Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

Abstract:

:Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdominal ultrasound imaging. Individuals with overactive bladder (OAB) underwent ultrasound imaging during filling. The fill rate was 10% of the cystometric capacity per minute as determined by an initial fill. Transabdominal ultrasound images were captured in the midsagittal and transverse planes at 1min intervals. Using image data and Pves, detrusor wall tension, stress, and compliance were calculated. From each cross-sectional image, luminal and wall areas along with inner perimeters were measured. In the sagittal and transverse planes, wall tension was calculated as Pves∗luminal area, wall stress as tension/wall area, and strain as the change in perimeter normalized to the perimeter at 10% capacity. Elastic modulus was calculated as stress/strain in the medial-lateral and cranial-caudal directions. Patient-reported fullness sensation was continuously recorded. Data from five individuals with OAB showed that detrusor wall tension, volume, and strain had the highest correlations to continuous bladder sensation of all quantities measured. This study demonstrates how detrusor wall tension, stress, strain, and elastic modulus can be quantified by adding ultrasound imaging to standard urodynamics. This technique may be useful in diagnosing and better understanding the biomechanics involved in OAB and other bladder disorders.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

doi

10.1016/j.jbiomech.2017.07.028

subject

Has Abstract

pub_date

2017-08-16 00:00:00

pages

232-241

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(17)30399-8

journal_volume

61

pub_type

杂志文章
  • Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine.

    abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.003

    authors: Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga J

    更新日期:2017-06-14 00:00:00

  • Identification of key events in baseball hitting using inertial measurement units.

    abstract::Quantification of baseball hitting mechanics under game conditions help players to become successful batters and prevent injuries. Inertial measurement units (IMUs) can measure motion without any spatial restriction and are thus becoming a popular tool to investigate sports biomechanics. Biomechanical analysis of hitt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.02.001

    authors: Punchihewa NG,Yamako G,Fukao Y,Chosa E

    更新日期:2019-04-18 00:00:00

  • A holistic approach to study the temporal variability in gait.

    abstract::Movement variability has become an important field of research and has been studied to gain a better understanding of the neuro-muscular control of human movements. In addition to studies investigating "amplitude variability" there are a growing number of studies assessing the "temporal variability" in movements by ap...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.008

    authors: Federolf P,Tecante K,Nigg B

    更新日期:2012-04-30 00:00:00

  • Non-invasive quantification of peripheral arterial volume distensibility and its non-linear relationship with arterial pressure.

    abstract::Arterial wall function is associated with different physiological and clinical factors. Changes in arterial pressure cause major changes in the arterial wall. This study presents a simple non-invasive method to quantify arterial volume distensibility changes with different arterial pressures. The electrocardiogram, fi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.02.011

    authors: Zheng D,Murray A

    更新日期:2009-05-29 00:00:00

  • Mechanical interaction of center of pressure and force direction in the upright human.

    abstract::Humans maintain upright bipedal posture by producing appropriate force against the environment through the interaction of neural controlled muscle force with the mechanics of the skeletal system. Characterizing these mechanics facilitates understanding of the neural control. We used a mechanical model of an upright hu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.03.018

    authors: Gruben KG,Boehm WL

    更新日期:2012-06-01 00:00:00

  • Coactivation of jaw muscles: recruitment order and level as a function of bite force direction and magnitude.

    abstract::The aim of this study was to obtain insight into the coactivation behaviour of the jaw muscles under various a priori defined static loading conditions of the mandible. As the masticatory system is mechanically redundant, an infinite number of recruitment patterns is theoretically possible to produce a certain bite fo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(90)90303-k

    authors: Van Eijden TM,Brugman P,Weijs WA,Oosting J

    更新日期:1990-01-01 00:00:00

  • The knee joint center of rotation is predominantly on the lateral side during normal walking.

    abstract::The purpose of this study was to test the hypothesis of whether the center of rotation (COR) in the transverse plane of the knee is in the medial side during normal walking in a manner similar to that previously described during non-ambulatory activities. The kinematics for normal knees was obtained from 46 knees duri...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.013

    authors: Koo S,Andriacchi TP

    更新日期:2008-01-01 00:00:00

  • A constitutive model for vascular tissue that integrates fibril, fiber and continuum levels with application to the isotropic and passive properties of the infrarenal aorta.

    abstract::A fundamental understanding of the mechanical properties of the extracellular matrix (ECM) is critically important to quantify the amount of macroscopic stress and/or strain transmitted to the cellular level of vascular tissue. Structural constitutive models integrate histological and mechanical information, and hence...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.07.015

    authors: Martufi G,Gasser TC

    更新日期:2011-09-23 00:00:00

  • Bi-linear mechanical property determination of acellular human patellar tendon grafts for use in anterior cruciate ligament replacement.

