Compensation for inertial and gravity effects in a moving force platform.

Abstract:

:Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled surface movements, or in conditions where the foundation is moving or not sufficiently rigid. Here we present a linear model to predict the inertial and gravitational artifacts using accelerometer signals. The model is first calibrated with data collected from random movements of the unloaded system and then used to compensate for the errors in another trial. The method was tested experimentally on an instrumented force treadmill capable of dynamic mediolateral translation and sagittal pitch. The compensation was evaluated in five experimental conditions, including platform motions induced by actuators, by motor vibration, and by human ground reaction forces. In the test that included all sources of platform motion, the root-mean-square (RMS) errors were 39.0 N and 15.3 N m in force and moment, before compensation, and 1.6 N and 1.1 N m, after compensation. A sensitivity analysis was performed to determine the effect on estimating joint moments during human gait. Joint moment errors in hip, knee, and ankle were initially 53.80 N m, 32.69 N m, and 19.10 N m, and reduced to 1.67 N m, 1.37 N m, and 1.13 N m with our method. It was concluded that the compensation method can reduce the inertial and gravitational artifacts to an acceptable level for human gait analysis.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Hnat SK,van Basten BJH,van den Bogert AJ

doi

10.1016/j.jbiomech.2018.05.009

subject

Has Abstract

pub_date

2018-06-25 00:00:00

pages

96-101

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(18)30357-9

journal_volume

75

pub_type

杂志文章
  • Serial manipulator functional calibration for in vitro biomechanical testing.

    abstract::Serial manipulators are often used in biomechanical testing of human joints because they are precise, repeatable instruments that can create interesting loading scenarios. Unfortunately, commercial serial manipulators often do not have acceptable global positional accuracy due to manufacturing tolerances, assembly err...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.017

    authors: Hill I,Banks S

    更新日期:2014-01-03 00:00:00

  • Theoretical study of intracellular stress fiber orientation under cyclic deformation.

    abstract::We studied stress fiber orientation under a wide range of uniaxial cyclic deformations. We devised and validated a hypothesis consisting of two parts, as follows: (1) a stress fiber aligns to avoid a mechanical stimulus in the fiber direction under cyclic deformation. This means that, among all allowable directions, a...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(00)00114-7

    authors: Yamada H,Takemasa T,Yamaguchi T

    更新日期:2000-11-01 00:00:00

  • Knee joint biomechanics of patients with unilateral total knee arthroplasty during stationary cycling.

    abstract::Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The pur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110111

    authors: Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang S

    更新日期:2021-01-22 00:00:00

  • Towards the modelling of ageing and atherosclerosis effects in ApoE(-/-) mice aortic tissue.

    abstract::The goal of this work consists in a quantitative analysis and constitutive modelling of ageing processes associated to plaque formation in mice arteries. Reliable information on the characteristic evolution of pressure-stretch curves due to the ageing effects is extracted from previous inflation test experiments. Furt...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.01.043

    authors: Waffenschmidt T,Cilla M,Sáez P,Pérez MM,Martínez MA,Menzel A,Peña E

    更新日期:2016-08-16 00:00:00

  • Twente spine model: A complete and coherent dataset for musculo-skeletal modeling of the thoracic and cervical regions of the human spine.

    abstract::Musculo-skeletal modeling could play a key role in advancing our understanding of the healthy and pathological spine, but the credibility of such models are strictly dependent on the accuracy of the anatomical data incorporated. In this study, we present a complete and coherent musculo-skeletal dataset for the thoraci...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.04.003

    authors: Bayoglu R,Geeraedts L,Groenen KHJ,Verdonschot N,Koopman B,Homminga J

    更新日期:2017-06-14 00:00:00

  • A new system for analyzing swim fin propulsion based on human kinematic data.

