and to verify its ability to quantify clinically relevant radiohumeral translation in vitro using an electromagnetic tracking device. Of particular interest was the ability to quantify changes in anterior-posterior radial h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00103-9

    authors: Dunning CE,Duck TR,King GJ,Johnson JA

    更新日期:2003-08-01 00:00:00

  • Numerical errors and uncertainties in finite-element modeling of trabecular bone.

    abstract::Although micromechanical finite-element models are being increasingly used to help interpret the results of bio-mechanical tests, there has not yet been a systematic study of the numerical errors and uncertainties that occur with these methods. In this work, finite-element models of human L1 vertebra have been used to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00108-0

    authors: Ladd AJ,Kinney JH

    更新日期:1998-10-01 00:00:00

  • Kinematic adjustability of unilateral external fixators for fracture reduction and alignment of axial dynamization.

    abstract::Bone fracture reduction and bone axial dynamization are important operations which effectiveness can be further enhanced by the use of a unilateral external fixator. By design, axial dynamization can be performed through reciprocating one of its translational joints. However, non-axial dynamization may occur after cor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.002

    authors: Ou YJ

    更新日期:2009-08-25 00:00:00

  • Associations of hamstring and triceps surae muscle spasticity and stance phase gait kinematics in children with spastic diplegic cerebral palsy.

    abstract::Clinical decisions on interventions to improve function in children with cerebral palsy (CP) are based, in part, on hypothesized interactions amongst physical signs of CP and functional deficits. However, a knowledge gap exists regarding associations between spasticity and gait function. This study quantified associat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110218

    authors: Bowal N,Nettel-Aguirre A,Ursulak G,Condliffe E,Robu I,Goldstein S,Emery C,Ronsky JL,Kuntze G

    更新日期:2021-01-16 00:00:00

  • Lumbar loads and trunk kinematics in people with a transtibial amputation during sit-to-stand.

    abstract::People with a transtibial amputation have numerous secondary health conditions, including an increased prevalence of low back pain. This increased prevalence may be partially explained by altered low back biomechanics during movement. The purpose of this study was to compare trunk kinematics and L4-L5 lumbar loads in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.030

    authors: Actis JA,Nolasco LA,Gates DH,Silverman AK

    更新日期:2018-03-01 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • Analysis of thoracic aorta hemodynamics using 3D particle tracking velocimetry and computational fluid dynamics.

    abstract::Parallel to the massive use of image-based computational hemodynamics to study the complex flow establishing in the human aorta, the need for suitable experimental techniques and ad hoc cases for the validation and benchmarking of numerical codes has grown more and more. Here we present a study where the 3D pulsatile ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.017

    authors: Gallo D,Gülan U,Di Stefano A,Ponzini R,Lüthi B,Holzner M,Morbiducci U

    更新日期:2014-09-22 00:00:00

  • Physical properties of cross-linked polyethylene foam (Plastazote) under clinical conditions.

    abstract::Cross-linked polyethylene foam (Plastazote) has been used in the management of painful foot disorders occurring in a number of disease processes. A series of mechanical tests have been performed under varying clinically encountered conditions to show a relationship between the deformation of the material and the load ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90101-5

    authors: Minns RJ,Craxford AD

    更新日期:1984-01-01 00:00:00

  • Comparison of partial least squares regression and principal component regression for pelvic shape prediction.

    abstract::This paper studied two different regression techniques for pelvic shape prediction, i.e., the partial least square regression (PLSR) and the principal component regression (PCR). Three different predictors such as surface landmarks, morphological parameters, or surface models of neighboring structures were used in a c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.005

    authors: Schumann S,Nolte LP,Zheng G

    更新日期:2013-01-04 00:00:00

  • Flow behaviour in an asymmetric compliant experimental model for abdominal aortic aneurysm.

    abstract::An experimental study was carried out on asymmetrical abdominal aortic aneurysm (AAA) to analyse the physiological flows involved. Velocity measurements were performed using particle image velocimetry. Resting and exercise flow rates were investigated in models with rigid and compliant walls to assess the parameters a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.017

    authors: Deplano V,Knapp Y,Bertrand E,Gaillard E

    更新日期:2007-01-01 00:00:00

  • Microcrack growth parameters for compact bone deduced from stiffness variations.

    abstract::This paper shows how information on the fatigue behaviour of microcracks can be obtained by the analysis of stiffness changes measured during cyclic loading. Relationships between crack length, growth rate and cyclic stress intensity were deduced, and compared with previous empirical equations. Results show that the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00050-5

    authors: Taylor D

    更新日期:1998-07-01 00:00:00

  • In-vivo analysis of thoracic mechanical response under belt loading: the role of body mass index in thorax stiffness.

    abstract::Thoracic injuries are a major cause of mortality in frontal collisions, especially for elderly and obese people. Car occupant individual characteristics like BMI are known to influence human vulnerability in crashes. In the present study, thoracic mechanical response of volunteers quantified by optical method was link...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.12.021

    authors: Poulard D,Bermond F,Compigne S,Bruyère K

    更新日期:2013-03-15 00:00:00

  • Comparison of shear forces and ligament loading in the healthy and ACL-deficient knee during gait.

