Abstract:
:Bone represents a porous tissue containing a fluid phase, a solid matrix, and cells. Movement of the fluid phase within the pores or spaces of the solid matrix translates endogenous and exogenous mechanobiological, biochemical and electromechanical signals from the system that is exposed to the dynamic external environment to the cells that have the machinery to remodel the tissue from within. Hence, bone fluid serves as a coupling medium, providing an elegant feedback mechanism for functional adaptation. Until recently relatively little has been known about bone fluid per se or the influences governing the characteristics of its flow. This work is designed to review the current state of this emerging field. The structure of bone, as an environment for fluid flow, is discussed in terms of the properties of the spaces and channel walls through which the fluid flows and the influences on flow under physiological conditions. In particular, the development of the bone cell syncytium and lacunocanalicular system are presented, and pathways for fluid flow are described from the systemic to the organ, tissue, cellular and subcellular levels. Finally, exogenous and endogenous mechanisms for pressure-induced fluid movement through bone, including mechanical loading, vascular derived pressure gradients, and osmotic pressure gradients are discussed. The objective of this review is to survey the current understanding of the means by which fluid flow in bone is regulated, from the level of the skeletal system down to the level of osteocyte, and to provide impetus for future research in this area of signal transduction and coupling. An understanding of this important aspect of bone physiology has profound implications for restoration of function through innovative treatment modalities on Earth and in space, as well as for engineering of biomimetic replacement tissue.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Knothe Tate MLdoi
10.1016/s0021-9290(03)00123-4keywords:
subject
Has Abstractpub_date
2003-10-01 00:00:00pages
1409-24issue
10eissn
0021-9290issn
1873-2380pii
S0021929003001234journal_volume
36pub_type
杂志文章,评审abstract::The aim of this study was to analyze changes in gait variability and symmetry in distance runners. Fourteen competitive athletes ran on an instrumented treadmill for 10,000 m at speeds equivalent to 103% of their season's best time. Spatiotemporal and ground reaction force data were recorded at 1500, 3000, 5000, 7500 ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.08.008
更新日期:2018-10-05 00:00:00
abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.06.030
更新日期:2012-09-21 00:00:00
abstract::The aim of the present study was to develop a Hill type muscle model that accounts for the effects of shortening history. For this purpose, a function was derived that relates force depression to starting length, shortening amplitude and contraction velocity. History parameters were determined from short-range isokine...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00048-7
更新日期:1998-06-01 00:00:00
abstract::In this paper we introduce the concept of the functional (or equivalent) geometry of the knee, which is an attempt to reduce the natural knee with its complex geometry, frictional resistance and deformable cartilage into a two-dimensional joint comprising rigid femur and tibia in frictionless contact. An apparatus and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00141-9
更新日期:1999-01-01 00:00:00
abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.01.033
更新日期:2008-01-01 00:00:00
abstract::Experimental tests, such as the confined and unconfined compression and the indentation tests, are traditionally used to determine the poroelastic properties of hydrated soft tissues (HSTs). The purpose of this study was to quantitatively evaluate the reliability of H(A) and K values as identified from experimental co...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.02.020
更新日期:2007-01-01 00:00:00
abstract::Although arterial blood flow is physiologically non-periodic under resting conditions, periodic flow assumption has been widely adopted in most hemodynamic studies. So far, it remains unclear how the non-periodicity of blood flow would influence local hemodynamic parameters, especially wall shear stress (WSS) that ass...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109617
更新日期:2020-03-05 00:00:00
abstract:BACKGROUND:Performing a sit-to-stand (STS) can be a challenging task for older adults because of age-related declines in neuromuscular strength and coordination. We investigated the effects of different initial foot positions (IFPs) on kinematics, muscle activation patterns, and balance control during a STS in younger ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2021.110251
更新日期:2021-01-13 00:00:00
abstract::The paper focuses on research that enables the relationship between food and selected mechanical parameters do be determined. The main aim of the study was to designate, depending on the food: (1) the work of a single muscle (i.e. masseter, medial pterygoid, temporalis), and (2) the energy balance of mandibular elevat...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109800
更新日期:2020-06-09 00:00:00
abstract::Adult articular cartilage has depth-dependent mechanical and biochemical properties which contribute to zone-specific functions. The compressive moduli of immature cartilage and tissue-engineered cartilage are known to be lower than those of adult cartilage. The objective of this study was to determine if such tissues...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.11.002
更新日期:2007-01-01 00:00:00
abstract::Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.04.040
更新日期:2010-08-26 00:00:00
abstract::The cerebral ischemia and reperfusion rat model was employed in this experiment to study the rheological properties (i.e. viscosity, hematocrit, red blood cell deformability and thixotropic properties) of whole blood. The results of this study show that a significant relation exists between the duration of cerebral is...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00180-9
更新日期:2001-02-01 00:00:00
abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(83)90108-2
更新日期:1983-01-01 00:00:00
