Abstract:
:Stationary cycling is typically recommended following total knee arthroplasty (TKA) operations. However, knee joint biomechanics during cycling remains mostly unknown for TKA patients. Biomechanical differences between the replaced and non-replaced limb may inform applications of cycling in TKA rehabilitation. The purpose of this study was to examine the knee joint biomechanics of TKA patients during stationary cycling. Fifteen TKA participants cycled at 80 revolutions per minute and workrates of 80 W and 100 W while kinematics (240 Hz) and pedal reaction forces using a pair of instrumented pedals (1200 Hz) were collected. A 2x2 (limb × workrate) repeated measures ANOVA was run with an alpha of 0.05. Peak knee extension moment (KEM, p = 0.034) and vertical pedal reaction force (p = 0.038) were significantly reduced in the replaced limbs compared to non-replaced limbs by 21.3% and 5.3%, respectively. Peak KEM did not change for TKA patients with the increased workrate (p = 0.750). However, both peak hip extension moment (p = 0.009) and ankle plantarflexion moment (p = 0.017) increased due to increased workrate. Patients following TKA showed similar decreases in peak KEM and vertical pedal reaction force in their replaced compared to non-replaced limbs, as previously seen in gait. Patients of TKA may rely on their hip and ankle extensors to increases in workrate. Increasing intensity by 20 W did not exacerbate any inter-limb differences for peak KEM and vertical PRF.
journal_name
J Biomechjournal_title
Journal of biomechanicsauthors
Hummer E,Thorsen T,Weinhandl JT,Cates H,Zhang Sdoi
10.1016/j.jbiomech.2020.110111subject
Has Abstractpub_date
2021-01-22 00:00:00pages
110111eissn
0021-9290issn
1873-2380pii
S0021-9290(20)30535-2journal_volume
115pub_type
杂志文章abstract::A fast (0.1 mm steps within 2 ms), strong (40 N continuously) and accurate (resolution 0.002 N and 1.0 micron) muscle ergometer was developed to test dynamic and static properties of mammalian muscle. Both for twitches and for tetani isometric, isokinetic and isotonic contractions can be measured accurately. Force-vel...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(87)90312-5
更新日期:1987-01-01 00:00:00
abstract::The present study is aimed at investigating changes in the coordination of arm and leg movements in young healthy subjects. It was hypothesized that with changes in walking velocity there is a change in frequency and phase coupling between the arms and the legs. In addition, it was hypothesized that the preferred freq...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00020-8
更新日期:2000-07-01 00:00:00
abstract::One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made t...
journal_title:Journal of biomechanics
pub_type: 杂志文章,评审
doi:10.1016/j.jbiomech.2015.11.031
更新日期:2016-07-26 00:00:00
abstract::The multi-signal mechanical environment mammalian cells experience is often unaccounted for in current mechanical stimulation studies. To address this we developed a novel technique to induce dual integrated force inputs, uniaxial stretch and fluid shear stress and present here for the first time a vector logic-gate f...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2014.12.047
更新日期:2015-02-26 00:00:00
abstract::Due to the increased availability of digital human models, the need for knowing human movement is important in product design process. If the human motion is derived rapidly as design parameters change, a developer could determine the optimal parameters. For example, the optimal design of the door panel of an automobi...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2018.12.009
更新日期:2019-02-14 00:00:00
abstract::It is difficult to define the 'physiological' mechanical properties of bone. Traumatic failures in-vivo are more likely to be orders of magnitude faster than the quasistatic tests usually employed in-vitro. We have reported recently [Hansen, U., Zioupos, P., Simpson, R., Currey, J.D., Hynd, D., 2008. The effect of str...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.07.025
更新日期:2008-10-20 00:00:00
abstract::The aim of this work is to contribute to elucidating the mechanism underlying gas mixing in the human pulmonary airways. For this purpose, a particular attempt is made to analyse the fluid mechanical aspects of gaseous dispersion using bolus response methods. The experiments were performed on five normal subjects by i...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(85)90295-7
更新日期:1985-01-01 00:00:00
abstract::The non-disabled human ankle joint was examined during walking in an attempt to determine overall system characteristics for use in the design of ankle prostheses. The hypothesis of the study was that the quasi-stiffness of the ankle changes when walking at different walking speeds. The hypothesis was examined using s...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2004.01.017
