Dynamic interactions between lumbar intervertebral motion segments during forward bending and return.

Abstract:

:Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels during an active weight bearing flexion and return protocol in chronic, non-specific low back pain (CNSLBP) patients and controls using quantitative fluoroscopy (QF). Eight CNSLBP patients received QF during guided standing lumbar flexion. Dynamic motion sharing of segments from L2 to S1 were calculated and analysed for interactions between levels. Eight asymptomatic controls were then matched to the 8 patients for age and sex and their motion sharing patterns compared. Share of intersegmental motion was found to be consistently highest at L2-L3 and L3-L4 and lowest at L5-S1 throughout the motion in both groups, with the exception of maximum flexion where L4-L5 received the greatest share. Change in motion sharing occurred throughout the flexion and return motion paths in both participant groups but tended to vary more at L4-L5 in patients (p < 0.05). In patients, L5-S1 provided less angular range (p < 0.05) and contributed less at maximum bend (p < 0.05), while L3-L4, on average over the bending sequence, provided a greater share of motion (p < 0.05). Intervertebral motion sharing inequality is therefore a normal feature during lumbar flexion. However, in patients, inequality was more pronounced, and variability of motion share at some levels increased. These effects may result from differences in muscular contraction or in the mechanical properties of the disc.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Breen A,Breen A

doi

10.1016/j.jbiomech.2020.109603

subject

Has Abstract

pub_date

2020-03-26 00:00:00

pages

109603

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(20)30006-3

journal_volume

102

pub_type

杂志文章
  • Maximum height and minimum time vertical jumping.

    abstract::The performance criterion in maximum vertical jumping has typically been assumed to simply raise the center of mass as high as possible. In many sporting activities minimizing movement time during the jump is likely also critical to successful performance. The purpose of this study was to examine maximum height jumps ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.021

    authors: Domire ZJ,Challis JH

    更新日期:2015-08-20 00:00:00

  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • Gait dynamics on an inclined walkway.

    abstract:OBJECTIVE:This paper documents research that quantifies and describes the biomechanics of normal gait on inclined surfaces. DESIGN:Experimental, investigative. BACKGROUND:It is necessary to walk on inclined surfaces to negotiate the natural and built environments. Little research has been conducted on the biomechanic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.07.025

    authors: McIntosh AS,Beatty KT,Dwan LN,Vickers DR

    更新日期:2006-01-01 00:00:00

  • Effects of femoral component placement on the balancing of a total knee at surgery.

    abstract::Misalignment and soft-tissue imbalance in total knee arthroplasty (TKA) can cause discomfort, pain, inadequate motion and instability that may require revision surgery. Balancing can be defined as equal collateral ligament tensions or equal medial and lateral compartmental forces during the flexion range. Our goal was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.056

    authors: Zapata G,Sanz-Pena I,Verstraete M,Walker PS

    更新日期:2019-03-27 00:00:00

  • Effect of the "squat protective response" on impact velocity during backward falls.

    abstract::Risk for injury during a fall depends on the position and velocity of the body segments at the moment of impact. One technique for reducing impact velocity is to absorb energy in the lower extremity muscles during descent, as occurs during squatting or sitting. However, the protective value of this response may depend...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2003.12.015

    authors: Robinovitch SN,Brumer R,Maurer J

    更新日期:2004-09-01 00:00:00

  • Body segments decoupling in sitting: control of body posture from automatic chair adjustments.

    abstract:BACKGROUND:Individuals who cannot functionally reposition themselves adopt a passive body posture and suffer from physical discomfort in long-term sitting. To regulate body load and to prevent sitting related mobility problems, proper posture control is important. The inability to reposition underlines the importance f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.017

    authors: van Geffen P,Molier BI,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-12-05 00:00:00

  • Musculoskeletal stiffness changes linearly in response to increasing load during walking gait.

    abstract::Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a tread...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.046

    authors: Caron RR,Lewis CL,Saltzman E,Wagenaar RC,Holt KG

    更新日期:2015-04-13 00:00:00

  • Patient-specific bone modelling and remodelling simulation of hypoparathyroidism based on human iliac crest biopsies.

    abstract::We previously developed a load-adaptive bone modelling and remodelling simulation model that can predict changes in the bone micro-architecture as a result of changes in mechanical loading or cell activity. In combination with a novel algorithm to estimate loading conditions, this offers the possibility for patient-sp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.031

    authors: Christen P,Ito K,Müller R,Rubin MR,Dempster DW,Bilezikian JP,van Rietbergen B

    更新日期:2012-09-21 00:00:00

  • A thermodynamically consistent constitutive equation for the elastic force-length relation of soft biological materials.