    abstract::Anterior cruciate ligament rupture is rising in its prevalence amongst the young and those with physically active lifestyles. Acellular human patellar tendon (PT) grafts offer a promising restoration solution, returning knee joint stability and overcoming some of the current disadvantages of autologous or allogeneic g...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.041

    authors: Herbert A,Brown C,Rooney P,Kearney J,Ingham E,Fisher J

    更新日期:2016-06-14 00:00:00

  • Evaluation of an aortic valve prosthesis: Fluid-structure interaction or structural simulation?

    abstract::Bio-inspired polymeric heart valves (PHVs) are excellent candidates to mimic the structural and the fluid dynamic features of the native valve. PHVs can be implanted as prosthetic alternative to currently clinically used mechanical and biological valves or as potential candidate for a minimally invasive treatment, lik...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.004

    authors: Luraghi G,Wu W,De Gaetano F,Rodriguez Matas JF,Moggridge GD,Serrani M,Stasiak J,Costantino ML,Migliavacca F

    更新日期:2017-06-14 00:00:00

  • Haemodynamic effects of incomplete stent apposition in curved coronary arteries.

    abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.09.016

    authors: Chen WX,Poon EKW,Thondapu V,Hutchins N,Barlis P,Ooi A

    更新日期:2017-10-03 00:00:00

  • Peristaltic transport of blood: Casson model--II.

    abstract::The problem of peristaltic transport of blood in a uniform and non-uniform tube has been investigated, under zero Reynolds number and long wavelength approximation. Blood is represented by a two-layered fluid model consisting of a central layer of suspension of all erythrocytes, etc., assumed to be a Casson fluid, and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(84)90140-4

    authors: Srivastava LM,Srivastava VP

    更新日期:1984-01-01 00:00:00

  • Some mechanical properties of goose femoral cortical bone.

    abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90108-2

    authors: McAlister GB,Moyle DD

    更新日期:1983-01-01 00:00:00

  • Sarcomere dynamics in skeletal muscle myofibrils during isometric contractions.

    abstract::The main goal of this study was to evaluate the dynamics of sarcomeres during isometric activation of skeletal muscle myofibrils. Rabbit psoas myofibrils (n=14) were attached between a pair of cantilevers for force measurements at one side and a rigid glass needle at the other side, and their images were used for meas...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.08.011

    authors: Pavlov I,Novinger R,Rassier DE

    更新日期:2009-12-11 00:00:00

  • Dynamic mechanical response of bovine gray matter and white matter brain tissues under compression.

    abstract::Dynamic responses of brain tissues are needed for predicting traumatic brain injury (TBI). We modified a dynamic experimental technique for characterizing high strain-rate mechanical behavior of brain tissues. Using the setup, the gray and white matters from bovine brains were characterized under compression to large ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.023

    authors: Pervin F,Chen WW

    更新日期:2009-04-16 00:00:00

  • A new strain energy function for the hyperelastic modelling of ligaments and tendons based on fascicle microstructure.

    abstract::A new strain energy function for the hyperelastic modelling of ligaments and tendons based on the geometrical arrangement of their fibrils is derived. The distribution of the crimp angles of the fibrils is used to determine the stress-strain response of a single fascicle, and this stress-strain response is used to det...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.031

    authors: Shearer T

    更新日期:2015-01-21 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Improving the clinical efficiency of T2(*) mapping of ligament integrity.

    abstract::Current MR methods use T2(*) relaxation time as a surrogate measure of ligament strength. Currently, a multi-echo voxel-wise least squares fit is the gold standard to create T2(*) maps; however, the post-processing is time-intensive and serves as a stopgap for clinical use. The study objective was to determine if an a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.037

    authors: Biercevicz AM,Walsh EG,Murray MM,Akelman MR,Fleming BC

    更新日期:2014-07-18 00:00:00

  • Predicting surface strains at the human distal radius during an in vivo loading task--finite element model validation and application.

    abstract::Bone strains resulting from physical activity are thought to be a primary driver of bone adaptation, but cannot be directly noninvasively measured. Because bone adapts nonuniformly, physical activity may make an important independent structural contribution to bone strength that is independent of bone mass and density...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.04.050

    authors: Bhatia VA,Edwards WB,Troy KL

    更新日期:2014-08-22 00:00:00

  • Viscoelastic properties of passive skeletal muscle in compression: stress-relaxation behaviour and constitutive modelling.

    abstract::The compressive properties of skeletal muscle are important in impact biomechanics, rehabilitation engineering and surgical simulation. However, the mechanical behaviour of muscle tissue in compression remains poorly characterised. In this paper, the time-dependent properties of passive skeletal muscle were investigat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.007

    authors: Van Loocke M,Lyons CG,Simms CK

    更新日期:2008-01-01 00:00:00

  • A comparison of convergent and bi-plane X-ray photogrammetry systems used to detect total joint loosening.