更新日期:2004-10-01 00:00:00
abstract::During respiration, upper airway (UA) collapse occurs when the forces generated from the negative UA pressures exceed the forces produced by the UA muscles; which leads to loose soft tissue at the back of the mouth. At predetermined titration pressure, the Continuous Positive Airway Pressure (CPAP) normally provides a...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2016.11.005
更新日期:2016-12-08 00:00:00
abstract::Intravascular stents are small tube-like structures expanded into stenotic arteries to restore blood flow perfusion to the downstream tissues. The stent is mounted on a balloon catheter and delivered to the site of blockage. When the balloon is inflated, the stent expands and is pressed against the inner wall of the c...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(02)00033-7
更新日期:2002-06-01 00:00:00
abstract::Multi-fragment fractures are still a challenge: current clinical practice relies on plates and screws. Treatment of fractures of the proximal humerus has the intra-operative risk of articular damage when inserting multiple screws. Distal-varus collapse of the head is a frequent complication in osteoporotic patients. T...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2020.110138
更新日期:2021-01-22 00:00:00
abstract::Healthy patellofemoral (PF) joint mechanics are critical to optimal function of the knee joint. Patellar maltracking may lead to large joint reaction loads and high stresses on the articular cartilage, increasing the risk of cartilage wear and the onset of osteoarthritis. While the mechanical sources of PF joint dysfu...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.12.020
更新日期:2016-01-25 00:00:00
abstract::Inguinal herniation represents a common condition requiring surgical intervention. Despite being regarded as a connective tissue disorder of uncertain cause, research has focused predominantly on biochemical changes in the key tissue layer, the transversalis fascia (TF) with little direct analysis of functional tissue...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2008.08.018
更新日期:2008-12-05 00:00:00
abstract::Skeletal muscle is a very dynamic tissue, thus accurate quantification of skeletal muscle stiffness throughout its functional range is crucial to improve the physical functioning and independence following pathology. Shear wave elastography (SWE) is an ultrasound-based technique that characterizes tissue mechanical pr...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.07.033
更新日期:2013-09-27 00:00:00
abstract::The swimming process by which mammal spermatozoa progress towards an egg within the reproductive organs is important in achieving successful internal fertilization. The viscosity of oviductal mucus is more than two orders of magnitude greater than that of water, and oviductal mucus also has non-Newtonian properties. I...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2015.08.005
更新日期:2015-09-18 00:00:00
abstract::A new technique to study the mechanical properties of collagen lattices or dermal equivalents is described. With the help of the load-extension curve obtained with a uniaxial traction apparatus, a stiffness modulus varying from 0.06 to 1 MPa is calculated from the studied parameters (duration of culture, collagen and ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(92)90250-5
更新日期:1992-01-01 00:00:00
abstract::Gradual collagen recruitment has been hypothesized as the underlying mechanism for the mechanical stiffening with increasing stress in arteries. In this work, we investigated this hypothesis in eight rabbit carotid arteries by directly measuring the distribution of collagen recruitment stretch under increasing circumf...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.11.016
更新日期:2012-03-15 00:00:00
abstract::Numerical models commonly account for elastic inhomogeneity in cortical bone using power-law scaling relationships with various measures of tissue density, but limited experimental data exists for anatomic variation in elastic anisotropy. A recent study revealed anatomic variation in the magnitude and anisotropy of el...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2011.04.009
更新日期:2011-06-03 00:00:00
abstract::Anterior cruciate ligament (ACL) volume and T2∗ relaxation times from magnetic resonance (MR) images have been previously shown to predict the structural properties of healing ligaments. We investigated whether MR imaging scan resolution and condition (in vivo, in situ, or ex vivo) affected ACL volume and T2∗ relaxati...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.03.010
