Influence of the renal artery ostium flow diverter on hemodynamics and atherogenesis.

Abstract:

:The structure and function of the renal artery ostium flow diverter on the caudal side of the renal branch point were previously reported; in this study, we further evaluate the diverter׳s possible functions. The protrusion of this structure into the abdominal aorta suggests that the diverter may preferentially direct blood flow to the renal arteries, and that it may also influence flow patterns and recirculation known to be involved in atherogenesis. Three-dimensional computational fluid dynamics (CFD) simulations of steady and pulsatile blood flow are performed to investigate the influence of diverter size and position, and vascular geometry, on the flow patterns and fluid mechanical forces in the neighborhood of the diverter. CFD results show that the flow diverter does affect the blood distribution; depending on the diverter׳s position, the flow to the renal arteries may be increased or reduced. Calculated results also demonstrate the diverter׳s effect on the wall shear stress (WSS) distribution, and suggest that the diverter contributes to an atherogenic environment in the abdominal aorta, while being atheroprotective in the renal arteries themselves. These results support previous clinical findings, and suggest directions for further clinical study. The results of this work have direct implications in understanding the physiological significance of the diverter, and its potential role in the pathophysiological development of atherosclerosis.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Albert S,Balaban RS,Neufeld EB,Rossmann JS

doi

10.1016/j.jbiomech.2014.03.006

subject

Has Abstract

pub_date

2014-05-07 00:00:00

pages

1594-602

issue

7

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00160-2

journal_volume

47

pub_type

杂志文章
  • Ulceration, unsteadiness, and uncertainty: the biomechanical consequences of diabetes mellitus.

    abstract::Diabetes mellitus, which results from a failure of the endocrine system to control blood glucose levels within normal limits, affects approximately 15% of the population over the age of 65 in developed countries. Between 20-50% of people with diabetes for more than 10 years will experience symmetrical distal sensory n...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/0021-9290(93)90077-r

    authors: Cavanagh PR,Simoneau GG,Ulbrecht JS

    更新日期:1993-01-01 00:00:00

  • Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines.

    abstract::The clinical relevance of mechanical testing studies of cadaveric human thoracic spines could be enhanced by using follower preload techniques, by including the intact rib cage, and by measuring thoracic intervertebral disc pressures, but studies to date have not incorporated all of these components simultaneously. Th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.02.038

    authors: Anderson DE,Mannen EM,Sis HL,Wong BM,Cadel ES,Friis EA,Bouxsein ML

    更新日期:2016-05-03 00:00:00

  • Simulation of Low Density Lipoprotein (LDL) permeation into multilayer coronary arterial wall: Interactive effects of wall shear stress and fluid-structure interaction in hypertension.

    abstract::Due to increased atherosclerosis-caused mortality, identification of its genesis and development is of great importance. Although, key factors of the origin of the disease is still unknown, it is widely believed that cholesterol particle penetration and accumulation in arterial wall is mainly responsible for further w...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.11.029

    authors: Roustaei M,Nikmaneshi MR,Firoozabadi B

    更新日期:2018-01-23 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • Microscale frictional response of bovine articular cartilage from atomic force microscopy.

    abstract::The objective of this study was to compare micro- and macroscale friction coefficients of bovine articular cartilage. Microscale measurements were performed using standard atomic force microscopy (AFM) techniques, using a 5 microm spherical probe tip. Twenty-four cylindrical osteochondral plugs were harvested in pairs...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.017

    authors: Park S,Costa KD,Ateshian GA

    更新日期:2004-11-01 00:00:00

  • Sagittal range of motion of the thoracic spine using inertial tracking device and effect of measurement errors on model predictions.

    abstract::Range of motion (ROM) of the thoracic spine has implications in patient discrimination for diagnostic purposes and in biomechanical models for predictions of spinal loads. Few previous studies have reported quite different thoracic ROMs. Total (T1-T12), lower (T5-T12) and upper (T1-T5) thoracic, lumbar (T12-S1), pelvi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.09.003

    authors: Hajibozorgi M,Arjmand N

    更新日期:2016-04-11 00:00:00

  • Does stretching velocity affect residual force enhancement?

    abstract::It is thought that the magnitude of residual force enhancement (RFE) is not affected by stretch velocity. However, the range of stretch velocities studied in previous investigations has been limited to slow and moderate velocities. High velocities of muscle stretching are associated with a loss of force and incomplete...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.033

    authors: Fukutani A,Leonard T,Herzog W

    更新日期:2019-05-24 00:00:00

  • Kinematic performance of a six degree-of-freedom hand model (6DHand) for use in occupational biomechanics.

