Matrix mechanical properties of transversalis fascia in inguinal herniation as a model for tissue expansion.

Abstract:

:Inguinal herniation represents a common condition requiring surgical intervention. Despite being regarded as a connective tissue disorder of uncertain cause, research has focused predominantly on biochemical changes in the key tissue layer, the transversalis fascia (TF) with little direct analysis of functional tissue mechanics. Connective tissue tensile properties are dominated by collagen fibril density and architecture. This study has correlated mechanical properties of herniated TF (HTF) and non-herniated TF (NHTF) with fibrillar properties at the ultrastructural level by quasi-static tensile mechanical analysis and image analysis of collagen electron micrographs. No significant difference was found between any of the key mechanical properties (break stress, strain or modulus) for HTF and NHTF. In addition, no significant differences were found in average collagen fibril diameter, density or fibre bundle spacing. However, both groups displayed anisotropy with greater break stress (p=0.001) on average in the transverse anatomical plane compared to the longitudinal plane in a mean ratio of 2:1 (anisotropy ratio), though there was no evidence of a difference in this ratio for HTF and NHTF for both break stress and modulus. It was noted that this anisotropy ratio corresponds closely with the expected force distribution on a model cylindrical structure loaded axially. The absence of other functional differences does not support the idea of a failing (injured) tissue but is consistent with it being a tissue undergoing chronic growth/expansion under multi-vectored mechanical loading. These findings provide new clues to collagen tissue herniation for mathematical modelling and model tissue engineering.

journal_name

J Biomech

journal_title

Journal of biomechanics

authors

Kureshi A,Vaiude P,Nazhat SN,Petrie A,Brown RA

doi

10.1016/j.jbiomech.2008.08.018

subject

Has Abstract

pub_date

2008-12-05 00:00:00

pages

3462-8

issue

16

eissn

0021-9290

issn

1873-2380

pii

S0021-9290(08)00445-4

journal_volume

41

pub_type

杂志文章
  • Factors influencing performance in the Hecht vault and implications for modelling.

    abstract::This paper investigated the factors that influence Hecht vault performance and assessed the level of model complexity required to give an adequate representation of vaulting. A five-segment planar simulation model with a visco-elastic shoulder joint and a torque generator at the shoulder joint was used to simulate the...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2004.02.039

    authors: King MA,Yeadon MR

    更新日期:2005-01-01 00:00:00

  • Measuring dynamic stability requirements during sitting pivot transfers using stabilizing and destabilizing forces in individuals with complete motor paraplegia.

    abstract::Dynamic stability requirements have never been quantified when long-term manual wheelchair users transfer themselves in a seated position from an initial surface to a target surface, a functional task commonly referred to as sitting pivot transfers (SPTs). Ten individuals with spinal cord injury (SCI), who rely on a m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.02.018

    authors: Gagnon D,Duclos C,Desjardins P,Nadeau S,Danakas M

    更新日期:2012-05-11 00:00:00

  • Hospital bed height influences biomechanics during bed egress: A comparative controlled study of patients with Parkinson disease.

    abstract::Although a significant proportion of patient falls occur during egress from the hospital bed, the biomechanical adaptations during egress from different bed heights are still largely unknown. The purpose of this study was to evaluate the effect of hospital bed height on natural transition during egress in patients wit...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110116

    authors: Xu H,Li X,Shi Y,An L,Taylor D,Christman M,Morse J,Merryweather A

    更新日期:2021-01-22 00:00:00

  • Articular contact in a three-dimensional model of the knee.

    abstract::This study is aimed at the analysis of articular contact in a three-dimensional mathematical model of the human knee-joint. In particular the effect of articular contact on the passive motion characteristics is assessed in relation to experimentally obtained joint kinematics. Two basically different mathematical conta...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(91)90019-j

    authors: Blankevoort L,Kuiper JH,Huiskes R,Grootenboer HJ

    更新日期:1991-01-01 00:00:00

  • Determination of subject-specific model parameters for visco-elastic elements.