abstract::Local dynamic stability has been assessed by the short-term local divergence exponent (λS), which quantifies the average rate of logarithmic divergence of infinitesimally close trajectories in state space. Both increased and decreased local dynamic stability at faster walking speeds have been reported. This might pert...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.09.020
更新日期:2014-11-28 00:00:00
abstract::The purpose of this study was to propose and validate a new simple method for calculation of center of mass work during field running, in order to avoid the use of costly and inconvenient measurement devices. This method relies on spring-mass model and measurements of average horizontal velocity, and contact and fligh...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109369
更新日期:2019-12-03 00:00:00
abstract::The effect of tendons viscoelastic stiffness on the dynamic response of the cat's tibialis anterior muscle under isometric conditions was determined. It was shown that the dynamic response model of the muscle derived under sinusoidal contraction-relaxation in the range of 20-80% of its maximal isometric tension was no...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90355-q
更新日期:1991-01-01 00:00:00
abstract::Evaluation of workers' body posture in workstations is a prerequisite to estimate spinal loads and assess risk of injury for the subsequent design of preventive interventions. The Microsoft Kinect™ sensor is, in this regard, advantageous over the traditional skin-marker-based optical motion capture systems for being m...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110043
更新日期:2020-11-09 00:00:00
abstract::Ultrasound imaging has recently been used to distinguish the length changes of muscle fascicles from those of the whole muscle tendon complex during real life movements. The complicated three-dimensional architecture of pennate muscles can however cause heterogeneity in the length changes along the length of a muscle....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.035
更新日期:2007-01-01 00:00:00
abstract::The study verifies the development of active axial stress in the wall of mouse aorta over a range of physiological loads when the smooth muscle cells are stimulated to contract. The results obtained show that the active axial stress is virtually independent of the magnitude of pressure, but depends predominately on th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.05.025
更新日期:2012-07-26 00:00:00
abstract::Differences between wear-scar features of simulator-tested and retrieved tibial total knee replacement (TKR) liners have been reported. This disagreement may result from differences between in vivo kinematic profiles and those defined by the International Organization for Standardization (ISO). The purpose of this stu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.06.030
更新日期:2009-10-16 00:00:00
abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.016
更新日期:2017-10-03 00:00:00
abstract::The thoracolumbar fascia (TLF) provides a means of attachment to the lumbar spine for several muscles including the transverse abdominis, and parts of the latissimus dorsi and internal oblique muscles. Previous biomechanical models of the lumbar spine either tend to omit the TLF on the assumption that its contribution...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.022
更新日期:2010-10-19 00:00:00
abstract::Confinement of the heel due to the counter of the shoe is believed to influence heel pad biomechanics. Using a two-dimensional finite element model of the heel pad and shoe during a simulation of static standing, the aim of this study was to quantify the potential effect of confinement on internal heel pad stress. Non...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.004
更新日期:2007-01-01 00:00:00
abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00448-7
更新日期:2003-05-01 00:00:00
abstract::The aim of cryosurgery is to kill cells within a closely defined region maintained at a predetermined low temperature. To effectively kill cells, it is important to be able to predict and control the cooling rate over some critical range of temperatures and freezing states in order to regulate the spatial extent of in...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.11.005
更新日期:2007-01-01 00:00:00
abstract::While there are a growing number of increasingly complex methodologies available to model geometry and material properties of bones, these models still cannot accurately describe physical behaviour of the skeletal system unless the boundary conditions, especially muscular loading, are correct. Available in vivo measur...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2009.09.049
更新日期:2010-02-10 00:00:00
abstract::This study reports for the first time an estimation of the internal net joint forces and torques on adults' lower limbs and pelvis when walking in shallow water, taking into account the drag forces generated by the movement of their bodies in the water and the equivalent data when they walk on land. A force plate and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.01.017
更新日期:2011-04-07 00:00:00
abstract::Mathematical modelling of tendon thermodynamics predicted that the temperature of the central core of the equine superficial digital flexor tendon would plateau at 11 degrees C above the tendon surface temperature during a sustained gallop. A mean temperature differential (between tendon core and surface) of 5.4 (S.E....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90262-3
更新日期:1994-07-01 00:00:00
abstract::This paper discusses the manner in which random Gaussian errors affect the determination of body segment kinematics. For the process of modelling rigid body (RB) motion, three types of kinematic errors, input, measured and theoretical, are identified. These correspond to errors in: the determination of three-dimension...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00008-5
更新日期:1996-09-01 00:00:00
abstract::When stepping down from a height difference in ongoing gait, subjects are known to use a heel landing at small height differences and switch to toe landing for larger height differences. We hypothesized that in toe landing, the leading leg can perform more negative work, to control the momentum gained during the desce...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.05.022
更新日期:2008-08-07 00:00:00