Ligament fibre recruitment at the human ankle joint complex in passive flexion.

Abstract:

:Knowledge of ligament fibre recruitment at the human ankle joint complex is a fundamental prerequisite for analysing mobility and stability. Previous experimental and modelling studies have shown that ankle motion must be guided by fibres within the calcaneofibular and tibiocalcaneal ligaments, which remain approximately isometric during passive flexion. The purpose of this study was to identify these fibres. Three below-knee amputated specimens were analysed during passive flexion with combined radiostereometry for bone pose estimation and 3D digitisation for ligament attachment area identification. A procedure based on singular value decomposition enabled matching bone pose with digitised data and therefore reconstructing position in space of ligament attachment areas in each joint position. Eleven ordered fibres, connecting corresponding points on origin and insertion curves, were modelled for each of the following ligaments: posterior talofibular, calcaneofibular, anterior talofibular, posterior tibiotalar, tibiocalcaneal, and anterior tibiotalar. The measured changes in length for the ligament fibres revealed patterns of tightening and slackening. The most anterior fibre of the calcaneofibular and the medio-anterior fibre of the tibiocalcaneal ligament exhibited the most isometric behaviour, as well as the most posterior fibre of the anterior talofibular ligament. Fibres within the calcaneofibular ligament remain parallel in the transverse plane, while those within the tibiocalcaneal ligament become almost parallel in joint neutral position. For both these ligaments, fibres maintain their relative inclination in the sagittal plane throughout the passive flexion range. The observed significant change in both shape and orientation of the ankle ligaments suggest that this knowledge is fundamental for future mechanical analysis of their response to external forces.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Stagni R,Leardini A,Ensini A

doi

10.1016/j.jbiomech.2004.02.043

keywords:

subject

Has Abstract

pub_date

2004-12-01 00:00:00

pages

1823-9

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021929004001277

journal_volume

37

pub_type

杂志文章
  • Stability basin estimates fall risk from observed kinematics, demonstrated on the Sit-to-Stand task.

    abstract::The ability to quantitatively measure stability is essential to ensuring the safety of locomoting systems. While the response to perturbation directly reflects the stability of a motion, this experimental method puts human subjects at risk. Unfortunately, existing indirect methods for estimating stability from unpertu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.022

    authors: Shia V,Moore TY,Holmes P,Bajcsy R,Vasudevan R

    更新日期:2018-04-27 00:00:00

  • Application and validation of the lattice Boltzmann method for modelling flow-related clotting.

    abstract::The purpose of this paper is to present a simple clotting model, based on residence time and shear stress distribution, that can simulate the deposition over time of enzyme-activated milk in an in vitro system. Results for the model are compared with experiments exhibiting clot deposition in the region of a sharp-edge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.026

    authors: Harrison SE,Smith SM,Bernsdorf J,Hose DR,Lawford PV

    更新日期:2007-01-01 00:00:00

  • An equation to calculate individual muscle contributions to joint stability.

    abstract::The purpose of the current paper was to use the energy approach to develop a simplified equation for quantifying individual muscle contributions to mechanical stability about all three axes of a particular joint. Specific examples are provided for muscles acting about the lumbar spine's L4/L5 joint. The stability equa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.004

    authors: Potvin JR,Brown SH

    更新日期:2005-05-01 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • In vitro analysis of localized aneurysm rupture.

    abstract::In this study, bulge inflation tests were used to characterize the failure response of 15 layers of human ascending thoracic aortic aneurysms (ATAA). Full field displacement data were collected during each of the mechanical tests using a digital image stereo-correlation (DIS-C) system. Using the collected displacement...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.012

    authors: Romo A,Badel P,Duprey A,Favre JP,Avril S

    更新日期:2014-02-07 00:00:00

  • Stance and swing phase detection during level and slope walking in the cat: effects of slope, injury, subject and kinematic detection method.

    abstract::In quadrupeds, there have been limited comparisons of gait timing events detection (e.g., paw contact, PC and paw-off, PO) determined from kinematics and forceplates. The goal of this study was to investigate the effect of different slopes (0, -27, +27°), recovery times after ankle extensor nerve injury and repair (2,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.013

    authors: Pantall A,Gregor RJ,Prilutsky BI

    更新日期:2012-05-11 00:00:00

  • Non-periodicity of blood flow and its influence on wall shear stress in the carotid artery bifurcation: An in vivo measurement-based computational study.