    abstract::Starting from the laws of thermodynamics of reversible processes, a temperature-dependent constitutive equation is derived for the elastic force-length relation of soft biological tissues. These tissues are composed of a network of fibres (mainly collagen). The equation is based on a model which uses a simplified two-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90222-4

    authors: Maes M,Vanhuyse VJ,Decraemer WF,Raman ER

    更新日期:1989-01-01 00:00:00

  • Biotribology of a mobile bearing posterior stabilised knee design--effect of motion restraint on wear, tibio-femoral kinematics and particles.

    abstract::The objective of our study was to evaluate the impact of a biphaseal anterior-posterior (AP) and internal-external (IE) motion restraint system on the wear behaviour, tibio-femoral kinematics and particle release of a mobile bearing posterior stabilised knee design in comparison to the widely used linear restraint. in...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.020

    authors: Grupp TM,Schroeder C,Kyun Kim T,Miehlke RK,Fritz B,Jansson V,Utzschneider S

    更新日期:2014-07-18 00:00:00

  • A new approach for surface fitting method of articular joint surfaces.

    abstract::The application of joint contact mechanics requires a precise configuration of the joint surfaces. B-Spline, and NURBS have been widely used to model joint surfaces, but because these formulations use a structured data set provided by a rectangular net first, then a grid, there is a limit to the accuracy of the models...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.01.009

    authors: Hirokawa S,Ueki T,Ohtsuki A

    更新日期:2004-10-01 00:00:00

  • Studies of human locomotion: past, present and future.

    abstract::The study of human locomotion and its applications are examined from a historical viewpoint. Several critical steps in the advancement of the discipline are considered in the context of addressing a particular need to answer fundamental questions regarding the process of human locomotion. In addition, changes in the m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/s0021-9290(00)00061-0

    authors: Andriacchi TP,Alexander EJ

    更新日期:2000-10-01 00:00:00

  • Effects of broad frequency vibration on cultured osteoblasts.

    abstract::Bone is subjected in vivo to both high amplitude, low frequency strain, incurred by locomotion, and to low amplitude, broad frequency strain. The biological effects of low amplitude, broad frequency strain are poorly understood. To evaluate the effects of low amplitude strains ranging in frequency from 0 to 50 Hz on o...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00245-2

    authors: Tanaka SM,Li J,Duncan RL,Yokota H,Burr DB,Turner CH

    更新日期:2003-01-01 00:00:00

  • Motor unit acceleration maps and interference mechanomyographic distribution.

    abstract::The study analyses the two-dimensional distribution of surface mechanomyographic (MMG) signal generated by the activation of single motor units located in three transverse positions in the tibialis anterior muscle. In 12 healthy volunteers, surface MMG signals were recorded from the tibialis anterior muscle with a 3 x...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.007

    authors: Farina D,Li X,Madeleine P

    更新日期:2008-09-18 00:00:00

  • An activatable molecular spring reduces muscle tearing during extreme stretching.

    abstract::The purpose of this study was to determine failure stresses and failure lengths of actively and passively stretched myofibrils. As expected, myofibrils failed at average sarcomere lengths (about 6-7μm) that vastly exceeded sarcomere lengths at which actin-myosin filament overlap ceases to exist (4μm) and thus actin-my...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.07.016

    authors: Leonard TR,Joumaa V,Herzog W

    更新日期:2010-11-16 00:00:00

  • Upper limb joint kinetics during manual wheelchair propulsion in patients with different levels of spinal cord injury.

    abstract::The purpose of this study was to compare the forces and moments of the whole upper limb, analyzing forces and moments at the shoulder, elbow and wrist joints simultaneously during manual wheelchair propulsion of persons with different levels of spinal cord injury (SCI) on a treadmill. Fifty-one people participated in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.021

    authors: Gil-Agudo A,Del Ama-Espinosa A,Pérez-Rizo E,Pérez-Nombela S,Pablo Rodríguez-Rodríguez L

    更新日期:2010-09-17 00:00:00

  • Normalization of joint moments during gait: a comparison of two techniques.

    abstract::Joint moments are commonly used to characterize gait. Factors like height and weight influence these moments. This study determined which of two commonly used normalization methods, body mass or body weight times height, most reduced the effects of height and weight on peak hip, knee, and ankle external moments during...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0021-9290(02)00433-5

    authors: Moisio KC,Sumner DR,Shott S,Hurwitz DE

    更新日期:2003-04-01 00:00:00

  • Bisphosphonate treatment in the oim mouse model alters bone modeling during growth.

