Abstract:
:Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoracic and cervical regions of the human spine, obtained through detailed dissection of an embalmed male cadaver. We divided the muscles into a number of muscle-tendon elements, digitized their attachments at the bones, and measured morphological muscle parameters. In total, 225 muscle elements were measured over 39 muscles. For every muscle element, we provide the coordinates of its attachments, fiber length, tendon length, sarcomere length, optimal fiber length, pennation angle, mass, and physiological cross-sectional area together with the skeletal geometry of the cadaver. Results were consistent with similar anatomical studies. Furthermore, we report new data for several muscles such as rotatores, multifidus, levatores costarum, spinalis, semispinalis, subcostales, transversus thoracis, and intercostales muscles. This dataset complements our previous study where we presented a consistent dataset for the lumbar region of the spine (Bayoglu et al., 2017). Therefore, when used together, these datasets enable a complete and coherent dataset for the entire spine. The complete dataset will be used to develop a musculo-skeletal model for the entire human spine to study clinical and ergonomic applications.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga Jdoi
10.1016/j.jbiomech.2017.04.003subject
Has Abstractpub_date
2017-06-14 00:00:00pages
52-63eissn
0021-9290issn
1873-2380pii
S0021-9290(17)30200-2journal_volume
58pub_type
杂志文章abstract::Understanding proximal femur fracture may yield new targets for fracture prevention screening and treatment. The goal of this study was to characterize force-displacement and failure behaviours in the proximal femur between displacement control and impact loading fall simulations. Twenty-one human proximal femurs were...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.06.040
更新日期:2014-11-28 00:00:00
abstract::This study was aimed at investigating the intersegmental coordination of six older adults while managing unexpected slippages delivered during steady walking, and wearing an Active Pelvis Orthosis (APO). The APO was setup either to assist volunteers at the hip levels during balance loss or to be transparent. The Plana...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.01.003
更新日期:2019-03-06 00:00:00
abstract::In the context of reconciling the mechanical properties of trabecular bone measured from in vitro mechanical testing with the true in situ behavior, recent attention has focused on the "side-artifact" which results from interruption of the trabecular network along the sides of machined specimens. The objective of this...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.008
更新日期:2007-01-01 00:00:00
abstract::Incomplete stent apposition (ISA, also known as malapposition) is a complication that affects day-to-day coronary stenting procedures. ISA is more prominent in complex arterial geometries, such as curvature, asa result of the limited conformability of coronary stents. These malapposed struts disturb the otherwise near...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.016
更新日期:2017-10-03 00:00:00
abstract::This work proposes a real-time monitoring tool aimed to support clinicians for remote assessing exercise performances during home-based rehabilitation. The study relies on clinician indications to define kinematic features, that describe five motor tasks (i.e., the lateral tilt of the trunk, lifting of the arms, trunk...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.008
更新日期:2018-03-01 00:00:00
abstract::Foot ulceration is a diabetic complication estimated to result in over $1 billion worth of medical expenses per year in the United States alone. This multifaceted problem involves the response of plantar soft tissue to both external forces applied to the epidermis and internal changes such as vascular supply and neuro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.001
更新日期:2006-01-01 00:00:00
abstract::Although arterio-venous grafts (AVGs) represent the second choice as permanent vascular access for hemodialysis, this solution is still affected by a relevant failure rate due to graft thrombosis, and development of neointimal hyperplasia (IH) at the distal vein. As a key role in these processes has been attributed to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109591
更新日期:2020-02-13 00:00:00
abstract::Falls cause 95% of hip and wrist fractures and 60% of head injuries in older adults. Risk for such injuries depends in part on velocity at contact, and the time available during the fall to generate protective responses. However, we have no information on the impact velocities and durations of falls in older adults. W...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.02.025
更新日期:2015-04-13 00:00:00
abstract::Wheelchair-dependent subjects often adopt a passive sitting posture and suffer from sitting acquired pressure ulcers (PU) that mainly occur when high buttock pressures sustain for a longer period of time. Body posture directly influences seating load and proper postural change is therefore essential. Many subjects can...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.04.012
更新日期:2008-07-19 00:00:00
abstract::Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approx...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00434-7
更新日期:2003-03-01 00:00:00
abstract::Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to expe...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.02.140
更新日期:2011-05-17 00:00:00
abstract::Nanoindentation has been widely used as a means to measure the micro-mechanical properties of bone and to predict the macroscopic properties. The role of indent depth and indenter tip geometry in measuring the hierarchical properties of bone tissue was explored experimentally using a range of spherical indenter tips o...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.10.008
更新日期:2011-01-11 00:00:00
abstract::Gravity is a contributing force that is believed to influence strongly the control of limb movements since it affects sensory input and also contributes to task mechanics. By altering the relative contribution of gravitational force to the overall forces used to control pedaling at different body orientations, we test...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(96)00038-3