    abstract::Although arterial blood flow is physiologically non-periodic under resting conditions, periodic flow assumption has been widely adopted in most hemodynamic studies. So far, it remains unclear how the non-periodicity of blood flow would influence local hemodynamic parameters, especially wall shear stress (WSS) that ass...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109617

    authors: Zhou X,Yin L,Xu L,Liang F

    更新日期:2020-03-05 00:00:00

  • Cost-effective (gaming) motion and balance devices for functional assessment: Need or hype?

    abstract::In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, som...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.011

    authors: Bonnechère B,Jansen B,Van Sint Jan S

    更新日期:2016-09-06 00:00:00

  • Numerical analysis of Venous External Scaffolding Technology for Saphenous Vein Grafts.

    abstract::This paper presents a method for analyzing and comparing numerically Saphenous Vein Grafts (SVGs) following Coronary Artery Bypass Graft surgery (CABG). The method analyses the flow dynamics inside vein grafts with and without supporting using Venous External Scaffolding Technology (VEST). The numerical method uses pa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.011

    authors: Meirson T,Orion E,Avrahami I

    更新日期:2015-07-16 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

    abstract::The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.02.042

    authors: Dennis DA,Mahfouz MR,Komistek RD,Hoff W

    更新日期:2005-02-01 00:00:00

  • Are mineralized tissues open crystal foams reinforced by crosslinked collagen? Some energy arguments.

    abstract::Which of the elementary components (hydroxyapatite (HA) crystals, collagen, non-collagenous organic matter, water) do significantly contribute to the ultrastructural elastic stiffness magnitude and anisotropy of mineralized tissues; and how, i.e. through which shapes and assemblages (which micromechanical morphology)?...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00080-5

    authors: Hellmich Ch,Ulm FJ

    更新日期:2002-09-01 00:00:00

  • Adaptational responses in dynamic stability during disturbed walking in the elderly.

    abstract::The purpose of this study was to examine the age-related predictive and feedback adaptive locomotor improvements in the components of dynamic stability control during disturbed walking. Thirteen old (62-74 yrs) and ten young (23-30 yrs) male subjects performed a gait protocol on a gangway, which included one covered e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.025

    authors: Bierbaum S,Peper A,Karamanidis K,Arampatzis A

    更新日期:2010-08-26 00:00:00

  • Importance of preswing rectus femoris activity in stiff-knee gait.

    abstract::Stiff-knee gait is characterized by diminished and delayed knee flexion during swing. Rectus femoris transfer surgery, a common treatment for stiff-knee gait, is often recommended when a patient exhibits prolonged activity of the rectus femoris muscle during swing. Treatment outcomes are inconsistent, in part, due to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.030

    authors: Reinbolt JA,Fox MD,Arnold AS,Ounpuu S,Delp SL

    更新日期:2008-08-07 00:00:00

  • A mechanical apparatus with microprocessor controlled stress profile for cyclic compression of cultured articular cartilage explants.

    abstract::An apparatus was designed for mechanical compression of cultured articular cartilage explants with acylindrical plain-ended loading head (diameter 2-5 mm) driven by a stepping motor. A load cell under the culture dish was applied for feedback regulation utilizing a microprocessor-based control unit. The operating prog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90232-7

    authors: Parkkinen JJ,Lammi MJ,Karjalainen S,Laakkonen J,Hyvärinen E,Tiihonen A,Helminen HJ,Tammi M

    更新日期:1989-01-01 00:00:00

  • Micromechanical modeling of elastic properties of cortical bone accounting for anisotropy of dense tissue.

    abstract::The paper analyzes the connection between microstructure of the osteonal cortical bone and its overall elastic properties. The existing models either neglect anisotropy of the dense tissue or simplify cortical bone microstructure (accounting for Haversian canals only). These simplifications (related mostly to insuffic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.019

    authors: Salguero L,Saadat F,Sevostianov I

    更新日期:2014-10-17 00:00:00

  • Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator.

    abstract::The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine kne...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.043

    authors: Liu A,Jennings LM,Ingham E,Fisher J

    更新日期:2015-09-18 00:00:00

  • Measurement of local diffusion and composition in degraded articular cartilage reveals the unique role of surface structure in controlling macromolecular transport.

    abstract::Developing effective therapeutics for osteoarthritis (OA) necessitates that such molecules can reach and target chondrocytes within articular cartilage. However, predicting how well very large therapeutic molecules diffuse through cartilage is often difficult, and the relationship between local transport mechanics for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.019

    authors: DiDomenico CD,Kaghazchi A,Bonassar LJ

    更新日期:2019-01-03 00:00:00

  • Physical properties of resistance vessel wall in peripheral blood flow regulation--I. Mathematical model.

