Comparison of micro-level and continuum-level voxel models of the proximal femur.

Abstract:

:Continuum-level finite element (FE) models became standard computational tools for the evaluation of bone mechanical behavior from in vivo computed tomography scans. Such scans do not account for the anisotropy of the bone. Instead, local mechanical properties in the continuum-level FE models are assumed isotropic and are derived from bone density, using statistical relationships. Micro-FE models, on the other hand, incorporate the anisotropic structure in detail. This study aimed to quantify the effects of assumed isotropy, by comparing continuum-level voxel models of a healthy and a severely osteoporotic proximal femur with recently analyzed micro-FE models of the same bones. The micro-model element size was coarsened to generate continuum FE models with two different element sizes (0.64 and 3.04 mm) and two different density-modulus relationships found in the literature for wet and ash density. All FE models were subjected to the same boundary conditions that simulated a fall to the side, and the stress and strain distributions, model stiffness and yield load were compared. The results indicated that the stress and strain distributions could be reproduced well with the continuum models. The smallest differences between the continuum-level model and micro-level model predictions of the stiffness and yield load were obtained with the coarsest element size. Better results were obtained for both continuum-element sizes when isotropic moduli were based on ash density rather than wet density.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Verhulp E,van Rietbergen B,Huiskes R

doi

10.1016/j.jbiomech.2005.10.027

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

2951-7

issue

16

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(05)00486-0

journal_volume

39

pub_type

杂志文章
  • Patterns in the knee flexion-extension moment profile during stair ascent and descent in patients with total knee arthroplasty.

    abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.03.026

    authors: McClelland JA,Feller JA,Menz HB,Webster KE

    更新日期:2014-06-03 00:00:00

  • Analysis of the musculoskeletal loading of the thumb during pipetting--a pilot study.

    abstract::Previous epidemiological studies indicate that the use of thumb-push mechanical pipettes is associated with musculoskeletal disorders (MSDs) in the hand. The goal of the current study was to analyze the loading in the muscle-tendon units in the thumb during pipetting. The hand is modeled as a multi-body linkage system...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.015

    authors: Wu JZ,Sinsel EW,Shroyer JF,Warren CM,Welcome DE,Zhao KD,An KN,Buczek FL

    更新日期:2014-01-22 00:00:00

  • Development of biomechanical response corridors of the thorax to blunt ballistic impacts.

    abstract::Human responses are critical to understanding injury biomechanics in blunt ballistic impacts, which are defined as 20-200 g projectiles impacting at 20-250 m/s. 13 human cadavers were exposed to three distinct ballistic impacts of the chest to determine force-time, deflection-time and force-deflection responses. Compa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00238-0

    authors: Bir C,Viano D,King A

    更新日期:2004-01-01 00:00:00

  • Evaluation of residual stresses due to bone callus growth: a computational study.

    abstract::Mechanical environment in callus is determinant for the evolution of bone healing. However, recent mechanobiological computational works have underestimated the effect that growth exerts on the mechanical environment of callus. In the present work, we computationally evaluate the significance of growth-induced stresse...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.04.021

    authors: González-Torres LA,Gómez-Benito MJ,García-Aznar JM

    更新日期:2011-06-03 00:00:00

  • Acquisition of full-field strain distributions on ovine fracture callus cross-sections with electronic speckle pattern interferometry.

    abstract::This study evaluated the feasibility of assessing continuous strain distributions on fracture callus cross-sections with an electronic speckle pattern interferometry (ESPI) system. Mid-sagittal callus cross-sections were harvested from ovine tibiae. One low stiffness (LS) specimen and one high stiffness (HS) specimen ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.10.024

    authors: Bottlang M,Mohr M,Simon U,Claes L

    更新日期:2008-01-01 00:00:00

  • Growth and surface folding of esophageal mucosa: a biomechanical model.

    abstract::Mucosal folding in such biological vessels as esophagus and airway is essential to their physiological functions and can be affected by some diseases, e.g., inflammation, edema, lymphoma, and asthma. A biomechanical model within the framework of finite deformation theory is proposed to address the mucosal folding indu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.007

    authors: Li B,Cao YP,Feng XQ

    更新日期:2011-01-04 00:00:00

  • Use of a statistical model of the whole femur in a large scale, multi-model study of femoral neck fracture risk.

    abstract::Interpatient variability is often overlooked in orthopaedic computational studies due to the substantial challenges involved in sourcing and generating large numbers of bone models. A statistical model of the whole femur incorporating both geometric and material property variation was developed as a potential solution...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.05.038

    authors: Bryan R,Nair PB,Taylor M

    更新日期:2009-09-18 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Assessment of intersegmental coordination of rats during walking at different speeds - Application of continuous relative phase.

