Abstract:
:Reduced daily stepping in stroke survivors may contribute to decreased functional capacity and increased mortality. We investigated the relationships between clinical and biomechanical walking measures that may contribute to changes in daily stepping activity following physical interventions provided to participants with subacute stroke. Following ≤40 rehabilitation sessions, 39 participants were categorized into three groups: responders/retainers increased daily stepping >500 steps/day post-training (POST) without decreases in stepping at 2-6 month follow-up (F/U); responders/non-retainers increased stepping at POST but declined >500 steps/day at F/U; and, non-responders did not change daily stepping from baseline testing (BSL). Gait kinematics and kinetics were evaluated during graded treadmill assessments at BSL and POST. Clinical measures of gait speed, timed walking distance, balance and balance confidence were measured at BSL, POST and F/U. Between-group comparisons and regression analyses were conducted to predict stepping activity from BSL and POST measurements. Baseline and changes in clinical measures of walking demonstrated selective associations with stepping, although kinematic measures appeared to better discriminate responders. Specific measures suggest greater paretic vs non-paretic kinematic changes in responders with training, although greater non-paretic changes predicted greater gains (i.e., smaller declines) in stepping in retainers at F/U. No kinetic variables were primary predictors of changes in stepping activity at POST or F/U. The combined findings indicate specific biomechanical assessments may help differentiate changes in daily stepping activity post-stroke.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Ardestani MM,Henderson CE,Hornby TGdoi
10.1016/j.jbiomech.2019.05.011subject
Has Abstractpub_date
2019-06-25 00:00:00pages
151-159eissn
0021-9290issn
1873-2380pii
S0021-9290(19)30343-4journal_volume
91pub_type
杂志文章abstract::How small do pressure transducers need to be in order to faithfully measure the plantar pressure profiles (PPPs) under normal and diabetic feet? In this study, pressures were collected from five diabetic and six non-diabetic subjects using a commercial measurement system with 25 mm2 transducers. Discrete Fourier Trans...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00116-6
更新日期:1996-07-01 00:00:00
abstract::Electromagnetic tracking devices are used in many biomechanics applications. Previous studies have shown that metal located within the working field of direct current electromagnetic tracking devices produces significant errors. However, the effect of sampling rate on the errors produced in a metallic environment has ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00322-6
更新日期:2003-01-01 00:00:00
abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(99)00189-x
更新日期:2000-04-01 00:00:00
abstract::The aim of this study was to obtain insight into the coactivation behaviour of the jaw muscles under various a priori defined static loading conditions of the mandible. As the masticatory system is mechanically redundant, an infinite number of recruitment patterns is theoretically possible to produce a certain bite fo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90303-k
更新日期:1990-01-01 00:00:00
abstract::When running, energy is lost during stance to redirect the center of mass of the body (COM) from downwards to upwards. The present study uses a collision-based approach to analyze how these energy losses change with slope and speed. Therefore, we evaluate separately the average collision angle, i.e. the angle of devia...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.024
更新日期:2019-01-23 00:00:00
abstract::One of the main determinants of perfusion distribution within an organ is the structure of its vascular network. Past studies were based on angiography or corrosion casting and lacked quantitative three dimensional, 3D, representation. Based on branching rules and other properties derived from such imaging, 3D vascula...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2012.11.027
更新日期:2013-01-18 00:00:00
abstract::The advent of microelectromechanical systems (MEMS) sensors has enabled real-time wall shear stress (WSS) measurements with high spatial and temporal resolution in a 3-D bifurcation model. To optimize intravascular shear stress assessment, we evaluated the feasibility of catheter/coaxial wire-based MEMS sensors in the...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.04.021
更新日期:2009-07-22 00:00:00
abstract::In order to move the finger the tendon force must overcome the gliding resistance of the tendon as well as the forces to move the joints, finger inertias, and external load. These sources, combined, make up the work of flexion (WOF) which has been experimentally used to evaluate the finger function. In this study, we ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00300-7
更新日期:2003-02-01 00:00:00
abstract::Dynamic stabilization devices have been introduced to clinics as an alternative to rigid fixation. The stiffness of these devices varies widely, whereas the optimal stiffness, achieving a predefined stabilization of the spine, is unknown. This study was focused on the determination of stiffness values for posterior st...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.10.005
更新日期:2009-01-05 00:00:00
abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90170-4
更新日期:1988-01-01 00:00:00
abstract::The purpose of this study was to find the optimal values of design parameters for a bicycle-rider system (crank length, pelvic inclination, seat height, and rate of crank rotation) which maximize the power output from muscles of the human lower limb during bicycling. The human lower limb was modelled as a planar syste...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90322-t
更新日期:1990-01-01 00:00:00
abstract::Progress in medicine and higher expectation of quality of life has led to a higher demand for several dental and medical treatments. This increases the occurrence of situations in which orthodontic treatment is complicated by pathological conditions, medical therapies and drugs. Together with experiments, computer mod...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.10.037
更新日期:2013-02-01 00:00:00