    abstract::A mathematical model is introduced to investigate the influence of the physical properties of the resistance vessel wall on the metabolic and myogenic mechanisms. The resistance vessel wall is assumed to have an elastic property and the elastic modulus to be a function of pressure (myogenic) and flow (metabolic). Bloo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90033-x

    authors: Iida N

    更新日期:1989-01-01 00:00:00

  • The effects of -80 °C short-term storage on the mechanical response of tricuspid valve leaflets.

    abstract::Mechanical testing of soft tissues would ideally rely on using fresh specimens. In the event that fresh tissues are not readily available, alternative measures, such as storing fresh specimens at -80 °C, could be considered. Previous studies have shown that changes in the mechanical properties of the tissues due to fr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109462

    authors: Salinas SD,Clark MM,Amini R

    更新日期:2020-01-02 00:00:00

  • Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography.

    abstract::The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT po...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.030

    authors: Whittier DE,Manske SL,Kiel DP,Bouxsein M,Boyd SK

    更新日期:2018-10-26 00:00:00

  • Comparison of two methods for calculating the frictional properties of articular cartilage using a simple pendulum and intact mouse knee joints.

    abstract::In attempts to better understand the etiology of osteoarthritis, a debilitating joint disease that results in the degeneration of articular cartilage (AC) in synovial joints, researchers have focused on joint tribology, the study of joint friction, lubrication, and wear. Several different approaches have been used to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.024

    authors: Drewniak EI,Jay GD,Fleming BC,Crisco JJ

    更新日期:2009-08-25 00:00:00

  • Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.

    abstract::Intramedullary femoral nails provide an ideal mechanical axis for periprosthetic fracture fixation. Slotted nails allow a connection to a total knee arthroplasty (TKA) stem. This study aims to compare implant and construct stiffness, interfragmentary movement and cycles to failure between an antegrade slotted femoral ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110109

    authors: Lenz M,Acklin YP,Kasper LA,Mischler D,Varga P,Zderic I,Gehweiler D,Klos K,Gueorguiev B,Stoffel K

    更新日期:2021-01-22 00:00:00

  • What is the role of the convective current density in the real-time calcium response of cultured bone cells to fluid flow?

    abstract::Cultured cells subjected to fluid flow are exposed to mechanical forces and electrokinetic forces. The convective current establishes an electrokinetic force created by the flow-dependent transport of mobile ions in the media over the charged cell surfaces. This current can be expressed as a current density, the curre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)84535-0

    authors: Hung CT,Allen FD,Pollack SR,Brighton CT

    更新日期:1996-11-01 00:00:00

  • Finite element models predict cancellous apparent modulus when tissue modulus is scaled from specimen CT-attenuation.

    abstract::High-resolution architecture-based finite element models are commonly used for characterizing the mechanical behavior of cancellous bone. The vast majority of studies use homogeneous material properties to model trabecular tissue. The objectives of this study were to demonstrate that inhomogeneous finite element model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.10.002

    authors: Bourne BC,van der Meulen MC

    更新日期:2004-05-01 00:00:00

  • Non-interacting modes for stress, strain and energy in anisotropic hard tissue.

    abstract::The six non-interacting modes for stress, strain and energy in an orthotropic elastic model of human femoral cortical bone tissue are discussed and illustrated. The stress and strain modes are illustrated using the representation of the stress and strain fields around a circular hole in a flat plate of cortical bone s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90311-a

    authors: Cowin SC,Sadegh AM

    更新日期:1991-01-01 00:00:00

  • In vivo biomechanical behavior of the human heel pad during the stance phase of gait.

    abstract::A technique is introduced for simultaneous measurements of the heel pad tissue deformation and the heel-ground contact stresses developing during the stance phase of gait. Subjects walked upon a gait platform integrating the contact pressure display optical method for plantar pressure measurements and a digital radiog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00143-9

    authors: Gefen A,Megido-Ravid M,Itzchak Y

    更新日期:2001-12-01 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.

    abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.049

    authors: Anderst WJ,Donaldson WF 3rd,Lee JY,Kang JD

    更新日期:2015-05-01 00:00:00

  • Dominant role of interface over knee angle for cushioning impact loading and regulating initial leg stiffness.

    abstract::For in vivo impact loadings administered under controlled initial conditions, it was hypothesized that larger initial knee angles (IKA) and softer impacting interfaces would reduce impact loading and initial leg stiffness. A human pendulum was used to deliver controlled impacts to the right foot of 21 subjects for thr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Lafortune MA,Hennig EM,Lake MJ

    更新日期:1996-12-01 00:00:00