Abstract:
:A sticky chain model has been proposed to describe the unfolding of spectrin network under applied mechanical loads. With the model, the response of a red blood cell (RBC) under static and cyclic shear loading has been predicted, which agrees qualitatively with relevant experimental results.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Huang GY,Mai YWdoi
10.1016/j.jbiomech.2008.05.028subject
Has Abstractpub_date
2008-08-07 00:00:00pages
2349-52issue
11eissn
0021-9290issn
1873-2380pii
S0021-9290(08)00282-0journal_volume
41pub_type
杂志文章abstract::Three different cyclist positions were evaluated with Computational Fluid Dynamics (CFD) and wind-tunnel experiments were used to provide reliable data to evaluate the accuracy of the CFD simulations. Specific features of this study are: (1) both steady Reynolds-averaged Navier-Stokes (RANS) and unsteady flow modellin...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.01.025
更新日期:2010-05-07 00:00:00
abstract::The purpose of the present study was to investigate the effects of mechanical strain, anisotropy, and tissue region on electrical conductivity and ion diffusivity in meniscus fibrocartilage. A one-dimensional, 4-wire conductivity experiment was employed to measure the electrical conductivity in porcine meniscus tissue...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.06.011
更新日期:2016-09-06 00:00:00
abstract::None of the physical testing, nor the goniometers currently used to assess upper limb function have a high validity, sensitivity or reliability. The reachable workspace, i.e. the area covered by the farthest points a subject can reach by hand without moving his/her body, shows promise but has yet to be validated, part...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.12.010
更新日期:2018-02-08 00:00:00
abstract::Spinal intervertebral joints are complex structures allowing motion in multiple directions, and many experimental studies have reported moment-rotation response. However, experimental methods, reporting of results, and levels of the spine tested vary widely, and a comprehensive assessment of moment-rotation response a...
journal_title:Journal of biomechanics
pub_type: 杂志文章,meta分析,评审
doi:10.1016/j.jbiomech.2019.109579
更新日期:2020-02-13 00:00:00
abstract::The aim of this study was to investigate the prevalence of abnormal knee biomechanical patterns in 40 patients with a modern TKA prosthesis, compared to 40 matched control participants when ascending and descending stairs. Fewer patients were able to ascend (65%) or descend stairs (53%) unassisted than controls (83%)....
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.03.026
更新日期:2014-06-03 00:00:00
abstract::Bone is a biological nanocomposite composed primarily of collagen and hydroxyapatite. The collagen molecules self-assemble to from a structure known as a fibril that comprises of about 85-95% of the total bone protein. In a fibril, the molecular level interactions at the interface between molecular collagen and hydrox...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2010.02.027
更新日期:2010-06-18 00:00:00
abstract::Low back pain (LBP) affects many individuals worldwide. The established association between LBP and spine motor control has led to the development of many control assessment techniques. To understand spine control and LBP, it is essential to know the relationship between assessment techniques. Systems identification (...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.109344
更新日期:2019-11-11 00:00:00
abstract::The objective assessment of biomechanical asymmetries during movement tasks is used to monitor rehabilitation following anterior cruciate ligament reconstruction (ACLR). Marker placement is an important source of methodological variability within human motion analysis. It is currently unclear how marker placement erro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110184
更新日期:2020-12-24 00:00:00
abstract::The effect of non-habitual physical activity on bone architecture in the rat humeral shaft was examined. Two groups of rats were trained to swim for 1 h a day, for 20 weeks, at two training levels. The control group consisted of sedentary rats. Parameters of cross-sectional bone morphology (cross-section areas, princi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90068-7
更新日期:1989-01-01 00:00:00
abstract::This paperwork deals with the obtaining and characterisation of new acrylic cements for bone surgery. The final mixture of cement contains derivatives of methacryloyloxyethyl phosphate, methacrylic acid or 2-acrylamido-2-methyl-1-propane sulphonic acid. The idea of using these monomers is sustained by their ability to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2007.05.002
更新日期:2007-01-01 00:00:00
abstract::The aim of this study was to investigate whether elimination of multifidus muscle in rats causes intervertebral disc (IVD) degeneration similar to that found after IVD lesion. Data were obtained from 36 male Wistar rats randomly assigned to one of three groups: (i) IVD lesion, in which the L4/L5 IVD was stabbed; (ii) ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.01.004
更新日期:2018-03-21 00:00:00
abstract::In this study, an experimental framework is described that allows pressurization of intact, human atherosclerotic carotid samples (inflation testing), in combination with ultrasound imaging. Eight fresh human carotid endarterectomy samples were successfully pressurized and tested. About 36 2-D (+t) ultrasound datasets...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.01.016
更新日期:2014-03-03 00:00:00
abstract::In this paper we present a study of the post valvular flow field on a new cardiovascular simulator including an elastic model of the aortic arch. Transverse and vertical two-dimensional velocity measurements are performed with an ultrasonic velocimeter. Two prosthetic heart valves are tested in the aortic position. Th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(85)90054-5
更新日期:1985-01-01 00:00:00
abstract::Simulating and analysing eye movement is useful for assessing visual system contribution to discomfort with respect to body movements, especially in virtual environments where simulation sickness might occur. It can also be used in the design of eye prosthesis or humanoid robot eye. In this paper, we present two biome...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.02.006
