Specimen dimensions influence the measurement of material properties in tendon fascicles.

Abstract:

:Stress, strain and modulus are regularly used to characterize material properties of tissue samples. However, when comparing results from different studies it is evident the reported material properties, particularly failure strains, vary hugely. The aim of our study was to characterize how and why specimen length and cross-sectional area (CSA) appear to influence failure stress, strain and modulus in fascicles from two functionally different tendons. Fascicles were dissected from five rat tails and five bovine foot extensors, their diameters determined by a laser micrometer, and loaded to failure at a range of grip-to-grip lengths. Strain to failure significantly decreased with increasing in specimen length in both rat and bovine fascicles, while modulus increased. Specimen length did not influence failure stress in rat tail fascicles, although in bovine fascicles it was significantly lower in the longer 40 mm specimens compared to 5 and 10mm specimens. The variations in failure strain and modulus with sample length could be predominantly explained by end-effects. However, it was also evident that strain fields along the sample length were highly variable and notably larger towards the ends of the sample than the mid-section even at distances in excess of 5mm from the gripping points. Failure strain, stress and modulus correlated significantly with CSA at certain specimen lengths. Our findings have implications for the mechanical testing of tendon tissue: while it is not always possible to control for fascicle length and/or CSA, these parameters have to be taken into account when comparing samples of different dimensions.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Legerlotz K,Riley GP,Screen HR

doi

10.1016/j.jbiomech.2010.04.040

subject

Has Abstract

pub_date

2010-08-26 00:00:00

pages

2274-80

issue

12

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(10)00267-8

journal_volume

43

pub_type

杂志文章
  • Ligament fibre recruitment at the human ankle joint complex in passive flexion.

    abstract::Knowledge of ligament fibre recruitment at the human ankle joint complex is a fundamental prerequisite for analysing mobility and stability. Previous experimental and modelling studies have shown that ankle motion must be guided by fibres within the calcaneofibular and tibiocalcaneal ligaments, which remain approximat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.043

    authors: Stagni R,Leardini A,Ensini A

    更新日期:2004-12-01 00:00:00

  • Reconstruction of proximal humeral fractures without screws using a reinforced bone substitute.

    abstract::Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110138

    authors: Cristofolini L,Ruspi ML,Marras D,Cavallo M,Guerra E

    更新日期:2021-01-22 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Direct perfusion measurements of cancellous bone anisotropic permeability.

    abstract::More extensive characterization of trabecular connectivity and intertrabecular space will be instrumental in understanding disease states and designing engineered bone. This project presents an experimental protocol to define the directional dependence of transport properties as measured from healthy cancellous bone w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00082-3

    authors: Kohles SS,Roberts JB,Upton ML,Wilson CG,Bonassar LJ,Schlichting AL

    更新日期:2001-09-01 00:00:00

  • Density of trunk tissues of young and medium age people.

    abstract::In this study the investigations made on about 50 trunk tissue densities are described. They were performed on ten cadavers of both sexes within 24 h of the moment of death. They were 20-40 yr old. The weight of each tissue was measured on a laboratory scale and the volume by placing the tissue in a pycnometer filled ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90360-f

    authors: Erdmann WS,Gos T

    更新日期:1990-01-01 00:00:00

  • Membrane permeability during pressure ulcer formation: A computational model of dynamic competition between cytoskeletal damage and repair.

    abstract::Pressure ulcers are debilitating wounds that arise frequently in people who have lost mobility. Mechanical stress, oxidative stress and ischemia-reperfusion injury are potential sources of damage during pressure ulcer formation, but cross-talk between these sources has rarely been investigated. In vitro experiments wi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.022

    authors: Jagannathan NS,Tucker-Kellogg L

    更新日期:2016-05-24 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus.

    abstract::Diabetes mellitus, which results from a failure of the endocrine system to control blood glucose levels within normal limits, affects approximately 15% of the population over the age of 65 in developed countries. Between 20-50% of people with diabetes for more than 10 years will experience symmetrical distal sensory n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(93)90077-r

    authors: Cavanagh PR,Simoneau GG,Ulbrecht JS

    更新日期:1993-01-01 00:00:00

  • The association between negative muscle work and pedaling rate.

