Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

Abstract:

:Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Lundberg HJ,Pedersen DR,Baer TE,Muste M,Callaghan JJ,Brown TD

doi

10.1016/j.jbiomech.2007.01.021

subject

Has Abstract

pub_date

2007-01-01 00:00:00

pages

1676-85

issue

8

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(07)00073-5

journal_volume

40

pub_type

杂志文章
  • Mechanical adaptions of collective cells nearby free tissue boundaries.

    abstract::Mechanical adaptions of cells, including stiffness variation, cytoskeleton remodeling, motion coordination, and shape changing, are essential for tissue morphogenesis, wound healing, and malignant progression. In this paper, we take confluent monolayers of Madin-Darby canine kidney (MDCK) and mouse myoblast (C2C12) ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109763

    authors: Lv JQ,Chen PC,Góźdź WT,Li B

    更新日期:2020-05-07 00:00:00

  • Characterising skeletal muscle under large strain using eccentric and Fourier Transform-rheology.

    abstract::Characterising the passive anisotropic properties of soft tissues has been largely limited to the linear viscoelastic regime and shear loading is rarely done in the large deformation regime, despite the physiological significance of such properties. This paper demonstrates the use of eccentric rheology, which allows t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.08.025

    authors: Tan K,Cheng S,Jugé L,Bilston LE

    更新日期:2015-11-05 00:00:00

  • Human pendulum approach to simulate and quantify locomotor impact loading.

    abstract::The understanding of impact mechanics during locomotion is important for research within the fields of injury prevention and footwear design. Instrumented missiles offer a worthy solution to the lack of control inherent in in vivo activities and to the isolated nature of tissue studies. However, missiles cannot mimic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00002-y

    authors: Lafortune MA,Lake MJ

    更新日期:1995-09-01 00:00:00

  • Age-associated changes in the mechanical properties of human cadaveric pelvic floor muscles.

    abstract::Proper function of the female pelvic floor requires intact pelvic floor muscles (PFMs). The prevalence of pelvic floor disorders (PFDs) increases substantially with age, in part due to clinically identified deterioration of PFM function with age. However, the etiology of this decline remains largely unknown. We previo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109436

    authors: Burnett LA,Cook M,Shah S,Michelle Wong M,Kado DM,Alperin M

    更新日期:2020-01-02 00:00:00

  • Water in hydroxyapatite nanopores: Possible implications for interstitial bone fluid flow.

    abstract::The role of bone water in the activity of this organ is essential in structuring apatite crystals, providing pathways for nutrients and waste involved in the metabolism of bone cells and participating in bone remodelling mechanotransduction. It is commonly accepted that bone presents three levels of porosity, namely t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.025

    authors: Lemaire T,Pham TT,Capiez-Lernout E,de Leeuw NH,Naili S

    更新日期:2015-09-18 00:00:00

  • Biomechanists can revolutionize the STEM pipeline by engaging youth athletes in sports-science based STEM outreach.

    abstract::Increasing diversity in the STEM (Science, Technology, Engineering, and Math) fields has become imperative to ensure equitable access to economic opportunity and to provide the technologically adept workforce of the future. The present STEM pipeline preferentially engages youth who are, not only aware of and intereste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109511

    authors: Drazan JF

    更新日期:2020-01-23 00:00:00

  • Mechanical mechanisms of thrombosis in intact bent microvessels of rat mesentery.

    abstract::The hypothesis that thrombus can be induced by localized shear stresses/rates, such as in the bent/stretched microvessels, was tested both experimentally and computationally. Our newly designed in vivo experiments were performed on the microvessels (post-capillary venules, 20-50 microm diameter) of rat mesentery. Thes...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.013

    authors: Liu Q,Mirc D,Fu BM

    更新日期:2008-08-28 00:00:00

  • The role of synovial fluid filtration by cartilage in lubrication of synovial joints--II. Squeeze-film lubrication: homogeneous filtration.

    abstract::A mathematical model of synovial film filtration and synovial gel formation at normal approach of cartilage surfaces in the human hip joint is presented. The biphasic mixture model presented in Part I of this paper [Hlavácek, J. Biomechanics 26, (1993)] for synovial fluid and that of Mow and his collaborators [J. Biom...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90063-k

    authors: Hlavácek M

    更新日期:1993-10-01 00:00:00

  • Monitoring of fracture healing by lateral and axial vibration analysis.

