Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.

Abstract:

:The present work displayed the first quantitative data of forces acting on tendons and pulleys during specific sport-climbing grip techniques. A three-dimensional static biomechanical model was used to estimate finger muscle tendon and pulley forces during the "slope" and the "crimp" grip. In the slope grip the finger joints are flexed, and in the crimp grip the distal interphalangeal (DIP) joint is hyperextended while the other joints are flexed. The tendons of the flexor digitorum profundus and superficialis (FDP and FDS), the extensor digitorum communis (EDC), the ulnar and radial interosseus (UI and RI), the lumbrical muscle (LU) and two annular pulleys (A2 and A4) were considered in the model. For the crimp grip in equilibrium conditions, a passive moment for the DIP joint was taken into account in the biomechanical model. This moment was quantified by relating the FDP intramuscular electromyogram (EMG) to the DIP joint external moment. Its intensity was estimated at a quarter of the external moment. The involvement of this parameter in the moment equilibrium equation for the DIP joint is thus essential. The FDP-to-FDS tendon-force ratio was 1.75:1 in the crimp grip and 0.88:1 in the slope grip. This result showed that the FDP was the prime finger flexor in the crimp grip, whereas the tendon tensions were equally distributed between the FDP and FDS tendons in the slope grip. The forces acting on the pulleys were 36 times lower for A2 in the slope grip than in the crimp grip, while the forces acting on A4 were 4 times lower. This current work provides both an experimental procedure and a biomechanical model that allows estimation of tendon tensions and pulley forces crucial for the knowledge about finger injuries in sport climbing.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Vigouroux L,Quaine F,Labarre-Vila A,Moutet F

doi

10.1016/j.jbiomech.2005.08.027

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

2583-92

issue

14

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(05)00403-3

journal_volume

39

pub_type

杂志文章
  • A survey of micro-finite element analysis for clinical assessment of bone strength: the first decade.

    abstract::Micro-Finite Element (micro-FE) analysis is now widely used in biomedical research as a tool to derive bone mechanical properties as they relate to its microstructure. With the development of in vivo high-resolution peripheral quantitative CT (HR-pQCT) scanners, it can now be applied to analyze bone in-vivo in the per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.024

    authors: van Rietbergen B,Ito K

    更新日期:2015-03-18 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Estimating the gravity induced three dimensional deformation of the breast.

    abstract::As human breast tissue is continuously deformed by gravity, it is difficult to identify the non-loaded neutral breast position from which to take measurements. To estimate the neutral nipple position, this study proposed a simple novel method to counteract the three dimensional effect of gravity on the breast using th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.012

    authors: Mills C,Sanchez A,Scurr J

    更新日期:2016-12-08 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • Macroscopic anisotropic bone material properties in children with severe osteogenesis imperfecta.

    abstract::Children with severe osteogenesis imperfecta (OI) typically experience numerous fractures and progressive skeletal deformities over their lifetime. Recent studies proposed finite element models to assess fracture risk and guide clinicians in determining appropriate intervention in children with OI, but lack of appropr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.003

    authors: Albert C,Jameson J,Tarima S,Smith P,Harris G

    更新日期:2017-11-07 00:00:00

  • Tensile damage and its effects on cortical bone.

    abstract::Plexiform bovine bone samples are repeatedly loaded in tension along their longitudinal axis. In order to induce damage in the bone tissue, bone samples are loaded past their yield point. Half of the bone samples from the damaged group were stored in saline to allow for viscoelastic recovery while the others were deca...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00169-6

    authors: Kotha SP,Guzelsu N

    更新日期:2003-11-01 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • Effects of extracellular fiber architecture on cell membrane shear stress in a 3D fibrous matrix.

    abstract::Interstitial fluid flow has been shown to affect the organization and behavior of cells in 3D environments in vivo and in vitro, yet the forces driving such responses are not clear. Due to the complex architecture of the extracellular matrix (ECM) and the difficulty of measuring fluid flow near cells embedded in it, t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.023

    authors: Pedersen JA,Boschetti F,Swartz MA

    更新日期:2007-01-01 00:00:00

  • Analysis of swimmers' velocity during the underwater gliding motion following grab start.

    abstract::The purpose of this study was to determine the swimmers' loss of speed during the underwater gliding motion of a grab start. This study also set out to determine the kinematical variables influencing this loss of speed. Eight French national-level swimmers participated in this study. The swimmers were filmed using 4 m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.032

    authors: Elipot M,Hellard P,Taïar R,Boissière E,Rey JL,Lecat S,Houel N

    更新日期:2009-06-19 00:00:00

  • Effect of temperature on residual force enhancement in single skeletal muscle fibers.

