The nature of the stabilizing functions of skeletal muscles.

Abstract:

:The paper defines the term coordination interval (CI), suggesting that it should replace the term electromechanical delay (EMD), if this parameter is determined in vivo for a muscle functioning in a biomechanical system with considerable mobility, but not in a kinematic pair with one degree of rotational freedom (DOF). It was adopted that CI is the time elapsing between the moment of exertion of the resultant muscular force to the surroundings by the ending of the biokinematic chain with many DOFs, and the onset of myopotential in the muscle involved in its actuation. Tested at the same time was the utility efficiency of the system: man--unstable external object with adjustable mobility, as well as the participation and coordination patterns of the upper extremity muscles engaged in stabilizing and motor activities. Twelve adult men, students of physical education, took part in the experiment. The experimental set-up was in the form of a 3.08 m long physical pendulum with the inertial moment of 574 kg m2 and with an exchangeable ending that served as a handle. Three endings were used with zero, one or two DOFs in relation to the pendulum shaft. The subjects of the test were told to push the pendulum ending with maximum force using the upper extremity, so as to impart to it the highest possible kinetic energy, irrespective of its stability type and mobility. The muscles straightening the upper extremity and stabilizing the wrist joint were tested in the EMG measurements. As a result of the experiment, it was found that (1) the utility efficiency of the organism in relation to the force and muscular power exerted on the surroundings decreases to 80 and 60%, respectively, if a driven object requires stabilization, and (2) the patterns of muscular synergism expressed by sequences and frequencies of muscular activation by the nervous system, on the grounds of CI, undergo characteristic changes if a driven object becomes unstable.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kornecki S,Zschorlich V

doi

10.1016/0021-9290(94)90211-9

subject

Has Abstract

pub_date

1994-02-01 00:00:00

pages

215-25

issue

2

eissn

0021-9290

issn

1873-2380

pii

0021-9290(94)90211-9

journal_volume

27

pub_type

杂志文章
  • Force response of the fingertip pulp to repeated compression--effects of loading rate, loading angle and anthropometry.

    abstract::Repeated loading of the fingertips has been postulated to contribute to tendon and nerve disorders at the wrist during activities associated with prolonged fingertip loading such as typing. To fully understand the pathomechanics of these soft tissue disorders, the role of the fingertip pulp in attenuating the applied ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(97)00065-1

    authors: Serina ER,Mote CD Jr,Rempel D

    更新日期:1997-10-01 00:00:00

  • A novel validation and calibration method for motion capture systems based on micro-triangulation.

    abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.009

    authors: Nagymáté G,Tuchband T,Kiss RM

    更新日期:2018-06-06 00:00:00

  • Right ventricle in hypoplastic left heart syndrome exhibits altered hemodynamics in the human fetus.

    abstract::Hypoplastic left heart syndrome (HLHS) represents approximately 9% of all congenital heart defects and is one of the most complex, with the left side of the heart being generally underdeveloped. Numerous studies demonstrate that intracardiac fluid flow patterns in the embryonic and fetal circulation can impact cardiac...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110035

    authors: Zebhi B,Wiputra H,Howley L,Cuneo B,Park D,Hoffman H,Gilbert L,Yap CH,Bark D Jr

    更新日期:2020-11-09 00:00:00

  • Reprogramming cardiomyocyte mechanosensing by crosstalk between integrins and hyaluronic acid receptors.

    abstract::The elastic modulus of bioengineered materials has a strong influence on the phenotype of many cells including cardiomyocytes. On polyacrylamide (PAA) gels that are laminated with ligands for integrins, cardiac myocytes develop well organized sarcomeres only when cultured on substrates with elastic moduli in the range...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.023

    authors: Chopra A,Lin V,McCollough A,Atzet S,Prestwich GD,Wechsler AS,Murray ME,Oake SA,Kresh JY,Janmey PA

    更新日期:2012-03-15 00:00:00

  • Sticky chain model for shear response of red blood cells.

