Cellular force signal integration through vector logic gates.

Abstract:

:The multi-signal mechanical environment mammalian cells experience is often unaccounted for in current mechanical stimulation studies. To address this we developed a novel technique to induce dual integrated force inputs, uniaxial stretch and fluid shear stress and present here for the first time a vector logic-gate framework to characterize cellular response as a function of cytoskeletal reorganization. Using this framework we found that under fluid shear stress and uniaxial stretch NIH 3T3 fibroblasts responded by the Stretch OR Shear vector logic-gate and HUVECs responded by the NOT Stretch OR Shear vector logic-gate. We further developed a parsimonious model of cellular response to multiple mechanical stimuli, which provides a unifying model that captured the experimental response of both cell types.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Steward RL Jr,Tan C,Cheng CM,LeDuc PR

doi

10.1016/j.jbiomech.2014.12.047

subject

Has Abstract

pub_date

2015-02-26 00:00:00

pages

613-20

issue

4

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(14)00715-5

journal_volume

48

pub_type

杂志文章
  • Measurement of in vivo anterior cruciate ligament strain during dynamic jump landing.

    abstract::Despite recent attention in the literature, anterior cruciate ligament (ACL) injury mechanisms are controversial and incidence rates remain high. One explanation is limited data on in vivo ACL strain during high-risk, dynamic movements. The objective of this study was to quantify ACL strain during jump landing. Marker...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2010.10.028

    authors: Taylor KA,Terry ME,Utturkar GM,Spritzer CE,Queen RM,Irribarra LA,Garrett WE,DeFrate LE

    更新日期:2011-02-03 00:00:00

  • Regressions for estimating muscle parameters in the thoracic and lumbar trunk for use in musculoskeletal modeling.

    abstract::Musculoskeletal modeling requires information on muscle parameters such as cross-sectional area (CSA) and moment arms. A variety of previous studies have reported muscle parameters in the trunk based on in vivo imaging, but there remain gaps in the available data as well as limitations in the generalizability of such ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.10.004

    authors: Anderson DE,D'Agostino JM,Bruno AG,Manoharan RK,Bouxsein ML

    更新日期:2012-01-03 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • Reliability of upper and lower extremity anthropometric measurements and the effect on tissue mass predictions.

    abstract::Accurate modeling of soft tissue motion effects relative to bone during impact requires knowledge of the mass of soft and rigid tissues in living people. Holmes et al., [2005. Predicting in vivo soft tissue masses of the lower extremity using segment anthropometric measures and DXA. Journal of Applied Biomechanics, 21...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.02.013

    authors: Burkhart TA,Arthurs KL,Andrews DM

    更新日期:2008-01-01 00:00:00

  • Compression data on bovine bone confirms that a "stressed volume" principle explains the variability of fatigue strength results.

    abstract::The literature contains many measurements of the fatigue properties of compact bone, but these experimental results have been difficult to interpret and use due to a large amount of apparent scatter: variation in the number of cycles to failure for a given cyclic stress or strain range. Recently Taylor (1998a, Journal...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00112-8

    authors: Taylor D,O'Brien F,Prina-Mello A,Ryan C,O'Reilly P,Lee TC

    更新日期:1999-11-01 00:00:00

  • Load transfer across the scapula during humeral abduction.

    abstract::Stress analysis in the individual parts of the scapula under normal physiological conditions is necessary to understand the load transfer mechanism, its relation with morphology of bone and to analyse the deviations in stress patterns due to implantation of the glenoid. The purpose of this study was to obtain stress d...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2003.11.025

    authors: Gupta S,van der Helm FC

    更新日期:2004-07-01 00:00:00

  • Impact of bifurcation angle and other anatomical characteristics on blood flow - A computational study of non-stented and stented coronary arteries.

    abstract::The hemodynamic influence of vessel shape such as bifurcation angle is not fully understood with clinical and quantitative observations being equivocal. The aim of this study is to use computational modeling to study the hemodynamic effect of shape characteristics, in particular bifurcation angle (BA), for non-stented...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.038

    authors: Beier S,Ormiston J,Webster M,Cater J,Norris S,Medrano-Gracia P,Young A,Cowan B

    更新日期:2016-06-14 00:00:00

  • Strain shielding in distal femur after patellofemoral arthroplasty under different activity conditions.

    abstract::Strain shielding, a mechanical effect occurring in structures combining stiff with more flexible materials, is considered to lead to a reduction of density in bone surrounding the implant. This effect can be related to the weakness of the implant fixation, which can promote implant loosening. Several studies describe ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.09.048

    authors: Meireles S,Completo A,António Simões J,Flores P

    更新日期:2010-02-10 00:00:00

  • Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion.

    abstract::Inguinal herniation represents a common condition requiring surgical intervention. Despite being regarded as a connective tissue disorder of uncertain cause, research has focused predominantly on biochemical changes in the key tissue layer, the transversalis fascia (TF) with little direct analysis of functional tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.018

    authors: Kureshi A,Vaiude P,Nazhat SN,Petrie A,Brown RA

    更新日期:2008-12-05 00:00:00

  • Different methods to estimate total power and its components during lifting.

