Biotribology of a mobile bearing posterior stabilised knee design--effect of motion restraint on wear, tibio-femoral kinematics and particles.

Abstract:

:The objective of our study was to evaluate the impact of a biphaseal anterior-posterior (AP) and internal-external (IE) motion restraint system on the wear behaviour, tibio-femoral kinematics and particle release of a mobile bearing posterior stabilised knee design in comparison to the widely used linear restraint. in vitro wear simulation was performed using a posterior stabilised total knee replacement with a mobile rotating platform gliding surface design to compare the standard ISO 14243-1:2002 (E) protocol with a linear AP and IE motion restraint and the new ISO 14243-1:2009 (E) protocol with a biphaseal AP and IE motion restraint. For the mobile gliding surfaces, an increase in wear rate by more than a magnitude was measured applying the biphaseal protocol (8.5±1.6 mg/million cycles) in a direct comparison to the linear protocol (0.33±0.07 mg/million cycles), with statistically significant difference. The amplitudes of AP displacement were 3.22±0.47 mm for the biphaseal test, compared to 1.97±0.22 mm in the linear test and the amplitudes of the IE rotation angle had mean values of 7.32°±0.91° under the biphaseal setup, compared to 1.97°±0.14° under linear motion restraint test conditions. From our observations, we conclude that the changes in AP translation and IE rotation motion restraints from ISO linear to ISO biphaseal test conditions highly impact the knee joint kinematics and wear behaviour of a mobile bearing posterior stabilised knee design.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Grupp TM,Schroeder C,Kyun Kim T,Miehlke RK,Fritz B,Jansson V,Utzschneider S

doi

10.1016/j.jbiomech.2014.04.020

subject

Has Abstract

pub_date

2014-07-18 00:00:00

pages

2415-23

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00241-3

journal_volume

47

pub_type

杂志文章
  • Experimental determination of sarcomere force-length relationship in type-I human skeletal muscle fibers.

    abstract::The objectives of this study were to measure the active and passive force-length (F-L) relationships in type-I human single muscle fibers and to compare the results to predictions from the sliding filament model (the "standard model"). We measured isometric forces in chemically skinned fibers at different sarcomere le...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.06.013

    authors: Gollapudi SK,Lin DC

    更新日期:2009-09-18 00:00:00

  • Effects of a sustained extension on arterial growth and remodeling: a theoretical study.

    abstract::Three recent studies reveal that the unloaded length of a carotid artery increases significantly and rapidly in response to sustained increases in axial extension. Moreover, such lengthening involves an "unprecedented" increase in the rate of turnover of cells and matrix. Although current data are not sufficient for d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.017

    authors: Gleason RL,Humphrey JD

    更新日期:2005-06-01 00:00:00

  • The role of elastin and collagen in the softening behavior of the human thoracic aortic media.

    abstract::In a previous study we were able to accurately fit experimental data on arterial tissues at supra-physiological loads using a material model that accounts for softening/damage only in the portion of the model associated with the collagen fibers (Weisbecker et al., 2012). Naturally, this result leads to the hypothesis ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.025

    authors: Weisbecker H,Viertler C,Pierce DM,Holzapfel GA

    更新日期:2013-07-26 00:00:00

  • Validation of the greater trochanter method with radiographic measurements of frontal plane hip joint centers and knee mechanical axis angles and two other hip joint center methods.

    abstract::Several motion capture methods exist for predicting hip joint centers (HJC). These methods include regression models, functional joints, and projections from greater trochanters. While regression and functional methods have been compared to imaging techniques, the TROCH method has not been previously validated. The pu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.06.013

    authors: Bennett HJ,Shen G,Weinhandl JT,Zhang S

    更新日期:2016-09-06 00:00:00

  • Motor unit acceleration maps and interference mechanomyographic distribution.

    abstract::The study analyses the two-dimensional distribution of surface mechanomyographic (MMG) signal generated by the activation of single motor units located in three transverse positions in the tibialis anterior muscle. In 12 healthy volunteers, surface MMG signals were recorded from the tibialis anterior muscle with a 3 x...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.07.007

    authors: Farina D,Li X,Madeleine P

    更新日期:2008-09-18 00:00:00

  • Defining gait patterns using Parallel Factor 2 (PARAFAC2): A new analysis of previously published data.

    abstract::Three-dimensional gait analysis (3D-GA) is commonly used to answer clinical questions of the form "which joints and what variables are most affected during when". When studying high-dimensional datasets, traditional dimension reduction methods (e.g. principal components analysis) require "data flattening", which may m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.035

    authors: Liew BXW,Morris S,Netto K

    更新日期:2019-06-11 00:00:00

  • A comparison of convergent and bi-plane X-ray photogrammetry systems used to detect total joint loosening.

    abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90022-7

    authors: Lippert FG 3rd,Harrington RM,Veress SA,Fraser C,Green D,Bahniuk E

    更新日期:1982-01-01 00:00:00

  • Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation?