    abstract::A sticky chain model has been proposed to describe the unfolding of spectrin network under applied mechanical loads. With the model, the response of a red blood cell (RBC) under static and cyclic shear loading has been predicted, which agrees qualitatively with relevant experimental results. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.028

    authors: Huang GY,Mai YW

    更新日期:2008-08-07 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • A survey of micro-finite element analysis for clinical assessment of bone strength: the first decade.

    abstract::Micro-Finite Element (micro-FE) analysis is now widely used in biomedical research as a tool to derive bone mechanical properties as they relate to its microstructure. With the development of in vivo high-resolution peripheral quantitative CT (HR-pQCT) scanners, it can now be applied to analyze bone in-vivo in the per...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.12.024

    authors: van Rietbergen B,Ito K

    更新日期:2015-03-18 00:00:00

  • Effect of temperature on residual force enhancement in single skeletal muscle fibers.

    abstract::It is well accepted that the steady-state isometric force following active stretching of a muscle is greater than the steady-state isometric force obtained in a purely isometric contraction at the same length. This property of skeletal muscle has been called residual force enhancement (FE). Despite decades of research...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.007

    authors: Lee EJ,Herzog W

    更新日期:2008-08-28 00:00:00

  • Micromechanics modeling of Haversian cortical bone properties.

    abstract::A finite-element micromechanics model for Haversian cortical bone tissue has been developed and studied. The model is an extension of two-dimensional micromechanics techniques for fiber-reinforced composite materials. Haversian systems, or secondary osteons, are considered to be the fiber component, and interstitial l...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90095-i

    authors: Hogan HA

    更新日期:1992-05-01 00:00:00

  • Balance control in stepping down expected and unexpected level changes.

    abstract::Stepping down an elevation in ongoing gait is a common task that can cause falls when the level change is unexpected. The aim of this study was to compare expected and unexpected stepping down. We hypothesized that unexpected stepping would lead to loss of control over the movement and potentially falls due to bucklin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.06.009

    authors: van Dieën JH,Spanjaard M,Konemann R,Bron L,Pijnappels M

    更新日期:2007-01-01 00:00:00

  • Synthesis and characterisation of core-shell structures for orthopaedic surgery.

    abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.05.002

    authors: Rusen E,Zaharia C,Zecheru T,Mărculescu B,Filmon R,Chappard D,Bădulescu R,Cincu C

    更新日期:2007-01-01 00:00:00

  • Computational musculoskeletal modeling of compensatory movements in the upper limb.

    abstract::It is well documented that most upper limb amputees utilize compensatory movement strategies to accomplish everyday tasks when using a prosthetic device and that musculoskeletal complaints (MSCs) are more common in this population. However, little information is available on how the loss of distal degrees of freedom (...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109843

    authors: Reilly M,Kontson K

    更新日期:2020-07-17 00:00:00

  • A new strain energy function for the hyperelastic modelling of ligaments and tendons based on fascicle microstructure.

    abstract::A new strain energy function for the hyperelastic modelling of ligaments and tendons based on the geometrical arrangement of their fibrils is derived. The distribution of the crimp angles of the fibrils is used to determine the stress-strain response of a single fascicle, and this stress-strain response is used to det...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.11.031

    authors: Shearer T

    更新日期:2015-01-21 00:00:00

  • Hydro-mechanical coupling in the periodontal ligament: a porohyperelastic finite element model.

    abstract::Harmonic tension-compression tests at 0.1, 0.5 and 1 Hz on hydrated bovine periodontal ligament (PDL) were numerically simulated. The process was modeled by finite elements (FE) within the framework of poromechanics, with the objective of isolating the contributions of the solid- and fluid phases. The solid matrix was...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.08.019

    authors: Bergomi M,Cugnoni J,Galli M,Botsis J,Belser UC,Wiskott HW

    更新日期:2011-01-04 00:00:00

  • Finding and defining the ideal patellar resection plane in total knee arthroplasty.

