The effect of isokinetic dynamometer deceleration phase on maximum ankle joint range of motion and plantar flexor mechanical properties tested at different angular velocities.

Abstract:

:During range of motion (max-ROM) tests performed on an isokinetic dynamometer, the mechanical delay between the button press (by the participant to signal their max-ROM) and the stopping of joint rotation resulting from system inertia induces errors in both max-ROM and maximum passive joint moment. The present study aimed to quantify these errors by comparing data when max-ROM was obtained from the joint position data, as usual (max-ROMPOS), to data where max-ROM was defined as the first point of dynamometer arm deceleration (max-ROMACC). Fifteen participants performed isokinetic ankle joint max-ROM tests at 5, 30 and 60° s-1. Max-ROM, peak passive joint moment, end-range musculo-articular (MAC) stiffness and area under the joint moment-position curve were calculated. Greater max-ROM was observed in max-ROMPOS than max-ROMACC (P < 0.01) at 5 (0.2 ± 0.15%), 30 (1.8 ± 1.0%) and 60° s-1 (5.9 ± 2.3%), with the greatest error at the fastest velocity. Peak passive moment was greater and end-range MAC stiffness lower in max-ROMPOS than in max-ROMACC only at 60° s-1 (P < 0.01), whilst greater elastic energy storage was found at all velocities. Max-ROM and peak passive moment are affected by the delay between button press and eventual stopping of joint rotation in an angular velocity-dependent manner. This affects other variables calculated from the data. When high data accuracy is required, especially at fast joint rotation velocities (≥30° s-1), max-ROM (and associated measures calculated from joint moment data) should be taken at the point of first change in acceleration rather than at the dynamometer's ultimate joint position.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Pinto MD,Wilson CJ,Kay AD,Cochrane J,Blazevich AJ

doi

10.1016/j.jbiomech.2019.05.036

subject

Has Abstract

pub_date

2019-07-19 00:00:00

pages

169-174

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30380-X

journal_volume

92

pub_type

杂志文章
  • Elbow and wrist joint contact forces during occupational pick and place activities.

    abstract::A three-dimensional, mathematical model of the elbow and wrist joints, including 15 muscle units, 3 ligaments and 4 joint forces, has been developed. A new strain gauge transducer has been developed to measure functional grip forces. The device measures radial forces divided into six components and forces of up to 250...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00184-0

    authors: Chadwick EK,Nicol AC

    更新日期:2000-05-01 00:00:00

  • Tissue and cellular morphological changes in growth plate explants under compression.

    abstract::The mechanisms by which mechanical loading may alter bone development within growth plates are still poorly understood. However, several growth plate cell or tissue morphological parameters are associated with both normal and mechanically modulated bone growth rates. The aim of this study was to quantify in situ the t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.010

    authors: Amini S,Veilleux D,Villemure I

    更新日期:2010-09-17 00:00:00

  • No consensus on causality of spine postures or physical exposure and low back pain: A systematic review of systematic reviews.

    abstract::Specific spinal postures and physical activities have been linked to low back pain (LBP) but previous reviews have produced contrasting outcomes. This umbrella review examined (1) what relationship, if any, is evident between specific spinal postures or physical activities and LBP; (2) the quality of existing systemat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2019.08.006

    authors: Swain CTV,Pan F,Owen PJ,Schmidt H,Belavy DL

    更新日期:2020-03-26 00:00:00

  • Body weight support impacts lateral stability during treadmill walking.

    abstract::Body weight support (BWS) systems are a common tool used in gait rehabilitation. BWS systems may alter the requirements for an individual to actively stabilize by 1) providing lateral restoring forces that reduce the requirements for the nervous system to actively stabilize and 2) decreasing the stabilizing gravitatio...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.026

    authors: Dragunas AC,Gordon KE

    更新日期:2016-09-06 00:00:00

  • Versatile and inexpensive Hall-Effect force sensor for mechanical characterization of soft biological materials.

    abstract::Mismatch of hierarchical structure and mechanical properties between tissue-engineered implants and native tissue may result in signal cues that negatively impact repair and remodeling. With bottom-up tissue engineering approaches, designing tissue components with proper microscale mechanical properties is crucial to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.11.065

    authors: Backman DE,LeSavage BL,Wong JY

    更新日期:2017-01-25 00:00:00

  • Comparison between in vivo and theoretical bite performance: using multi-body modelling to predict muscle and bite forces in a reptile skull.

    abstract::In biomechanical investigations, geometrically accurate computer models of anatomical structures can be created readily using computed-tomography scan images. However, representation of soft tissue structures is more challenging, relying on approximations to predict the muscle loading conditions that are essential in ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.05.037

    authors: Curtis N,Jones ME,Lappin AK,O'Higgins P,Evans SE,Fagan MJ

    更新日期:2010-10-19 00:00:00

  • Mechanical properties of double-stranded DNA biolayers immobilized on microcantilever under axial compression.