    abstract::Upper extremity musculoskeletal disorders represent an important health issue across all industry sectors; as such, the need exists to develop models of the hand that provide comprehensive biomechanics during occupational tasks. Previous optical motion capture studies used a single marker on the dorsal aspect of finge...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.003

    authors: Buczek FL,Sinsel EW,Gloekler DS,Wimer BM,Warren CM,Wu JZ

    更新日期:2011-06-03 00:00:00

  • Measurements of the three-dimensional shape of the rib cage.

    abstract::A stereoradiographic method was developed to measure the three-dimensional shape of the rib cage in vivo in order to provide descriptive data and to study symmetry in the normal population. The method is also intended for use in description of rib asymmetry in scoliosis. Rib midlines were reconstructed from digitized ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90127-3

    authors: Dansereau J,Stokes IA

    更新日期:1988-01-01 00:00:00

  • Geometrical resolution limits and detection mechanisms in the oral cavity.

    abstract::The objective of this work is to gain more insight into the processes of oral perception of food texture. Particularly, the limits for detectable thickness differences of objects, which are evaluated in the human mouth, are investigated. In a sensory study small, flexible circular disks (diameter in mm range) of varyi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.04.012

    authors: Strassburg J,Burbidge A,Delgado A,Hartmann C

    更新日期:2007-01-01 00:00:00

  • In vivo behavior of muscle fascicles and tendinous tissues in human tibialis anterior muscle during twitch contraction.

    abstract::In this study we investigated the time course of length and velocity of muscle fascicles and tendinous tissues (TT) during isometric twitch contraction, and examined how their interaction relates to the time course of external torque and muscle fascicle force generation. From seven males, supra-maximal twitch contract...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.03.023

    authors: Oda T,Himeno R,C Hay D,Chino K,Kurihara T,Nagayoshi T,Kanehisa H,Fukunaga T,Kawakami Y

    更新日期:2007-01-01 00:00:00

  • The between-day reliability of peroneus longus EMG during walking.

    abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.037

    authors: Reeves J,Jones R,Liu A,Bent L,Nester C

    更新日期:2019-03-27 00:00:00

  • Density and hydration of fresh and fixed human skeletal muscle.

    abstract::The maximum tetanic tension of skeletal muscle (P(0)) is often estimated based on calculation of physiological cross-sectional area (PCSA). PCSA depends on muscle volume, pennation angle, and fiber length. Studies documenting PCSA in fixed human muscles usually compute muscle volume by dividing muscle mass by density....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.10.001

    authors: Ward SR,Lieber RL

    更新日期:2005-11-01 00:00:00

  • Implant size and mechanical properties influence the failure of the adhesive bond between cartilage implants and native tissue in a finite element analysis.

    abstract::Implanted cartilage replacements (ICRs) are a promising approach to restore the functionality of joints with partial- and full-thickness articular cartilage lesions. Two major hurdles hindering successful repair of cartilage injuries with ICRs are their inadequate mechanical properties and fixation into the defect are...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.03.019

    authors: Vahdati A,Wagner DR

    更新日期:2013-05-31 00:00:00

  • Influence of prosthetic humeral head size and medial offset on the mechanics of the shoulder with cuff tear arthropathy: a numerical study.

    abstract::This numerical study assesses the influence of an oversized humeral hemiprosthesis with a larger medial offset on the mechanics of the shoulder with cuff tear arthropathy (CTA). Shoulder elevation in the scapular plane is performed, and a Seebauer Type IIa CTA is simulated: a massive rotator cuff tear, a proximal and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.021

    authors: Lemieux PO,Tétreault P,Hagemeister N,Nuño N

    更新日期:2013-02-22 00:00:00

  • Morphologic adaptation of arterial endothelial cells to longitudinal stretch in organ culture.

    abstract::Arteries in vivo are subjected to large longitudinal stretch, which changes significantly due to vascular disease and surgery. However, little is known about the effect of longitudinal stretch on arterial endothelium. The aim of this study was to determine the morphologic adaptation of arterial endothelial cells (ECs)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.016

    authors: Lee YU,Drury-Stewart D,Vito RP,Han HC

    更新日期:2008-11-14 00:00:00

  • Multiple-step model-experiment matching allows precise definition of dynamical leg parameters in human running.

