Abstract:
:The successful development of early-stage cartilage and meniscus repair interventions in the knee requires biomechanical and biotribological understanding of the design of the therapeutic interventions and their tribological function in the natural joint. The aim of this study was to develop and validate a porcine knee model using a whole joint knee simulator for investigation of the tribological function and biomechanical properties of the natural knee, which could then be used to pre-clinically assess the tribological performance of cartilage and meniscal repair interventions prior to in vivo studies. The tribological performance of standard artificial bearings in terms of anterior-posterior (A/P) shear force was determined in a newly developed six degrees of freedom tribological joint simulator. The porcine knee model was then developed and the tribological properties in terms of shear force measurements were determined for the first time for three levels of biomechanical constraints including A/P constrained, spring force semi-constrained and A/P unconstrained conditions. The shear force measurements showed higher values under the A/P constrained condition (predominantly sliding motion) compared to the A/P unconstrained condition (predominantly rolling motion). This indicated that the shear force simulation model was able to differentiate between tribological behaviours when the femoral and tibial bearing was constrained to slide or/and roll. Therefore, this porcine knee model showed the potential capability to investigate the effect of knee structural, biomechanical and kinematic changes, as well as different cartilage substitution therapies on the tribological function of natural knee joints.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Liu A,Jennings LM,Ingham E,Fisher Jdoi
10.1016/j.jbiomech.2015.07.043subject
Has Abstractpub_date
2015-09-18 00:00:00pages
3004-11issue
12eissn
0021-9290issn
1873-2380pii
S0021-9290(15)00440-6journal_volume
48pub_type
杂志文章abstract::Differences in motion patterns subserving the same movement goal can be identified qualitatively. These alternatives, which may characterize 'movement techniques' (e.g., the stoop and the squat lifting technique), may be associated with significantly different biomechanical constraints and physiological responses. Des...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.04.014
更新日期:2005-03-01 00:00:00
abstract::Solids such as polymers, soft biological tissues display visco-hyperelastic, isochoric and finite deformation behaviour. The incompressibility constraint imposed severe restriction on the displacement field results in volumetric locking. Many techniques have been developed to address the issue such as reduced integrat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.03.016
更新日期:2018-05-17 00:00:00
abstract::This study evaluated the feasibility of assessing continuous strain distributions on fracture callus cross-sections with an electronic speckle pattern interferometry (ESPI) system. Mid-sagittal callus cross-sections were harvested from ovine tibiae. One low stiffness (LS) specimen and one high stiffness (HS) specimen ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.10.024
更新日期:2008-01-01 00:00:00
abstract::Anterior cruciate ligament (ACL) injury can result in failure to return to pre-injury activity levels and future osteoarthritis predisposition. Single leg hop is used in late rehabilitation to evaluate recovery and inform treatment but biomechanical understanding of this activity is insufficient. This study investigat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.11.046
更新日期:2014-02-07 00:00:00
abstract::Hamstring muscle strain injury is one of the most commonly seen injuries in sports such as track and field, soccer, football, and rugby. The purpose of this study was to advance our understanding of the mechanisms of hamstring muscle strain injuries during over ground sprinting by investigating hamstring muscle-tendon...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.09.005
更新日期:2008-11-14 00:00:00
abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)00091-h
更新日期:1995-05-01 00:00:00
abstract::This work describes a dynamic model of the low back that incorporates extensive anatomical detail of the musculo-ligamentous-skeletal system to predict the load time histories of individual tissues. The dynamic reaction moment about L4/L5 was determined during lateral bending from a linked-segment model. This reaction...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90259-4
更新日期:1992-04-01 00:00:00
abstract::Dynamic stability requirements have never been quantified when long-term manual wheelchair users transfer themselves in a seated position from an initial surface to a target surface, a functional task commonly referred to as sitting pivot transfers (SPTs). Ten individuals with spinal cord injury (SCI), who rely on a m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.02.018
更新日期:2012-05-11 00:00:00
abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.11.005
更新日期:2007-01-01 00:00:00
abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.041
更新日期:2010-03-03 00:00:00
abstract::The estimation of the skeletal motion obtained from marker-based motion capture systems is known to be affected by significant bias caused by skin movement artifacts, which affects joint center and rotation axis estimation. Among different techniques proposed in the literature, that based on rigid body model, still th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.09.032
更新日期:2005-11-01 00:00:00
abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00191-8
更新日期:2000-03-01 00:00:00
abstract::Computation of muscle excitation patterns that produce coordinated movements of muscle-actuated dynamic models is an important and challenging problem. Using dynamic optimization to compute excitation patterns comes at a large computational cost, which has limited the use of muscle-actuated simulations. This paper int...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00432-3