更新日期:1996-10-01 00:00:00
abstract::We proposed a velocity control strategy for dynamic posture determination that underlay an optimization-based differential inverse kinematics (ODIK) approach for modeling three-dimensional (3-D) seated reaching movements. In this modeling approach, a four-segment seven-DOF linkage is employed to represent the torso an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00117-1
更新日期:1998-11-01 00:00:00
abstract::This paper has three purposes. (1) To verify an error formula from which the maximal precision in derivatives obtained from noisy measurement data can be calculated. The formula is verified by comparison with the resulting noise in derivatives obtained by local least squares polynomial fitting. It is also verified tha...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(82)90082-3
更新日期:1982-01-01 00:00:00
abstract::Cellular mechanics is known to play an important role in many cellular functions including adhesion, migration, proliferation, and differentiation. Human mesenchymal stem cells (hMSCs) demonstrate unique mechanical properties distinct from fully differentiated cells. This observation suggests that the stem cell mechan...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.07.024
更新日期:2011-10-13 00:00:00
abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90312-5
更新日期:1987-01-01 00:00:00
abstract::Medical professionals, physical therapists, product designers, and computational models all use cervical spine range of motion reference values. To support these functions, researchers have collected a plethora of data to determine the normal range of motion of the cervical spine of adult subjects. However, little to ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.06.021
更新日期:2008-08-28 00:00:00
abstract::Subchondral bone microdamage due to high-impact loading is a key factor leading to post-traumatic knee osteoarthritis. A quantified assessment of the mechanical characteristics of subchondral bone at the tissue-level is essential to study the mechanism of impact-induced microdamage. We combined mechanical impact testi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.05.016
更新日期:2016-07-05 00:00:00
abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2003.09.034
更新日期:2004-06-01 00:00:00
abstract::Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction of density in bone surrounding the implant. This effect can be related to the weakness of the implant fixation, which can promote implant loosening. Several studies describe ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.09.048
更新日期:2010-02-10 00:00:00
abstract::A computational model of adaptive bone remodelling is formulated as an optimization problem of instantaneous changes in microstructure that minimize a functional describing the structure quality rate. Microstructure is locally described by a set of scalar geometric parameters. Macroscopic (continuum) elastic propertie...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.09.045
更新日期:2010-02-10 00:00:00
abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...
journal_title:Journal of biomechanics
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.jbiomech.2019.109579
更新日期:2020-02-13 00:00:00
abstract::Hemodynamics factors and biomechanical forces play key roles in atherogenesis, plaque development and final rupture. In this paper, we investigated the flow field and stress field for different degrees of stenoses under physiological conditions. Disease is modelled as axisymmetric cosine shape stenoses with varying di...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.06.023
更新日期:2007-01-01 00:00:00
abstract::Stress relaxation experiments were performed on specimens from a human intervertebral disc. Specimens were made from the nucleus pulposus and from the external lamellae of the anulus fibrosus in two different orientations. Tests were run with varying moisture content so as to develop a relaxation master curve. A model...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90144-8
更新日期:1987-01-01 00:00:00
abstract::There is a growing appreciation of the profound effects that passive mechanical properties, especially the stiffness of the local environment, can have on cellular functions. Many experiments are conducted in a 2D geometry (i.e., cells grown on top of substrates of varying stiffness), which is a simplification of the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.02.012
更新日期:2009-05-29 00:00:00
abstract::Side-cutting is commonly used to evaluate knee joint kinematics and kinetics in the context of anterior cruciate ligament injury risk. Many existing side-cutting studies fail to clearly define the orientation of the femoral frame and the knee axis, making comparisons between studies difficult. A femoral frame construc...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.05.017
更新日期:2012-07-26 00:00:00
abstract::Fixation failure of glenoid components is the main cause of unsuccessful total shoulder arthroplasties. The characteristics of these failures are still not well understood, hence, attempts at improving the implant fixation are somewhat blind and the failure rate remains high. This lack of understanding is largely due ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.10.019
更新日期:2010-03-03 00:00:00
abstract::The purpose of this study was to gain an improved understanding of the mechanical behavior of the intervertebral disc in the presence and absence of the vertebral endplates. Mechanical behaviors of rat caudal motion segments, vertebrae and isolated disc explants under two different permeability conditions were investi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.11.013
更新日期:2007-01-01 00:00:00
abstract::The objective assessment of biomechanical asymmetries during movement tasks is used to monitor rehabilitation following anterior cruciate ligament reconstruction (ACLR). Marker placement is an important source of methodological variability within human motion analysis. It is currently unclear how marker placement erro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110184
更新日期:2020-12-24 00:00:00