Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

Abstract:

:In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important factors for nanomechanical deflections of microcantilevers. In this paper, the biolayer immobilized on microcantilever is treated as a bar with a macroscopic elastic modulus on the basis of continuum mechanics viewpoints. In consideration of hydration force, screened electrostatic repulsion and conformational fluctuation in biolayers, load-deformation curves of dsDNA biolayers under axial compression are depicted with the help of the energy conservation law and a mesoscopic free energy presented by Strey et al. (1997, 1999) [Strey, H.H., Parsegian, V.A., Podgornik, R., 1997. Equation of state for DNA liquid crystals: fluctuation enhanced electrostatic double layer repulsion. Physical Review Letters 78, 895-898; Strey, H.H., Parsegian, V.A., Podgornik, R., 1999. Equation of state for polymer liquid crystals: theory and experiment. Physical Review E 59, 999-1008] from a liquid crystal theory. And the analytical relation between macroscopic Young's modulus of biolayers and nanoscopic geometrical properties of dsDNA, packing density, buffer salt solution concentration, etc. is also formulated.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Zhang NH,Chen JZ

doi

10.1016/j.jbiomech.2009.03.050

subject

Has Abstract

pub_date

2009-07-22 00:00:00

pages

1483-1487

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(09)00200-0

journal_volume

42

pub_type

杂志文章
  • Modification of spastic gait through mechanical damping.

    abstract::The effect of dissipative mechanical loads on spastic gait has been studied, to evaluate the feasibility of using mechanically damped orthoses to effect functional improvements in the gait of spastic patients. This concept is based on a hypothesis citing uninhibited, velocity-dependent stretch reflexes as a possible c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90278-7

    authors: Maki BE,Rosen MJ,Simon SR

    更新日期:1985-01-01 00:00:00

  • Mechanical and metabolic requirements for active lateral stabilization in human walking.

    abstract::Walking appears to be passively unstable in the lateral direction, requiring active feedback control for stability. The central nervous system may control stability by adjusting medio-lateral foot placement, but potentially with a metabolic cost. This cost increases with narrow steps and may affect the preferred step ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.06.002

    authors: Donelan JM,Shipman DW,Kram R,Kuo AD

    更新日期:2004-06-01 00:00:00

  • Exploring the regional disc bulge response of the cervical porcine intervertebral disc under varying loads and posture.

    abstract::Nerve compression due to intervertebral disc (IVD) bulging is a known mechanism for low back pain and typically occurs in the posterior region of the disc. Most in vitro studies are limited in the ability to quantify the magnitude of bulging on the posterior aspect of the disc due to the boney structures that occlude ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109713

    authors: Fewster KM,Noguchi M,Gooyers CE,Wong A,Callaghan JP

    更新日期:2020-05-07 00:00:00

  • Using directional statistics to test hypotheses regarding rigid body attitude: Comparison to univariate and multivariate Cardan angle tests.

    abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109976

    authors: Pataky TC,Challis JH

    更新日期:2020-10-09 00:00:00

  • Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

    abstract::The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.027

    authors: Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

    更新日期:2006-01-01 00:00:00

  • Pressure distribution over the palm region during forward falls on the outstretched hands.

    abstract::Falls on the outstretched hands are the cause of over 90% of wrist fractures, yet little is known about bone loading during this event. We tested how the magnitude and distribution of pressure over the palm region during a forward fall is affected by foam padding (simulating a glove) and arm configuration, and by the ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.011

    authors: Choi WJ,Robinovitch SN

    更新日期:2011-02-03 00:00:00

  • The knee joint center of rotation is predominantly on the lateral side during normal walking.

    abstract::The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees duri...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.013

    authors: Koo S,Andriacchi TP

    更新日期:2008-01-01 00:00:00

  • A numerical simulation of mechanical heart valve closure fluid dynamics.

    abstract::A computational fluid dynamics model for the analysis of the bileaflet mechanical heart valve closure process is presented. The objective of the study is to demonstrate the ability of the numerical model to simulate the leaflet motion during the closing phase in order to investigate the closure fluid dynamics and to e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00056-8

    authors: Lai YG,Chandran KB,Lemmon J

    更新日期:2002-07-01 00:00:00

  • Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions.

    abstract::Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction of density in bone surrounding the implant. This effect can be related to the weakness of the implant fixation, which can promote implant loosening. Several studies describe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.048

    authors: Meireles S,Completo A,António Simões J,Flores P

    更新日期:2010-02-10 00:00:00

  • Walking speed and spatiotemporal step mean measures are reliable during feedback-controlled treadmill walking; however, spatiotemporal step variability is not reliable.