    abstract::The ability to monitor the healing of bone fractures is crucially important in their treatment. The aim of the present study was to develop and validate an objective method for monitoring fracture healing based on bone vibrational response. An analytic model was formulated, with which the mechanical parameters at the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90060-g

    authors: Nikiforidis G,Bezerianos A,Dimarogonas A,Sutherland C

    更新日期:1990-01-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Non-linear viscoelastic models predict fingertip pulp force-displacement characteristics during voluntary tapping.

    abstract::We evaluated whether lumped-parameter non-linear viscoelastic models of human fingertip tissue can describe fingertip force-displacement characteristics during a range of rapid, dynamic tapping tasks. Eight human subjects tapped with their index finger on the surface of a rigid load cell while an optical system tracke...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00438-4

    authors: Jindrich DL,Zhou Y,Becker T,Dennerlein JT

    更新日期:2003-04-01 00:00:00

  • An experimental setup for the measurement of forces on a human cadaveric foot during inversion.

    abstract::An experimental setup was developed for statically measuring seven vertical and three horizontal reaction forces on the foot. In the setup, the leg can be simultaneously loaded (1) by a vertical force, (2) by an externally applied axial moment, and (3) by simulated muscle forces. The foot is free to invert under influ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90080-8

    authors: Ottevanger EJ,Spoor CW,van Leeuwen JL,Sauren AA,Janssen JD,Huson A

    更新日期:1989-01-01 00:00:00

  • On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method.

    abstract::In recent years, computational structural analyses have emerged as important tools to investigate the mechanical response of stent placement into arterial walls. Although most coronary stents are expanded by inflating a polymeric balloon, realistic computational balloon models have been introduced only recently. In th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.027

    authors: Gervaso F,Capelli C,Petrini L,Lattanzio S,Di Virgilio L,Migliavacca F

    更新日期:2008-01-01 00:00:00

  • Mechanical and geometrical properties of the rat semimembranosus lateralis muscle during isometric contractions.

    abstract::The orientation of the line of pull and geometrical characteristics of rat semimembranosus lateralis muscle (SM1) were measured in a plane during isometric contractions at different muscle lengths. The orientation of the line of pull was always similar in our plane of analysis. It was always aligned with the external ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90051-5

    authors: Willems ME,Huijing PA

    更新日期:1994-09-01 00:00:00

  • Fabric and elastic principal directions of cancellous bone are closely related.

    abstract::Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00177-7

    authors: Odgaard A,Kabel J,van Rietbergen B,Dalstra M,Huiskes R

    更新日期:1997-05-01 00:00:00

  • A numerical method for simulating the dynamics of human walking.

    abstract::This paper presents a general method for simulating the movement of the lower extremity during human walking. It is based upon two separate algorithms: one for single support (an open kinematic chain), and the other for the double support phase (a closed-loop linkage). Central to each of these is the recursive Newton-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90250-3

    authors: Pandy MG,Berme N

    更新日期:1988-01-01 00:00:00

  • Application of singular spectrum analysis to the smoothing of raw kinematic signals.

    abstract::Motion capture systems currently used in biomechanical analysis introduce systematic measurement errors that appear in the form of noise in recorded displacement signals. The noise is unacceptably amplified when differentiating displacements to obtain velocities and accelerations. To avoid this phenomenon, it is neces...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.031

    authors: Alonso FJ,Castillo JM,Pintado P

    更新日期:2005-05-01 00:00:00

  • T2 relaxation time measurements in tibiotalar cartilage after barefoot running and its relationship to ankle biomechanics.

    abstract::The influence of ankle kinematics and plantar pressure from mid-range barefoot running on T2 relaxation times of tibiotalar cartilage is unknown. This study aimed to quantitatively evaluate the T2 relaxation time of tibiotalar cartilage and ankle biomechanics following 5 km barefoot running. Twenty healthy runners (wh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.046

    authors: Kyung Kim H,Fernandez J,Logan C,Tarr GP,Doyle A,Mirjalili SA

    更新日期:2019-06-11 00:00:00

  • Reducing upper airway collapse at lower continuous positive airway titration pressure.

    abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.005

    authors: Ashaat S,Al-Jumaily AM

    更新日期:2016-12-08 00:00:00

  • Relationship between streaming potential and compressive stress in bovine intervertebral tissue.

