Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

Abstract:

:In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fixed ring" cable-driven experimental designs have been used; however, there have been concerns with the validity of this set-up in applying pure moment loading. This study involved directly comparing the loading state induced by a traditional "fixed ring" apparatus versus a novel "sliding ring" approach. Flexion-extension bending was performed on an artificial spine model and a single cadaveric test specimen, and the applied loading conditions to the specimen were measured with an in-line multiaxial load cell. The results showed that the fixed ring system applies flexion-extension moments that are 50-60% less than the intended values. This design also imposes non-trivial anterior-posterior shear forces, and non-uniform loading conditions were induced along the length of the specimen. The results of this study indicate that fixed ring systems have the potential to deviate from a pure moment loading state and that our novel sliding ring modification corrects this error in the original test design. This suggests that the proposed sliding ring design should be used for future in vitro spine biomechanics studies involving a cable-driven pure moment apparatus.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

doi

10.1016/j.jbiomech.2010.02.004

subject

Has Abstract

pub_date

2010-05-07 00:00:00

pages

1422-5

issue

7

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(10)00062-X

journal_volume

43

pub_type

杂志文章
  • Prior storage conditions and loading rate affect the in vitro fracture response of spinal segments under impact loading.

    abstract::Traumatic injuries of the spine are mostly the consequence of rapid overload e.g. impact loading. In vitro investigations on this topic usually encompass biomechanical testing using frozen/thawed specimens and employ quasi-static loading conditions. It is generally accepted that a freezing/thawing cycle does not alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.011

    authors: Dudli S,Haschtmann D,Ferguson SJ

    更新日期:2011-09-02 00:00:00

  • A novel approach to estimate trabecular bone anisotropy using a database approach.

    abstract::Continuum finite element (FE) models of bones have become a standard pre-clinical tool to estimate bone strength. These models are usually based on clinical CT scans and material properties assigned are chosen as isotropic based only on the density distribution. It has been shown, however, that trabecular bone elastic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.07.042

    authors: Hazrati Marangalou J,Ito K,Cataldi M,Taddei F,van Rietbergen B

    更新日期:2013-09-27 00:00:00

  • Feasibility of noninvasive evaluation of biophysical properties of tissue-engineered cartilage by using quantitative MRI.

    abstract::The application of tissue-engineered cartilage in a clinical setting requires a noninvasive method to assess the biophysical and biochemical properties of the engineered cartilage. Since articular cartilage is composed of 70-80% water and has dense extracellular matrixes (ECM), it is considered that the condition of t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.002

    authors: Miyata S,Numano T,Homma K,Tateishi T,Ushida T

    更新日期:2007-01-01 00:00:00

  • Age-associated changes in the mechanical properties of human cadaveric pelvic floor muscles.

    abstract::Proper function of the female pelvic floor requires intact pelvic floor muscles (PFMs). The prevalence of pelvic floor disorders (PFDs) increases substantially with age, in part due to clinically identified deterioration of PFM function with age. However, the etiology of this decline remains largely unknown. We previo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109436

    authors: Burnett LA,Cook M,Shah S,Michelle Wong M,Kado DM,Alperin M

    更新日期:2020-01-02 00:00:00

  • Haemodynamic effects of incomplete stent apposition in curved coronary arteries.

    abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.016

    authors: Chen WX,Poon EKW,Thondapu V,Hutchins N,Barlis P,Ooi A

    更新日期:2017-10-03 00:00:00

  • "Whither flows the fluid in bone?" An osteocyte's perspective.

    abstract::Bone represents a porous tissue containing a fluid phase, a solid matrix, and cells. Movement of the fluid phase within the pores or spaces of the solid matrix translates endogenous and exogenous mechanobiological, biochemical and electromechanical signals from the system that is exposed to the dynamic external enviro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(03)00123-4

    authors: Knothe Tate ML

    更新日期:2003-10-01 00:00:00

  • A telemetry-based device to determine the force-displacement behaviour of materials in high impact loading situations.

    abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00191-8

    authors: Chadwick EK,Nicol AC,Floyd S,Gray TG

    更新日期:2000-03-01 00:00:00

  • Probabilistic finite element prediction of knee wear simulator mechanics.

    abstract::Computational models have recently been developed to replicate experimental conditions present in the Stanmore knee wear simulator. These finite element (FE) models, which provide a virtual platform to evaluate total knee replacement (TKR) mechanics, were validated through comparisons with experimental data for a spec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.029

    authors: Laz PJ,Pal S,Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2006-01-01 00:00:00