    abstract::The determination of subject-specific model parameter values is necessary in order for a computer simulation model of human motion to be evaluated quantitatively. This study used an optimisation procedure along with a kinematically driven simulation model of the contact phase in running jumps to determine the elastic ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2005.05.012

    authors: Wilson C,King MA,Yeadon MR

    更新日期:2006-01-01 00:00:00

  • Comparison of mechanical energy expenditure of joint moments and muscle forces during human locomotion.

    abstract::The mechanical energy expenditures (MEEs) of two human lower extremity models with different sources of mechanical energy - (1) muscles and (2) joint moments - were compared theoretically. Sources of mechanical energy producing movement of Model 1 were eight muscle, three of which were two-joint muscles. Sources of me...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(95)00083-6

    authors: Prilutsky BI,Petrova LN,Raitsin LM

    更新日期:1996-04-01 00:00:00

  • Multichannel strain gauge telemetry for orthopaedic implants.

    abstract::In vivo measurements of the loads and deformations occurring in orthopaedic implants will allow future improvements to be made. This paper describes an extremely small telemetry for long term measurements with three strain gauges and methods for an absolutely safe implant design. Developed for measuring the load at hi...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(88)90009-7

    authors: Bergmann G,Graichen F,Siraky J,Jendrzynski H,Rohlmann A

    更新日期:1988-01-01 00:00:00

  • Mechanical behaviour of femoral bones in bending loading.

    abstract::A series of 33 human femoral bones have been subjected to a four point bending test at high strain rates. Two different failure modes were recognized. A Y shaped fracture at the middle region induced by a pure bending moment yielded a zone of non-linearity at the load vs deformation curve and a higher bending force, m...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(86)90021-7

    authors: Martens M,van Audekercke R,de Meester P,Mulier JC

    更新日期:1986-01-01 00:00:00

  • Altered frontal and transverse plane tibiofemoral kinematics and patellofemoral malalignments during downhill gait in patients with mixed knee osteoarthritis.

    abstract::Patients with knee osteoarthritis often present with signs of mixed tibiofemoral and patellofemoral joint disease. It has been suggested that altered frontal and transverse plane knee joint mechanics play a key role in compartment-specific patterns of knee osteoarthritis, but in-vivo evidence in support of this premis...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.05.015

    authors: Farrokhi S,Meholic B,Chuang WN,Gustafson JA,Fitzgerald GK,Tashman S

    更新日期:2015-07-16 00:00:00

  • Mass properties of the human mandible.

    abstract::Computer simulation of human masticatory dynamics requires specification of the jaw's mass properties. These are difficult to estimate, especially in living subjects. Here, we used calibrated computed tomography (CT) to determine the properties of eight osseous jaw specimens with adult dentitions. When the CT numbers ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(02)00057-x

    authors: Zhang F,Peck CC,Hannam AG

    更新日期:2002-07-01 00:00:00

  • Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study.

    abstract::Although shear wave elastography (SWE) has been used to indirectly measure passive tension in muscle tissues, it is unknown whether SWE can adequately evaluate passive tension in capsule tissues. This study investigated the relationship between the shear modulus and passive tension in the posterior shoulder capsule us...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109498

    authors: Iida N,Taniguchi K,Watanabe K,Miyamoto H,Taniguchi T,Fujimiya M,Katayose M

    更新日期:2020-01-23 00:00:00

  • Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging.

    abstract::Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnet...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2020.110085

    authors: Namiranian B,Jerban S,Ma Y,Dorthe EW,Masoud-Afsahi A,Wong J,Wei Z,Chen Y,D'Lima D,Chang EY,Du J

    更新日期:2020-12-02 00:00:00

  • Cervical spine morphology and ligament property variations: A finite element study of their influence on sagittal bending characteristics.

    abstract::Cervical spine finite element models reported in biomechanical literature usually represent a static morphology. Not considering morphology as a model parameter limits the predictive capabilities for applications in personalized medicine, a growing trend in modern clinical practice. The objective of the study was to i...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.12.044

    authors: John JD,Saravana Kumar G,Yoganandan N

    更新日期:2019-03-06 00:00:00

  • A rigid body model for the assessment of glenohumeral joint mechanics: Influence of osseous defects on range of motion and dislocation.