    abstract::The present study investigated the feasibility and reliability of continuous relative phase (CRP) and deviation phase (DP) to assess intersegmental hind limb coordination pattern and coordination variability in rats during walking. Twenty-six adult rats walked at 8 m/min, 12 m/min and 16 m/min while two-dimensional ki...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.03.045

    authors: Raffalt PC,Nielsen LR,Madsen S,Højberg LM,Pingel J,Nielsen JB,Alkjær T,Wienecke J

    更新日期:2018-05-17 00:00:00

  • Dynamic interactions between lumbar intervertebral motion segments during forward bending and return.

    abstract::Continuous dynamic multi-segmental studies of lumbar motion have added depth to our understanding of the biomechanics of back pain, but few have attempted to continuously measure the proportions of motion accepted by individual levels. This study attempted to compare the motion contributions of adjacent lumbar levels ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109603

    authors: Breen A,Breen A

    更新日期:2020-03-26 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • Friction in metal-on-metal total disc arthroplasty: effect of ball radius.

    abstract::Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.045

    authors: Moghadas P,Mahomed A,Hukins DW,Shepherd DE

    更新日期:2012-02-02 00:00:00

  • Using directional statistics to test hypotheses regarding rigid body attitude: Comparison to univariate and multivariate Cardan angle tests.

    abstract::Rigid body attitude and single-joint kinematics are typically expressed using three Cardan angles which represent rotations in anatomical planes. It was recently shown in the Biomechanics literature that Cardan angles inaccurately estimate true mean attitude due to an important mathematical inadequacy: attitude under-...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109976

    authors: Pataky TC,Challis JH

    更新日期:2020-10-09 00:00:00

  • Experimentally verified mathematical approach for the prediction of force developed by motor units at variable frequency stimulation patterns.

    abstract::During normal daily activity, muscle motor units (MUs) develop unfused tetanic contractions evoked by trains of motoneuronal firings at variable interpulse intervals (IPIs). The mechanical responses of a MU to successive impulses are not identical. The aim of this study was to develop a mathematical approach for the p...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.034

    authors: Raikova R,Rusev R,Drzymała-Celichowska H,Krutki P,Aladjov H,Celichowski J

    更新日期:2010-05-28 00:00:00

  • Confocal-based cell-specific finite element modeling extended to study variable cell shapes and intracellular structures: the example of the adipocyte.

    abstract::This communication extends the recently reported cell-specific finite element (FE) method in Slomka and Gefen (2010) in which geometrically realistic FE cell models are created from confocal microscopy scans for large deformation analyses. The cell-specific FE method is extended here in the following aspects: (i) we d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.09.012

    authors: Or-Tzadikario S,Gefen A

    更新日期:2011-02-03 00:00:00

  • A sensitive data analysis approach for detecting changes in dynamic postural stability.

    abstract::Understanding the mechanisms of instability can aid in reducing fall risk. As a sensitive measure of fall risk, the distance between the center of pressure (COP) and center of mass (COM) is currently assessed through discrete points assumed to represent physiological important fall mechanisms. However, it is unclear i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109899

    authors: Moudy SC,Patterson RM,Bugnariu N

    更新日期:2020-07-17 00:00:00

  • An experimental setup for the measurement of forces on a human cadaveric foot during inversion.

    abstract::An experimental setup was developed for statically measuring seven vertical and three horizontal reaction forces on the foot. In the setup, the leg can be simultaneously loaded (1) by a vertical force, (2) by an externally applied axial moment, and (3) by simulated muscle forces. The foot is free to invert under influ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(89)90080-8

    authors: Ottevanger EJ,Spoor CW,van Leeuwen JL,Sauren AA,Janssen JD,Huson A

    更新日期:1989-01-01 00:00:00

  • Collagen fibril D-period may change as a function of strain and location in ligament.

    abstract::The purpose of this study was to determine if the characteristic banding pattern (D-period) of collagen fibrils from rabbit medial collateral ligaments changes as a function of gross ligament strain and, if so, whether the changes are location dependent (insertion versus midsubstance). Femur-medial collateral ligament...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00150-0

    authors: Kukreti U,Belkoff SM

    更新日期:2000-12-01 00:00:00

  • A telemetry-based device to determine the force-displacement behaviour of materials in high impact loading situations.

    abstract::Meaningful testing of stab resistant body armour requires the use of realistic body tissue simulants. A device for the determination of the force-displacement behaviour of materials in high impact loading situations has been developed for the testing of such simulants. Force measurement is achieved with the use of ele...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00191-8

    authors: Chadwick EK,Nicol AC,Floyd S,Gray TG

    更新日期:2000-03-01 00:00:00

  • Using force sensing insoles to predict kinetic knee symmetry during a stop jump.

    abstract::Knee kinetic asymmetries are present during jump-landings in athletes returning to sport following anterior cruciate ligament (ACL) reconstruction, and are associated with an increased risk for sustaining a second ACL injury. The loadsol® is a wireless load sensing insole that can be used in non-laboratory settings. T...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.07.037

    authors: Peebles AT,Ford KR,Taylor JB,Hart JM,Sands LP,Queen RM

    更新日期:2019-10-11 00:00:00

  • An instrumented tissue tester for measuring soft tissue property under the metatarsal heads in relation to metatarsophalangeal joint angle.

