Reference point indentation study of age-related changes in porcine femoral cortical bone.

Abstract:

:The reference point indentation (RPI) method is a microindentation technique involving successive indentation cycles. We employed RPI to measure average stiffness (Ave US), indentation distance increase (IDI), total indentation distance (TID), average energy dissipated (Ave ED), and creep indentation distance (CID) of swine femoral cortical bone (mid-diaphysis) as a function of age (1, 3.5, 6, 14.5, 24, and 48 months) and loading directions (longitudinal and transverse). The Ave US increases with animal age, while the IDI, TID, Ave ED, and CID decrease with age, for both longitudinal (transverse surface) and transverse (periosteal surface) loading directions. Longitudinal measurements generally give higher Ave US and lower IDI and TID values compared to transverse measurements. The RPI measurements show similar trends to those obtained using nanoindentation test, and ash and water content tests.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Rasoulian R,Raeisi Najafi A,Chittenden M,Jasiuk I

doi

10.1016/j.jbiomech.2013.04.003

subject

Has Abstract

pub_date

2013-06-21 00:00:00

pages

1689-96

issue

10

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(13)00180-2

journal_volume

46

pub_type

杂志文章
  • Compressive creep behavior of bovine trabecular bone.

    abstract::There are almost no published data that describe the creep behavior of trabecular bone (at the specimen level), even though the creep behavior of cortical bone has been well documented. In an effort to characterize the creep behavior of trabecular bone and to compare it with that of cortical bone, we performed uniaxia...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(94)90006-x

    authors: Bowman SM,Keaveny TM,Gibson LJ,Hayes WC,McMahon TA

    更新日期:1994-03-01 00:00:00

  • Explicit finite element modeling of total knee replacement mechanics.

    abstract::Joint kinematics and contact mechanics dictate the success of current total knee replacement (TKR) devices. Efficient computer models present an effective way of evaluating these characteristics. Predicted contact stress and area due to articulations at the tibio-femoral and patello-femoral interfaces indicate potenti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.046

    authors: Halloran JP,Petrella AJ,Rullkoetter PJ

    更新日期:2005-02-01 00:00:00

  • Numerical simulations of the pulsating flow of cerebrospinal fluid flow in the cervical spinal canal of a Chiari patient.

    abstract::The flow of cerebrospinal fluid (CSF) in a patient-specific model of the subarachnoid space in a Chiari I patient was investigated using numerical simulations. The pulsating CSF flow was modeled using a time-varying velocity pulse based on peak velocity measurements (diastole and systole) derived from a selection of p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.023

    authors: Helgeland A,Mardal KA,Haughton V,Reif BA

    更新日期:2014-03-21 00:00:00

  • Effect of implementing magnetic resonance imaging for patient-specific OpenSim models on lower-body kinematics and knee ligament lengths.

    abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.016

    authors: Smale KB,Conconi M,Sancisi N,Krogsgaard M,Alkjaer T,Parenti-Castelli V,Benoit DL

    更新日期:2019-01-23 00:00:00

  • Material characterization of the brainstem from oscillatory shear tests.

    abstract::Traumatic damage to the brainstem occurs frequently when the brain skull complex experiences injurious loading especially during those traumatic situations that produce diffuse axonal injury (DAI). DAI has been shown to be dependent on load direction and correlated with regional tissue deformation in response to rotat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00068-2

    authors: Arbogast KB,Margulies SS

    更新日期:1998-09-01 00:00:00

  • Defining gait patterns using Parallel Factor 2 (PARAFAC2): A new analysis of previously published data.

    abstract::Three-dimensional gait analysis (3D-GA) is commonly used to answer clinical questions of the form "which joints and what variables are most affected during when". When studying high-dimensional datasets, traditional dimension reduction methods (e.g. principal components analysis) require "data flattening", which may m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.035

    authors: Liew BXW,Morris S,Netto K

    更新日期:2019-06-11 00:00:00

  • Study on modelling of PMMA bone cement polymerisation.

    abstract::This contribution is concerned with the modelling of PMMA-based bone cement polymerisation process and the associated heat effect. While existing models use description in terms of the so-called polymerisation fraction to fit the experimental data, the new model is constructed in such a way as to mimic the chemical pr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.06.021

    authors: Stańczyk M

    更新日期:2005-07-01 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • In vivo knee joint loading and kinematics before and after ACL transection in an animal model.

    abstract::Osteoarthritis (OA) is typically diagnosed in humans in its final stage when joint movement becomes painful. Clinical information about the onset and the mechanisms triggering the degenerative responses are virtually non-existent. However, research on animal models of experimental OA shows that joint adaptations assoc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00119-x

    authors: Hasler EM,Herzog W,Leonard TR,Stano A,Nguyen H

    更新日期:1998-03-01 00:00:00

  • Vastus lateralis and vastus medialis produce distinct mediolateral forces on the patella but similar forces on the tibia in the rat.

