No consensus on causality of spine postures or physical exposure and low back pain: A systematic review of systematic reviews.

Abstract:

:Specific spinal postures and physical activities have been linked to low back pain (LBP) but previous reviews have produced contrasting outcomes. This umbrella review examined (1) what relationship, if any, is evident between specific spinal postures or physical activities and LBP; (2) the quality of existing systematic reviews in this area; and (3) the extent to which previous systematic reviews demonstrate causality. Five electronic databases and reference lists of relevant articles were searched from January 1990 to June 2018. Systematic reviews and meta-analyses on spine posture or physical exposure and LBP symptoms (self-report) or outcomes (e.g. work absence, medical consultation) were included. The AMSTAR and the Bradford Hill Criteria were utilised to critically appraise the quality of included systematic reviews and to determine the extent to which these reviews demonstrated causality. Two independent reviewers screened 4285 publications with 41 reviews included in the final review. Both positive and null associations between spine posture, prolonged standing, sitting, bending and twisting, awkward postures, whole body vibration, and components of heavy physical work were reported. Results from meta-analyses were more consistently in favour of an association, whereas systematic reviews that included only prospective studies were less able to provide consistent conclusions. Evidence that these factors precede first time LBP or have a dose response relationship with LBP outcomes was mixed. Despite the availability of many reviews, there is no consensus regarding causality of physical exposure to LBP. Association has been documented but does not provide a causal explanation for LBP.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Swain CTV,Pan F,Owen PJ,Schmidt H,Belavy DL

doi

10.1016/j.jbiomech.2019.08.006

subject

Has Abstract

pub_date

2020-03-26 00:00:00

pages

109312

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(19)30524-X

journal_volume

102

pub_type

杂志文章,评审
  • Velocity profiles in the wake of two prosthetic heart valves using a new cardiovascular simulator.

    abstract::In this paper we present a study of the post valvular flow field on a new cardiovascular simulator including an elastic model of the aortic arch. Transverse and vertical two-dimensional velocity measurements are performed with an ultrasonic velocimeter. Two prosthetic heart valves are tested in the aortic position. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(85)90054-5

    authors: Farahifar D,Cassot F,Bodard H,Pelissier R

    更新日期:1985-01-01 00:00:00

  • Effects of different temperatures, velocities and loads on the gliding resistance of flexor digitorum profundus tendons in a human cadaver model.

    abstract::The purpose of this study was to investigate the effects of temperature, velocity and load on the gliding resistance (GR) of flexor digitorum profundus (FDP) tendons in a human cadaver model. A total of 40 FDP tendons from the index through small digits of ten human cadavers were tested to assess the effect of tempera...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.01.011

    authors: Moriya T,Chikenji T,Thoreson AR,Zhao C,An KN,Amadio PC

    更新日期:2011-04-29 00:00:00

  • Patient-specific bone modelling and remodelling simulation of hypoparathyroidism based on human iliac crest biopsies.

    abstract::We previously developed a load-adaptive bone modelling and remodelling simulation model that can predict changes in the bone micro-architecture as a result of changes in mechanical loading or cell activity. In combination with a novel algorithm to estimate loading conditions, this offers the possibility for patient-sp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.031

    authors: Christen P,Ito K,Müller R,Rubin MR,Dempster DW,Bilezikian JP,van Rietbergen B

    更新日期:2012-09-21 00:00:00

  • In vitro analysis of a model of intracardiac jet: analysis of the central core of axisymmetric jets.

    abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90367-c

    authors: Diebold B,Delouche A,Dumée P,Guglielmi JP,Delouche P,Péronneau P

    更新日期:1990-01-01 00:00:00

  • A state-space analysis of mechanical energy generation, absorption, and transfer during pedaling.

    abstract::Seated ergometer pedaling is a motor task ideal for studying basic mechanisms of human bipedal coordination because, in contrast to standing and walking, fewer degrees of freedom are being controlled and upright balance is not a factor. As a step toward understanding how individual muscles coordinate pedaling, we inve...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00011-9

    authors: Fregly BJ,Zajac FE

    更新日期:1996-01-01 00:00:00

  • Computer simulation of blood flow in the human arm.