更新日期:2018-04-11 00:00:00
abstract::Low-back load during manual lifting is considered an important risk factor for the occurrence of low-back pain. Splitting a load, so it can be lifted beside the body (one load in each hand), instead of in front of the body, can be expected to reduce low-back load. Twelve healthy young men lifted 10 and 20-kg wide and ...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2008.10.013
更新日期:2009-01-05 00:00:00
abstract::Torsion is an important testing modality commonly used to calculate structural properties of long bones. However, the effects of size and geometry must be excluded from the overall structural response in order to compare material properties of bones of different size, age and species. We have developed a new method to...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2009.04.019
更新日期:2009-08-07 00:00:00
abstract::About one-third of older multiparous women are prone to stress urinary incontinence (SUI): unwanted urine loss during activities which suddenly raise intra-abdominal pressure. In this paper we describe and test a method for visualizing and analyzing the function of the urinary continence control system (CCS) under str...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(97)81291-2
更新日期:1997-01-01 00:00:00
abstract::A two-dimensional, five-muscle model was used to determine the degree of precision required for accurate calculation of temporomandibular joint force magnitude and direction. The sensitivity of the calculations to each variable were assessed by incrementing each variable through its presumed biological range and were ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(89)90206-6
更新日期:1989-01-01 00:00:00
abstract::Porcine bioprosthesis were treated with 0.625% glutaraldehyde and stabilized under changing pressure from 4 to 30 mmHg. Bovine pericardium and 12 biovalves (of age between 14 days and 80 months) after implantation in the human body were investigated (7 porcine PB and 5 pericardial bioprosthesis--PCB). Circumferential ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(94)90027-2
更新日期:1994-01-01 00:00:00
abstract::Engineering of large articular cartilage tissue constructs remains a challenge as tissue growth is limited by nutrient diffusion. Here, a novel strategy is investigated, generating large constructs through the assembly of individually cultured, interlocking, smaller puzzle-shaped subunits. These constructs can be engi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.01.023
更新日期:2016-03-21 00:00:00
abstract::Formation of restrictive adhesions is one of the main obstacles in rehabilitation following hand surgery. Most experimental work, however, involves only a macroscopic and/or histologic evaluation of the amount of adhesions, and their functional characteristics are poorly described. The aim of this study was to develop...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90171-i
更新日期:1991-01-01 00:00:00
abstract::It has long been thought that intracranial saccular aneurysms enlarge and rupture because of mechanical instabilities. Recent nonlinear analyses suggest, however, that at least certain sub-classes of aneurysms do not exhibit quasi-static limit point instabilities or dynamic instabilities in response to periodic loadin...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(03)00083-6
更新日期:2003-08-01 00:00:00
abstract::Refractures and secondary fractures occur after removal of internal fixation devices even when the X-rays show well-mineralized bony unions. This indicates the unreliability of bone density as the only parameter to estimate the strength of healing bone. The aim of this study was to show that the strength of healing bo...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00006-4
更新日期:1995-11-01 00:00:00
abstract::In this study, a three-dimensional finite element model was used to investigate the changes in tissue composition and mechanical signals within human lumbar intervertebral disc during the degenerative progression. This model was developed based on the cell-activity coupled mechano-electrochemical mixture theory. The d...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.09.004
更新日期:2014-11-28 00:00:00
abstract::Mechanical properties of skeletal muscles are often studied for controlled, electrically induced, maximal, or supra-maximal contractions. However, many mechanical properties, such as the force-length relationship and force enhancement following active muscle stretching, are quite different for maximal and sub-maximal,...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.12.002
更新日期:2007-01-01 00:00:00
abstract::The second part of this study of the six axes of head motion caused by translational seat vibration is concerned with the effect of fore-and-aft (x-axis) and lateral (y-axis) seat vibration. Seat-to-head transmissibilities have been determined at frequencies up to 16 Hz for each of the three translational and three ro...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(88)90170-4
更新日期:1988-01-01 00:00:00
abstract::Seated ergometer pedaling is a motor task ideal for studying basic mechanisms of human bipedal coordination because, in contrast to standing and walking, fewer degrees of freedom are being controlled and upright balance is not a factor. As a step toward understanding how individual muscles coordinate pedaling, we inve...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(95)00011-9
更新日期:1996-01-01 00:00:00
abstract::Identification of kinetic variables in different masks of foot is important for the evaluation and treatment of chronic low back pain. The aim of this study was to investigate the effect of chronic idiopathic low back pain on kinetic variables of gait in different foot masks. 11 idiopathic chronic low back pain patien...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.08.013
更新日期:2018-10-05 00:00:00
abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110085
更新日期:2020-12-02 00:00:00
abstract::Bone has the ability to adapt its structure in response to the mechanical environment as defined as Wolff's Law. The alignment of trabecular structure is intended to adapt to the particular mechanical milieu applied to it. Due to the absence of normal mechanical loading, it will be extremely important to assess the an...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.04.022
更新日期:2012-06-26 00:00:00