    abstract::It is well accepted that the steady-state isometric force following active stretching of a muscle is greater than the steady-state isometric force obtained in a purely isometric contraction at the same length. This property of skeletal muscle has been called residual force enhancement (FE). Despite decades of research...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.007

    authors: Lee EJ,Herzog W

    更新日期:2008-08-28 00:00:00

  • Improvement of upper extremity kinematics estimation using a subject-specific forearm model implemented in a kinematic chain.

    abstract::Human movement reconstruction is still difficult due to noise generated by the use of skin markers. The a priori definition of a kinematic chain associated with a global optimisation method allows reducing these deleterious effects. When dealing with the forearm, this approach can be improved by personalising the two ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.01.029

    authors: Fohanno V,Lacouture P,Colloud F

    更新日期:2013-04-05 00:00:00

  • Hydro-mechanical coupling in the periodontal ligament: a porohyperelastic finite element model.

    abstract::Harmonic tension-compression tests at 0.1, 0.5 and 1 Hz on hydrated bovine periodontal ligament (PDL) were numerically simulated. The process was modeled by finite elements (FE) within the framework of poromechanics, with the objective of isolating the contributions of the solid- and fluid phases. The solid matrix was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.019

    authors: Bergomi M,Cugnoni J,Galli M,Botsis J,Belser UC,Wiskott HW

    更新日期:2011-01-04 00:00:00

  • Differences between measured and resultant joint moments during isometric contractions at the ankle joint.

    abstract::The purpose of this study was to examine two hypotheses: (a) during voluntary and electrically induced isometric contractions the moments measured at the dynamometer are different from the resultant moments in the same plane around the ankle joint and (b) at a given resultant moment during electrically induced isometr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.04.027

    authors: Arampatzis A,Morey-Klapsing G,Karamanidis K,DeMonte G,Stafilidis S,Brüggemann GP

    更新日期:2005-04-01 00:00:00

  • Forefoot structural predictors of plantar pressures during walking in people with diabetes and peripheral neuropathy.

    abstract::Various foot structures are thought to influence forefoot plantar pressures during walking. High peak plantar pressures (PPP) during walking in people with diabetes mellitus (DM) and peripheral neuropathy (PN) can cause skin breakdown. The question addressed by this study is "What are the primary forefoot structural f...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(03)00078-2

    authors: Mueller MJ,Hastings M,Commean PK,Smith KE,Pilgram TK,Robertson D,Johnson J

    更新日期:2003-07-01 00:00:00

  • Functional imaging using computational fluid dynamics to predict treatment success of mandibular advancement devices in sleep-disordered breathing.

    abstract::Mandibular advancement devices (MADs) have emerged as a popular alternative for the treatment of sleep-disordered breathing. These devices bring the mandibula forward in order to increase upper airway (UA) volume and prevent total UA collapse during sleep. However, the precise mechanism of action appears to be quite c...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2007.06.022

    authors: De Backer JW,Vanderveken OM,Vos WG,Devolder A,Verhulst SL,Verbraecken JA,Parizel PM,Braem MJ,Van de Heyning PH,De Backer WA

    更新日期:2007-01-01 00:00:00

  • Gait variability magnitude but not structure is altered in essential tremor.

    abstract::Essential tremor (ET) is a common tremor disorder affecting postural/action tremor of the upper extremities and midline. Recent research revealed a cerebellar-like deficit during tandem gait in persons with ET, though spatiotemporal variability during normal gait in ET has been relatively ignored. The first purpose of...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.07.039

    authors: Roemmich RT,Zeilman PR,Vaillancourt DE,Okun MS,Hass CJ

    更新日期:2013-10-18 00:00:00

  • Interpersonal coordination analysis of tennis players from different levels during official matches.

    abstract::The purpose of this study was to assess the interpersonal coordination during official male tennis matches in players of different skill levels. Players' trajectories of three levels (Juvenile, ATP-Future, ATP-250) were obtained using video-based tracking system. A vector coding technique was applied to obtain players...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.036

    authors: Pereira TJC,van Emmerik REA,Misuta MS,Barros RML,Moura FA

    更新日期:2018-01-23 00:00:00

  • Dynamic interactions between lumbar intervertebral motion segments during forward bending and return.

    abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109603

    authors: Breen A,Breen A

    更新日期:2020-03-26 00:00:00

  • Calf muscle moment, work and efficiency in level walking; role of series elasticity.