    abstract::A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(92)90045-3

    authors: de Looze MP,Bussmann JB,Kingma I,Toussaint HM

    更新日期:1992-09-01 00:00:00

  • Three-dimensional intervertebral kinematics in the healthy young adult cervical spine during dynamic functional loading.

    abstract::The objective of this study was to determine the intervertebral kinematics of the young, healthy cervical spine during dynamic, three-dimensional, functional loading. Intervertebral motion was characterized by the range of motion (ROM) and the helical axis of motion (HAM). Biplane radiographs of the cervical spine wer...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.02.049

    authors: Anderst WJ,Donaldson WF 3rd,Lee JY,Kang JD

    更新日期:2015-05-01 00:00:00

  • Ex vivo loading of trussed implants for spine fusion induces heterogeneous strains consistent with homeostatic bone mechanobiology.

    abstract::A truss structure was recently introduced as an interbody fusion cage. As a truss system, some of the connected elements may be in a state of compression and others in tension. This study aimed to quantify both the mean and variance of strut strains in such an implant when loaded in a simulated fusion condition with v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.10.051

    authors: Caffrey JP,Cory E,Wong VW,Masuda K,Chen AC,Hunt JP,Ganey TM,Sah RL

    更新日期:2016-12-08 00:00:00

  • A mathematical model to investigate the effects of intravenous fluid administration and fluid loss.

    abstract::The optimal fluid administration protocol for critically ill perioperative patients is hard to estimate due to the lack of tools to directly measure the patient fluid status. This results in the suboptimal clinical outcome of interventions. Previously developed predictive mathematical models focus on describing the fl...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.03.002

    authors: Rosalina TT,Bouwman RA,van Sambeek MRHM,van de Vosse FN,Bovendeerd PHM

    更新日期:2019-05-09 00:00:00

  • Does cancellous screw insertion torque depend on bone mineral density and/or microarchitecture?

    abstract::During insertion of a cancellous bone screw, the torque level reaches a plateau, at the engagement of all the screw threads prior to the screw head contact. This plateau torque (T(Plateau)) was found to be a good predictor of the insertion failure torque (stripping) and also exhibited strong positive correlations with...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.11.030

    authors: Ab-Lazid R,Perilli E,Ryan MK,Costi JJ,Reynolds KJ

    更新日期:2014-01-22 00:00:00

  • Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

    abstract::Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the c...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.01.021

    authors: Lundberg HJ,Pedersen DR,Baer TE,Muste M,Callaghan JJ,Brown TD

    更新日期:2007-01-01 00:00:00

  • Variability of tissue mineral density can determine physiological creep of human vertebral cancellous bone.

    abstract::Creep is a time-dependent viscoelastic deformation observed under a constant prolonged load. It has been indicated that progressive vertebral deformation due to creep may increase the risk of vertebral fracture in the long-term. The objective of this study was to examine the relationships of creep with trabecular arch...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.03.025

    authors: Kim DG,Shertok D,Ching Tee B,Yeni YN

    更新日期:2011-06-03 00:00:00

  • Effect of LIMK2 RNAi on reorganization of the actin cytoskeleton in osteoblasts induced by fluid shear stress.

    abstract::The biomechanical characteristics of bone tissue and its cells under mechanical stress are significant for bone biomechanics research, but the mechanism of mechanotransduction is still unknown. It has been established that the actin cytoskeleton of osteoblasts plays an important role in this process. However, the stru...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.08.010

    authors: Fu Q,Wu C,Shen Y,Zheng S,Chen R

    更新日期:2008-11-14 00:00:00

  • Ligamentous versus physeal failure in murine medial collateral ligament biomechanical testing.

    abstract::This study examines the age at which a femoral physeal failure ceased to occur in a mouse model of medial collateral ligament (MCL) testing. Biomechanical testing of the MCL with load to failure can result in physeal failure rather than MCL failure in skeletally immature animals. Failure mode depended significantly on...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.05.014

    authors: El-Zawawy HB,Silva MJ,Sandell LJ,Wright RW

    更新日期:2005-04-01 00:00:00

  • The exoskeletal structure and tensile loading behavior of an ant neck joint.

    abstract::Insects have evolved mechanical form and function over millions of years. Ants, in particular, can lift and carry heavy loads relative to their body mass. Loads are lifted with the mouthparts, transferred through the neck joint to the thorax, and distributed over six legs and tarsi (feet) that anchor to the supporting...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.10.053

    authors: Nguyen V,Lilly B,Castro C

    更新日期:2014-01-22 00:00:00

  • Bi-linear mechanical property determination of acellular human patellar tendon grafts for use in anterior cruciate ligament replacement.

    abstract::Anterior cruciate ligament rupture is rising in its prevalence amongst the young and those with physically active lifestyles. Acellular human patellar tendon (PT) grafts offer a promising restoration solution, returning knee joint stability and overcoming some of the current disadvantages of autologous or allogeneic g...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2016.03.041

    authors: Herbert A,Brown C,Rooney P,Kearney J,Ingham E,Fisher J

    更新日期:2016-06-14 00:00:00

  • A laser-aligned method for anthropometry of hands.