    abstract::This paper considers a finite element method to characterize blood flow in the human arm arteries. A set of different pressure waveforms, which represent normal and diseased heart pulses, is used for the proximal boundary conditions, and a modified Windkessel model is used for the distal arterial boundary conditions. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90019-5

    authors: Balar SD,Rogge TR,Young DF

    更新日期:1989-01-01 00:00:00

  • Accuracy of WAAS-enabled GPS for the determination of position and speed over ground.

    abstract::The Global Positioning System (GPS) offers many advantages over conventional methods for the determination of subject speed during biomechanical studies. Recent advances in GPS technology, in particular the implementation of the Wide-Angle Augmentation System and European Geostationary Navigation Overlay Service (WAAS...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.07.028

    authors: Witte TH,Wilson AM

    更新日期:2005-08-01 00:00:00

  • Mechanical behaviour of femoral bones in bending loading.

    abstract::A series of 33 human femoral bones have been subjected to a four point bending test at high strain rates. Two different failure modes were recognized. A Y shaped fracture at the middle region induced by a pure bending moment yielded a zone of non-linearity at the load vs deformation curve and a higher bending force, m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90021-7

    authors: Martens M,van Audekercke R,de Meester P,Mulier JC

    更新日期:1986-01-01 00:00:00

  • Coping with perturbations to a layout somersault in tumbling.

    abstract::Tumbling is a dynamic movement requiring control of the linear and angular momenta generated during the approach and takeoff phases. Both of these phases are subject to some variability even when the gymnast is trying to perform a given movement repeatedly. This paper used a simulation model of tumbling takeoff to est...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00077-0

    authors: King MA,Yeadon MR

    更新日期:2003-07-01 00:00:00

  • Effect of scaffold material, construct length and mechanical stimulation on the in vitro stiffness of the engineered tendon construct.

    abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.009

    authors: Nirmalanandhan VS,Rao M,Shearn JT,Juncosa-Melvin N,Gooch C,Butler DL

    更新日期:2008-01-01 00:00:00

  • Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

    abstract:PURPOSE:Approximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.01.022

    authors: Ibrahim MM,Poveromo LP,Glisson RR,Cornejo A,Farjat AE,Gall K,Levinson H

    更新日期:2018-04-11 00:00:00

  • Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force.

    abstract::As a hybrid between a hypodermic needle and transdermal patch, we have used microfabrication technology to make arrays of micron-scale needles that transport drugs and other compounds across the skin without causing pain. However, not all microneedle geometries are able to insert into skin at reasonable forces and wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.12.010

    authors: Davis SP,Landis BJ,Adams ZH,Allen MG,Prausnitz MR

    更新日期:2004-08-01 00:00:00

  • Evaluation of human nasal cartilage nonlinear and rate dependent mechanical properties.

    abstract::Nasal reconstruction frequently requires donor cartilage and tissue, and ideally, donor tissue will closely emulate native nasal cartilage mechanics. Tissue engineering scaffolds, especially 3D printed scaffolds, have been proposed for nasal reconstruction, and the success of these constructs may depend on how well sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109549

    authors: Chang B,Reighard C,Flanagan C,Hollister S,Zopf D

    更新日期:2020-02-13 00:00:00

  • Characterizing gait induced normal strains in a murine tibia cortical bone defect model.

    abstract::The critical role that mechanical stimuli serve in mediating bone repair is recognized but incompletely understood. Further, previous attempts to understand this role have utilized application of externally applied mechanical loads to study the tissue's response. In this project, we have therefore endeavored to capita...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.06.030

    authors: Prasad J,Wiater BP,Nork SE,Bain SD,Gross TS

    更新日期:2010-10-19 00:00:00

  • Index-matched measurements of the effect of cartilaginous rings on tracheobronchial flow.