    abstract::Asymmetric resection of the patella during total knee arthroplasty (TKA) correlates with anterior knee pain, bony impingement and patellar maltracking. Despite this, there is no consensus regarding the desired landmarks; the cut is often done freehand; and there has been no quantitative comparison of proposed resectio...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2009.06.021

    authors: Anglin C,Fu C,Hodgson AJ,Helmy N,Greidanus NV,Masri BA

    更新日期:2009-10-16 00:00:00

  • Automatic selection of a representative trial from multiple measurements using Principle Component Analysis.

    abstract::Experimental data in human movement science commonly consist of repeated measurements under comparable conditions. One can face the question how to identify a single trial, a set of trials, or erroneous trials from the entire data set. This study presents and evaluates a Selection Method for a Representative Trial (SM...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2012.06.012

    authors: Schweizer K,Cattin PC,Brunner R,Müller B,Huber C,Romkes J

    更新日期:2012-08-31 00:00:00

  • Regional dependency of the vascular smooth muscle cell contribution to the mechanical properties of the pig ascending aortic tissue.

    abstract:BACKGROUND:Dilation and dissection of aneurysmal ascending aortic tissues occur preferentially at the outer curvature of the vessel. In this study we hypothesize that the density and contractile properties of the vascular smooth muscle cells (VSMCs) of the pig ascending aorta (AA) are heterogeneous and could explain th...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.04.018

    authors: Tremblay D,Cartier R,Mongrain R,Leask RL

    更新日期:2010-08-26 00:00:00

  • Compressive strain rate sensitivity of ballistic gelatin.

    abstract::Gelatin is a popular tissue simulant used in biomedical applications. The uniaxial compressive stress-strain response of gelatin was determined at a range of strain rates. In the quasistatic regime, gelatin strength remained relatively constant. With increase in loading rate, the compressive strength increased from 3k...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.008

    authors: Kwon J,Subhash G

    更新日期:2010-02-10 00:00:00

  • Shank and rearfoot coordination and its variability during running in flatfoot.

    abstract::Flatfoot is a risk factor for patellofemoral pain syndrome (PFPS), and excessive rearfoot eversion occurring in flatfoot has been associated with the development and progression of PFPS; however, the mechanism remains unclear. This study aimed to investigate transverse shank and frontal rearfoot coordination patterns ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110119

    authors: Takabayashi T,Edama M,Inai T,Kubo M

    更新日期:2021-01-22 00:00:00

  • A new in vivo technique for determination of 3D kinematics and contact areas of the patello-femoral and tibio-femoral joint.

    abstract::Patello-femoral disorders are often caused by changes of patello-femoral and/or tibio-femoral kinematics. However, until now there has been no quantitative in vivo technique, that is able to obtain 3D kinematics and contact areas of all knee compartments simultaneously on a non-invasive basis. The aim of this study wa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.09.034

    authors: von Eisenhart-Rothe R,Siebert M,Bringmann C,Vogl T,Englmeier KH,Graichen H

    更新日期:2004-06-01 00:00:00

  • Posture shifting after spinal cord injury using functional neuromuscular stimulation--a computer simulation study.

    abstract::The ability for individuals with spinal cord injury (SCI) to affect changes in standing posture with functional neuromuscular stimulation (FNS) was explored using an anatomically inspired musculoskeletal model of the trunk, pelvis and lower extremities (LE). The model tracked trajectories for anteriorly and laterally ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.12.020

    authors: Audu ML,Nataraj R,Gartman SJ,Triolo RJ

    更新日期:2011-06-03 00:00:00

  • Fluid load support during localized indentation of cartilage with a spherical probe.

    abstract::Interstitial fluid pressurization, a consequence of a biphasic tissue structure, is essential to the load bearing and lubrication properties of articular cartilage. Focal tissue degradation may interfere with this protective mechanism, eventually leading to gross degeneration and osteoarthritis. Our long-term goal is ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.12.019

    authors: Bonnevie ED,Baro VJ,Wang L,Burris DL

    更新日期:2012-04-05 00:00:00

  • Muscle activity reduces soft-tissue resonance at heel-strike during walking.