  • Stress deprivation simultaneously induces over-expression of interleukin-1beta, tumor necrosis factor-alpha, and transforming growth factor-beta in fibroblasts and mechanical deterioration of the tissue in the patellar tendon.

    abstract::To test the hypothesis that stress deprivation induces over-expression of cytokines in the patellar tendon, 40 rats were divided into the following two groups. In the stress-shielded group, we slackened the patellar tendon in the right knee by drawing the patella toward the tibial tubercle with flexible wires. In the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.009

    authors: Uchida H,Tohyama H,Nagashima K,Ohba Y,Matsumoto H,Toyama Y,Yasuda K

    更新日期:2005-04-01 00:00:00

  • Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography.

    abstract::The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT po...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.030

    authors: Whittier DE,Manske SL,Kiel DP,Bouxsein M,Boyd SK

    更新日期:2018-10-26 00:00:00

  • Effect of geometrical imperfections in confined compression tests on parameter evaluation of hydrated soft tissues.

    abstract::Experimental tests, such as the confined and unconfined compression and the indentation tests, are traditionally used to determine the poroelastic properties of hydrated soft tissues (HSTs). The purpose of this study was to quantitatively evaluate the reliability of H(A) and K values as identified from experimental co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.020

    authors: Gervaso F,Pennati G,Boschetti F

    更新日期:2007-01-01 00:00:00

  • Gait dynamics on an inclined walkway.

    abstract:OBJECTIVE:This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN:Experimental, investigative. BACKGROUND:It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.025

    authors: McIntosh AS,Beatty KT,Dwan LN,Vickers DR

    更新日期:2006-01-01 00:00:00

  • Reproducibility analysis of upper limbs reachable workspace, and effects of acquisition protocol, sex and hand dominancy.

    abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.010

    authors: Clément J,Raison M,Rouleau DM

    更新日期:2018-02-08 00:00:00

  • Evaluation of left ventricular function based on simulated systolic flow dynamics computed from regional wall motion.

    abstract::Left ventricular (LV) chamber flow is undoubtedly influenced by the time-dependent regional motion of the LV wall. In an attempt to obtain diagnostic parameters based on LV chamber flow, we computed the LV chamber, two-dimensional systolic velocity and pressure distribution for two right anterior oblique (RAO) ventric...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90201-1

    authors: Schoephoerster RT,Silva CL,Ray G

    更新日期:1994-02-01 00:00:00

  • An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system.

    abstract::Inertial measurement units (IMUs) offer great opportunities to analyze segmental and joints kinematics. When combined with another motion capture system (MCS), for example, to validate new IMU-based applications or to develop mixed systems, it is necessary to align the local frame of the IMU sensors to the local frame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.009

    authors: Chardonnens J,Favre J,Aminian K

    更新日期:2012-08-31 00:00:00

  • Mechanics of toe and heel landing in stepping down in ongoing gait.

    abstract::When stepping down from a height difference in ongoing gait, subjects are known to use a heel landing at small height differences and switch to toe landing for larger height differences. We hypothesized that in toe landing, the leading leg can perform more negative work, to control the momentum gained during the desce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.022

    authors: van Dieën JH,Spanjaard M,Könemann R,Bron L,Pijnappels M

    更新日期:2008-08-07 00:00:00

  • Quantitative assessment of trunk deformation during running.

    abstract::The trunk has a multi-segmental structure and is composed of the cervical, thoracic, and lumber spines and surrounding soft tissue elements; this allows flexible deformation during dynamic movements. The purpose of this study was to quantitatively assess trunk deformation during dynamic movement. Ten male subjects per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.019

    authors: Kudo S,Fujimoto M,Isaka T,Nagano A

    更新日期:2017-07-05 00:00:00

  • In vivo muscular force analysis during the isometric flexion on a monkey's elbow.

    abstract::An experimental method has been developed to analyse muscular forces and torques in vivo during isometric flexion of the elbow in small monkeys (Macaca fascicularis). A mini-transducer was built with a view to measure forces in situ, without cutting tendons. The positions of tendon insertions were measured on anatomic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90220-5

    authors: Landjerit B,Maton B,Peres G

    更新日期:1988-01-01 00:00:00

  • A puzzle assembly strategy for fabrication of large engineered cartilage tissue constructs.

    abstract::Engineering of large articular cartilage tissue constructs remains a challenge as tissue growth is limited by nutrient diffusion. Here, a novel strategy is investigated, generating large constructs through the assembly of individually cultured, interlocking, smaller puzzle-shaped subunits. These constructs can be engi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.023

    authors: Nover AB,Jones BK,Yu WT,Donovan DS,Podolnick JD,Cook JL,Ateshian GA,Hung CT