    abstract::The purpose of this study was to employ subject-specific computer models to evaluate the interaction of glenohumeral range-of-motion and Hill-Sachs humeral head bone defect size on engagement and shoulder dislocation. We hypothesized that the rate of engagement would increase as defect size increased, and that greater...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2015.11.001

    authors: Welsh MF,Willing RT,Giles JW,Athwal GS,Johnson JA

    更新日期:2016-02-29 00:00:00

  • Laterality in the gallop gait of horses.

    abstract::Bilateral asymmetry in gallop stride limb contact patterns of four Quarter Horse fillies was documented by high-speed cinematography. Horses were filmed with rider by two cameras simultaneously while galloping along a straightaway. Even though signaled for each gallop lead an equivalent number of times, horses frequen...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90285-5

    authors: Deuel NR,Lawrence LM

    更新日期:1987-01-01 00:00:00

  • Relationships between femoral fracture loads for two load configurations.

    abstract::Studies of proximal femoral strength usually involve one of two types of loading conditions, loading similar to joint loading during single-limb stance or loading simulating impact from a fall. When interpreting the results of studies involving only one of these load configurations, the question arises as to their app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00202-x

    authors: Keyak JH

    更新日期:2000-04-01 00:00:00

  • Heterogeneous linear elastic trabecular bone modelling using micro-CT attenuation data and experimentally measured heterogeneous tissue properties.

    abstract::High-resolution voxel-based finite element software, such as FEEBE developed at the NCBES, is widely used for studying trabecular bone at the micro-scale. A new approach to determine heterogeneous bone tissue material properties for computational models was proposed in this study. The specimen-specific range of tissue...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2008.05.014

    authors: Harrison NM,McDonnell PF,O'Mahoney DC,Kennedy OD,O'Brien FJ,McHugh PE

    更新日期:2008-08-07 00:00:00

  • Efficiency as a predictor of human jaw design in the sagittal plane.

    abstract::The effects of changing the direction of the bite force and of the mandibular joint reaction have been studied with a mathematical model assisted by a computer using the technique of linear programming. We conclude the following: In the sagittal plane the long axes of lower molars are each tilted in the direction that...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90246-6

    authors: Baragar FA,Osborn JW

    更新日期:1987-01-01 00:00:00

  • The influence of mechanical stimulus on the pattern of tissue differentiation in a long bone fracture--an FEM study.

    abstract::2D, coronal plane, finite elements models (FEMs) were developed from orthogonal radiographs of a diaphyseal tibial fracture and its reparative tissue at four different time points during healing. Each callus was separated into regions of common tissue histology by computerised radiographic analysis. Starting point val...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00189-x

    authors: Gardner TN,Stoll T,Marks L,Mishra S,Knothe Tate M

    更新日期:2000-04-01 00:00:00

  • Biomechanists can revolutionize the STEM pipeline by engaging youth athletes in sports-science based STEM outreach.

    abstract::Increasing diversity in the STEM (Science, Technology, Engineering, and Math) fields has become imperative to ensure equitable access to economic opportunity and to provide the technologically adept workforce of the future. The present STEM pipeline preferentially engages youth who are, not only aware of and intereste...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2019.109511

    authors: Drazan JF

    更新日期:2020-01-23 00:00:00

  • Influence of prosthetic humeral head size and medial offset on the mechanics of the shoulder with cuff tear arthropathy: a numerical study.

    abstract::This numerical study assesses the influence of an oversized humeral hemiprosthesis with a larger medial offset on the mechanics of the shoulder with cuff tear arthropathy (CTA). Shoulder elevation in the scapular plane is performed, and a Seebauer Type IIa CTA is simulated: a massive rotator cuff tear, a proximal and ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2012.11.021

    authors: Lemieux PO,Tétreault P,Hagemeister N,Nuño N

    更新日期:2013-02-22 00:00:00

  • Lumbar muscle force estimation using a subject-invariant 5-parameter EMG-based model.

