Mechanisms of female urinary continence under stress: frequency spectrum analysis.

Abstract:

:Intravesical and urethral pressure signals during cough and Valsalva maneuvers for 15 continent women were analyzed with frequency spectrum analysis. Clear modulation of the urethral pressure changes by the intravesical pressure rise during stress maneuvers was demonstrated in the frequency bands of 14 and 7 Hz for cough and Valsalva, respectively. The linearity between the urethral and intravesical pressure signals was strong for cough, but relatively weaker for Valsalva. The observed linearity lead to the formulation of a modified continence equation to mathematically quantify stress leak point pressure (sLPP): sLPP=MUCP/(1-alpha1)+RBP. This algebraic equation demonstrated that sLPP depends on pressure transmission, resting bladder pressure, and maximum urethral closure pressure. The equation was validated with excellent theoretical predictions for the 15 continent subjects (R(2)=0.98 and 0.97 for cough and Valsalva leak point pressure, respectively) and good but somewhat weaker predictions for 46 stress incontinent women (R(2)=0.79 and 0.48, respectively). It has been shown that pressure transmission plays the most important role in female continence function, while it may be attributable to passive structural origin as evidenced by the minimal time delay between the two pressure signals, in the order of a few milliseconds. It can be concluded that coughing seems to have a more mechanical, rather than neuromuscular basis for its signal dynamics. This study suggests that a complete assessment of female stress continence function requires comprehensive urodynamic information in terms of pressure transmission, maximum urethral closure pressure, and resting bladder pressure.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kim K,Jurnalov CD,Ham S,Webb MJ,An K

doi

10.1016/s0021-9290(01)00006-9

keywords:

subject

Has Abstract

pub_date

2001-05-01 00:00:00

pages

687-91

issue

5

eissn

0021-9290

issn

1873-2380

pii

S0021929001000069

journal_volume

34

pub_type

杂志文章
  • Associations of hamstring and triceps surae muscle spasticity and stance phase gait kinematics in children with spastic diplegic cerebral palsy.

    abstract::Clinical decisions on interventions to improve function in children with cerebral palsy (CP) are based, in part, on hypothesized interactions amongst physical signs of CP and functional deficits. However, a knowledge gap exists regarding associations between spasticity and gait function. This study quantified associat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110218

    authors: Bowal N,Nettel-Aguirre A,Ursulak G,Condliffe E,Robu I,Goldstein S,Emery C,Ronsky JL,Kuntze G

    更新日期:2021-01-16 00:00:00

  • The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture--an FEM study.

    abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00189-x

    authors: Gardner TN,Stoll T,Marks L,Mishra S,Knothe Tate M

    更新日期:2000-04-01 00:00:00

  • Load transfer across the pelvic bone.

    abstract::Earlier experimental and finite element studies notwithstanding, the load transfer and stress distribution in the pelvic bone and the acetabulum in normal conditions are not well understood. This hampers the development of orthopaedic reconstruction methods. The present study deals with more precise finite element ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00125-n

    authors: Dalstra M,Huiskes R

    更新日期:1995-06-01 00:00:00

  • Unique behavior of dermal cells from regenerative mammal, the African Spiny Mouse, in response to substrate stiffness.

    abstract::The African Spiny Mouse (Acomys spp.) is a unique outbred mammal capable of full, scar-free skin regeneration. In vivo, we have observed rapid reepithelialization and deposition of normal dermis in Acomys after wounding. Acomys skin also has a lower modulus and lower elastic energy storage than normal lab mice, Mus mu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.005

    authors: Stewart DC,Serrano PN,Rubiano A,Yokosawa R,Sandler J,Mukhtar M,Brant JO,Maden M,Simmons CS

    更新日期:2018-11-16 00:00:00

  • Anatomic variation in the elastic inhomogeneity and anisotropy of human femoral cortical bone tissue is consistent across multiple donors.

    abstract::Numerical models commonly account for elastic inhomogeneity in cortical bone using power-law scaling relationships with various measures of tissue density, but limited experimental data exists for anatomic variation in elastic anisotropy. A recent study revealed anatomic variation in the magnitude and anisotropy of el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.009

    authors: Rudy DJ,Deuerling JM,Espinoza Orías AA,Roeder RK

    更新日期:2011-06-03 00:00:00

  • Patterns in the knee flexion-extension moment profile during stair ascent and descent in patients with total knee arthroplasty.

    abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.026

    authors: McClelland JA,Feller JA,Menz HB,Webster KE

    更新日期:2014-06-03 00:00:00

  • Modela-r as a Froude and Strouhal dimensionless numbers combination for dynamic similarity in running.

    abstract::The aim of this study was to test the hypothesis that running at fixed fractions of Froude (Nfr) and Strouhal (Str) dimensionless numbers combinations induce dynamic similarity between humans of different sizes. Nineteen subjects ran in three experimental conditions, (i) constant speed, (ii) similar speed (Nfr) and (i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.012

    authors: Villeger D,Costes A,Watier B,Moretto P

    更新日期:2014-12-18 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Transient body sway characteristics during single-leg quiet stance in ballet dancers and young adults.

    abstract::This study explored transient characteristics of body sway during single-leg quiet stance in young ballet dancers (n = 41) and young healthy adults (n = 58). We compared the groups in terms of center of pressure (CoP) parameters (CoP velocity and amplitude, averaged across the duration of the 30-s trial), and the tran...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110195

    authors: Kozinc Ž,Šarabon N

    更新日期:2021-01-22 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • A constitutive model for vascular tissue that integrates fibril, fiber and continuum levels with application to the isotropic and passive properties of the infrarenal aorta.

    abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.015

    authors: Martufi G,Gasser TC

    更新日期:2011-09-23 00:00:00

  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography.

    abstract::The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT po...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.030

    authors: Whittier DE,Manske SL,Kiel DP,Bouxsein M,Boyd SK

    更新日期:2018-10-26 00:00:00

  • A physiological approach to the simulation of bone remodeling as a self-organizational control process.

    abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90049-3

    authors: Mullender MG,Huiskes R,Weinans H

    更新日期:1994-11-01 00:00:00

  • Reducing upper airway collapse at lower continuous positive airway titration pressure.

    abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.005

    authors: Ashaat S,Al-Jumaily AM

    更新日期:2016-12-08 00:00:00

  • Density and hydration of fresh and fixed human skeletal muscle.

    abstract::The maximum tetanic tension of skeletal muscle (P(0)) is often estimated based on calculation of physiological cross-sectional area (PCSA). PCSA depends on muscle volume, pennation angle, and fiber length. Studies documenting PCSA in fixed human muscles usually compute muscle volume by dividing muscle mass by density....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.10.001

    authors: Ward SR,Lieber RL

    更新日期:2005-11-01 00:00:00

  • A three-dimensional mathematical model of the thoracolumbar fascia and an estimate of its biomechanical effect.

    abstract::The thoracolumbar fascia (TLF) provides a means of attachment to the lumbar spine for several muscles including the transverse abdominis, and parts of the latissimus dorsi and internal oblique muscles. Previous biomechanical models of the lumbar spine either tend to omit the TLF on the assumption that its contribution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.022

    authors: Gatton ML,Pearcy MJ,Pettet GJ,Evans JH

    更新日期:2010-10-19 00:00:00

  • Representing and identifying alternative movement techniques for goal-directed manual tasks.

    abstract::Differences in motion patterns subserving the same movement goal can be identified qualitatively. These alternatives, which may characterize 'movement techniques' (e.g., the stoop and the squat lifting technique), may be associated with significantly different biomechanical constraints and physiological responses. Des...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.014

    authors: Park W,Martin BJ,Choe S,Chaffin DB,Reed MP

    更新日期:2005-03-01 00:00:00

  • The influence of the instabilities in modelling arteriovenous junction haemodynamics.

    abstract::The arteriovenous junction is characterised by high flow rates, large pressure difference and typically a palpable thrill or audible bruit, associated with turbulent flow. However, the arteriovenous junction is frequently studied with the assumption of streamline flow. This assumption is based on the Reynolds number c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.038

    authors: Broderick SP,Houston JG,Walsh MT

    更新日期:2015-10-15 00:00:00

  • Continuum modeling of deformation and aggregation of red blood cells.