    abstract::The use of swim fins has become popular in various water sport activities. While numerous models of swim fin with various innovative shapes have been subjectively designed, the exact influence of the fin characteristics on swimming performance is still much debated, and remains difficult to quantify. To date, the most...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.03.031

    authors: Nicolas G,Bideau B,Bideau N,Colobert B,Le Guerroue G,Delamarche P

    更新日期:2010-07-20 00:00:00

  • Hemodynamic insight into overlapping bare-metal stents strategy in the treatment of aortic aneurysm.

    abstract::Clinical trials have shown overlapping bare-metal stents provoke effective thrombus clot within the aneurysm sac and shrinkage of the aneurysm by directly regulating the hemodynamics. To gain insight into the hemodynamic mechanism of the technique, three cases of simplified thoracic aortic aneurysm models (with no ste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.03.028

    authors: Zhang P,Liu X,Sun A,Fan Y,Deng X

    更新日期:2015-07-16 00:00:00

  • Biomechanical analysis of the stance phase during barefoot and shod running.

    abstract::This study investigated spatio-temporal variables, ground reaction forces and sagittal and frontal plane kinematics during the stance phase of nine trained subjects running barefoot and shod at three different velocities (3.5, 4.5, 5.5 m s(-1)). Differences between conditions were detected with the general linear meth...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00192-x

    authors: De Wit B,De Clercq D,Aerts P

    更新日期:2000-03-01 00:00:00

  • Influence of erythrocyte aggregation on radial migration of platelet-sized spherical particles in shear flow.

    abstract::Blood platelets when activated are involved in the mechanisms of hemostasis and thrombosis, and their migration toward injured vascular endothelium necessitates interaction with red blood cells (RBCs). Rheology co-factors such as a high hematocrit and a high shear rate are known to promote platelet mass transport towa...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2017.06.044

    authors: Guilbert C,Chayer B,Allard L,Yu FTH,Cloutier G

    更新日期:2017-08-16 00:00:00

  • Evaluation of brain-skull interface modelling approaches on the prediction of acute subdural hematoma in the elderly.

    abstract::Acute subdural hematoma (ASDH) in the elderly is currently a matter of concern due to the growing number of the aging population and their higher incident rate compared to the younger adults. Computational head models that can replicate this age-related injury pattern are valuable tools to help addressing this concern...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.109787

    authors: Zhou Z,Li X,Kleiven S

    更新日期:2020-05-22 00:00:00

  • The utility of an empirically derived co-activation ratio for muscle force prediction through optimization.

    abstract::Biomechanical optimization models that apply efficiency-based objective functions often underestimate or negate antagonist co-activation. Co-activation assists movement control, joint stabilization and limb stiffness and should be carefully incorporated into models. The purposes of this study were to mathematically de...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.077

    authors: Brookham RL,Middlebrook EE,Grewal TJ,Dickerson CR

    更新日期:2011-05-17 00:00:00

  • Some mechanical properties of goose femoral cortical bone.

    abstract::The ultimate compressive strength and modulus of elasticity of femoral cortical bone from adult geese (Anser anser), were determined by sex and by quadrant by compressing small right circular cylinders which were 2.4 mm in height and 0.8 mm in diameter. The average ultimate compressive strength was 183 +/- 29 MPa. The...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(83)90108-2

    authors: McAlister GB,Moyle DD

    更新日期:1983-01-01 00:00:00

  • Effect of attachment types and number of implants supporting mandibular overdentures on stress distribution: a computed tomography-based 3D finite element analysis.

    abstract::The objective of this study was to calculate stresses in bone tissue surrounding uncoupled and splinted implants that are induced by a bite force applied to the mandible and to determine whether the number of mandibular overdenture supporting implants in mandibular bone influence the stress distribution. A human adult...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2014.10.022

    authors: Arat Bilhan S,Baykasoglu C,Bilhan H,Kutay O,Mugan A

    更新日期:2015-01-02 00:00:00

  • Hemiarthroplasty of hip joint: An experimental validation using porcine acetabulum.