    abstract::The purpose of the study was to compare the effects of a feedback-controlled treadmill (FeedbackTM) to a traditional fixed-speed treadmill (FixedTM) on spatiotemporal gait means, variability, and dynamics. The study also examined inter-session reliability when using the FeedbackTM. Ten young adults walked on the Feedb...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.051

    authors: Wiens C,Denton W,Schieber MN,Hartley R,Marmelat V,Myers SA,Yentes JM

    更新日期:2019-01-23 00:00:00

  • Force response of the fingertip pulp to repeated compression--effects of loading rate, loading angle and anthropometry.

    abstract::Repeated loading of the fingertips has been postulated to contribute to tendon and nerve disorders at the wrist during activities associated with prolonged fingertip loading such as typing. To fully understand the pathomechanics of these soft tissue disorders, the role of the fingertip pulp in attenuating the applied ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00065-1

    authors: Serina ER,Mote CD Jr,Rempel D

    更新日期:1997-10-01 00:00:00

  • A little bit faster: Lower extremity joint kinematics and kinetics as recreational runners achieve faster speeds.

    abstract::There appears a linear relationship between small increases in running speed and cardiovascular health benefits. Encouraging or coaching recreational runners to increase their running speed to derive these health benefits might be more effective if their joint level kinematic and kinetic strategy was understood. The a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.010

    authors: Orendurff MS,Kobayashi T,Tulchin-Francis K,Tullock AMH,Villarosa C,Chan C,Kraus E,Strike S

    更新日期:2018-04-11 00:00:00

  • Effects of femoral component placement on the balancing of a total knee at surgery.

    abstract::Misalignment and soft-tissue imbalance in total knee arthroplasty (TKA) can cause discomfort, pain, inadequate motion and instability that may require revision surgery. Balancing can be defined as equal collateral ligament tensions or equal medial and lateral compartmental forces during the flexion range. Our goal was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.056

    authors: Zapata G,Sanz-Pena I,Verstraete M,Walker PS

    更新日期:2019-03-27 00:00:00

  • Predictive equations to estimate spinal loads in symmetric lifting tasks.

    abstract::Response surface methodology is used to establish robust and user-friendly predictive equations that relate responses of a complex detailed trunk finite element biomechanical model to its input variables during sagittal symmetric static lifting activities. Four input variables (thorax flexion angle, lumbar/pelvis rati...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.028

    authors: Arjmand N,Plamondon A,Shirazi-Adl A,Larivière C,Parnianpour M

    更新日期:2011-01-04 00:00:00

  • Decomposition of superimposed ground reaction forces into left and right force profiles.

    abstract::The process of collecting ground reaction force data by mounting a forceplate beneath a treadmill belt has the advantage that numerous walking trials can be analyzed without the problem of subjects 'targeting' their footsteps. However, a potential problem is that the measured forces represent a summation of bilateral ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90020-f

    authors: Davis BL,Cavanagh PR

    更新日期:1993-04-01 00:00:00

  • Effects of lumbo-pelvic rhythm on trunk muscle forces and disc loads during forward flexion: A combined musculoskeletal and finite element simulation study.

    abstract::Previous in-vivo studies suggest that the ratio of total lumbar rotation over pelvic rotation (lumbo-pelvic rhythm) during trunk sagittal movement is essential to evaluate spinal loads and discriminate between low back pain and asymptomatic population. Similarly, there is also evidence that the lumbo-pelvic rhythm is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.009

    authors: Liu T,Khalaf K,Adeeb S,El-Rich M

    更新日期:2019-01-03 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Impact-induced osteochondral fracture in the tibial plateau.

    abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.033

    authors: Thambyah A,Shim VP,Chong LM,Lee VS

    更新日期:2008-01-01 00:00:00

  • A model of surfactant-induced surface tension effects on the parenchymal tethering of pulmonary airways.

    abstract::We developed a computational model of lung parenchyma, which is comprised of individual alveolar chamber models. Each alveolus is modeled by a truncated octahedron. Considering the force balance between the elastin and collagen fibers laying on the alveolar membrane and the pressures acting on the membrane, we compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.031

    authors: Fujioka H,Halpern D,Gaver DP 3rd

    更新日期:2013-01-18 00:00:00

  • Crushed bone grafts and a collagen membrane are not suitable for enhancing cartilage quality in the regeneration of osteochondral defects--an in vivo study in sheep.