    abstract::In order to gain better understanding for rheology of an isolated red blood cell (RBC) and a group of multiple RBCs, new continuum models for describing mechanical properties of cellular structures of an RBC and inter-cellular interactions among multiple RBCs are developed. The viscous property of an RBC membrane, whi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.027

    authors: Yoon D,You D

    更新日期:2016-07-26 00:00:00

  • Failure of mineralized collagen fibrils: modeling the role of collagen cross-linking.

    abstract::Experimental evidence demonstrates that collagen cross-linking in bone tissue significantly influences its deformation and failure behavior yet difficulties exist in determining the independent biomechanical effects of collagen cross-linking using in vitro and in vivo experiments. The aim of this study is to use a nan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.017

    authors: Siegmund T,Allen MR,Burr DB

    更新日期:2008-01-01 00:00:00

  • Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels.

    abstract::Time-domain-based one-dimensional wave propagation models of the arterial system are preferable over one-dimensional wave propagation models in the frequency domain since the latter neglect the non-linear convection forces present in the physiological situation, especially when the vessel is tapered. Moreover, one-dim...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.09.014

    authors: Bessems D,Giannopapa CG,Rutten MC,van de Vosse FN

    更新日期:2008-01-01 00:00:00

  • Biomechanical evaluation of walking and cycling in children.

    abstract::Physical activity in children is important as it leads to healthy growth due to physiological benefits. However, a physiological benefit can be partially negated by excessive or unphysiological loads within the joints. To gain an initial understanding into this, the present study sought to compare joint loading betwee...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.051

    authors: Greca JPA,Ryan J,Baltzopoulos V,Korff T

    更新日期:2019-04-18 00:00:00

  • Apparent mass of the standing human body when using a whole-body vibration training machine: Effect of knee angle and input frequency.

    abstract::Several studies have investigated the transmission of vibration from the vibrating plate of a whole-body vibration training machine (WBVTM) to different locations on the human body. No known work has investigated the interface force between the vibrating plate of the machine and the human body. This paper investigates...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.003

    authors: Nawayseh N,Hamdan S

    更新日期:2019-01-03 00:00:00

  • Peristaltic transport of blood: Casson model--II.

    abstract::The problem of peristaltic transport of blood in a uniform and non-uniform tube has been investigated, under zero Reynolds number and long wavelength approximation. Blood is represented by a two-layered fluid model consisting of a central layer of suspension of all erythrocytes, etc., assumed to be a Casson fluid, and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90140-4

    authors: Srivastava LM,Srivastava VP

    更新日期:1984-01-01 00:00:00

  • A little bit faster: Lower extremity joint kinematics and kinetics as recreational runners achieve faster speeds.

    abstract::There appears a linear relationship between small increases in running speed and cardiovascular health benefits. Encouraging or coaching recreational runners to increase their running speed to derive these health benefits might be more effective if their joint level kinematic and kinetic strategy was understood. The a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.010

    authors: Orendurff MS,Kobayashi T,Tulchin-Francis K,Tullock AMH,Villarosa C,Chan C,Kraus E,Strike S

    更新日期:2018-04-11 00:00:00

  • Fluid flow in bone in vitro.

    abstract::Recent dielectric measurements suggest that the electromechanical effect in wet (fluid saturated) bone is not due to a piezoelectric effect. This would imply that the electromechanical effect observed in wet bone is due to a streaming potential and is therefore dependent on fluid flow in stressed bone. A model for flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90054-9

    authors: Johnson MW,Chakkalakal DA,Harper RA,Katz JL,Rouhana SW

    更新日期:1982-01-01 00:00:00

  • Numerical analysis of pulsatile blood flow and vessel wall mechanics in different degrees of stenoses.

    abstract::Hemodynamics factors and biomechanical forces play key roles in atherogenesis, plaque development and final rupture. In this paper, we investigated the flow field and stress field for different degrees of stenoses under physiological conditions. Disease is modelled as axisymmetric cosine shape stenoses with varying di...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.023

    authors: Li MX,Beech-Brandt JJ,John LR,Hoskins PR,Easson WJ

    更新日期:2007-01-01 00:00:00

  • Musculoskeletal stiffness changes linearly in response to increasing load during walking gait.

    abstract::Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a tread...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.046

    authors: Caron RR,Lewis CL,Saltzman E,Wagenaar RC,Holt KG

    更新日期:2015-04-13 00:00:00