    abstract::Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, lik...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.004

    authors: Luraghi G,Wu W,De Gaetano F,Rodriguez Matas JF,Moggridge GD,Serrani M,Stasiak J,Costantino ML,Migliavacca F

    更新日期:2017-06-14 00:00:00

  • Comparison of measurements of medial gastrocnemius architectural parameters from ultrasound and diffusion tensor images.

    abstract::In vivo measurements of muscle architecture provide insight into inter-individual differences in muscle function and could be used to personalise musculoskeletal models. When muscle architecture is measured from ultrasound images, as is frequently done, it is assumed that fascicles are oriented in the image plane and,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.012

    authors: Bolsterlee B,Veeger HE,van der Helm FC,Gandevia SC,Herbert RD

    更新日期:2015-04-13 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • An analysis of the squeeze-film lubrication mechanism for articular cartilage.

    abstract::An asymptotic analysis of a lubrication problem is presented for a model of articular cartilage and synovial fluid under the squeeze-film condition. This model is based upon the following constitutive assumptions: (1) articular cartilage is a linear porous-permeable biphasic material filled with a linearly viscous flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90024-u

    authors: Hou JS,Mow VC,Lai WM,Holmes MH

    更新日期:1992-03-01 00:00:00

  • The effect of isokinetic dynamometer deceleration phase on maximum ankle joint range of motion and plantar flexor mechanical properties tested at different angular velocities.

    abstract::During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.036

    authors: Pinto MD,Wilson CJ,Kay AD,Cochrane J,Blazevich AJ

    更新日期:2019-07-19 00:00:00

  • Adaptational responses in dynamic stability during disturbed walking in the elderly.

    abstract::The purpose of this study was to examine the age-related predictive and feedback adaptive locomotor improvements in the components of dynamic stability control during disturbed walking. Thirteen old (62-74 yrs) and ten young (23-30 yrs) male subjects performed a gait protocol on a gangway, which included one covered e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.025

    authors: Bierbaum S,Peper A,Karamanidis K,Arampatzis A

    更新日期:2010-08-26 00:00:00

  • Phalanx force magnitude and trajectory deviation increased during power grip with an increased coefficient of friction at the hand-object interface.

    abstract::This study examined the effect of friction between the hand and grip surface on a person's grip strategy and force generation capacity. Twelve young healthy adults performed power grip exertions on an instrumented vertical cylinder with the maximum and 50% of maximum efforts (far above the grip force required to hold ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.020

    authors: Enders LR,Seo NJ

    更新日期:2011-05-17 00:00:00

  • Superficial aponeurosis of human gastrocnemius is elongated during contraction: implications for modeling muscle-tendon unit.

    abstract::Two questions were addressed in this study: (1) how much strain of the superficial aponeurosis of the human medial gastrocnemius muscle (MG) was obtained during voluntary isometric contractions in vivo, (2) whether there existed inhomogeneity of the strain along the superficial aponeurosis. Seven male subjects, whose ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00196-8

    authors: Muramatsu T,Muraoka T,Kawakami Y,Fukunaga T

    更新日期:2002-02-01 00:00:00

  • A simulation study of vertical jumping from different starting postures.

    abstract::This paper addresses the question of whether maximal vertical jump height depends on initial jumping posture. A direct dynamics computer simulation approach was used to avoid subject preference and practice effects. The human body was modeled as four rigid segments connected by ideal hinge joints, with movement constr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00030-9

    authors: Selbie WS,Caldwell GE

    更新日期:1996-09-01 00:00:00

  • Micro-CT and micro-FE analysis of pedicle screw fixation under different loading conditions.

    abstract::Anchorage of pedicle screw instrumentation in the elderly spine with poor bone quality remains challenging. In this study, micro finite element (µFE) models were used to assess the specific influence of screw design and the relative contribution of local bone density to fixation mechanics. These were created from micr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.12.023

    authors: Chevalier Y,Matsuura M,Krüger S,Fleege C,Rickert M,Rauschmann M,Schilling C

    更新日期:2018-03-21 00:00:00

  • Using force sensing insoles to predict kinetic knee symmetry during a stop jump.

    abstract::Knee kinetic asymmetries are present during jump-landings in athletes returning to sport following anterior cruciate ligament (ACL) reconstruction, and are associated with an increased risk for sustaining a second ACL injury. The loadsol® is a wireless load sensing insole that can be used in non-laboratory settings. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.037

    authors: Peebles AT,Ford KR,Taylor JB,Hart JM,Sands LP,Queen RM

    更新日期:2019-10-11 00:00:00

  • Tensile property of atheromatous plaque and an analysis of stress in atherosclerotic wall.

    abstract::To know the contributions of blood pressure induced stress to the progression of atherosclerosis and the rupture of atheroma, cross-sectional distributions of stresses in atherosclerotic walls were calculated by finite element method, using stress-strain data of aortic walls and atherosclerotic plaques obtained from h...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00185-6

    authors: Hayashi K,Imai Y

    更新日期:1997-06-01 00:00:00

  • A first estimation of prestress in so-called circularly fibered osteonic lamellae.