    abstract::Muscle activity has previously been suggested to minimize soft-tissue resonance which occurs at heel-strike during walking and running. If this concept were true then the greatest vibration damping would occur when the input force was closest to the resonant frequency of the soft-tissues at heel-strike. However, this ...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0021-9290(03)00216-1

    authors: Wakeling JM,Liphardt AM,Nigg BM

    更新日期:2003-12-01 00:00:00

  • Fluid flow in bone in vitro.

    abstract::Recent dielectric measurements suggest that the electromechanical effect in wet (fluid saturated) bone is not due to a piezoelectric effect. This would imply that the electromechanical effect observed in wet bone is due to a streaming potential and is therefore dependent on fluid flow in stressed bone. A model for flu...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(82)90054-9

    authors: Johnson MW,Chakkalakal DA,Harper RA,Katz JL,Rouhana SW

    更新日期:1982-01-01 00:00:00

  • Revolutionizing orthopaedic biomaterials: The potential of biodegradable and bioresorbable magnesium-based materials for functional tissue engineering.

    abstract::In recent years, there has been a surge of interest in magnesium (Mg) and its alloys as biomaterials for orthopaedic applications, as they possess desirable mechanical properties, good biocompatibility, and biodegradability. Also shown to be osteoinductive, Mg-based materials could be particularly advantageous in func...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章,评审

    doi:10.1016/j.jbiomech.2013.12.003

    authors: Farraro KF,Kim KE,Woo SL,Flowers JR,McCullough MB

    更新日期:2014-06-27 00:00:00

  • The effect of shortening history on isometric and dynamic muscle function.

    abstract::Despite numerous reports on isometric force depression, few reports have quantified force depression during active muscle shortening (dynamic force depression). The purpose of this investigation was to determine the influence of shortening history on isometric force following active shortening, force during isokinetic...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.10.041

    authors: McDaniel J,Elmer SJ,Martin JC

    更新日期:2010-03-03 00:00:00

  • Mechanical characterization of liver capsule through uniaxial quasi-static tensile tests until failure.

    abstract::Accidentology data showed that liver is often injured in car crashes; three types of injuries occur: hematoma, laceration and vessel failure. This paper focuses on surface laceration, which involves liver capsule and hepatic parenchyma. Liver capsule behavior has been studied but its failure properties are still uncle...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.038

    authors: Brunon A,Bruyère-Garnier K,Coret M

    更新日期:2010-08-10 00:00:00

  • Variability observed in mechano-regulated in vivo tissue differentiation can be explained by variation in cell mechano-sensitivity.

    abstract::Computational simulations of tissue differentiation have been able to capture the main aspects of tissue formation/regeneration observed in animal experiments-except for the considerable degree of variability reported. Understanding and modelling the source of this variability is crucial if computational tools are to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.003

    authors: Khayyeri H,Checa S,Tägil M,Aspenberg P,Prendergast PJ

    更新日期:2011-04-07 00:00:00

  • Aerodynamic study of different cyclist positions: CFD analysis and full-scale wind-tunnel tests.

    abstract::Three different cyclist positions were evaluated with Computational Fluid Dynamics (CFD) and wind-tunnel experiments were used to provide reliable data to evaluate the accuracy of the CFD simulations. Specific features of this study are: (1) both steady Reynolds-averaged Navier-Stokes (RANS) and unsteady flow modellin...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.01.025

    authors: Defraeye T,Blocken B,Koninckx E,Hespel P,Carmeliet J

    更新日期:2010-05-07 00:00:00

  • Sensitivity of flow patterns in aneurysms on the anterior communicating artery to anatomic variations of the cerebral arterial network.

    abstract::Recent studies raised increasing concern about the reliability of computer models in reproducing in vivo hemodynamics in cerebral aneurysms. Boundary condition problem is among the most frequently addressed issues since three-dimensional (3-D) modeling is usually restricted to local arterial segments. The present stud...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.09.031

    authors: Liang F,Liu X,Yamaguchi R,Liu H

    更新日期:2016-11-07 00:00:00