    abstract::Biphasic properties of articular cartilage allow it to be an excellent bearing material and have been studied through several simplified experiments as well as finite element modelling. However, three-dimensional biphasic finite element (FE) models of the whole joint are rare. The current study was carried out to expe...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.02.140

    authors: Pawaskar SS,Grosland NM,Ingham E,Fisher J,Jin Z

    更新日期:2011-05-17 00:00:00

  • Evaluation of limb compartments with increased interstitial pressure. An improved noninvasive method for determining quantitative hardness.

    abstract::The purpose of this project was to study a noninvasive method of evaluating limbs at risk of compartment syndrome. Untreated limb compartment syndrome may lead to irreversible dysfunction, chronic pain and contracture. An improved means of obtaining quantitative hardness measurements is reported. The handheld noninvas...

    journal_title:Journal of biomechanics

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.jbiomech.2004.07.030

    authors: Steinberg BD

    更新日期:2005-08-01 00:00:00

  • Construction of healthy arteries using computed tomography and virtual histology intravascular ultrasound.

    abstract::Vessel geometry for numerical analysis is generally obtained by computed tomography (CT) or magnetic resonance imaging (MRI) and intravascular ultrasound (IVUS). Most medical imaging is obtained from patients for hemodynamic analysis due to the properties of vascular disease and the difficulties in angiography. To pre...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.04.003

    authors: Ryou HS,Kim S,Kim SW,Cho SW

    更新日期:2012-06-01 00:00:00

  • A method for automated control of belt velocity changes with an instrumented treadmill.

    abstract::Increased practice difficulty during asymmetrical split-belt treadmill rehabilitation has been shown to improve gait outcomes during retention and transfer tests. However, research in this area has been limited by manual treadmill operation. In the case of variable practice, which requires stride-by-stride changes to ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.017

    authors: Hinkel-Lipsker JW,Hahn ME

    更新日期:2016-01-04 00:00:00

  • Are mineralized tissues open crystal foams reinforced by crosslinked collagen? Some energy arguments.

    abstract::Which of the elementary components (hydroxyapatite (HA) crystals, collagen, non-collagenous organic matter, water) do significantly contribute to the ultrastructural elastic stiffness magnitude and anisotropy of mineralized tissues; and how, i.e. through which shapes and assemblages (which micromechanical morphology)?...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00080-5

    authors: Hellmich Ch,Ulm FJ

    更新日期:2002-09-01 00:00:00

  • Constrained least-squares optimization for robust estimation of center of rotation.

    abstract::This paper presents a new direct method for estimating the average center of rotation (CoR). An existing least-squares (LS) solution has been shown by previous works to have reduced accuracy for data with small range of motion (RoM). Alternative methods proposed to improve the CoR estimation use iterative algorithms. ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.05.010

    authors: Chang LY,Pollard NS

    更新日期:2007-01-01 00:00:00

  • The consistency of maximum running speed measurements in humans using a feedback-controlled treadmill, and a comparison with maximum attainable speed during overground locomotion.

    abstract::Consistent measurement of maximum running speed overground is problematic due to the difficulty in precise, continual measurement of speed, and the substantial workload in accelerating the body promoting the onset of fatigue. Treadmills remove the requirement for acceleration which enables more repeats. They also allo...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.07.024

    authors: Bowtell MV,Tan H,Wilson AM

    更新日期:2009-11-13 00:00:00

  • Measurement of local diffusion and composition in degraded articular cartilage reveals the unique role of surface structure in controlling macromolecular transport.

    abstract::Developing effective therapeutics for osteoarthritis (OA) necessitates that such molecules can reach and target chondrocytes within articular cartilage. However, predicting how well very large therapeutic molecules diffuse through cartilage is often difficult, and the relationship between local transport mechanics for...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.10.019

    authors: DiDomenico CD,Kaghazchi A,Bonassar LJ

    更新日期:2019-01-03 00:00:00

  • Posture shifting after spinal cord injury using functional neuromuscular stimulation--a computer simulation study.