    abstract::The existence and role of prestress in the various hierarchical structures of long bone are long standing questions. In this study, the prestress and associated strain that exist in a component of human bone microstructure, circularly fibered osteonic lamella, are estimated. Such estimates allow the formulation of hyp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00080-9

    authors: Ascenzi MG

    更新日期:1999-09-01 00:00:00

  • Challenges to bone formation in spinal fusion.

    abstract::Spinal arthrodesis continues to expand in clinical indications and surgical practice. Despite a century of study, failure of bone formation or pseudarthrosis can occur in individual patients with debilitating clinical symptoms. Here we review biological and technical aspects of spinal fusion under active investigation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2010.10.021

    authors: Reid JJ,Johnson JS,Wang JC

    更新日期:2011-01-11 00:00:00

  • Higher critical plaque wall stress in patients who died of coronary artery disease compared with those who died of other causes: a 3D FSI study based on ex vivo MRI of coronary plaques.

    abstract::Mechanical forces play an important role in the rupture of vulnerable plaques. This process is often associated with cardiovascular syndromes, such as heart attack and stroke. In this study, magnetic resonance imaging (MRI)-based models were used to investigate the association between plaque wall stress (PWS) and coro...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.007

    authors: Huang X,Yang C,Zheng J,Bach R,Muccigrosso D,Woodard PK,Tang D

    更新日期:2014-01-22 00:00:00

  • An approach to the simulation of fluid-structure interaction in the aortic valve.

    abstract::A pair of finite element models has been employed to study the interaction of blood flow with the operation of the aortic valve. A three-dimensional model of the left ventricle with applied wall displacements has been used to generate data for the spatially and time-varying blood velocity profile across the aortic ape...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.10.038

    authors: Carmody CJ,Burriesci G,Howard IC,Patterson EA

    更新日期:2006-01-01 00:00:00

  • Formation and travel of vortices in model ventricles: application to the design of skeletal muscle ventricles.

    abstract::Vortex-ring production was studied in axisymmetric elastomeric ventricles designed to stimulate flow in a cardiovascular assist device. A flow visualization technique was used to investigate the effects of reducing the inlet diameter and predilating the ventricle on vortex travel in two ventricles of different shape a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00065-8

    authors: Shortland AP,Black RA,Jarvis JC,Henry FS,Iudicello F,Collins MW,Salmons S

    更新日期:1996-04-01 00:00:00

  • Measurements of active myocardial tension under a wide range of physiological loading conditions.

    abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00122-4

    authors: Guccione JM,Le Prell GS,de Tombe PP,Hunter WC

    更新日期:1997-02-01 00:00:00

  • A mechanically decoupled two force component bicycle pedal dynamometer.

    abstract::A design is presented for a bicycle pedal dynamometer that measures both normal and tangential forces (i.e. driving forces). Mechanical decoupling is used to reduce the cross-sensitivity of the dynamometer to loads doing no work to propel the bicycle. This obviates the need to measure all six loads for accurate data r...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90144-3

    authors: Newmiller J,Hull ML,Zajac FE

    更新日期:1988-01-01 00:00:00

  • Numerical simulation of unsteady laminar flow through a tilting disk heart valve: prediction of vortex shedding.

    abstract::Heart valves induce flow disturbances which play a role in blood cell activation and damage, but questions of the magnitude and spatial distribution of fluid stresses (wall shear stress and turbulent stress) cannot be readily addressed with current experimental techniques. Therefore, a numerical simulation procedure f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90015-9

    authors: Huang ZJ,Merkle CL,Abdallah S,Tarbell JM

    更新日期:1994-04-01 00:00:00

  • Velocity profiles in annular perfusion chamber measured by laser-Doppler velocimetry.

    abstract::p6e fluid flow in the annular perfusion chamber of Baumgartner developed to study platelet vessel wall interaction was examined with laser-Doppler velocimetry. A laminar and stable flow with a Reynolds number of less than or equal to 50 was measured at flow rates up to 3 ml s-1. No turbulence was found. The wall shear...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90081-2

    authors: Aarts PA,van Broek JA,Kuiken GD,Sixma JJ,Heethaar RM

    更新日期:1984-01-01 00:00:00

  • Fabric and elastic principal directions of cancellous bone are closely related.

    abstract::Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00177-7

    authors: Odgaard A,Kabel J,van Rietbergen B,Dalstra M,Huiskes R

    更新日期:1997-05-01 00:00:00

  • An instrumental approach for monitoring physical exercises in a visual markerless scenario: A proof of concept.

    abstract::This work proposes a real-time monitoring tool aimed to support clinicians for remote assessing exercise performances during home-based rehabilitation. The study relies on clinician indications to define kinematic features, that describe five motor tasks (i.e., the lateral tilt of the trunk, lifting of the arms, trunk...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.008

    authors: Capecci M,Ceravolo MG,Ferracuti F,Grugnetti M,Iarlori S,Longhi S,Romeo L,Verdini F

    更新日期:2018-03-01 00:00:00