    abstract::We present a comparison of the flow characteristics in an idealized smooth trachea model and a second model which has a roughness simulating cartilaginous rings. We use refractive index-matched particle image velocimetry (PIV) to measure the velocity field in a two-generation model of the trachea and main bronchi. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.043

    authors: Bocanegra Evans H,Castillo L

    更新日期:2016-06-14 00:00:00

  • 3D kinematic and dynamic analysis of the front crawl tumble turn in elite male swimmers.

    abstract::The aim of this study was to identify kinematic and dynamic variables related to the best tumble turn times (3mRTT, the turn time from 3-m in to 3-m out, independent variable) in ten elite male swimmers using a three-dimensional (3D) underwater analysis protocol and the Lasso (least absolute shrinkage and selection op...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.043

    authors: Puel F,Morlier J,Avalos M,Mesnard M,Cid M,Hellard P

    更新日期:2012-02-02 00:00:00

  • Skewness angle of interfibrillar proteoglycans increases with applied load on mitral valve chordae tendineae.

    abstract::In highly aligned connective tissues, such as tendon, collagen fibrils are linked together by proteoglycans (PGs). Recent mechanical and theoretical studies on tendon micromechanics have implied that PGs mediate mechanical interactions between adjacent collagen fibrils. We used transmission electron microscopy to obse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.12.011

    authors: Liao J,Vesely I

    更新日期:2007-01-01 00:00:00

  • Mathematical model of microbicidal flow dynamics and optimization of rheological properties for intra-vaginal drug delivery: Role of tissue mechanics and fluid rheology.

    abstract::Topically applied microbicide gels can provide a self-administered and effective strategy to prevent sexually transmitted infections (STIs). We have investigated the interplay between vaginal tissue elasticity and the yield-stress of non-Newtonian fluids during microbicide deployment. We have developed a mathematical ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.01.049

    authors: Anwar MR,Camarda KV,Kieweg SL

    更新日期:2015-06-25 00:00:00

  • Study of cradle and pendulum motion for applications to health care.

    abstract::Hammocks and cradles have long been appreciated, but in a very limited way. Aside from being emotionally soothing the devices affect the skin and all deep body components. While structurally simple they are functionally quite sophisticated and could very well affect the pattern of health care across the board--acute, ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90089-7

    authors: Frisina W

    更新日期:1984-01-01 00:00:00

  • Reference point indentation study of age-related changes in porcine femoral cortical bone.

    abstract::The reference point indentation (RPI) method is a microindentation technique involving successive indentation cycles. We employed RPI to measure average stiffness (Ave US), indentation distance increase (IDI), total indentation distance (TID), average energy dissipated (Ave ED), and creep indentation distance (CID) of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.003

    authors: Rasoulian R,Raeisi Najafi A,Chittenden M,Jasiuk I

    更新日期:2013-06-21 00:00:00

  • Stability basin estimates fall risk from observed kinematics, demonstrated on the Sit-to-Stand task.

    abstract::The ability to quantitatively measure stability is essential to ensuring the safety of locomoting systems. While the response to perturbation directly reflects the stability of a motion, this experimental method puts human subjects at risk. Unfortunately, existing indirect methods for estimating stability from unpertu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.022

    authors: Shia V,Moore TY,Holmes P,Bajcsy R,Vasudevan R

    更新日期:2018-04-27 00:00:00

  • Body segments decoupling in sitting: control of body posture from automatic chair adjustments.

    abstract:BACKGROUND:Individuals who cannot functionally reposition themselves adopt a passive body posture and suffer from physical discomfort in long-term sitting. To regulate body load and to prevent sitting related mobility problems, proper posture control is important. The inability to reposition underlines the importance f...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.09.017

    authors: van Geffen P,Molier BI,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-12-05 00:00:00

  • In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics.