    abstract::We have developed a laser-aligned measuring device to facilitate the measurement of linear hand dimensions. Our objective has been to make a simple, clinically applicable device for anthropometry of the hands in patients with arthritis in order to gauge the progression of hand deformities. The system provides an alter...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(03)00121-0

    authors: Highton J,Davidson P,Markham V

    更新日期:2003-09-01 00:00:00

  • Large scale simulation of red blood cell aggregation in shear flows.

    abstract::Aggregation of highly deformable red blood cells (RBCs) significantly affects the blood flow in the human circulatory system. To investigate the effect of deformation and aggregation of RBCs in blood flow, a mathematical model has been established by coupling the interaction between the fluid and the deformable solids...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2013.05.010

    authors: Xu D,Kaliviotis E,Munjiza A,Avital E,Ji C,Williams J

    更新日期:2013-07-26 00:00:00

  • Vastus lateralis and vastus medialis produce distinct mediolateral forces on the patella but similar forces on the tibia in the rat.

    abstract::Improper activation of the quadriceps muscles vastus medialis (VM) and vastus lateralis (VL) has been implicated in the development of patellofemoral pain (PFP). This explanation of PFP assumes that VM and VL produce opposing mediolateral forces on the patella. Although studies have provided evidence for opposing acti...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.09.007

    authors: Sandercock TG,Wei Q,Dhaher YY,Pai DK,Tresch MC

    更新日期:2018-11-16 00:00:00

  • Biomechanical response to mediolateral foot-placement perturbations during walking.

    abstract::Dynamic balance in the frontal plane requires active control, which is accomplished largely through control of mediolateral foot placement. Individuals without mobility impairments have the ability to compensate for variability in foot-placement to maintain their balance; however, it is unknown how individuals respond...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110213

    authors: Brough LG,Klute GK,Neptune RR

    更新日期:2020-12-28 00:00:00

  • Effect of scaffold material, construct length and mechanical stimulation on the in vitro stiffness of the engineered tendon construct.

    abstract::Introducing mesenchymal stem cell (MSC)-seeded collagen constructs into load-protected wound sites in the rabbit patellar and Achilles tendons significantly improves their repair outcome compared to natural healing of the unfilled defect. However, these constructs would not be acceptable alternatives for repairing com...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.11.009

    authors: Nirmalanandhan VS,Rao M,Shearn JT,Juncosa-Melvin N,Gooch C,Butler DL

    更新日期:2008-01-01 00:00:00

  • In vivo biomechanical behavior of the human heel pad during the stance phase of gait.

    abstract::A technique is introduced for simultaneous measurements of the heel pad tissue deformation and the heel-ground contact stresses developing during the stance phase of gait. Subjects walked upon a gait platform integrating the contact pressure display optical method for plantar pressure measurements and a digital radiog...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(01)00143-9

    authors: Gefen A,Megido-Ravid M,Itzchak Y

    更新日期:2001-12-01 00:00:00

  • Three-dimensional tissue deformation in subcutaneous tissues overlying bony prominences may help to explain external load transfer to the interstitium.

    abstract::Anesthetized, carefully positioned, female, weanling, white-haired pigs were used to test the hypothesis that (1) interface pressure, the pressure between the skin and an external load, can be used to predict the interstitial fluid pressure over the wings of ilia and the last dorsal spinous process and (2) three-dimen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90322-e

    authors: Dodd KT,Gross DR

    更新日期:1991-01-01 00:00:00

  • Friction in metal-on-metal total disc arthroplasty: effect of ball radius.

    abstract::Total disc arthroplasty (TDA) can be used to replace a degenerated intervertebral disc in the spine. There are different designs of prosthetic discs, but one of the most common is a ball-and-socket combination. Contact between the bearing surfaces can result in high frictional torque, which can then result in wear and...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2011.11.045

    authors: Moghadas P,Mahomed A,Hukins DW,Shepherd DE

    更新日期:2012-02-02 00:00:00

  • Bivariate optimization of pedalling rate and crank arm length in cycling.

    abstract::The contribution of this paper is a bivariate optimization of cycling performance. Relying on a biomechanical model of the lower limb, a cost function derived from the joint moments developed during cycling is computed. At constant average power, both pedalling rate (i.e. rpm) and crank arm length are systematically v...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90016-4

    authors: Hull ML,Gonzalez H

    更新日期:1988-01-01 00:00:00

  • Hemodialysis arterio-venous graft design reducing the hemodynamic risk of vascular access dysfunction.

    abstract::Although arterio-venous grafts (AVGs) represent the second choice as permanent vascular access for hemodialysis, this solution is still affected by a relevant failure rate due to graft thrombosis, and development of neointimal hyperplasia (IH) at the distal vein. As a key role in these processes has been attributed to...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109591

    authors: De Nisco G,Gallo D,Siciliano K,Tasso P,Lodi Rizzini M,Mazzi V,Calò K,Antonucci M,Morbiducci U

    更新日期:2020-02-13 00:00:00