    abstract::Moment and work of the human calf muscles in level walking were determined by means of an EMG to force processor, based on a muscle analogue (Hof and Van den Berg (1981) J. Biomechanics, 14, 747-758, 759-770, 771-785, 787-792). Nine subjects (four women, five men) walked on a level treadmill at speeds between 0.5 and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90067-2

    authors: Hof AL,Geelen BA,Van den Berg J

    更新日期:1983-01-01 00:00:00

  • Impact-induced osteochondral fracture in the tibial plateau.

    abstract::In this study, human tibia plateaus with the meniscus removed were impacted on various regions of the plateau surface via a drop test using a 5mm indenter. Osteochondral blocks containing the failure site were then extracted, chemically fixed, dehydrated, gold-particle coated, and sent for X-ray micro-CT imaging to ob...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.033

    authors: Thambyah A,Shim VP,Chong LM,Lee VS

    更新日期:2008-01-01 00:00:00

  • T2 relaxation time measurements in tibiotalar cartilage after barefoot running and its relationship to ankle biomechanics.

    abstract::The influence of ankle kinematics and plantar pressure from mid-range barefoot running on T2 relaxation times of tibiotalar cartilage is unknown. This study aimed to quantitatively evaluate the T2 relaxation time of tibiotalar cartilage and ankle biomechanics following 5 km barefoot running. Twenty healthy runners (wh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.046

    authors: Kyung Kim H,Fernandez J,Logan C,Tarr GP,Doyle A,Mirjalili SA

    更新日期:2019-06-11 00:00:00

  • Fracture toughness and work of fracture of hydrated, dehydrated, and ashed bovine bone.

    abstract::Bone, a tri-phase composite, consists of nano-sized apatite minerals, an organic component, and water. Heat-treated bovine cortical bone has been proposed as a candidate for void-filling bone substitute. However, the toughness of heat-treated bone is not yet fully studied. Fracture toughness (K(c)) and work of fractur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.037

    authors: Yan J,Daga A,Kumar R,Mecholsky JJ

    更新日期:2008-01-01 00:00:00

  • A physiological approach to the simulation of bone remodeling as a self-organizational control process.

    abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90049-3

    authors: Mullender MG,Huiskes R,Weinans H

    更新日期:1994-11-01 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00

  • The Cybermouse: a simple method of describing the trajectory of the human mandible in three dimensions.

    abstract::A simple method of recording the three-dimensional movements of the mandible together with up to 10 channels of other physiological data is described. The system is based on a commercially available device, the Cybermouse (IPC, Freemont, CA, U.S.A.), consisting of a lightweight ultrasonic emitter which can be attached...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00012-2

    authors: Prinz JF

    更新日期:1997-06-01 00:00:00

  • Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    abstract::Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.011

    authors: Zheng D,Murray A

    更新日期:2009-05-29 00:00:00

  • Effects of damage in the articular surface on the cartilage response to injurious compression in vitro.

    abstract::Macroscopic structural damage to the cartilage articular surface can occur due to slicing in surgery, cracking in mechanical trauma, or fibrillation in early stage osteoarthrosis. These alterations may render cartilage matrix and chondrocytes susceptible to subsequent mechanical injury and contribute to progression of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.01.026

    authors: Morel V,Berutto C,Quinn TM

    更新日期:2006-01-01 00:00:00

  • Displacement analysis of the temporomandibular condyle from magnetic resonance images.

    abstract::A technique was developed to investigate the condylar displacement of the human temporomandibular joint. Condylar displacement was analyzed from magnetic resonance images of the joint. Fourteen static images were obtained during incremental jaw closure. Landmarks were identified on the magnetic resonance images and re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90096-w

    authors: Chen J,Buckwalter K

    更新日期:1993-12-01 00:00:00

  • A potential role of smooth muscle tone in early hypertension: a theoretical study.

    abstract::A conspicuous long-term consequence of hypertension is a thickening of the arterial wall, which many suggest returns the circumferential wall stress toward its normal value. This thickening results from an increase in smooth muscle and extracellular matrix, with the associated growth and remodeling processes depending...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00178-7

    authors: Humphrey JD,Wilson E

    更新日期:2003-11-01 00:00:00

  • Enhanced global mathematical model for studying cerebral venous blood flow.

    abstract::Here we extend the global, closed-loop, mathematical model for the cardiovascular system in Müller and Toro (2014) to account for fundamental mechanisms affecting cerebral venous haemodynamics: the interaction between intracranial pressure and cerebral vasculature and the Starling-resistor like behaviour of intracrani...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.08.005

    authors: Müller LO,Toro EF

    更新日期:2014-10-17 00:00:00