    abstract::The spring-loaded inverted pendulum (SLIP) model is a well established model for describing bouncy gaits like human running. The notion of spring-like leg behavior has led many researchers to compute the corresponding parameters, predominantly stiffness, in various experimental setups and in various ways. However, dif...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.030

    authors: Ludwig C,Grimmer S,Seyfarth A,Maus HM

    更新日期:2012-09-21 00:00:00

  • Fundamental role of axial stress in compensatory adaptations by arteries.

    abstract::Arteries exhibit a remarkable ability to adapt to diverse genetic defects and sustained alterations in mechanical loading. For example, changes in blood flow induced wall shear stress tend to control arterial caliber and changes in blood pressure induced circumferential wall stress tend to control wall thickness. We s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2008.11.011

    authors: Humphrey JD,Eberth JF,Dye WW,Gleason RL

    更新日期:2009-01-05 00:00:00

  • An explicit expression for the moment in multibody systems.

    abstract::The equations of motion are formulated for a set of interacting rigid bodies. An explicit formulation could be derived for the total moment of the forces on such a system. This is applied to (1) the intersegmental moment in a multisegment rigid-body model, and (2) the interpretation of the 'centre of pressure' as defi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90076-d

    authors: Hof AL

    更新日期:1992-10-01 00:00:00

  • Cervical spine morphology and ligament property variations: A finite element study of their influence on sagittal bending characteristics.

    abstract::Cervical spine finite element models reported in biomechanical literature usually represent a static morphology. Not considering morphology as a model parameter limits the predictive capabilities for applications in personalized medicine, a growing trend in modern clinical practice. The objective of the study was to i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.044

    authors: John JD,Saravana Kumar G,Yoganandan N

    更新日期:2019-03-06 00:00:00

  • Hospital bed height influences biomechanics during bed egress: A comparative controlled study of patients with Parkinson disease.

    abstract::Although a significant proportion of patient falls occur during egress from the hospital bed, the biomechanical adaptations during egress from different bed heights are still largely unknown. The purpose of this study was to evaluate the effect of hospital bed height on natural transition during egress in patients wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110116

    authors: Xu H,Li X,Shi Y,An L,Taylor D,Christman M,Morse J,Merryweather A

    更新日期:2021-01-22 00:00:00

  • A model of surfactant-induced surface tension effects on the parenchymal tethering of pulmonary airways.

    abstract::We developed a computational model of lung parenchyma, which is comprised of individual alveolar chamber models. Each alveolus is modeled by a truncated octahedron. Considering the force balance between the elastin and collagen fibers laying on the alveolar membrane and the pressures acting on the membrane, we compute...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.031

    authors: Fujioka H,Halpern D,Gaver DP 3rd

    更新日期:2013-01-18 00:00:00

  • Numerical modelling of mass transport in an arterial wall with anisotropic transport properties.

    abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.09.017

    authors: Denny WJ,Walsh MT

    更新日期:2014-01-03 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Blood and interstitial flow in the hierarchical pore space architecture of bone tissue.

    abstract::There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen an...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.013

    authors: Cowin SC,Cardoso L

    更新日期:2015-03-18 00:00:00

  • Simulating contact using the elastic foundation algorithm in OpenSim.

    abstract::Modeling joint contact in OpenSim is not well understood. This study systematically investigated the variables associated with the elastic foundation contact model within OpenSim by performing a series of controlled benchtop experiment and concomitant simulations. Four metal-on-plastic interactions were modeled, inclu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.025

    authors: Hast MW,Hanson BG,Baxter JR

    更新日期:2019-01-03 00:00:00

  • Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

    abstract::Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.028

    authors: Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

    更新日期:2017-08-16 00:00:00

  • Maximum height and minimum time vertical jumping.

    abstract::The performance criterion in maximum vertical jumping has typically been assumed to simply raise the center of mass as high as possible. In many sporting activities minimizing movement time during the jump is likely also critical to successful performance. The purpose of this study was to examine maximum height jumps ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.04.021

    authors: Domire ZJ,Challis JH

    更新日期:2015-08-20 00:00:00

  • Validity of and recommendations for knee joint acoustic assessments during different movement conditions.

    abstract::Knee joint sounds contain information on joint health, morphology and loading. These acoustic signals may be elicited by further, as yet unknown factors. By assessing potential elicitors and their relative contributions to the acoustic signal, we investigated the validity of vibroarthrographic assessments during diffe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109939

    authors: Kalo K,Niederer D,Stief F,Würzberger L,van Drongelen S,Meurer A,Vogt L

    更新日期:2020-08-26 00:00:00