    abstract::Identification of the localized mechanical response of the plantar soft tissue pads underneath the metatarsal heads (i.e., sub-MTH pad) to external loading is key to understand and predict how it functions in a gait cycle. The mechanical response depends on various parameters, such as the external load (direction and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.031

    authors: Chen WM,Phyau-Wui Shim V,Park SB,Lee T

    更新日期:2011-06-03 00:00:00

  • Direct calculation of the surface-to-volume ratio for human cancellous bone.

    abstract::There are many diseases which cause detrimental changes in the trabecular structure of cancellous bone, leading to mechanical failure of the tissue. One approach to understanding the mechanisms of these diseases is to create idealized models that recreate the morphology of the tissue. This paper presents a partial dev...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(93)90057-l

    authors: Fyhrie DP,Fazzalari NL,Goulet R,Goldstein SA

    更新日期:1993-08-01 00:00:00

  • Biomechanical comparison of the human cadaveric pelvis with a fourth generation composite model.

    abstract::The use of cadavers for orthopaedic biomechanics research is well established, but presents difficulties to researchers in terms of cost, biosafety, availability, and ease of use. High fidelity composite models of human bone have been developed for use in biomechanical studies. While several studies have utilized comp...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.12.050

    authors: Girardi BL,Attia T,Backstein D,Safir O,Willett TL,Kuzyk PR

    更新日期:2016-02-29 00:00:00

  • The nature of the stabilizing functions of skeletal muscles.

    abstract::The paper defines the term coordination interval (CI), suggesting that it should replace the term electromechanical delay (EMD), if this parameter is determined in vivo for a muscle functioning in a biomechanical system with considerable mobility, but not in a kinematic pair with one degree of rotational freedom (DOF)...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)90211-9

    authors: Kornecki S,Zschorlich V

    更新日期:1994-02-01 00:00:00

  • The impact of boundary conditions on surface curvature of polypropylene mesh in response to uniaxial loading.

    abstract::Exposure following pelvic organ prolapse repair has been observationally associated with wrinkling of the implanted mesh. The purpose of this study was to quantify the impact of variable boundary conditions on the out-of-plane deformations of mesh subjected to tensile loading. Using photogrammetry and surface curvatur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.061

    authors: Barone WR,Amini R,Maiti S,Moalli PA,Abramowitch SD

    更新日期:2015-06-25 00:00:00

  • A method to estimate the elastic properties of the extracellular matrix of articular cartilage.

    abstract::In this work we propose a method to estimate the elastic properties of the extracellular matrix of articular cartilage, once the elastic properties of the chondrocytes and the whole tissue are known. The influence of the elastic properties of the tissue and the cell concentration on the estimated elastic properties of...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00280-x

    authors: Federico S,Herzog W,Wu JZ,La Rosa G

    更新日期:2004-03-01 00:00:00

  • Circumferentially flexible vascular grafts.

    abstract::An arterial graft with a corrugated cylindrical cross-section has been proposed as a partial solution to the problem of elastic stiffness mismatch between conventional grafts and arterial tissue (Trescony et al., 1994, US Patent 5,282, 847 (granted February 1 1994)). A two-dimensional ring theory model and a finite el...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00084-0

    authors: Stump DM,Hart VG,Tuttle SL

    更新日期:1998-08-01 00:00:00

  • Generating dynamic simulations of movement using computed muscle control.

    abstract::Computation of muscle excitation patterns that produce coordinated movements of muscle-actuated dynamic models is an important and challenging problem. Using dynamic optimization to compute excitation patterns comes at a large computational cost, which has limited the use of muscle-actuated simulations. This paper int...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00432-3

    authors: Thelen DG,Anderson FC,Delp SL

    更新日期:2003-03-01 00:00:00

  • Musculoskeletal stiffness changes linearly in response to increasing load during walking gait.

    abstract::Development of biologically inspired exoskeletons to assist soldiers in carrying load is a rapidly expanding field. Understanding how the body modulates stiffness in response to changing loads may inform the development of these exoskeletons and is the purpose of the present study. Seventeen subjects walked on a tread...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.046

    authors: Caron RR,Lewis CL,Saltzman E,Wagenaar RC,Holt KG

    更新日期:2015-04-13 00:00:00

  • Correlates between kinematics and baropodometric measurements for an integrated in-vivo assessment of the segmental foot function in gait.

    abstract::Baropodometry and multi-segmental foot kinematics are frequently employed to obtain insight into the mechanics of the foot-ground interaction in both basic research and clinical settings. However, nothing hitherto has been reported on the full integration of kinematics with baropodometric parameters, and only a few st...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.05.014

    authors: Giacomozzi C,Leardini A,Caravaggi P

    更新日期:2014-08-22 00:00:00