更新日期:2017-05-03 00:00:00
abstract::The peroneus longus (PL) is a rearfoot evertor, important in frontal plane foot motion. Studying PL function has been limited by previous electromyography (EMG) studies reporting poor between-day reliability. Due to its close proximity to adjacent muscles, EMG measures of PL may be susceptible to crosstalk, thus corre...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2019.01.037
更新日期:2019-03-27 00:00:00
abstract::Flexure is a major deformation mode of the aortic valve (AV) leaflet, particularly in the commissural region where the upper portion of the leaflet joins the aortic root. However, there are no existing data known on the mechanical properties of leaflet in the commissural region. To address this issue, we quantified th...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.026
更新日期:2006-01-01 00:00:00
abstract::Anesthetized, carefully positioned, female, weanling, white-haired pigs were used to test the hypothesis that (1) interface pressure, the pressure between the skin and an external load, can be used to predict the interstitial fluid pressure over the wings of ilia and the last dorsal spinous process and (2) three-dimen...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(91)90322-e
更新日期:1991-01-01 00:00:00
abstract::Swelling effects in cartilage originate from an interstitial osmotic pressure generated by the presence of negatively charged proteoglycans in the tissue. This swelling pressure gives rise to a non-zero residual strain in the cartilage solid matrix in the absence of externally applied loads. Previous studies have quan...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(98)00184-5
更新日期:1999-04-01 00:00:00
abstract::Detecting and assessing an individual's gait can be important for medical diagnostic purposes and for developing and guiding follow-on rehabilitation protocols. Thus, an accurate, objective gait classification system has the potential to facilitate earlier diagnosis and improved clinical decision-making. Systems using...
journal_title:Journal of biomechanics
pub_type: 临床试验,杂志文章
doi:10.1016/j.jbiomech.2019.06.009
更新日期:2019-08-27 00:00:00
abstract::In presence of aortic stenosis, a jet is produced downstream of the aortic valve annulus during systole. The vena contracta corresponds to the location where the cross-sectional area of the flow jet is minimal. The maximal transvalvular pressure gradient (TPG(max)) is the difference between the static pressure in the ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2005.10.013
更新日期:2006-01-01 00:00:00
abstract::In order to provide physical information supporting the clinical use of flow mapping, an in vitro model was designed to measure the velocity fields in a pulsatile hydraulic turbulent jet. We used a peak velocity ranging from 2.5 to 5.5 m.s-1, an orifice diameter ranging from 5.8 to 11.3 mm and confined the jet in a re...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/0021-9290(90)90367-c
更新日期:1990-01-01 00:00:00
abstract::This paper presents a novel inverse estimation approach for the active contraction stresses of tongue muscles during speech. The proposed method is based on variational data assimilation using a mechanical tongue model and 3D tongue surface shapes for speech production. The mechanical tongue model considers nonlinear ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2017.09.008
更新日期:2017-11-07 00:00:00
abstract::Stem-cement and cement-bone interfacial failures as well as cement fractures have been noted in cemented total hip arthroplasty (THA) as the cause of aseptic loosening. Attempts to reduce the risk of femoral component loosening include improving the stem-cement interface by various coatings, using a textured or porous...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2012.12.010
更新日期:2013-03-15 00:00:00
abstract::Coronary artery disease results in blockages or narrowing of the artery lumen. Drug eluting stents (DES) were developed to replace bare metal stents in an effort to combat re-blocking of the diseased artery following treatment. The numerical models developed within this study focus on representing the changing trends ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/j.jbiomech.2013.09.017
更新日期:2014-01-03 00:00:00
abstract::Subchondral bone undecalcified samples, extracted from bovine femoral heads, are subjected to a direct tensile load. The Young's modulus of each sample is determined from repeated tests within the elastic limit. In a last test, the tensile load is increased up to the specimen failure, determining the ultimate tensile ...
journal_title:Journal of biomechanics
pub_type: 杂志文章
doi:10.1016/s0021-9290(00)00074-9
更新日期:2000-09-01 00:00:00