    更新日期:2016-03-21 00:00:00

  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • On the effects of different strategies in modelling balloon-expandable stenting by means of finite element method.

    abstract::In recent years, computational structural analyses have emerged as important tools to investigate the mechanical response of stent placement into arterial walls. Although most coronary stents are expanded by inflating a polymeric balloon, realistic computational balloon models have been introduced only recently. In th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.027

    authors: Gervaso F,Capelli C,Petrini L,Lattanzio S,Di Virgilio L,Migliavacca F

    更新日期:2008-01-01 00:00:00

  • A constitutive model for vascular tissue that integrates fibril, fiber and continuum levels with application to the isotropic and passive properties of the infrarenal aorta.

    abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.015

    authors: Martufi G,Gasser TC

    更新日期:2011-09-23 00:00:00

  • Density of trunk tissues of young and medium age people.

    abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90360-f

    authors: Erdmann WS,Gos T

    更新日期:1990-01-01 00:00:00

  • Simultaneous shear and pressure sensor array for assessing pressure and shear at foot/ground interface.

    abstract::Foot ulceration is a diabetic complication estimated to result in over $1 billion worth of medical expenses per year in the United States alone. This multifaceted problem involves the response of plantar soft tissue to both external forces applied to the epidermis and internal changes such as vascular supply and neuro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.001

    authors: Mackey JR,Davis BL

    更新日期:2006-01-01 00:00:00

  • Inter- and intra-rater reliability of 3D kinematics during maximum mouth opening of asymptomatic subjects.

    abstract::Previous studies evaluated 3D human jaw movements using kinematic analysis systems during mouth opening, but information on the reliability of such measurements is still scarce. The purpose of this study was to analyze within- and between-session reliabilities, inter-rater reliability, standard error of measurement (S...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.038

    authors: Calixtre LB,Nakagawa TH,Alburquerque-Sendín F,da Silva Grüninger BL,de Sena Rosa LR,Oliveira AB

    更新日期:2017-11-07 00:00:00

  • Determination of the Poisson's ratio of the cell: recovery properties of chondrocytes after release from complete micropipette aspiration.

    abstract::Chondrocytes in articular cartilage are regularly subjected to compression and recovery due to dynamic loading of the joint. Previous studies have investigated the elastic and viscoelastic properties of chondrocytes using micropipette aspiration techniques, but in order to calculate cell properties, these studies have...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.11.006

    authors: Trickey WR,Baaijens FP,Laursen TA,Alexopoulos LG,Guilak F

    更新日期:2006-01-01 00:00:00

  • Functional strain in bone tissue as an objective, and controlling stimulus for adaptive bone remodelling.

    abstract::The skeleton consists of a series of elements with a variety of functions. In locations where shape or protection are of prime importance the bone's architecture is achieved during growth under direct genetic control. In locations where resistance to repetitive loading is important only the general form of the bone wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(87)90026-1

    authors: Lanyon LE

    更新日期:1987-01-01 00:00:00

  • Large deforming buoyant embolus passing through a stenotic common carotid artery: a computational simulation.

    abstract::Arterial embolism is responsible for the death of lots of people who suffers from heart diseases. The major risk of embolism in upper limbs is that the ruptured particles are brought into the brain, thus stimulating neurological symptoms or causing the stroke. We presented a computational model using fluid-structure i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.01.020

    authors: Vahidi B,Fatouraee N

    更新日期:2012-04-30 00:00:00

  • A potential role of smooth muscle tone in early hypertension: a theoretical study.

    abstract::A conspicuous long-term consequence of hypertension is a thickening of the arterial wall, which many suggest returns the circumferential wall stress toward its normal value. This thickening results from an increase in smooth muscle and extracellular matrix, with the associated growth and remodeling processes depending...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00178-7

    authors: Humphrey JD,Wilson E

    更新日期:2003-11-01 00:00:00

  • Comparison of three methods to estimate the center of mass during balance assessment.

    abstract::Evaluation of postural control is generally based on the interpretation of the center of pressure (COP) and the center of mass (COM) time series. The purpose of this study is to compare three methods to estimate the COM which are based on different biomechanical considerations. These methods are: (1) the kinematic met...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/S0021-9290(03)00251-3

    authors: Lafond D,Duarte M,Prince F

    更新日期:2004-09-01 00:00:00