Comparison of blood particle deposition models for non-parallel flow domains.

Abstract:

:Adhesions of monocytes and platelets to a vascular surface, particularly in regions of flow stagnation, recirculation, and reattachment, are a significant initial event in a broad spectrum of particle-wall interactions that significantly influence the formation of stenotic lesions and mural thrombi. A number of approximations are available for the simulation of both monocyte and platelet interactions with the vascular surface. For the simulation of blood particle adhesion, this study hypothesizes that: (a) the discrete element approach, which accounts for finite particle size and inertia, is advantageous in the context of non-parallel flow domains including stagnation, recirculation, and reattachment; and (b) the likelihood for particle deposition may be effectively approximated as being non-linearly proportional to local particle concentration, residence time, and wall proximity. Models such as wall shear stress correlations, the multicomponent mixture approach, and Lagrangian particle tracking with and without hydrodynamic particle-wall interactions were evaluated. Quantitative performance of the selected models was established by comparisons to available experimental data sets for non-parallel axisymmetric suspension flows of monocytes and platelets. Factors including the convective-diffusive transport of particles, finite particle size and inertia, as well as near-wall hydrodynamic interactions were found to significantly influence blood particle deposition. Of the models studied, the near-wall residence time approach was found to be a particularly effective indicator for the deposition of monocytes (r2=0.74) and platelets (r2=0.57), given that nano-scale physical and biochemical effects must be greatly approximated in computational simulations involving relatively large-scale geometries and complex flow fields.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Worth Longest P,Kleinstreuer C

doi

10.1016/s0021-9290(02)00434-7

keywords:

subject

Has Abstract

pub_date

2003-03-01 00:00:00

pages

421-30

issue

3

eissn

0021-9290

issn

1873-2380

pii

S0021929002004347

journal_volume

36

pub_type

杂志文章
  • Mechanical properties of rat thoracic and abdominal aortas.

    abstract::Mechanical properties of abdominal and thoracic arteries of 2mm in diameter were determined from adults Wistar rats. A tensile testing instrument was used to obtain stress/strain curves with arteries immersed in physiological buffer at 37 degrees C. A displacement was applied on all arteries with various frequencies (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.04.017

    authors: Assoul N,Flaud P,Chaouat M,Letourneur D,Bataille I

    更新日期:2008-07-19 00:00:00

  • Analysis of thoracic aorta hemodynamics using 3D particle tracking velocimetry and computational fluid dynamics.

    abstract::Parallel to the massive use of image-based computational hemodynamics to study the complex flow establishing in the human aorta, the need for suitable experimental techniques and ad hoc cases for the validation and benchmarking of numerical codes has grown more and more. Here we present a study where the 3D pulsatile ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.06.017

    authors: Gallo D,Gülan U,Di Stefano A,Ponzini R,Lüthi B,Holzner M,Morbiducci U

    更新日期:2014-09-22 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Evaluation of human nasal cartilage nonlinear and rate dependent mechanical properties.

    abstract::Nasal reconstruction frequently requires donor cartilage and tissue, and ideally, donor tissue will closely emulate native nasal cartilage mechanics. Tissue engineering scaffolds, especially 3D printed scaffolds, have been proposed for nasal reconstruction, and the success of these constructs may depend on how well sc...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109549

    authors: Chang B,Reighard C,Flanagan C,Hollister S,Zopf D

    更新日期:2020-02-13 00:00:00

  • A physiological approach to the simulation of bone remodeling as a self-organizational control process.

    abstract::Although the capacity of bone to adapt to functional mechanical requirements has been known for more than a century, it is still unclear how the bone adaptation processes are regulated. We hypothesize that osteocytes are sensitive to mechanical loading and control the regulation of bone mass in their environment. Rece...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90049-3

    authors: Mullender MG,Huiskes R,Weinans H

    更新日期:1994-11-01 00:00:00

  • Impact responses of the cervical spine: A computational study of the effects of muscle activity, torso constraint, and pre-flexion.