    abstract::Improper activation of the quadriceps muscles vastus medialis (VM) and vastus lateralis (VL) has been implicated in the development of patellofemoral pain (PFP). This explanation of PFP assumes that VM and VL produce opposing mediolateral forces on the patella. Although studies have provided evidence for opposing acti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.007

    authors: Sandercock TG,Wei Q,Dhaher YY,Pai DK,Tresch MC

    更新日期:2018-11-16 00:00:00

  • Loads on an internal spinal fixation device during sitting.

    abstract::Sitting is often assumed to involve high loads on the spine as well as on implants for stabilising the spine. Loads on internal spinal fixation devices were therefore measured in ten patients sitting on several types of seats, including a stool, a stool with a padded wedge, a chair, a physiotherapy ball, a knee-stool,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00073-2

    authors: Rohlmann A,Arntz U,Graichen F,Bergmann G

    更新日期:2001-08-01 00:00:00

  • Computational model of airflow in upper 17 generations of human respiratory tract.

    abstract::Computational fluid dynamics (CFD) studies of airflow in a digital reference model of the 17-generation airway (bronchial tree) were accomplished using the FLUENT computational code, based on the anatomical model by Schmidt et al. [2004. A digital reference model of the human bronchial tree. Computerized Medical Imagi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.12.019

    authors: Gemci T,Ponyavin V,Chen Y,Chen H,Collins R

    更新日期:2008-01-01 00:00:00

  • Identification of a hemodynamic parameter for assessing treatment outcome of EDAS in Moyamoya disease.

    abstract::This work is a novel attempt to incorporate computational fluid dynamics (CFD) techniques in the analysis of hemodynamic parameters of Moyamoya disease (MMD). Highly prevalent in Asian countries, MMD is characterised by progressive occlusion of the intracranial Internal Carotid Arteries (ICA). We intend to identify a ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.029

    authors: Karunanithi K,Han C,Lee CJ,Shi W,Duan L,Qian Y

    更新日期:2015-01-21 00:00:00

  • Can fabric sensors monitor breast motion?

    abstract::To establish whether conducting polymer-coated fabric sensors could be used to monitor breast motion, vertical breast motion of two large breasted women (C+ bra cup) was simultaneously monitored using an OPTOTRAK 3020 motion analysis system (200 Hz) and polymer-coated fabric sensors linked to a custom-made Bluetooth t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.020

    authors: Campbell TE,Munro BJ,Wallace GG,Steele JR

    更新日期:2007-01-01 00:00:00

  • Sex differences in active tibialis anterior stiffness evaluated using supersonic shear imaging.

    abstract::This study aimed to evaluate the sex difference in active muscle stiffness of the tibialis anterior muscle (TA) through shear modulus measurements performed using supersonic shear imaging (SSI) technique. Twenty-five women and twenty-one men participated in this study. Joint torque, electromyographic (EMG) activity an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.08.008

    authors: Souron R,Bordat F,Farabet A,Belli A,Feasson L,Nordez A,Lapole T

    更新日期:2016-10-03 00:00:00

  • Effects of patella alta and patella infera on patellofemoral contact forces.

    abstract::The relationship between patella alta and patellar subluxation may, in part, reflect the relationship between the height of the patella above the tibiofemoral joint line and the patellofemoral contact force. This study reports on the direct in vitro measurement of the patellofemoral contact force, and its point of app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90222-4

    authors: Singerman R,Davy DT,Goldberg VM

    更新日期:1994-08-01 00:00:00

  • Challenges to bone formation in spinal fusion.

    abstract::Spinal arthrodesis continues to expand in clinical indications and surgical practice. Despite a century of study, failure of bone formation or pseudarthrosis can occur in individual patients with debilitating clinical symptoms. Here we review biological and technical aspects of spinal fusion under active investigation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2010.10.021

    authors: Reid JJ,Johnson JS,Wang JC

    更新日期:2011-01-11 00:00:00

  • Water in hydroxyapatite nanopores: Possible implications for interstitial bone fluid flow.

    abstract::The role of bone water in the activity of this organ is essential in structuring apatite crystals, providing pathways for nutrients and waste involved in the metabolism of bone cells and participating in bone remodelling mechanotransduction. It is commonly accepted that bone presents three levels of porosity, namely t...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.07.025

    authors: Lemaire T,Pham TT,Capiez-Lernout E,de Leeuw NH,Naili S

    更新日期:2015-09-18 00:00:00

  • Effects of sagittal postural adjustments on seat reaction load.

    abstract::Wheelchair-dependent subjects often adopt a passive sitting posture and suffer from sitting acquired pressure ulcers (PU) that mainly occur when high buttock pressures sustain for a longer period of time. Body posture directly influences seating load and proper postural change is therefore essential. Many subjects can...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.04.012

    authors: van Geffen P,Reenalda J,Veltink PH,Koopman BF

    更新日期:2008-07-19 00:00:00

  • A holistic approach to study the temporal variability in gait.