    abstract::In label-free biodetections based on microcantilever technology, double-stranded DNA (dsDNA) structures form through the linkage between probe single-stranded DNA (ssDNA) molecules immobilized on solid substrates and target ssDNA molecules in solutions. Mechanical/electrical properties of these biolayers are important...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.050

    authors: Zhang NH,Chen JZ

    更新日期:2009-07-22 00:00:00

  • A mechanical model for the human intervertebral disc.

    abstract::Stress relaxation experiments were performed on specimens from a human intervertebral disc. Specimens were made from the nucleus pulposus and from the external lamellae of the anulus fibrosus in two different orientations. Tests were run with varying moisture content so as to develop a relaxation master curve. A model...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90144-8

    authors: Panagiotacopulos ND,Pope MH,Krag MH,Bloch R

    更新日期:1987-01-01 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • Computational musculoskeletal modeling of compensatory movements in the upper limb.

    abstract::It is well documented that most upper limb amputees utilize compensatory movement strategies to accomplish everyday tasks when using a prosthetic device and that musculoskeletal complaints (MSCs) are more common in this population. However, little information is available on how the loss of distal degrees of freedom (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109843

    authors: Reilly M,Kontson K

    更新日期:2020-07-17 00:00:00

  • Walking at the preferred stride frequency maximizes local dynamic stability of knee motion.

    abstract::Healthy humans display a preference for walking at a stride frequency dependent on the inertial properties of their legs. Walking at preferred stride frequency (PSF) is predicted to maximize local dynamic stability, whereby sensitivity to intrinsic perturbations arising from natural variability inherent in biological ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.012

    authors: Russell DM,Haworth JL

    更新日期:2014-01-03 00:00:00

  • Hydro-mechanical coupling in the periodontal ligament: a porohyperelastic finite element model.

    abstract::Harmonic tension-compression tests at 0.1, 0.5 and 1 Hz on hydrated bovine periodontal ligament (PDL) were numerically simulated. The process was modeled by finite elements (FE) within the framework of poromechanics, with the objective of isolating the contributions of the solid- and fluid phases. The solid matrix was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.019

    authors: Bergomi M,Cugnoni J,Galli M,Botsis J,Belser UC,Wiskott HW

    更新日期:2011-01-04 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00

  • Direct perfusion measurements of cancellous bone anisotropic permeability.

    abstract::More extensive characterization of trabecular connectivity and intertrabecular space will be instrumental in understanding disease states and designing engineered bone. This project presents an experimental protocol to define the directional dependence of transport properties as measured from healthy cancellous bone w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00082-3

    authors: Kohles SS,Roberts JB,Upton ML,Wilson CG,Bonassar LJ,Schlichting AL

    更新日期:2001-09-01 00:00:00

  • Prior storage conditions and loading rate affect the in vitro fracture response of spinal segments under impact loading.

    abstract::Traumatic injuries of the spine are mostly the consequence of rapid overload e.g. impact loading. In vitro investigations on this topic usually encompass biomechanical testing using frozen/thawed specimens and employ quasi-static loading conditions. It is generally accepted that a freezing/thawing cycle does not alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.011

    authors: Dudli S,Haschtmann D,Ferguson SJ

    更新日期:2011-09-02 00:00:00

  • The effects of exterior boundary conditions on a internally heated tumor tissue with a thermoporoelastic model.

    abstract::Modeling flow field in tumor regions interstitial space is of primary importance, because of the importance of advection in macromolecule drug delivery. Its deformation has also to be taken into account because of the forces caused by the fluid; if the tumor region is not isothermal, this deformation can be also stron...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110122

    authors: Andreozzi A,Iasiello M,Netti PA

    更新日期:2020-12-02 00:00:00

  • Strain-induced damage reduces echo intensity changes in tendon during loading.

    abstract::Tendon functionality is related to its mechanical properties. Tendon damage leads to a reduction in mechanical strength and altered biomechanical behavior, and therefore leads to compromised ability to carry out normal functions such as joint movement and stabilization. Damage can also accumulate in the tissue and lea...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.004

    authors: Duenwald-Kuehl S,Lakes R,Vanderby R Jr

    更新日期:2012-06-01 00:00:00

  • Revolutionizing orthopaedic biomaterials: The potential of biodegradable and bioresorbable magnesium-based materials for functional tissue engineering.

    abstract::In recent years, there has been a surge of interest in magnesium (Mg) and its alloys as biomaterials for orthopaedic applications, as they possess desirable mechanical properties, good biocompatibility, and biodegradability. Also shown to be osteoinductive, Mg-based materials could be particularly advantageous in func...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2013.12.003

    authors: Farraro KF,Kim KE,Woo SL,Flowers JR,McCullough MB

    更新日期:2014-06-27 00:00:00

  • Separating brain motion into rigid body displacement and deformation under low-severity impacts.