    abstract::Cervical spine injuries continue to be a costly societal problem. Future advancements in injury prevention depend on improved physical and computational models, which are predicated on a better understanding of the neck response during dynamic loading. Previous studies have shown that the tolerance of the neck is depe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.006

    authors: Nightingale RW,Sganga J,Cutcliffe H,Bass CR

    更新日期:2016-02-29 00:00:00

  • Instantaneous helical axis estimation from 3-D video data in neck kinematics for whiplash diagnostics.

    abstract::To date, the diagnosis of whiplash injuries has been very difficult and largely based on subjective, clinical assessment. The work by Winters and Peles Multiple Muscle Systems--Biomechanics and Movement Organization. Springer, New York (1990) suggests that the use of finite helical axes (FHAs) in the neck may provide ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90192-9

    authors: Woltring HJ,Long K,Osterbauer PJ,Fuhr AW

    更新日期:1994-12-01 00:00:00

  • Characterization of polyvinyl alcohol hydrogels as tissue-engineered cartilage scaffolds using a coupled finite element-optimization algorithm.

    abstract::Mechanical strength along with high biocompatibility and water absorbing are among main characteristics of a desirable scaffold for cartilage tissue engineering. Having these properties, polyvinyl alcohol (PVA) can be a good option for constructing cartilage tissue engineering scaffolds. In this study, PVA hydrogel wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109525

    authors: Nazouri M,Seifzadeh A,Masaeli E

    更新日期:2020-01-23 00:00:00

  • Representative 3D shape of the distal femur, modes of variation and relationship with abnormality of the trochlear region.

    abstract::The anatomy of the distal femur has a predominant influence on the mechanics of both patello- and tibio-femoral joints. Especially, the morphological degeneration of the trochlear region dramatically affects the overall knee biomechanics and, from a clinical point of view, the staging of such a degeneration is fundame...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.008

    authors: Cerveri P,Belfatto A,Manzotti A

    更新日期:2019-09-20 00:00:00

  • Cost-effective (gaming) motion and balance devices for functional assessment: Need or hype?

    abstract::In the last decade, technological advances in the gaming industry have allowed the marketing of hardware for motion and balance control that is based on technological concepts similar to scientific and clinical equipment. Such hardware is attractive to researchers and clinicians for specific applications. However, som...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.07.011

    authors: Bonnechère B,Jansen B,Van Sint Jan S

    更新日期:2016-09-06 00:00:00

  • Patterns in the knee flexion-extension moment profile during stair ascent and descent in patients with total knee arthroplasty.

    abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.026

    authors: McClelland JA,Feller JA,Menz HB,Webster KE

    更新日期:2014-06-03 00:00:00

  • The selection of a standard convention for analyzing gait data based on the analysis of relevant biomechanical factors.

    abstract::The gait cycle is usually analyzed using one of two conventions: heel contact initiates the cycle and stance is followed by swing phases or toe-off initiates the cycle and swing then stance phases are analyzed. The purpose of the study is to demonstrate that based on a consideration of relevant biomechanical measures,...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90025-6

    authors: DeVita P

    更新日期:1994-04-01 00:00:00

  • An in vitro model for the pathological degradation of articular cartilage in osteoarthritis.

    abstract::The objective of this study was to develop an in vitro cartilage degradation model that emulates the damage seen in early-stage osteoarthritis. To this end, cartilage explants were collagenase-treated to induce enzymatic degradation of collagen fibers and proteoglycans at the articular surface. To assess changes in me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.050

    authors: Grenier S,Bhargava MM,Torzilli PA

    更新日期:2014-02-07 00:00:00

  • Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging.

    abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110085

    authors: Namiranian B,Jerban S,Ma Y,Dorthe EW,Masoud-Afsahi A,Wong J,Wei Z,Chen Y,D'Lima D,Chang EY,Du J