    abstract::The objective of the current study was to use fluoroscopy to accurately determine the three-dimensional (3D), in vivo, weight-bearing kinematics of 10 normal and five anterior cruciate ligament deficient (ACLD) knees. Patient-specific bone models were derived from computed tomography (CT) data. 3D computer bone models...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.02.042

    authors: Dennis DA,Mahfouz MR,Komistek RD,Hoff W

    更新日期:2005-02-01 00:00:00

  • Does the activity of ankle plantar flexors differ between limbs while healthy, young subjects stand at ease?

    abstract::Inferences on the active contribution of plantar flexors to the stabilisation of human standing posture have been drawn from surface electromyograms (EMGs). Surface EMGs were however often detected unilaterally, presuming the myoelectric activity from muscles in a single leg reflects the pattern of muscle activation i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.018

    authors: Dos Anjos FV,Gazzoni M,Vieira TM

    更新日期:2018-11-16 00:00:00

  • Bi-linear mechanical property determination of acellular human patellar tendon grafts for use in anterior cruciate ligament replacement.

    abstract::Anterior cruciate ligament rupture is rising in its prevalence amongst the young and those with physically active lifestyles. Acellular human patellar tendon (PT) grafts offer a promising restoration solution, returning knee joint stability and overcoming some of the current disadvantages of autologous or allogeneic g...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.041

    authors: Herbert A,Brown C,Rooney P,Kearney J,Ingham E,Fisher J

    更新日期:2016-06-14 00:00:00

  • Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.

    abstract::The hemodynamic influence of vessel shape such as bifurcation angle is not fully understood with clinical and quantitative observations being equivocal. The aim of this study is to use computational modeling to study the hemodynamic effect of shape characteristics, in particular bifurcation angle (BA), for non-stented...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.038

    authors: Beier S,Ormiston J,Webster M,Cater J,Norris S,Medrano-Gracia P,Young A,Cowan B

    更新日期:2016-06-14 00:00:00

  • Model studies of the flow in abdominal aortic aneurysms during resting and exercise conditions.

    abstract::Pulsatile flow in abdominal aortic aneurysm (AAA) models has been examined in order to understand the hemodynamics that may contribute to growth of an AAA. The model studies were conducted by experiments (flow visualization and laser Doppler velocimetry) and by numerical simulation using physiologically realistic rest...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00134-7

    authors: Egelhoff CJ,Budwig RS,Elger DF,Khraishi TA,Johansen KH

    更新日期:1999-12-01 00:00:00

  • Analysis of head acceleration events in collegiate-level American football: A combination of qualitative video analysis and in-vivo head kinematic measurement.

    abstract::The contact nature of American football has made head acceleration exposure a concern. We aimed to quantify the head kinematics associated with direct helmet contact and inertial head loading events in collegiate-level American football. A cohort of collegiate-level players were equipped with instrumented mouthguards ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109969

    authors: Tierney GJ,Kuo C,Wu L,Weaving D,Camarillo D

    更新日期:2020-09-18 00:00:00

  • Biomechanical analyses of stair-climbing while dual-tasking.

    abstract::Stair-climbing while doing a concurrent task like talking or holding an object is a common activity of daily living which poses high risk for falls. While biomechanical analyses of overground walking during dual-tasking have been studied extensively, little is known on the biomechanics of stair-climbing while dual-tas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.024

    authors: Vallabhajosula S,Tan CW,Mukherjee M,Davidson AJ,Stergiou N

    更新日期:2015-04-13 00:00:00

  • Mitogen-activated protein kinase signaling in bovine articular chondrocytes in response to fluid flow does not require calcium mobilization.

    abstract::In the present study, the role of mitogen-activated protein kinases (MAPKs) in chondrocyte mechanotransduction was investigated. We hypothesized that MAPKs participate in fluid flow-induced chondrocyte mechanotransduction. To test our hypothesis, we studied cultured chondrocytes subjected to a well-defined mechanical ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00176-1

    authors: Hung CT,Henshaw DR,Wang CC,Mauck RL,Raia F,Palmer G,Chao PH,Mow VC,Ratcliffe A,Valhmu WB

    更新日期:2000-01-01 00:00:00