    abstract::The intervertebral disc is formed by the nucleus pulposus (NP) and annulus fibrosus (AF), and intervertebral tissue contains a large amount of negatively charged proteoglycan. When this tissue becomes deformed, a streaming potential is induced by liquid flow with positive ions. The anisotropic property of the AF tissu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.06.018

    authors: Fujisaki K,Tadano S,Asano N

    更新日期:2011-09-02 00:00:00

  • Nonlinear finite element simulation to elucidate the efficacy of slit arteriotomy for end-to-side arterial anastomosis in microsurgery.

    abstract::The slit arteriotomy for end-to-side arterial microanastomosis is a technique used to revascularize free flaps in reconstructive surgery. Does a slit open to a width sufficient for blood supply? How is the slit opening affected by factors, such as arterial wall thickness and material stiffness? To answer these questio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.12.015

    authors: Gu H,Chua A,Tan BK,Chew Hung K

    更新日期:2006-01-01 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Optimal design parameters of the bicycle-rider system for maximal muscle power output.

    abstract::The purpose of this study was to find the optimal values of design parameters for a bicycle-rider system (crank length, pelvic inclination, seat height, and rate of crank rotation) which maximize the power output from muscles of the human lower limb during bicycling. The human lower limb was modelled as a planar syste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90322-t

    authors: Yoshihuku Y,Herzog W

    更新日期:1990-01-01 00:00:00

  • Prior storage conditions and loading rate affect the in vitro fracture response of spinal segments under impact loading.

    abstract::Traumatic injuries of the spine are mostly the consequence of rapid overload e.g. impact loading. In vitro investigations on this topic usually encompass biomechanical testing using frozen/thawed specimens and employ quasi-static loading conditions. It is generally accepted that a freezing/thawing cycle does not alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.011

    authors: Dudli S,Haschtmann D,Ferguson SJ

    更新日期:2011-09-02 00:00:00

  • Ligament fibre recruitment at the human ankle joint complex in passive flexion.

    abstract::Knowledge of ligament fibre recruitment at the human ankle joint complex is a fundamental prerequisite for analysing mobility and stability. Previous experimental and modelling studies have shown that ankle motion must be guided by fibres within the calcaneofibular and tibiocalcaneal ligaments, which remain approximat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.043

    authors: Stagni R,Leardini A,Ensini A

    更新日期:2004-12-01 00:00:00

  • Effects of lumbo-pelvic rhythm on trunk muscle forces and disc loads during forward flexion: A combined musculoskeletal and finite element simulation study.

    abstract::Previous in-vivo studies suggest that the ratio of total lumbar rotation over pelvic rotation (lumbo-pelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Similarly, there is also evidence that the lumbo-pelvic rhythm is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.009

    authors: Liu T,Khalaf K,Adeeb S,El-Rich M

    更新日期:2019-01-03 00:00:00

  • Relative contribution of the pressure variations under the feet and body weight distribution over both legs in the control of upright stance.

    abstract::The resultant centre of pressure (CP(Res)) trajectories are aimed at controlling body movements in upright stance. When standing on two legs, these trajectories are generated by exerting reaction forces under each foot and by loading-unloading mechanisms intervening at the hip level. To assess the respective contribut...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.11.003

    authors: Rougier PR

    更新日期:2007-01-01 00:00:00

  • Similarity in the fatigue behavior of trabecular bone across site and species.

    abstract::Within the context of improving knowledge of the structure-function relations for trabecular bone for cyclic loading, we hypothesized that the S-N curve for cyclic compressive loading of trabecular bone, after accounting for differences in monotonic strength behavior, does not depend on either site or species. Thirty-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00245-8

    authors: Haddock SM,Yeh OC,Mummaneni PV,Rosenberg WS,Keaveny TM

    更新日期:2004-02-01 00:00:00

  • A finite viscoelastic-plastic model for describing the uniaxial ratchetting of soft biological tissues.

    abstract::In this paper, a phenomenological constitutive model is constructed to describe the uniaxial ratchetting (i.e., the cyclic accumulation of inelastic deformation) of soft biological tissues in the framework of finite viscoelastic-plasticity. The model is derived from a polyconvex elastic free energy function and addres...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.01.004

    authors: Zhu Y,Kang G,Kan Q,Yu C

    更新日期:2014-03-21 00:00:00

  • The force resulting from the action of mono- and biarticular muscles in a limb.

    abstract::Human and animal limbs can be modelled as a chain of segments connected at joints. For a static limb, the force exerted at the endpoint due to the force of a single muscle has been calculated. It turns out that there are marked differences in the action of mono- vs. biarticular muscles. Monoarticular muscles produce a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00056-2

    authors: Hof AL

    更新日期:2001-08-01 00:00:00