    abstract::The purpose of this study was to predict and explain the pattern of shear force and ligament loading in the ACL-deficient knee during walking, and to compare these results to similar calculations for the healthy knee. Musculoskeletal modeling and computer simulation were combined to calculate ligament forces in the AC...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.07.001

    authors: Shelburne KB,Pandy MG,Torry MR

    更新日期:2004-03-01 00:00:00

  • Motor unit acceleration maps and interference mechanomyographic distribution.

    abstract::The study analyses the two-dimensional distribution of surface mechanomyographic (MMG) signal generated by the activation of single motor units located in three transverse positions in the tibialis anterior muscle. In 12 healthy volunteers, surface MMG signals were recorded from the tibialis anterior muscle with a 3 x...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.007

    authors: Farina D,Li X,Madeleine P

    更新日期:2008-09-18 00:00:00

  • Large deforming buoyant embolus passing through a stenotic common carotid artery: a computational simulation.

    abstract::Arterial embolism is responsible for the death of lots of people who suffers from heart diseases. The major risk of embolism in upper limbs is that the ruptured particles are brought into the brain, thus stimulating neurological symptoms or causing the stroke. We presented a computational model using fluid-structure i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.01.020

    authors: Vahidi B,Fatouraee N

    更新日期:2012-04-30 00:00:00

  • The selection of a standard convention for analyzing gait data based on the analysis of relevant biomechanical factors.

    abstract::The gait cycle is usually analyzed using one of two conventions: heel contact initiates the cycle and stance is followed by swing phases or toe-off initiates the cycle and swing then stance phases are analyzed. The purpose of the study is to demonstrate that based on a consideration of relevant biomechanical measures,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90025-6

    authors: DeVita P

    更新日期:1994-04-01 00:00:00

  • Numerical simulation of steady flow fields in a model of abdominal aorta with its peripheral branches.

    abstract::In the present study, a numerical calculation procedure based on a finite volume method was developed to simulate steady flow fields in a model of abdominal aorta with its peripheral branches. The study focused on the steady baseline flow fields and the wall shear stress (WSS) distribution as well as the localization ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00044-1

    authors: Lee D,Chen JY

    更新日期:2002-08-01 00:00:00

  • Crushed bone grafts and a collagen membrane are not suitable for enhancing cartilage quality in the regeneration of osteochondral defects--an in vivo study in sheep.

    abstract::Hyaline joint cartilage has only a limited potential for self-repair. Some of the published techniques for osteochondral defect therapy try to improve that potential. In this study, it was hypothesised that one of those surgical techniques, the crushed transplanted bone graft together with a collagen membrane, acceler...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.021

    authors: Schell H,Lienau J,Kleemann RU,Schlichting K,Taylor WR,Weiler A,Duda GN

    更新日期:2007-01-01 00:00:00

  • Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?

    abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.030

    authors: Ab-Lazid R,Perilli E,Ryan MK,Costi JJ,Reynolds KJ

    更新日期:2014-01-22 00:00:00

  • A mechanistic damage model for ligaments.

    abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.039

    authors: Barrett JM,Callaghan JP

    更新日期:2017-08-16 00:00:00

  • Simulating contact using the elastic foundation algorithm in OpenSim.

    abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.025

    authors: Hast MW,Hanson BG,Baxter JR

    更新日期:2019-01-03 00:00:00

  • A new technique to study the mechanical properties of collagen lattices.

    abstract::A new technique to study the mechanical properties of collagen lattices or dermal equivalents is described. With the help of the load-extension curve obtained with a uniaxial traction apparatus, a stiffness modulus varying from 0.06 to 1 MPa is calculated from the studied parameters (duration of culture, collagen and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90250-5

    authors: Chapuis JF,Agache P

    更新日期:1992-01-01 00:00:00

  • Formation and travel of vortices in model ventricles: application to the design of skeletal muscle ventricles.

    abstract::Vortex-ring production was studied in axisymmetric elastomeric ventricles designed to stimulate flow in a cardiovascular assist device. A flow visualization technique was used to investigate the effects of reducing the inlet diameter and predilating the ventricle on vortex travel in two ventricles of different shape a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00065-8

    authors: Shortland AP,Black RA,Jarvis JC,Henry FS,Iudicello F,Collins MW,Salmons S

    更新日期:1996-04-01 00:00:00

  • On the fibre composite material models of disc annulus--comparison of predicted stresses.

    abstract::An axisymmetric finite element model of a body-disc-body unit has been developed and used to study the relative effects of two distinct direction-dependent material representations of the disc annulus on the predicted state of stresses in the disc. The annulus fibrosus is modelled either as nonhomogeneous fibre reinfo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90050-x

    authors: Shirazi-Adl A

    更新日期:1989-01-01 00:00:00