    abstract::The ability for individuals with spinal cord injury (SCI) to affect changes in standing posture with functional neuromuscular stimulation (FNS) was explored using an anatomically inspired musculoskeletal model of the trunk, pelvis and lower extremities (LE). The model tracked trajectories for anteriorly and laterally ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.12.020

    authors: Audu ML,Nataraj R,Gartman SJ,Triolo RJ

    更新日期:2011-06-03 00:00:00

  • Quantifying thumb opposition kinematics using dynamic computed tomography.

    abstract::Current motion capture techniques all have shortcomings when applied to the 3D quantitative evaluation of thumb base motion. Dynamic CT might overcome these shortcomings but, so far, robustness of this technique in more than one specimen has not yet been demonstrated. The aim of the current study is to further evaluat...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.05.008

    authors: Kerkhof FD,Brugman E,D'Agostino P,Dourthe B,van Lenthe GH,Stockmans F,Jonkers I,Vereecke EE

    更新日期:2016-06-14 00:00:00

  • A novel validation and calibration method for motion capture systems based on micro-triangulation.

    abstract::Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accur...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.04.009

    authors: Nagymáté G,Tuchband T,Kiss RM

    更新日期:2018-06-06 00:00:00

  • Harmonizing finite element modelling for non-invasive strength estimation by high-resolution peripheral quantitative computed tomography.

    abstract::The finite element (FE) method based on high-resolution peripheral quantitative computed tomography (HR-pQCT) use a variety of tissue constitutive properties and boundary conditions at different laboratories making comparison of mechanical properties difficult. Furthermore, the advent of a second-generation HR-pQCT po...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.08.030

    authors: Whittier DE,Manske SL,Kiel DP,Bouxsein M,Boyd SK

    更新日期:2018-10-26 00:00:00

  • Jet collisions and vortex reversal in the human left ventricle.

    abstract::Unnatural dynamics of the notorious vortex in the left ventricle is often associated with cardiac disease. Understanding how different cardiac diseases alter the flow physics in the left ventricle may therefore provide a powerful tool for disease detection. In this work, the fluid dynamics in the left ventricle subjec...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.07.023

    authors: Di Labbio G,Kadem L

    更新日期:2018-09-10 00:00:00

  • Plantar pressures in identical and non-identical twins.

    abstract::Identifying environmental risk factors for musculoskeletal disorders is challenging due to the number of potential confounders. Twins are of particular interest for researchers interested in studying these types of problems due to their inherent control for the influence of genetic factors. In twin studies, this popul...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.01.059

    authors: Telfer S,Bigham JJ,Sudduth ASM

    更新日期:2019-03-27 00:00:00

  • Canine intersegmental hip joint forces and moments before and after cemented total hip replacement.

    abstract::Intersegmental forces and moments (i.e. resultant free body forces and moments computed at the joint centers) were studied in canine hindlimbs before and after cemented total hip replacement (THR). Five large, adult, mixed-breed dogs were selected. Their gait was recorded (while leash-walked) before surgery using high...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90028-l

    authors: Dogan S,Manley PA,Vanderby R Jr,Kohles SS,Hartman LM,McBeath AA

    更新日期:1991-01-01 00:00:00

  • Effect of temperature on residual force enhancement in single skeletal muscle fibers.

    abstract::It is well accepted that the steady-state isometric force following active stretching of a muscle is greater than the steady-state isometric force obtained in a purely isometric contraction at the same length. This property of skeletal muscle has been called residual force enhancement (FE). Despite decades of research...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.06.007

    authors: Lee EJ,Herzog W

    更新日期:2008-08-28 00:00:00

  • The effect of tendon viscoelastic stiffness on the dynamic performance of isometric muscle.

    abstract::The effect of tendons viscoelastic stiffness on the dynamic response of the cat's tibialis anterior muscle under isometric conditions was determined. It was shown that the dynamic response model of the muscle derived under sinusoidal contraction-relaxation in the range of 20-80% of its maximal isometric tension was no...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90355-q

    authors: Baratta R,Solomonow M

    更新日期:1991-01-01 00:00:00