    更新日期:2020-12-02 00:00:00

  • Effect of LIMK2 RNAi on reorganization of the actin cytoskeleton in osteoblasts induced by fluid shear stress.

    abstract::The biomechanical characteristics of bone tissue and its cells under mechanical stress are significant for bone biomechanics research, but the mechanism of mechanotransduction is still unknown. It has been established that the actin cytoskeleton of osteoblasts plays an important role in this process. However, the stru...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.010

    authors: Fu Q,Wu C,Shen Y,Zheng S,Chen R

    更新日期:2008-11-14 00:00:00

  • An ultrasound based non-invasive method for the measurement of intrinsic foot kinematics during gait.

    abstract::Soft tissue artefact (STA) and marker placement variability are sources of error when measuring the intrinsic kinematics of the foot. This study aims to demonstrate a non-invasive, combined ultrasound and motion capture (US/MC) technique to directly measure foot skeletal motion. The novel approach is compared to a sta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.12.014

    authors: Telfer S,Woodburn J,Turner DE

    更新日期:2014-03-21 00:00:00

  • Control of cellular adhesion and myofibroblastic character with sub-micrometer magnetoelastic vibrations.

    abstract::The effect of sub-cellular mechanical loads on the behavior of fibroblasts was investigated using magnetoelastic (ME) materials, a type of material that produces mechanical vibrations when exposed to an external magnetic AC field. The integration of this functionality into implant surfaces could mitigate excessive fib...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.02.007

    authors: Holmes HR,Vlaisavljevich E,Tan EL,Snyder KL,Ong KG,Rajachar RM

    更新日期:2018-04-11 00:00:00

  • The role of elastin and collagen in the softening behavior of the human thoracic aortic media.

    abstract::In a previous study we were able to accurately fit experimental data on arterial tissues at supra-physiological loads using a material model that accounts for softening/damage only in the portion of the model associated with the collagen fibers (Weisbecker et al., 2012). Naturally, this result leads to the hypothesis ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.04.025

    authors: Weisbecker H,Viertler C,Pierce DM,Holzapfel GA

    更新日期:2013-07-26 00:00:00

  • Assessment of wavelet analysis of gait in children with typical development and cerebral palsy.

    abstract::The objective of this study was to examine the use of the continuous wavelet transform (CWT) on surface electromyographic (sEMG) signals acquired from the lower extremity muscles during gait in children with typical development (TD) and cerebral palsy (CP). This was done to explore the possibility of developing a quan...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.002

    authors: Lauer RT,Stackhouse C,Shewokis PA,Smith BT,Orlin M,McCarthy JJ

    更新日期:2005-06-01 00:00:00

  • Gait variability magnitude but not structure is altered in essential tremor.

    abstract::Essential tremor (ET) is a common tremor disorder affecting postural/action tremor of the upper extremities and midline. Recent research revealed a cerebellar-like deficit during tandem gait in persons with ET, though spatiotemporal variability during normal gait in ET has been relatively ignored. The first purpose of...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2013.07.039

    authors: Roemmich RT,Zeilman PR,Vaillancourt DE,Okun MS,Hass CJ

    更新日期:2013-10-18 00:00:00

  • Mass, center of mass, and moment of inertia estimates for infant limb segments.

    abstract::To quantify limb dynamics, accurate estimates are needed of anthropometric inertia parameters (mass, center-of-mass location, and moments of inertia). These estimates, however, are not available for human infants; therefore, the movement dynamics of infants have not been studied extensively. Here, regression equations...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90271-2

    authors: Schneider K,Zernicke RF

    更新日期:1992-02-01 00:00:00

  • Patient-specific bone modelling and remodelling simulation of hypoparathyroidism based on human iliac crest biopsies.

    abstract::We previously developed a load-adaptive bone modelling and remodelling simulation model that can predict changes in the bone micro-architecture as a result of changes in mechanical loading or cell activity. In combination with a novel algorithm to estimate loading conditions, this offers the possibility for patient-sp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.06.031

    authors: Christen P,Ito K,Müller R,Rubin MR,Dempster DW,Bilezikian JP,van Rietbergen B