更新日期:2003-03-01 00:00:00
abstract::Orthopaedic management of femoral head osteonecrosis is a common clinical problem for which there presently is no good solution. Current animal models are inappropriate to study potential new solutions, since it has been difficult to replicate the natural history of structural collapse seen in the human disorder. Rece...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00154-4
更新日期:2003-09-01 00:00:00
abstract::The breaking of left-right symmetry in the mammalian embryo is believed to occur in a transient embryonic structure, the node, when cilia create a leftward flow of liquid. The two-cilia hypothesis proposes that the node contains two kinds of primary cilia: motile cilia that rotate autonomously to generate the leftward...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.10.040
更新日期:2009-02-09 00:00:00
abstract::Despite the paramount function of the thumb in daily life, thumb biomechanical models have been little developed and studied. Moreover, only two studies provided quantitative anthropometric data of tendon moment arms. To investigate thumb tendon tensions, biomechanicians and clinicians have to know the performances an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.03.052
更新日期:2009-08-07 00:00:00
abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00202-x
更新日期:2000-04-01 00:00:00
abstract::Individuals with spastic cerebral palsy (SCP) exhibit restricted joint range of motion and increased joint stiffness due to structural alterations of their muscles. Little is known about which muscle-tendon structures are responsible for these alterations. The aim of this study was to compare the passive mechanics of ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.06.008
更新日期:2011-09-02 00:00:00
abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.03.009
更新日期:2018-04-27 00:00:00
abstract::Electromyography (EMG) biofeedback training affords patients a better sense of the different muscle activation patterns involved in the movement of the shoulder girdle. It is important to address scapular kinematics with labourers who have daily routines involving large amounts of lifting at shoulder level or higher. ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.04.036
更新日期:2016-06-14 00:00:00
abstract::The purpose of this study was to examine the age-related predictive and feedback adaptive locomotor improvements in the components of dynamic stability control during disturbed walking. Thirteen old (62-74 yrs) and ten young (23-30 yrs) male subjects performed a gait protocol on a gangway, which included one covered e...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.04.025
更新日期:2010-08-26 00:00:00
abstract::In this study, a new radiostereometric analysis (RSA) calibration cage was developed with the aim of improving the accuracy and precision of RSA. This development consisted of three steps: a numerical simulation technique was first used to design the new cage; a synthetic imaging method was then implemented to predict...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.11.012
更新日期:2008-01-01 00:00:00
abstract::Intravesical and urethral pressure signals during cough and Valsalva maneuvers for 15 continent women were analyzed with frequency spectrum analysis. Clear modulation of the urethral pressure changes by the intravesical pressure rise during stress maneuvers was demonstrated in the frequency bands of 14 and 7 Hz for co...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(01)00006-9
更新日期:2001-05-01 00:00:00
abstract::In this study, bulge inflation tests were used to characterize the failure response of 15 layers of human ascending thoracic aortic aneurysms (ATAA). Full field displacement data were collected during each of the mechanical tests using a digital image stereo-correlation (DIS-C) system. Using the collected displacement...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.12.012
更新日期:2014-02-07 00:00:00
abstract::An asymptotic analysis of a lubrication problem is presented for a model of articular cartilage and synovial fluid under the squeeze-film condition. This model is based upon the following constitutive assumptions: (1) articular cartilage is a linear porous-permeable biphasic material filled with a linearly viscous flu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90024-u
更新日期:1992-03-01 00:00:00
abstract::The role of bone water in the activity of this organ is essential in structuring apatite crystals, providing pathways for nutrients and waste involved in the metabolism of bone cells and participating in bone remodelling mechanotransduction. It is commonly accepted that bone presents three levels of porosity, namely t...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.07.025
更新日期:2015-09-18 00:00:00
abstract::Previous investigations of morphology for human carotid artery bifurcation from infancy to young adulthood found substantial growth of the internal carotid artery with advancing age, and the development of the carotid sinus at the root of the internal carotid artery during teenage years. Although the reasons for the a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.009
更新日期:2015-04-13 00:00:00
abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90057-l
更新日期:1993-08-01 00:00:00
abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.07.025
更新日期:2008-10-20 00:00:00
abstract::Resident cells in the surface epitenon and internal compartment of flexor tendons are subjected to cyclic mechanical load as muscle contracts to move limbs or digits. Tendons are largely tensile load bearing tissues and are highly matrix intensive with nondividing cells providing maintenance functions. However, when a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00098-4
更新日期:1995-12-01 00:00:00