    abstract::The relative motion of the brain with respect to the skull has been widely studied to investigate brain injury mechanisms under impacts, but the motion patterns are not yet thoroughly understood. This work analyzes brain motion patterns using the most recent and advanced experimental relative brain/skull motion data c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2006.06.018

    authors: Zou H,Schmiedeler JP,Hardy WN

    更新日期:2007-01-01 00:00:00

  • Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    abstract::Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.011

    authors: Zheng D,Murray A

    更新日期:2009-05-29 00:00:00

  • Differences in 3D vs. 2D analysis in lumbar spinal fusion simulations.

    abstract::Lumbar interbody fusion is currently the gold standard in treating patients with disc degeneration or segmental instability. Despite it having been used for several decades, the non-union rate remains high. A failed fusion is frequently attributed to an inadequate mechanical environment after instrumentation. Finite e...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.009

    authors: Hsu HW,Bashkuev M,Pumberger M,Schmidt H

    更新日期:2018-04-27 00:00:00

  • Three-dimensional finite element analysis of glass-ceramic dental crowns.

    abstract::Because of the improved esthetic potential of glass-ceramic crowns as dental restorations, they are sometimes preferred over metal-ceramic crowns for restoration of anterior teeth. Because of their relatively high strength, these ceramic crowns are also frequently used for restoration of posterior teeth. However, due ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90008-q

    authors: Hojjatie B,Anusavice KJ

    更新日期:1990-01-01 00:00:00

  • Pure moment testing for spinal biomechanics applications: Fixed versus sliding ring cable-driven test designs.

    abstract::In vitro multi-axial bending testing using pure moment loading conditions has become the standard in evaluating the effects of different types of surgical intervention on spinal kinematics. Simple, cable-driven experimental set-ups have been widely adopted because they require little infrastructure. Traditionally, "fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.02.004

    authors: Eguizabal J,Tufaga M,Scheer JK,Ames C,Lotz JC,Buckley JM

    更新日期:2010-05-07 00:00:00

  • Extracellular NO signalling from a mechanically stimulated osteocyte.

    abstract::Bone remodelling is a dynamic process that requires the coordinated interaction of osteocytes, osteoblasts, and osteoclasts, collaborating in basic multicellular units (BMUs). Communication between these cells can be by extracellular soluble molecules as well as directly propagating intercellular signalling molecules....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.015

    authors: Vatsa A,Smit TH,Klein-Nulend J

    更新日期:2007-01-01 00:00:00

  • Dynamic tensile properties of bovine periodontal ligament: A nonlinear viscoelastic model.

    abstract::As a support to the tooth, the mechanical response of the periodontal ligament (PDL) is complex. Like other connective tissues, the PDL exhibits non-linear and time-dependent behavior. The viscoelasticity of the PDL plays a significant role in low and high loading rates. Little information, however, is available on th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.020

    authors: Oskui IZ,Hashemi A

    更新日期:2016-03-21 00:00:00

  • T2 relaxation time measurements in tibiotalar cartilage after barefoot running and its relationship to ankle biomechanics.

    abstract::The influence of ankle kinematics and plantar pressure from mid-range barefoot running on T2 relaxation times of tibiotalar cartilage is unknown. This study aimed to quantitatively evaluate the T2 relaxation time of tibiotalar cartilage and ankle biomechanics following 5 km barefoot running. Twenty healthy runners (wh...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.046

    authors: Kyung Kim H,Fernandez J,Logan C,Tarr GP,Doyle A,Mirjalili SA

    更新日期:2019-06-11 00:00:00

  • Is a joint moment-based cost function associated with preferred cycling cadence?

    abstract::Eight experienced male cyclists (C), eight well-trained male runners (R), and eight less-trained male noncyclists (LT) were tested under multiple cadence and power output conditions to determine: (1) if the cadence at which lower extremity net joint moments are minimized (cost function cadence) was associated with pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00155-4

    authors: Marsh AP,Martin PE,Sanderson DJ

    更新日期:2000-02-01 00:00:00

  • Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.

    abstract::The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90006-7

    authors: DiAngelo DJ,Winter DA,Ghista DN,Newcombe WR

    更新日期:1989-01-01 00:00:00

  • Changes of opening angle in hypertensive and hypotensive arteries in 3-day organ culture.

    abstract::To study the effect of pressure changes on the opening angle of arteries in organ culture, tubular segments of porcine common carotid arteries were cultured with pulsatile flow perfusion under hypertensive (150+/-20 mmHg), normotensive (100+/-20 mmHg), or hypotensive (30+/-10 mmHg) pressure while maintaining the arter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.08.003

    authors: Han HC,Marita S,Ku DN

    更新日期:2006-01-01 00:00:00

  • Sagittal plane rotation center of lower lumbar spine during a dynamic weight-lifting activity.

    abstract::This study investigated the center of rotation (COR) of the intervertebral segments of the lower lumbar spine (L4-L5 and L5-S1 segments) in sagittal plane during a weight-lifting (3.6 kg in each hand) extension activity performed with the pelvis constrained. Seven healthy subjects were studied using a dual fluoroscopi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.029

    authors: Liu Z,Tsai TY,Wang S,Wu M,Zhong W,Li JS,Cha T,Wood K,Li G

    更新日期:2016-02-08 00:00:00