    abstract::Osteogenesis imperfecta (OI) is a heritable disease, which results from an abnormal amount or structure of Type I collagen. Bisphosphonates, a class of synthetic antiresorptive drugs, used in osteoporosis management, are also used to decrease fracture incidence and improve quality of life in children with OI. In this ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.028

    authors: Rao SH,Evans KD,Oberbauer AM,Martin RB

    更新日期:2008-12-05 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Two mathematical models explain the variation in cystometrograms of obstructed urinary bladders.

    abstract::Overdistension of the urinary bladder, secondary to outlet obstruction, causes cellular changes in the bladder wall, including hypertrophy of the smooth muscle cells, which increase bladder mass. To investigate the effects of increased mass on the cystometrogram (CMG), we have developed two mathematical models. In the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:

    authors: Damaser MS,Lehman SL

    更新日期:1996-12-01 00:00:00

  • Scapular kinematic is altered after electromyography biofeedback training.

    abstract::Electromyography (EMG) biofeedback training affords patients a better sense of the different muscle activation patterns involved in the movement of the shoulder girdle. It is important to address scapular kinematics with labourers who have daily routines involving large amounts of lifting at shoulder level or higher. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.04.036

    authors: San Juan JG,Gunderson SR,Kane-Ronning K,Suprak DN

    更新日期:2016-06-14 00:00:00

  • A volumetric model for growth of arterial walls with arbitrary geometry and loads.

    abstract::Stress and deformation in arterial wall tissue are factors which may influence significantly its response and evolution. In this work we develop models based on nonlinear elasticity and finite element numerical solutions for the mechanical behaviour and the remodelling of the soft tissue of arteries, including anisotr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.002

    authors: Rodríguez J,Goicolea JM,Gabaldón F

    更新日期:2007-01-01 00:00:00

  • Non-invasive prediction of skin flap shrinkage: a new concept based on animal experimental evidence.

    abstract::A non-invasive, in vivo method has been developed to predict the skin flap shrinkage (retraction) following a harvest. It involves the use of a novel custom-designed extensometer to measure the force-displacement behaviour of skin and subsequent data analysis to estimate the shrinkage. In validation experiments perfor...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.03.012

    authors: Lim KH,Jeyapalina S,Ho HN,Chew CM,Chen PC,Teo CL,Lim BH

    更新日期:2008-01-01 00:00:00

  • Validation of an ambient system for the measurement of gait parameters.

    abstract::Fall risk in elderly people is usually assessed using clinical tests. These tests consist in a subjective evaluation of gait performed by healthcare professionals, most of the time shortly after the first fall occurrence. We propose to complement this one-time, subjective evaluation, by a more quantitative analysis of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.024

    authors: Dubois A,Bresciani JP

    更新日期:2018-03-01 00:00:00

  • Digital volume correlation and micro-CT: An in-vitro technique for measuring full-field interface micromotion around polyethylene implants.

    abstract::Micromotion around implants is commonly measured using displacement-sensor techniques. Due to the limitations of these techniques, an alternative approach (DVC-μCT) using digital volume correlation (DVC) and micro-CT (μCT) was developed in this study. The validation consisted of evaluating DVC-μCT based micromotion ag...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.024

    authors: Sukjamsri C,Geraldes DM,Gregory T,Ahmed F,Hollis D,Schenk S,Amis A,Emery R,Hansen U

    更新日期:2015-09-18 00:00:00

  • Non-invasive determination of cartilage thickness throughout joint surfaces using magnetic resonance imaging.

    abstract::Data on articular cartilage thickness in the living are important for the design for computer models, aimed at preoperatively assessing the effect of surgical procedures on joint contact and load transmission, and for the calculation of cartilage material properties from its deformational behavior as determined during...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81146-3

    authors: Eckstein F,Adam C,Sittek H,Becker C,Milz S,Schulte E,Reiser M,Putz R

    更新日期:1997-03-01 00:00:00

  • A comparison of reflection and transmission ultrasonic techniques for measurement of cancellous bone elasticity.

    abstract::A reflection ultrasonic technique, which offers several advantages over transmission ultrasonic techniques, has been described for elastic property measurement of bone. Ultrasonic velocities from specimens of cancellous bone were compared using a reflection ultrasound technique and the more traditional transmission ul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90061-2

    authors: Ashman RB,Antich PP,Gonzales J,Anderson JA,Rho JY

    更新日期:1994-09-01 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • Mechanisms of female urinary continence under stress: frequency spectrum analysis.

    abstract::Intravesical and urethral pressure signals during cough and Valsalva maneuvers for 15 continent women were analyzed with frequency spectrum analysis. Clear modulation of the urethral pressure changes by the intravesical pressure rise during stress maneuvers was demonstrated in the frequency bands of 14 and 7 Hz for co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00006-9

    authors: Kim K,Jurnalov CD,Ham S,Webb MJ,An K

    更新日期:2001-05-01 00:00:00