    abstract::The objective of this research was to use a pedal force decomposition approach to quantify the amount of negative muscular crank torque generated by a group of competitive cyclists across a range of pedaling rates. We hypothesized that negative muscular crank torque increases at high pedaling rates as a result of the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00100-1

    authors: Neptune RR,Herzog W

    更新日期:1999-10-01 00:00:00

  • Torsional stiffness and strength of the proximal tibia are better predicted by finite element models than DXA or QCT.

    abstract::Individuals with spinal cord injury experience a rapid loss of bone mineral below the neurological lesion. The clinical consequence of this bone loss is a high rate of fracture around regions of the knee. The ability to predict the mechanical competence of bones at this location may serve as an important clinical tool...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.016

    authors: Edwards WB,Schnitzer TJ,Troy KL

    更新日期:2013-06-21 00:00:00

  • A new testing device for measuring gliding resistance and work of flexion in a digit.

    abstract::In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00300-7

    authors: Zhao C,Amadio PC,Berglund L,Zobitz ME,An KN

    更新日期:2003-02-01 00:00:00

  • Modeling the impact of concomitant aortic stenosis and coarctation of the aorta on left ventricular workload.

    abstract::Coarctation of the aorta (COA) is an obstruction of the aorta and is usually associated with bicuspid and tricuspid aortic valve stenosis (AS). When COA coexists with AS, the left ventricle (LV) is facing a double hemodynamic load: a valvular load plus a vascular load. The objective of this study was to develop a lump...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.08.001

    authors: Keshavarz-Motamed Z,Garcia J,Pibarot P,Larose E,Kadem L

    更新日期:2011-11-10 00:00:00

  • Measurement of whole-body vibration by double-pulsed holography.

    abstract::A technique for registering vibration and deformation patterns has been adapted for the measurement of whole-body vibration in humans. Double-exposure holographic interferometry produces three dimensional pictures of the body, allowing exact measurement of the subject's movement between the two pulses. In this study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90036-8

    authors: Wangenheim M,Holzmann P,Svensson LB

    更新日期:1984-01-01 00:00:00

  • The use of a single sacral marker method to approximate the centre of mass trajectory during treadmill running.

    abstract::The three-dimensional trajectory of the body's centre of mass (COM) is useful to determine a number of biomechanical outcomes in running research. Previous studies have used the COM to calculate measures such as overstriding, vertical stiffness, and vertical oscillation. The COM is traditionally computed using the seg...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109886

    authors: Napier C,Jiang X,MacLean CL,Menon C,Hunt MA

    更新日期:2020-07-17 00:00:00

  • On precision limits for derivatives numerically calculated from noisy data.

    abstract::This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified tha...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90082-3

    authors: Lanshammar H

    更新日期:1982-01-01 00:00:00

  • Evaluation of residual stresses due to bone callus growth: a computational study.

    abstract::Mechanical environment in callus is determinant for the evolution of bone healing. However, recent mechanobiological computational works have underestimated the effect that growth exerts on the mechanical environment of callus. In the present work, we computationally evaluate the significance of growth-induced stresse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.021

    authors: González-Torres LA,Gómez-Benito MJ,García-Aznar JM

    更新日期:2011-06-03 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • Understanding the fluid mechanics behind transverse wall shear stress.

    abstract::The patchy distribution of atherosclerosis within arteries is widely attributed to local variation in haemodynamic wall shear stress (WSS). A recently-introduced metric, the transverse wall shear stress (transWSS), which is the average over the cardiac cycle of WSS components perpendicular to the temporal mean WSS vec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.035

    authors: Mohamied Y,Sherwin SJ,Weinberg PD

    更新日期:2017-01-04 00:00:00

  • Application of strain and calibration of Förster Resonance Energy Transfer (FRET) emission for in vitro live cell response to cytoskeletal deformation.

    abstract::Cellular mechanotransduction is an integral part of many crucial physiological processes, but non-invasive tools for quantifying intracellular strain in vivo are not available for complex tissues such as bone. As a first step to address this gap, we have utilized a novel, non-invasive approach to quantify cellular str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.023

    authors: Knorr JM,Jackson J,Batie MR,Narmoneva DA,Jones DC

    更新日期:2016-10-03 00:00:00

  • Muscle activity reduces soft-tissue resonance at heel-strike during walking.