abstract::The use of swim fins has become popular in various water sport activities. While numerous models of swim fin with various innovative shapes have been subjectively designed, the exact influence of the fin characteristics on swimming performance is still much debated, and remains difficult to quantify. To date, the most...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.03.031
更新日期:2010-07-20 00:00:00
abstract::The process of collecting ground reaction force data by mounting a forceplate beneath a treadmill belt has the advantage that numerous walking trials can be analyzed without the problem of subjects 'targeting' their footsteps. However, a potential problem is that the measured forces represent a summation of bilateral ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(93)90020-f
更新日期:1993-04-01 00:00:00
abstract::Uncrimping of collagen fibers in the arterial wall is an integral process in regulating the macro-level mechanical response of arteries. Uncrimping of collagen fibers leads to a gradual, but significant strain-stiffening response of the artery at physiological pressures and prevents overdistention at elevated pressure...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.08.001
更新日期:2013-10-18 00:00:00
abstract::The structure and function of the renal artery ostium flow diverter on the caudal side of the renal branch point were previously reported; in this study, we further evaluate the diverter׳s possible functions. The protrusion of this structure into the abdominal aorta suggests that the diverter may preferentially direct...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.006
更新日期:2014-05-07 00:00:00
abstract::Hypoplastic left heart syndrome (HLHS) represents approximately 9% of all congenital heart defects and is one of the most complex, with the left side of the heart being generally underdeveloped. Numerous studies demonstrate that intracardiac fluid flow patterns in the embryonic and fetal circulation can impact cardiac...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110035
更新日期:2020-11-09 00:00:00
abstract::The purpose of this study was to test the hypothesis that the musculotendon moment arm length is affected by the muscle anatomical cross-sectional area. The moment arm length of the triceps brachii (TB) muscle at 30°, 50°, 70°, 90°, 110° elbow flexion positions was measured in sagittal magnetic resonance images (MRI) ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.06.013
更新日期:2010-10-19 00:00:00
abstract::Tendon elasticity is important for economical locomotion; however it is unknown whether tendon stiffness is appropriate to achieve an optimal efficiency in various muscles. Here we test the hypothesis that the Achilles tendon is of an appropriate stiffness to maximise medial gastrocnemius muscle efficiency during loco...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2006.07.025
更新日期:2007-01-01 00:00:00
abstract::The purpose of this paper is to present a simple clotting model, based on residence time and shear stress distribution, that can simulate the deposition over time of enzyme-activated milk in an in vitro system. Results for the model are compared with experiments exhibiting clot deposition in the region of a sharp-edge...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.01.026
更新日期:2007-01-01 00:00:00
abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.109976
更新日期:2020-10-09 00:00:00
abstract::The purpose of this study was to clarify how foot deformation affects the relationship between triceps surae muscle-tendon unit (MTU) length and ankle joint angle. For six women and six men a series of sagittal magnetic resonance (MR) images of the right foot were taken, and changes in MTU length (the displacement of ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.003
更新日期:2011-09-23 00:00:00
abstract::The longitudinal growth of long bones occurs in growth plates where chondrocytes synthesize cartilage that is subsequently ossified. Altered growth and subsequent deformity resulting from abnormal mechanical loading is often referred to as mechanical modulation of bone growth. This phenomenon has key implications in t...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2009.05.021
更新日期:2009-08-25 00:00:00
abstract::In this review of patellofemoral joint forces as they might apply to implant design, methodologies for estimating forces on the patella and estimates of the forces, as reported in the literature, are summarized. Two methodologies exist for studying joint loads; one that measures kinematics in-vivo and uses analysis to...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2008.04.039
更新日期:2008-08-07 00:00:00
abstract::In the table contact phase of gymnastics vaulting both dynamic and static friction act. The purpose of this study was to develop a method of simulating Coulomb friction that incorporated both dynamic and static phases and to compare the results with those obtained using a pseudo-Coulomb implementation of friction when...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.022
更新日期:2011-10-13 00:00:00
abstract::Blast pulmonary trauma are common consequences of modern war and terrorism action. To better protect soldiers from that threat, the injury risk level when protected and unprotected must be assessed. Knowing from the literature that a possible amplification of the blast threat would be provided by some thoracic protect...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.02.011
更新日期:2019-03-27 00:00:00
abstract::Earlier experimental and finite element studies notwithstanding, the load transfer and stress distribution in the pelvic bone and the acetabulum in normal conditions are not well understood. This hampers the development of orthopaedic reconstruction methods. The present study deals with more precise finite element ana...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)00125-n
更新日期:1995-06-01 00:00:00
abstract::Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to expe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.02.140
更新日期:2011-05-17 00:00:00
abstract::The importance of the aortic root compliance in the aortic valve performance has most frequently been ignored in computational valve modeling, although it has a significant contribution to the functionality of the valve. Aortic root aneurysm or (calcific) stiffening severely affects the aortic valve behavior and, cons...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00448-7
更新日期:2003-05-01 00:00:00
abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90022-7
更新日期:1982-01-01 00:00:00