    abstract::Hyaline joint cartilage has only a limited potential for self-repair. Some of the published techniques for osteochondral defect therapy try to improve that potential. In this study, it was hypothesised that one of those surgical techniques, the crushed transplanted bone graft together with a collagen membrane, acceler...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.021

    authors: Schell H,Lienau J,Kleemann RU,Schlichting K,Taylor WR,Weiler A,Duda GN

    更新日期:2007-01-01 00:00:00

  • A fully nonlinear viscohyperelastic model for the brain tissue applicable to dynamic rates.

    abstract::Understanding the mechanical response of the brain to external loadings is of critical importance in investigating the pathological conditions of this tissue during injurious conditions. Such injurious loadings may occur at high rates, for example among others, during road traffic or sport accidents, falls, or due to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.007

    authors: Samadi-Dooki A,Voyiadjis GZ

    更新日期:2019-02-14 00:00:00

  • Analysis of a femoral hip prosthesis designed to reduce stress shielding.

    abstract::The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the ch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00110-x

    authors: Joshi MG,Advani SG,Miller F,Santare MH

    更新日期:2000-12-01 00:00:00

  • Passive and active muscle stiffness in plantar flexors of long distance runners.

    abstract::The aim of the present study was to compare passive and active muscle stiffness and tendon stiffness between long distance runners and untrained men. Twenty long distance runners and 24 untrained men participated in this study. Active muscle stiffness in the medial gastrocnemius muscle was calculated according to chan...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.012

    authors: Kubo K,Miyazaki D,Yamada K,Yata H,Shimoju S,Tsunoda N

    更新日期:2015-07-16 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • Site specific inelasticity of arterial tissue.

    abstract::Understanding the mechanical behaviour of arterial tissue is vital to the development and analysis of medical devices targeting diseased vessels. During angioplasty and stenting, stress softening and permanent deformation of the vessel wall occur during implantation of the device, however little data exists on the ine...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.026

    authors: Maher E,Early M,Creane A,Lally C,Kelly DJ

    更新日期:2012-05-11 00:00:00

  • Virtually optimized insoles for offloading the diabetic foot: A randomized crossover study.

    abstract::Integration of objective biomechanical measures of foot function into the design process for insoles has been shown to provide enhanced plantar tissue protection for individuals at-risk of plantar ulceration. The use of virtual simulations utilizing numerical modeling techniques offers a potential approach to further ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jbiomech.2017.06.028

    authors: Telfer S,Woodburn J,Collier A,Cavanagh PR

    更新日期:2017-07-26 00:00:00

  • Velocities and stress levels of axisymmetric, azimuthal flow within the toroidal rotary seal of the IBM 2997 continuous flow cell separator and the implications.

    abstract::Continuous flow blood fraction separators are used to facilitate the removal of specific blood components for donation or for certain medical procedures. Problems with one such device, the IBM 2997 Blood Processor, have been noted in a number of independent investigations. A key feature of this particular unit is a ce...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90163-6

    authors: Harvey CB,O'Rear EA

    更新日期:1986-01-01 00:00:00

  • Biomechanical evaluation of the docking nail concept in periprosthetic fracture fixation around a stemmed total knee arthroplasty.

    abstract::Intramedullary femoral nails provide an ideal mechanical axis for periprosthetic fracture fixation. Slotted nails allow a connection to a total knee arthroplasty (TKA) stem. This study aims to compare implant and construct stiffness, interfragmentary movement and cycles to failure between an antegrade slotted femoral ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110109

    authors: Lenz M,Acklin YP,Kasper LA,Mischler D,Varga P,Zderic I,Gehweiler D,Klos K,Gueorguiev B,Stoffel K

    更新日期:2021-01-22 00:00:00

  • Biomechanical analysis of fluid percussion model of brain injury.

    abstract::Fluid percussion injury (FPI) is a widely used experimental model for studying traumatic brain injury (TBI). However, little is known about how the brain mechanically responds to fluid impacts and how the mechanical pressures/strains of the brain correlate to subsequent brain damage for rodents during FPI. Hence, we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.004

    authors: Mao H,Lu L,Bian K,Clausen F,Colgan N,Gilchrist M

    更新日期:2018-08-22 00:00:00

  • Three-dimensional finite element analysis of glass-ceramic dental crowns.

    abstract::Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90008-q

    authors: Hojjatie B,Anusavice KJ

    更新日期:1990-01-01 00:00:00