    abstract::Muscle activity has previously been suggested to minimize soft-tissue resonance which occurs at heel-strike during walking and running. If this concept were true then the greatest vibration damping would occur when the input force was closest to the resonant frequency of the soft-tissues at heel-strike. However, this ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(03)00216-1

    authors: Wakeling JM,Liphardt AM,Nigg BM

    更新日期:2003-12-01 00:00:00

  • The transmission of translational seat vibration to the head--II. Horizontal seat vibration.

    abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90170-4

    authors: Paddan GS,Griffin MJ

    更新日期:1988-01-01 00:00:00

  • Further evidence for the dynamic stability of intracranial saccular aneurysms.

    abstract::It has long been thought that intracranial saccular aneurysms enlarge and rupture because of mechanical instabilities. Recent nonlinear analyses suggest, however, that at least certain sub-classes of aneurysms do not exhibit quasi-static limit point instabilities or dynamic instabilities in response to periodic loadin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00083-6

    authors: David G,Humphrey JD

    更新日期:2003-08-01 00:00:00

  • Using smart garments to differentiate among normal and simulated abnormal gaits.

    abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2019.06.009

    authors: Mokhlespour Esfahani MI,Nussbaum MA

    更新日期:2019-08-27 00:00:00

  • Three-dimensional finite element analysis of glass-ceramic dental crowns.

    abstract::Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90008-q

    authors: Hojjatie B,Anusavice KJ

    更新日期:1990-01-01 00:00:00

  • Differences in stretch-shortening cycle and residual force enhancement between muscles.

    abstract::It has been suggested that cross bridge kinetics and residual force enhancement (RFE) affect force in the stretch-shortening cycle (SSC). Because cross bridge kinetics and titin isoforms, which are thought to be related to RFE, differ between muscles, the SSC effect may be also muscle-dependent. Thus, we compared the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110040

    authors: Fukutani A,Herzog W

    更新日期:2020-11-09 00:00:00

  • Simulation of quadrupedal locomotion using a rigid body model.

    abstract::Locomotion of the horse is simulated using a mathematical model based on rigid body dynamics. A general method to generate the equations of motion for a two-dimensional rigid body model with an arbitrary number of hinge joints is presented and a numerical solution method, restricted to tree-structured models, is descr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90182-6

    authors: van den Bogert AJ,Schamhardt HC,Crowe A

    更新日期:1989-01-01 00:00:00

  • Analytical modeling of the instantaneous maximal transvalvular pressure gradient in aortic stenosis.

    abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.013

    authors: Garcia D,Kadem L,Savéry D,Pibarot P,Durand LG

    更新日期:2006-01-01 00:00:00

  • Is a joint moment-based cost function associated with preferred cycling cadence?

    abstract::Eight experienced male cyclists (C), eight well-trained male runners (R), and eight less-trained male noncyclists (LT) were tested under multiple cadence and power output conditions to determine: (1) if the cadence at which lower extremity net joint moments are minimized (cost function cadence) was associated with pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00155-4

    authors: Marsh AP,Martin PE,Sanderson DJ

    更新日期:2000-02-01 00:00:00

  • Longitudinal strain of canine and porcine aortas.

    abstract::The in situ longitudinal strain of canine and porcine aortas was investigated. Marks of black water-resistant ink were placed on the aortas and the axial lengths between the marks were measured in situ and in vitro. When the aortas were cut, the retraction was measured and described by the stretch ratio, which is defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00091-h

    authors: Han HC,Fung YC

    更新日期:1995-05-01 00:00:00

  • Kinematic adjustability of unilateral external fixators for fracture reduction and alignment of axial dynamization.

    abstract::Bone fracture reduction and bone axial dynamization are important operations which effectiveness can be further enhanced by the use of a unilateral external fixator. By design, axial dynamization can be performed through reciprocating one of its translational joints. However, non-axial dynamization may occur after cor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.002

    authors: Ou YJ

    更新日期:2009-08-25 00:00:00