    abstract::Movement variability has become an important field of research and has been studied to gain a better understanding of the neuro-muscular control of human movements. In addition to studies investigating "amplitude variability" there are a growing number of studies assessing the "temporal variability" in movements by ap...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.008

    authors: Federolf P,Tecante K,Nigg B

    更新日期:2012-04-30 00:00:00

  • Effects of fixation and preservation on tissue elastic properties measured by quantitative optical coherence elastography (OCE).

    abstract::Fixed and preserved tissues have been massively used in the development of biomedical equipment and instrumentation. Not only the tissue morphology, but also its mechanical properties need to be considered in the fixation and preservation procedures since mechanical properties have significant influence on the design ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.013

    authors: Ling Y,Li C,Feng K,Duncan R,Eisma R,Huang Z,Nabi G

    更新日期:2016-05-03 00:00:00

  • Performance assessment of the Terry Fox jogging prosthesis for above-knee amputees.

    abstract::The Terry Fox jogging (TFJ) prosthesis was developed at Chedoke-McMaster Hospital to alleviate the asymmetric jogging pattern experienced by above-knee amputees when attempting to jog with conventional walking prostheses. This prosthesis features a spring-loaded, telescoping shank designed to eliminate any vaulting ac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90006-7

    authors: DiAngelo DJ,Winter DA,Ghista DN,Newcombe WR

    更新日期:1989-01-01 00:00:00

  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Isolated changes in femoral version do not alter intra-articular contact mechanics in cadaveric hips.

    abstract::Abnormal femoral version is a deformity in the angle between the femoral neck and the transcondylar axis of the knee. Both femoral anteversion and retroversion alter passive and active rotation of the hip and are associated with intra-articular or extra-articular impingement. However, little is known about the effect ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109891

    authors: Meyer AM,Thomas-Aitken HD,Brouillette MJ,Westermann RW,Goetz JE

    更新日期:2020-08-26 00:00:00

  • Improved walking function in laboratory does not guarantee increased community walking in stroke survivors: Potential role of gait biomechanics.

    abstract::Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.05.011

    authors: Ardestani MM,Henderson CE,Hornby TG

    更新日期:2019-06-25 00:00:00

  • Automatic selection of a representative trial from multiple measurements using Principle Component Analysis.

    abstract::Experimental data in human movement science commonly consist of repeated measurements under comparable conditions. One can face the question how to identify a single trial, a set of trials, or erroneous trials from the entire data set. This study presents and evaluates a Selection Method for a Representative Trial (SM...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.06.012

    authors: Schweizer K,Cattin PC,Brunner R,Müller B,Huber C,Romkes J

    更新日期:2012-08-31 00:00:00

  • Hip contact forces and gait patterns from routine activities.

    abstract::In vivo loads acting at the hip joint have so far only been measured in few patients and without detailed documentation of gait data. Such information is required to test and improve wear, strength and fixation stability of hip implants. Measurements of hip contact forces with instrumented implants and synchronous ana...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00040-9

    authors: Bergmann G,Deuretzbacher G,Heller M,Graichen F,Rohlmann A,Strauss J,Duda GN

    更新日期:2001-07-01 00:00:00

  • Stability basin estimates fall risk from observed kinematics, demonstrated on the Sit-to-Stand task.

    abstract::The ability to quantitatively measure stability is essential to ensuring the safety of locomoting systems. While the response to perturbation directly reflects the stability of a motion, this experimental method puts human subjects at risk. Unfortunately, existing indirect methods for estimating stability from unpertu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.022

    authors: Shia V,Moore TY,Holmes P,Bajcsy R,Vasudevan R

    更新日期:2018-04-27 00:00:00

  • Expedited patient-specific assessment of contact stress exposure in the ankle joint following definitive articular fracture reduction.

    abstract::Acute injury severity, altered joint kinematics, and joint incongruity are three important mechanical factors linked to post-traumatic osteoarthritis (PTOA). Finite element analysis (FEA) was previously used to assess the influence of increased contact stress due to joint incongruity on PTOA development. While promisi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.030

    authors: Kern AM,Anderson DD

    更新日期:2015-09-18 00:00:00

  • Novel instrumented probe for measuring 3D pressure distribution along the vaginal canal.

    abstract::We developed an intravaginal instrumented probe (covered with a 10×10 matrix of capacitive sensors) for assessing the three-dimensional (3D) spatiotemporal pressure profile of the vaginal canal. The pressure profile was compared to the pelvic floor (PF) digital assessment, and the reliability of the instrument and rep...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.035

    authors: Cacciari LP,Pássaro AC,Amorim AC,Geuder M,Sacco ICN

    更新日期:2017-06-14 00:00:00