    abstract::X-ray photogrammetry is an accurate method of measuring structural displacements within the musculoskeletal system. Total joint implant alignment, migration and loosening are important clinical parameters which can be measured by X-ray photogrammetry. The purpose of this paper is to compare two different X-ray photogr...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90022-7

    authors: Lippert FG 3rd,Harrington RM,Veress SA,Fraser C,Green D,Bahniuk E

    更新日期:1982-01-01 00:00:00

  • A mechanistic damage model for ligaments.

    abstract:PURPOSE:The accuracy of biomechanical models is predicated on the realism by which they represent their biomechanical tissues. Unfortunately, most models use phenomenological ligament models that neglect the behaviour in the failure region. Therefore, the purpose of this investigation was to test whether a mechanistic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.039

    authors: Barrett JM,Callaghan JP

    更新日期:2017-08-16 00:00:00

  • The development of an improved physical surrogate model of the human spinal cord--tension and transverse compression.

    abstract::To prevent spinal cord injury, optimize treatments for it, and better understand spinal cord pathologies such as spondylotic myelopathy, the interaction between the spinal column and the spinal cord during injury and pathology must be understood. The spinal cord is a complex and very soft tissue that changes propertie...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.036

    authors: Kroeker SG,Morley PL,Jones CF,Bilston LE,Cripton PA

    更新日期:2009-05-11 00:00:00

  • A Hill type model of rat medial gastrocnemius muscle that accounts for shortening history effects.

    abstract::The aim of the present study was to develop a Hill type muscle model that accounts for the effects of shortening history. For this purpose, a function was derived that relates force depression to starting length, shortening amplitude and contraction velocity. History parameters were determined from short-range isokine...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00048-7

    authors: Meijer K,Grootenboer HJ,Koopman HF,van der Linden BJ,Huijing PA

    更新日期:1998-06-01 00:00:00

  • Material characterization of the brainstem from oscillatory shear tests.

    abstract::Traumatic damage to the brainstem occurs frequently when the brain skull complex experiences injurious loading especially during those traumatic situations that produce diffuse axonal injury (DAI). DAI has been shown to be dependent on load direction and correlated with regional tissue deformation in response to rotat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00068-2

    authors: Arbogast KB,Margulies SS

    更新日期:1998-09-01 00:00:00

  • An actuated dissipative spring-mass walking model: Predicting human-like ground reaction forces and the effects of model parameters.

    abstract::Simple models are widely used to understand the mechanics of human walking. The optimization-based minimal biped model and spring-loaded-inverted-pendulum (SLIP) model are two popular models that can achieve human-like walking patterns. However, ground reaction forces (GRF) from these two models still deviate from exp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.04.028

    authors: Li T,Li Q,Liu T

    更新日期:2019-06-11 00:00:00

  • The effect on patellofemoral joint stability of selective cutting of lateral retinacular and capsular structures.

    abstract::Patient selection for lateral retinacular release (LRR) and its efficacy are controversial. Iatrogenic medial subluxation can occur with inappropriate LRR. The aim of this study was to determine the reduction in patellofemoral stability with progressively more extensive LRR. The force required to displace the patella ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.11.003

    authors: Merican AM,Kondo E,Amis AA

    更新日期:2009-02-09 00:00:00

  • The effect of surface area digitizations on the prediction of spherical anatomical geometries for computer-assisted applications.

    abstract::Intraoperative digitization of osseous structures is an integral component of computer-assisted orthopaedic surgery. This study determined the repeatability and accuracy of predicting known radii and center locations of spherical objects for different proportions of digitized surface areas and various sphere sizes. Al...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.01.018

    authors: Whitney KD,Ferreira LM,King GJ,Johnson JA

    更新日期:2009-05-29 00:00:00

  • Muscle fatigue does not lead to increased instability of upper extremity repetitive movements.

    abstract::Muscle fatigue alters neuromuscular responses. This may lead to increased sensitivity to perturbations and possibly to subsequent injury risk. We studied the effects of muscle fatigue on movement stability during a repetitive upper extremity task. Twenty healthy young subjects performed a repetitive work task, similar...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.11.001

    authors: Gates DH,Dingwell JB

    更新日期:2010-03-22 00:00:00

  • Elastic area compressibility of the rabbit aorta.

    abstract::In this paper, we apply the micropipette to reduce the surface area of the rabbit aorta, and the relationship between the fractional area change of the aortic surface and the negative pressure in the pipette is studied. The experimental results for seven rabbit thoracic aortas show that the relationship can be express...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(96)00003-6

    authors: Yu Q,Wang X,Li G

    更新日期:1996-08-01 00:00:00