    更新日期:2012-09-21 00:00:00

  • High frequency components of bone strain in dogs measured during various activities.

    abstract::Rubin et al. [J. Biomechanics 23, 43-54 (1990)] proposed that high frequency bone strains in the 15-30 Hz range might have significant influence on the morphological adaptation of bone tissue. We sought to further their findings by determining the magnitude of high frequency strains during various activities. We measu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)80005-0

    authors: Turner CH,Yoshikawa T,Forwood MR,Sun TC,Burr DB

    更新日期:1995-01-01 00:00:00

  • Effect of implementing magnetic resonance imaging for patient-specific OpenSim models on lower-body kinematics and knee ligament lengths.

    abstract:BACKGROUND:OpenSim models are typically based on cadaver findings that are generalized to represent a wide range of populations, which curbs their validity. Patient-specific modelling through incorporating magnetic resonance imaging (MRI) improves the model's biofidelity with respect to joint alignment and articulation...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.11.016

    authors: Smale KB,Conconi M,Sancisi N,Krogsgaard M,Alkjaer T,Parenti-Castelli V,Benoit DL

    更新日期:2019-01-23 00:00:00

  • Comparison of micro-level and continuum-level voxel models of the proximal femur.

    abstract::Continuum-level finite element (FE) models became standard computational tools for the evaluation of bone mechanical behavior from in vivo computed tomography scans. Such scans do not account for the anisotropy of the bone. Instead, local mechanical properties in the continuum-level FE models are assumed isotropic and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.10.027

    authors: Verhulp E,van Rietbergen B,Huiskes R

    更新日期:2006-01-01 00:00:00

  • Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound.

    abstract::Overactive bladder is often characterized by biomechanical changes in the bladder wall, but there is no established method to measure these changes in vivo. The goal of this study was to develop a novel method to determine detrusor wall biomechanical parameters during urodynamics through the incorporation of transabdo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.07.028

    authors: Nagle AS,Klausner AP,Varghese J,Bernardo RJ,Colhoun AF,Barbee RW,Carucci LR,Speich JE

    更新日期:2017-08-16 00:00:00

  • Experimental measurement and quantification of frictional contact between biological surfaces experiencing large deformation and slip.

    abstract::Interactions between contacting biological surfaces may play significant roles in physiological and pathological processes. Theoretical models have described some special cases of contact, using one or more simplifying assumptions. Experimental quantification of contact could help to validate theoretical analyses. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.01.006

    authors: Gratz KR,Sah RL

    更新日期:2008-01-01 00:00:00

  • Measurements of active myocardial tension under a wide range of physiological loading conditions.

    abstract::Active tension developed while cardiac muscle shortens has been studied extensively under afterloaded isotonic or isovelocity conditions. However, these are not true in vivo loading conditions. To obtain more physiological loading, we controlled sarcomere length to follow the time courses that we observed previously i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(96)00122-4

    authors: Guccione JM,Le Prell GS,de Tombe PP,Hunter WC

    更新日期:1997-02-01 00:00:00

  • The vesico-urethral pressuregram analysis of urethral function under stress.

    abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)81291-2

    authors: Kim KJ,Ashton-Miller JA,Strohbehn K,DeLancey JO,Schultz AB

    更新日期:1997-01-01 00:00:00

  • Effect of geometrical imperfections in confined compression tests on parameter evaluation of hydrated soft tissues.

    abstract::Experimental tests, such as the confined and unconfined compression and the indentation tests, are traditionally used to determine the poroelastic properties of hydrated soft tissues (HSTs). The purpose of this study was to quantitatively evaluate the reliability of H(A) and K values as identified from experimental co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.020

    authors: Gervaso F,Pennati G,Boschetti F

    更新日期:2007-01-01 00:00:00