    abstract::The use of electromyographic measures, in concert with modeled or empirical representations of muscle physiology, is a common approach for estimation of muscle force. Existing models of the lumbar musculature have allowed model parameters to vary for an individual subject. While this approach improves apparent predict...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(98)00055-4

    authors: Nussbaum MA,Chaffin DB

    更新日期:1998-07-01 00:00:00

  • Effect of material damping on bone remodelling.

    abstract::This paper considers the effect of internal material damping on the stresses, strains, and surface and internal remodelling behaviour in a section of axisymmetrical bone with a force-fitted axially oriented medullary pin. The bone response to several loading situations is modelled using visco-elastic equations. An app...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90291-0

    authors: Misra JC,Samanta S

    更新日期:1987-01-01 00:00:00

  • Finite element investigation of the loading rate effect on the spinal load-sharing changes under impact conditions.

    abstract::Sudden deceleration and frontal/rear impact configurations involve rapid movements that can cause spinal injuries. This study aimed to investigate the rotation rate effect on the L2-L3 motion segment load-sharing and to identify which spinal structure is at risk of failure and at what rotation velocity the failure may...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2009.03.036

    authors: El-Rich M,Arnoux PJ,Wagnac E,Brunet C,Aubin CE

    更新日期:2009-06-19 00:00:00

  • Compensation for inertial and gravity effects in a moving force platform.

    abstract::Force plates for human movement analysis provide accurate measurements when mounted rigidly on an inertial reference frame. Large measurement errors occur, however, when the force plate is accelerated, or tilted relative to gravity. This prohibits the use of force plates in human perturbation studies with controlled s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2018.05.009

    authors: Hnat SK,van Basten BJH,van den Bogert AJ

    更新日期:2018-06-25 00:00:00

  • Validation of a calibration technique for 6-DOF instrumented spatial linkages.

    abstract::This paper presents a practical and effective approach to the calibration of instrumented spatial linkages for biomechanical applications. A 6-DOF mechanical linkage with rotational transducers is designed and in-house manufactured for this purpose. In order to assess the validity of the proposed calibration technique...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2006.06.021

    authors: Gatti G,Danieli G

    更新日期:2007-01-01 00:00:00

  • Mechanical effects of continuous passive motion on the lumbar spine in seating.

    abstract::The aim of this study was to develop a model which describes the mechanical spinal response to small alternating pelvic stimulation induced by an active rotational movement of a normal chair. The rotary continuous passive motion (RCPM) of the seat about a vertical axis of only 0.6 degrees resulted in an increased in s...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/s0021-9290(99)00231-6

    authors: van Deursen DL,Lengsfeld M,Snijders CJ,Evers JJ,Goossens RH

    更新日期:2000-06-01 00:00:00

  • Effect of geometrical imperfections in confined compression tests on parameter evaluation of hydrated soft tissues.

    abstract::Experimental tests, such as the confined and unconfined compression and the indentation tests, are traditionally used to determine the poroelastic properties of hydrated soft tissues (HSTs). The purpose of this study was to quantitatively evaluate the reliability of H(A) and K values as identified from experimental co...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/j.jbiomech.2007.02.020

    authors: Gervaso F,Pennati G,Boschetti F

    更新日期:2007-01-01 00:00:00

  • Tensile stress-strain characteristics of the human meniscal material.

    abstract::The nonlinear stress-strain characteristics of the human menisci were determined by uniaxial elongation tests performed on circumferential and radial specimens prepared from different regions, layers, and locations. The properties of the collagen fibers and the matrix were calculated using the test results along with ...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(94)00081-e

    authors: Tissakht M,Ahmed AM

    更新日期:1995-04-01 00:00:00

  • Photogrammetric technique applied to anthropometric study of hands.

    abstract::Being concerned with physical anthropometric dimensions to explore avenues of research on hands and their working strategies, a research study was made to develop a suitable method by using available photogrammetric resources. The paper discusses the optimums of details found by this study, viz., the use of a Wild C-4...

    journal_title:Journal of biomechanics

    pub_type: 杂志文章

    doi:10.1016/0021-9290(87)90039-x

    authors: Ghosh SK,Poirier F

    更新日期:1987-01-01 00:00:00